Index 

 

  Important Safe Guards 

  Ambient Environment For Operating 

  Component Diagrams 

  Operating Introduction 

  Functions of Control Panel & Key Pads 

  LCD Display 

  Operation of Key Pads 

  Automatic Defrosting 

  Water Tank Full Warning 

  Processions Of Abnormal Compressor   

  Protection Of Extremely Low & High Temperature 

  Failure Of Humidity & Temperature Sensor 

  Memory function   

  Continuous Drainage 

  Maintenances & Cleaning 

  Specification 

 
 
 
 
 
 
 
 
 
 
 
 

 


background image

Important Safe Guards 

 

 
 

1

Please be sure your electricity is fully working 

 
3

To reduce a fire risk, ensure the unit is not placed 

next to a high temperature appliance. 

 

 

 

 

 

 

 

 

 

 

 

 

5

Do  not  allow  children  to  operate  this  unit.  Never 

disassemble  the  unit,  and  never  try  to  carry  out 

repairs or adjust the unit yourself. 

7

Do not use the unit when mounted on a slant. If for 

any reason the unit falls over, pull out the plug at 

once. 

 

 

 

 

 

 

 

 

 

 

9

Make  sure  the  inlet  and  outlet  ventilation  is  not 

blocked at any time. 

 

 

 

 

 

 

 

 

 

2

To  avoid  an  electric  shock,  avoid  placing  the  unit 

near window or in a bathroom. 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Do not operate this unit in an explosive or corrosive 

environment. 

6

Operate  this  unit  on  a  horizontal  surface  to  avoid 

vibration and noise. 

8

When  positioning,  ensure  there  is  30  cm  of  clear 

space on each side of the unit. 

 

 

 

 

 

 

 

 

 

 

10

Never allow water to spray onto the unit. Contact 

with water may cause malfunction and electric shock. 

 

 

 

 

 

 

 

 

 

 

Do not install and use the unit before carefully reading this instruction guide. Please 
retain this manual for product warranty and future reference.

 

 


background image

 

11

Never pull the plug with damp hands. 

 

 

 

 

 

 

 

 
15

Do not  place  any  foreign  objects  into  any  of  the 

openings of the unit. 

12

Always switch off at the socket before unplugging 

to avoid electric shock. 

13

When storing the unit, switch it off and unplug it, 

and ensure the water reservoir is emptied. 

14

Do not pull the power wire by force as it will cause 

damage to wire. 

 

16

Unplug the appliance during cleaning. 

 

 

 

Ambient Environment For Operating 

 
1. Working environment: 

Lowest ambient temperature 5

°

C, 40% RH. 

Highest ambient temperature 35

°

C, 90% RH. 

2.  Always  operate  the  unit  indoors,  e.g.  living  room,  bedroom,  etc.  Avoid  using  in  a  wet 

environment or outdoors. 

3. Before turning on the unit, ensure all doors and windows are closed. 
4. Ensure that the unit is placed on a stable and flat floor surface. If the floor surface is not even 

there is a risk that the unit may become unstable and topple over or excessive vibration and 
noise may occur. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

Component Diagrams 

 

     

 
 
 
 
 
 
 
 
 
         

 

Air deflector 

Control panel 

 


background image

Operating Introduction 

  Functions of Control Panel & Key Pads 

 

 

 

 

 

 

 

 

 

 

 

 

1. POWER: Switch the power button on the unit to start up. 
2.  Press  “mode”  to  select  the  desired  working  mode  and  the  corresponding 

indicator light will illuminate. 

3. Press “Setting” to select the desired running mode and ambient humidity. 
4. TIMER: Reserve & Turn Off hour settings. 

 

 

  LCD Monitor 

 

 


background image

  Operation Of Key Pads 

1. The unit will beep twice once plugged into the power socket. 

2. Press the “ON/OFF” button to turn on the unit. The deflector will startup automatically and at this point, 

the unit is in the status of constant dehumidifying and high speed running. 

     

1

The blue backlight will illuminate and turn off after 15 second.     

    2

The LCD display shows the working mode and status of unit.   

3

The LCD display shows the ambient humidity and temperature.   

4) Press the “ON/OFF” button again, the unit will stop working and the deflector close. 

