Contents
1. Supplied with
A
2. Power supply
B
3. Operation
C
4. Safety notes
D
SUPPLIED WITH
A
· EasyTRACK for laser cross levels incl. 4 x AA alcaline batteries
· Receiver incl. 3 x AA alcaline batteries
· Case
· User manual
Technical data EasyTRACK
Centering accuracy TRACKING
± 1 mm
Working range radius
up to 50 m
(depending on the laser model used)
Instrument connection
5/8“ and 1/4“
Power supply / operating time
4 x AA alkaline / 15 h
Temperature range
-10°C up to +50°C
Dust / water protection
IP 54

11
EN
Technical data receiver
Accuracy
± 1 mm
Display
front, back, side LED
Temperature range
-10°C up to +50°C
Power supply / operating time
3 x AA alkaline / 50 h
Tones
3 (switchable)
Automatic shut-off
yes
Dust / water protection
IP 54
FEATURES
· The vertical laser line automatically aligns with the on-grade position of the receiver.
· Saves you time and money eliminating the need for manual alignment.
· One person can carry out this measuring job!
· 360° horizontal orientation in motorized mode
· Automatic axis alignment of the vertical line with on-grade postion of receiver
· Receiver can be used as remote control to position the laser line to any desired point
· Manual slow motion screw for axis alignment
· For line lasers with red and green beam
· Compatible with all geo-FENNEL line lasers with pulse function for receier use.
These are currently: CrossPointer5 SP, Geo5X-L360 HP, FL 66-Xtreme SP, FLG 64-GREEN HP,
FLG 66-Xtreme GREEN, FL 69 HP, FL 1000 HP.
B
POWER SUPPLY
BATTERIES OF THE EasyTRACK
Insert 4 x AA alkaline batteries into the two alkaline battery
cases on the bottom of the base (ensure correct polarity) and
lock both battery compartments.

12
EN
C
OPERATION
KEYPAD OF THE EasyTRACK
1. ON/OFF LED
2. ON/OFF button tribrach
Note:
When the ON/OFF LED flashes the batteries must be replaced.
2
1
RECEIVER
INSERT THE BATTERIES
Insert 3 x AA alkaline batteries into the battery case (ensure correct polarity) on the back; close the
battery case.
1. Circular bubble
2. Receiving window
3. Tube vial
4. Keypad
5. Receiving status indication
6. Side keypad
7. Battery case (back)
8. 1/4“-thread (back)
KEYPAD
1. ON/OFF sound / SHORT/LONG distance
2. LED SHORT/LONG distance
3. LED ON/OFF
4. ON/OFF receiver
5. LED Automatic function
6. Automatic function
7. RIGHT
8. LEFT
1
2
3
4
5
6
2
1
4
3
6
8
5
7

13
EN
OPERATION
First adjust the channel switch of the laser and the receiver to the same channel (you will find them in
the battery case of the receiver and of the base). Three channels (1, 2 and 3) are available. By using dif-
ferent channels several instruments can be operated on one construction site without any disturbances.
AUTOMATIC TRACKING FUNCTION
For the axis alignment (vertical line)
· Fix the line laser on the EasyTRACK
· Power on the line laser and activate the reception mode
· Position the line laser over the ground point
· Press the POWER button (2) of the EasyTRACK (the LED will light red)
· Power on the receiver (button 4)
· Select the distance LONG/SHORT with button (1): SHORT = 8 - 10 m, LONG = more than 10 m
· Position the on-grade mark of the receiver at the target point and power on AUTO (button 6); the
unit will now prepare the tracking procedure.
· Select the tracking directon with the arrow buttons LEFT or RIGHT.
The tracking procedure will start and a discontinuous beep will sound.
As soon as the laser line has reached the on-grade position of the receiver a permanent beep will sound
and the receving status indication of the display will light green.
In case the laser cannot find the on-grade position the procedure has failed and the receiver will beep
three times. Re-start the procedure with AUTO.
For a new on-grade position the procedure must be re-started with AUTO.

