PDF User Manual

  1. Home
  2. Manuals
  3. marsden MSS-I-400 User Manual

marsden MSS-I-400 User Manual

Made by: marsden
Type: User Manual
Category: Scales
Pages: 13
Size: 0.83 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

 

 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

USER MANUAL 

   

MSS-I-400 

 

Please take time to read these 

instructions before starting 

to use the scale 

Version 1.0 01/17 

 


background image

 

Contents 

 
 

Product Specification 

 

 

 

 

 

Safety Instructions   

 

 

 

 

 

Before Using the Scale 

 

 

 

 

 

Operation: Basic Functions  

 

 

 

 

Operation: Advanced Functions   

 

 

 

Setting the Screensaver 

 

 

 

 

 

11 

Error Messages 

 

 

 

 

 

 

12 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

 

Page 2

 

 


background image

Product Specification 

 

 

Model 

Marsden MSS-I-400 

Capacity/Division 

3kg to 150kg x 1g to 20g 

Units of Measure 

Kg 

Function Keys 

HOLD, TOTAL, LB/KG, GROSS, TARE, ZERO, 
PRINT/ON/OFF 

Stabilization Time 

1-2 Seconds 

Operating Temperature 

-10 to 40°C 

Protection level 

IP5X

 

Power Supply 

6V4Ah battery 
Mains lead 

Indicator Display 

32mm LED display with 6 active digits 

Base Dimensions 

300mm x 300mm / 400mm x 400mm / 
600mm x 600mm 

 

 

Please note: Marsden’s policy is one of continuous development and therefore 

we reserve the right to change product specification without notice.   

Indicator images in this manual are for illustration purposes only. 

 

 

 

 

 

 

Page 3

 

 


background image

 

Safety Instructions 

 

Before putting this scale into use, please read with care the information given in this user 
manual, which contains important instructions for proper installation, use and maintenance 
of the device. 
 
Marsden/the manufacturer shall not be liable for damages arising from failure to heed the 
following instructions: 

 

When using electrical components under increased safety requirements, always 
comply with appropriate regulations. 

 

Inappropriate installation/use will render the warranty null and void. 

 

Ensure the voltage marked on the power supply unit matches your mains supply. 

 

This product is not waterproof. We do not recommend using the scale in humid, 
damp or wet environments. 

 

Observe the permissible ambient temperatures for use. 

 

The device meets the requirements for electromagnetic capability. Do not exceed 
the maximum values specified in the applicable standards. 

 
If you have any problems, contact Marsden/your local dealer/your service partner. 

 

Cleaning 

 

 

Please do not use corrosive liquids or large amounts of water to clean the scale. 

 

Always disconnect the scale from the mains power supply before cleaning. 

 

Maintenance 

 

 

The scale does not require any routine maintenance. However, we recommend 
checking the scale

s accuracy at regular intervals. If any inaccuracies occur, please 

contact your local dealer or service partner. 

 

You can book an accuracy check with the Marsden Service team on 01709 364296. 

 

 

 
 
 
 
 
 

Page 4

 

 


background image

 

Before using the Scale 

 

 

The scale’s indicator, the I

-400 

uses power from the 6V4Ah rechargeable battery, or can 

be powered from the mains lead which is hard wired into the indicator.

 

 

Once switched on, the scale is only ready to use once the display shows 0.000. 

 

Levelling the Scale 
 

The mild steel base is fitted with four adjustable levelling feet. Please adjust these accordingly 
to  ensure  the  base  is  level.  An  un-level  surface  for  weighing  could  result  in  inaccurate 
readings. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Page 5

 

 


background image

Operation: Basic Functions 

 

Switching the Scale on/off 

 

 

 

 

Press PRINT/ON/OFF to power-on the 

scale. When the scale shows 0.000 it 

is ready for weighing. 

 
 
 

To switch the scale off, press and hold 

PRINT/ON/OFF for three seconds. The 

scale will now power down. 

 

 

 

Setting the Scale to Zero 

 

 

 

 

If at any time the reading shows 

anything other than 0.000 when 

there is nothing on the scale, you can 

reset the display by pressing ZERO 

once.   