 

3. MODE:   

Set up continuous & automatic dehumidifying modes and air speed by using the MODE key. Select or 

change  to  the  desired  mode  (the  indicator  light  will  illuminate  accordingly),  then  press  “Setting”  to 

change the running mode and automatic dehumidifying ratio. 

 

(1)  When  the  automatic  dehumidification  indicator            illuminates,  press  “Setting”  to  make  it 

circulate  among  60%RH-65%RH-70%RH-75%RH-80%RH-40%RH-45%RH-50%RH-55%RH 

-60%RH

·

·

·

·

·

 

 

1

When  entered  into  automatic  dehumidification,  if  you  press  “Setting”,  the  continuous 

dehumidifying mode will be cancelled. 

  2

Press “Mode” or three seconds after pressing “Setting”, the desired humidity ratio is set 

and the indicator light switches off. 

3

When sensor detected ambient humidity is 1% lower than your setting, compressor shut 

off and fan works at low speed. If ambient humidity is 5% higher than the setting, the 

dehumidification is activated again. 

 

 

(2) When the wind speed  

  indicator  illuminates,  press  “Setting”  to  select  your  desired  fan 

blower setting of “High speed” level or “Low speed” level. 

 

1)  It  shows  ‘L’  when  working  at  “Low  speed”  level  and  shows  ‘H’  when  working  at  “High 

speed” level. 

2) Press “Mode” or three seconds after pressing “Setting”, the wind speed is set. 

3) When the wind speed is set, dynamic patterns rotate. 

4) When the sensor detects that the ambient humidity is lower than your desired setting, the 

fan works at low speed. 

5) When the sensor detects that the ambient temperature exceeds 32

°

C, the fan works at 

the “High speed” level automatically. 

 

 

3

When the continuous dehumidification indicator          illuminates, press “Setting” to make the 

unit run at the continuous dehumidification mode. 

4. SETTING

 

When the indicator light illuminates according to your desired mode, pressing “Setting” will confirm the 

running mode or automatic dehumidifying ratio. 

 

 


background image

5. Press “TIMER”: 

    Press “TIMER” to set the working hours of the unit. 

 

1.  Time set for switching on: 

When the appliance is powered off or in standby mode, press Timer 1 to 24H or flexible 
working  time  to  set up  a required  operating  time. When  the  unit  reaches  the  requested 
time, the unit switches on and starts to work automatically. 

2.    Time set for shutdown: 

When the appliance is powered on, press Timer 1 to 24H or flexible working time to set the 
unit’s running hours. Once the time is set, the remaining hours are shown on the screen 
until time is up. 

3.    Please note: The memory function will not work when the timer is set for shutdown. 

 

  Automatic Defrosting 

A working cycle: When the appliance works in low temperatures, frost may appear on the surface of the 

evaporator. To ensure the unit performs well in these conditions, an automatic defrost function is fitted to 

the appliance.   

 

1

When a room temperature drops down to 16

  or less, the compressor works for 25 minutes 

dehumidifying then cuts off. The fan blower then keeps running for 7 minutes to defrost in   

2

  When  defrost

Symbol  of  defrost            displayed  on  LCD,  and  the  symbol  of 

dehumidification          goes out. 

3

  When defrost

Symbol of defrost displayed on LCD, the compressor is shut off, fan runs at 

high speed.   

 

  Water Tank Full Warning 

When the water tank is full, a buzzer will alarm 10 times (for about 5 seconds), and the symbol 

that 

indicates a full tank is displayed on LCD screen. Note all other symbols turn to orange and the appliance 

cuts out. At this point the water tank must be removed, emptied and reinstalled before the unit can operate 

again. The interval of dehumidifying lasts about 3 minutes because of the compressor protection. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Remove Water Reservoir as Arrow Direction 

 

 


background image

  Abnormal Compressor ‘ Warning’   

During  operation,  any  malfunction  can  trip  the  compressor  to  fail,  resulting  in  a  compressor  shut  off.  It 

takes 3 minutes to recover from the protection period. 

 

 

After  the  water  reservoir  is  removed  it  takes  about  3  minutes  to  start  up  the  unit  again  for 

protection  purposes.  To  avoid  this  protection  period,  simply  remove  the  plug  from  power 

socket to restart the unit. 