14
EN

15
EN
MANUAL USE (remote function)
The rotation can also be controlled manually.
For this press the buttons RIGHT/LEFT after having powered on the receiver in order to direct the
vertical line of the line laser to the required position.
In order to save energy the EasyTRACK can be powered off when the tracking procedure has been
completed.
After 10 minutes w/o use the EasyTRACK will power off automatically to save energy.
Without using the tracking function the receiver can be used in horizontal and vertical direction.
POWER ON
Press button (4) (the power LED will light red). Activate the pulse function (P) of the receiver.
Now the receiver is in reception mode and the sound is set to „low“. Press button (4) again to power off
the receiver. Three short beeps will sound.
Keep button (1) pressed to power on and off the sound.
· Keep it pressed once = sound ON - confirmation by a beep
· Keep it pressed twice = sound OFF - confirmation by two beeps
Move the receiver up and down
carefully
to detect the laser beam.
Detection of the laser signal:
A
Move the receiver down - acoustic signal: ultra-short frequent beep
B
Move the receiver up - acoustic signal: short frequent beep
C
On level - acoustic signal: continuous beep
USE OF THE RECEIVER WITHOUT TRACKING FUNCTION

16
EN
SAFETY NOTES
D
CARE AND CLEANING
Handle measuring instruments with care. Clean with soft cloth only after any use. If necessary damp
the cloth with some water. If the instrument is wet clean and dry it carefully. Pack it up only if it is per-
fectly dry. Transport in original container / case only.
ELECTROMAGNETIC ACCEPTABILITY (EMC)
It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation sys-
tems); will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial
facilities or radio transmitters).
CE-CONFORMITY
This instrument has the CE mark according to EN 61010-1:2010.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in
material and workmanship under normal use for a period of two (2) years from the date of purchase.
During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with
the same or similar model at manufacturers option), without charge for either parts or labour. In case
of a defect please contact the dealer where you originally purchased this product. The warranty will not
apply to this product if it has been misused, abused or altered. Without limiting the foregoing, leakage
of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
1. The user of this product is expected to follow the instructions given in the user manual. Although
all instruments left our warehouse in perfect condition and adjustment the user is expected to
carry out periodic checks of the product’s accuracy and general performance.
2. The manufacturer, or its representatives, assumes no responsibility of results of a faulty or
intentional usage or misuse including any direct, indirect, consequential damage, and loss of
profits.
3. The manufacturer, or its representatives, assumes no responsibility for consequential damage,
and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third
party and/or a usage in other than usual conditions.
4. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of
profits due to a change of data, loss of data and interruption of business etc., caused by using the
product or an unusable product.
5. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of
profits caused by usage other than explained in the user manual.
6. The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong
movement or action due to connecting with other products.

17
EN
SAFETY INSTRUCTIONS
· Follow up the instructions given in the user manual.
· Do not stare into the beam. The laser beam can lead to eye injury. A direct look into the beam (even
from greater distance) can cause damage to your eyes.
· Do not aim the laser beam at persons or animals.
· The laser plane should be set up above the eye level of persons.
· Use the instrument for measuring jobs only.
· Do not open the instrument housing. Repairs should be carried out by authorized workshops only.
Please contact your local dealer.
· Do not remove warning labels or safety instructions.
· Keep the instrument away from children.
· Do not use the instrument in explosive environment.
· The user manual must always be kept with the instrument.

geo-FENNEL GmbH
Kupferstraße 6
D-34225 Baunatal
Tel.
+49 561 / 49 21 45
Fax
+49 561 / 49 72 34
info@geo-fennel.de
www.geo-fennel.de
Technische Änderungen vorbehalten.
All instruments subject to technical changes.
Sous réserve de modifications techniques.
Precision by tradition.
10/2017