 
 
 
 
 
 
 
 

Page 6

 
 

 


background image

Operation: Advanced Functions 

 

Hold Function 

 

 

With the scale switched on, add an 

item to the base. 

 

 

Press HOLD once. The scale will lock 

onto and stabilise the weight reading 

for the item. The reading will remain 

displayed after the item is removed. 

 

 

Press HOLD again to disable the 

Hold function and return the scale to 

0.000. 

 

 

 

Tare Function 

 

 

Place the item you wish to deduct 

the weight of (such as a plate or 

bowl) on the scale and press TARE. 

 
 
 
 

Page 7

 
 

 


background image

 
 
 

 

 

The scale will show a minus reading. 

 

 

Weigh as normal and the negative 

weight reading will be deducted from 

the total weight. 

 

Press HOLD again to disable the 

Hold function and return the scale to 

0.000. 

 

 

 

Switching Between Kg and lb 

 

 

To switch the weight reading 

between kg and lb, press LB/KG.   

 

The LED panel will indicate whether 

the reading is showing in kg or lb as 

shown on the left. 

 
 
 
 

Page 8

 
 

 


background image

 

 

Counting Function 

 

 

To count items on the scale, first 

place a sample quantity on the scale. 

Switch the indicator to count mode 

by pressing TOTAL, holding the 

button until ‘SAMPLE’ is displayed

 

 

 

Press 

PRINT/ON/OFF. ‘PCS’ will 

display on the screen. 

 

Use the LB/KG and GROSS keys for 

left and right and TARE and ZERO as 

up and down to input the sample 

size.   

 

To confirm the amount, press 

PRINT/ON/OFF. Adding more items 

will increase the count on the display. 

 

Press HOLD to return to weighing 

mode. 

 

Page 9

 
 

 


background image

Accumulation Function 

 

 

You can use the scale to total up 

several loads. Add your first item to 

the scale and press TOTAL. Remove 

the item from the scale. 

 

 

Add the next item to the scale and 

press TOTAL again. 

 

If you would like to see the current 

total at any time, press and hold 

TOTAL for at least two seconds.   

 
 
 

 

 

To clear accumulated readings press 

ZERO. 

 

Press HOLD to return to normal 

weighing mode. 

 

 

Page 10

 
 

 


background image

Setting the Screensaver 

 

 

To save battery power, the screen can 

power off after a set period of time. 

To set the time out function, with the 

indicator switched on and nothing on 
the scale, press and hold down HOLD 

until ‘F1’ is displayed.

 

 

 

Press and 

hold ZERO until ‘F3’ is 

displayed. 

 

Press and hold PRINT/ON/OFF until 

‘F3.1’ is displayed.

 Press PRINT again. 

 
 

 

 

Using GROSS and ZERO, set the time 

out period you require (between 0 

and 99 minutes).     

 

Press PRINT/ON/OFF once and HOLD 

twice to set the time out period and 

return to normal weighing mode. 

 

Note: If the scale is inactive for 150 minutes or more, it will automatically power off. 

Page 11

 
 

 


background image

Error Messages 
 

Display 

Problem 

Solution 

 

 

 

 
 
 

Unable to reset after start 
up 

 
 

Ensure there is nothing on 

the scale when switching 

on 

 

Possible scale overload 

Remove weight from the 

scale 

 

Scale is below zero 

Press zero to re-zero the 

scale 

 

 
 

Out of balance range 

 
 

Remove any weight from 

the scale and try again 

 

Invalid operation 

 

 

EEPROM error 

Switch the scale on again; if 

the error message still 

shows, contact your 

dealer/Marsden 

 

AD initialization error 

Switch off the scale and 

restart. If the error occurs 

again, contact your 

dealer/Marsden 

 
 
 
 
 
 
 
 

 

Page 12

 

 


background image

 
 
 
 
 
 
 
 
 
 

Tel: 01709 364296 / 0800 169 2775 
Fax: 01709 364293 
E-mail: sales@marsdengroup.co.uk 
 

Manufacturing and Distribution: 

Unit 7, Centurion Business Park, 
Coggin Mill Way, 
Rotherham, 
S60 1FB 

Head Office: 

Unit 1, Genesis Business Park, 
Sheffield Road, 
Rotherham 
S60 1DX 

www.marsden-weighing.co.uk