 

  Protection Of Extremely Low & High Temperature 

1. When the sensor on the air intake detects ambient temperature 

0ºC or 

40ºC, the appliance will shut off 

automatically for protection, and the warning beeps will continue with 3 long and 2 short signals. 

When the sensor detects ambient temperatures 

0ºC, 0ºC is showed on the LCD display. 

When the sensor detects ambient temperatures 

40ºC, 40ºC is showed on the LCD display. 

  2. When sensor on the evaporator detects its temperature 

40ºC, the appliance will shut off automatically 

for protection, and the symbol for automatic defrost            illuminates.     

 

1. If all function keys are not working, you should switch off at the mains to restart the unit. 
2. After the unit has experienced extremely low & high temperature, the appliance will not 
keep its memory function when restart. 

 

  Failures Of Humidity & Temperature Sensor 

1. When  an  error  between  the  humidity  and  temperature  sensor  occurs,  the  symbol  of  dehumidification       

will flash, and “0ºC” “0%RH” is displayed on the LCD display. At this point the appliance adopts the 

continuous dehumidifying mode. 

 

1

  If  the  temperature  sensor  malfunctions,  the  appliance  will  adopt  the  continuous 

dehumidification mode and not a controlled humidity setting.   

2

  This malfunction will not influence the dehumidification. 

 

2. When the temperature sensor of the evaporator is an open circuit or short circuit, the symbol of defrost       

 

    will  flash,  and  the  appliance  turns  to  dehumidifying  and  defrosting  mode:  dehumidifying  for  20 

minutes, then defrosting for 5 minutes.       

 

1

If the temperature sensor malfunctions, the keys within the control panel will perform normally. 

2

If the temperature sensor malfunctions, the appliance will continue to work with lower efficiency.   

 

  Memory Function 

If  the  power  supply  is  cut  off  when  the  appliance  is  running,  it  will  memorise  its  working  mode 

automatically. Once power has been restored, the appliance will restart and continue in this working 

mode.         

       

 

 


background image

 

1

The appliance will not run the memory function for manual & timing shutdown, in this instance 

the appliance will restart to run in its original state, not recover back to the last set mode.   

2

If the power supply is shut off into a protection mode, the appliance will not recover back to 

the last set mode. 

   

 

 

 

Continuous Drainage 

Remove water plug and connect with PVC hose with spigot. 

 

 

PVC hose must be placed on the ground flatly. 

Do not tangle the hose. 

Do not immerse the hose (outlet) end into another receptacle, as it may cause water flow 

      blockage. 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 


background image

Maintenance & Cleaning

 

 

◆ 

Before any maintenance or cleaning, please switch off and unplug the unit. 

◆ 

Do not place in direct sunlight, as the plastic casing may discolour.   

  Take care when removing the water tank. 

  Only use a soft clean cloth to clean this unit. Do not use gasoline, paint thinner or other chemicals to 

clean the unit. 

  Cleaning  mesh  filter:  Remove  the  filter  in  arrow  direction  (as  shown  on  figures).  Use  a  vacuum 

cleaner or water to clean, and then put it in ventilated place until it's dry. 

 

 

 

 

  Always switch off and unplug before moving this unit. 

  When packing away this unit for a long period of time switch off and unplug the unit, empty the water 

tank and leave to dry for two days. Then store it in a dry, ventilated place. 

  If you have any problems with your appliance, please approach your dealer. 

  We cannot be held responsible for any damage or injury caused by unauthorized action. 

  If this unit becomes defective, please dispose of it responsibly.   

 

 

 

 

 

 

 

 

 


background image

 

Specification 

 

Model 

WL-YL-2612B 

Power Rated 

220-240VAC/50Hz 

Moisture removal       

12 L/D    (30

  RH80%) 

Dehumidifying Power       

255W      (30

  RH80%) 

Max Power Dissipation

 

300W      (35

  RH90%) 

Dehumidifying Air Volume 

L:80m

3

/h              H:100 m

3

/h 

Refrigerant 

R134a      120g 

Capacity of Water Tank 

1.9L 

Unit Dimension:   