Thank you for purchasing the Cobra CPI 880
inverter. Properly used, this Cobra product will
give you many years of reliable service.

How Your Cobra Power Inverter Works

The Cobra power inverter is an electronic product that
has been designed and built to take low voltage DC (Direct
Current) power from your automobile or other low voltage
power supplies and convert it to standard 115 Volt AC
(Alternating Current) power like the current you have in
your home. This conversion process thereby allows you
to use many of your household appliances and electronic
products in automobiles, RVs, boats, tractors, trucks and
virtually anywhere else.

Customer Assistance

Should you encounter any problems with this product,
or not understand its many features, please refer to this
owner’s manual. If you require further assistance after
reading this manual, Cobra Electronics offers the
following customer assistance services:

For Assistance in the U.S.A.

Automated Help Desk

English only.

24 hours a day, 7 days a week 773-889-3087 (phone).

Customer Assistance Operators

English and Spanish.

8:00 a.m. to 6:00 p.m. CT, Monday through Friday
(except holidays) 773-889-3087 (phone).

Questions

English and Spanish.

Faxes can be received at 773-622-2269 (fax).

Technical Assistance

English only.

www.cobra.com (on-line: Frequently Asked Questions).
English and Spanish. productinfo

@

cobra.com (e-mail).

For Assistance Outside the U.S.A.

Contact Your Local Dealer

© 2008 Cobra Electronics Corporation

6500 West Cortland Street

Chicago, Illinois 60707 USA

www.cobra.com

Operating Instructions

800 WATT POWER INVERTER

CPI 880

Printed in China

Part No. 480-524-P

Version B

For more information or to

order any of our products,

please visit our website:

www.cobra.com

CB Radios

microTALK

®

Radios

Radar/Laser Detectors

Safety Alert

®

Traffic Warning Systems

Mobile GPS Navigation Systems

HighGear

®

Accessories

CobraMarine

®

VHF Radios

CobraMarine

®

Chartplotters

Power Inverters

Accessories

The Cobra line of quality
products includes:

Nothing

Comes Close to a Cobra

®

Nothing

Comes Close to a Cobra

®

 


background image

17

Maintenance

Very little maintenance is required to keep the inverter operating
properly. The exterior of the unit should be cleaned periodically
with a damp cloth to prevent accumulation of dust and dirt. At the
same time, tighten the screws on the DC input terminals. Be sure
vents and fans are free of dust or debris.

Product Service

If you have any questions about operating or installing your new
Cobra product, or if you are missing parts…

Please call Cobra first!
DO NOT RETURN THIS PRODUCT TO THE STORE!

See customer assistance on page A1

.

If your product should require factory service, please call Cobra
first before sending your power inverter. This will ensure the
fastest turn-around time on your repair. You may be asked to
send your power inverter to the Cobra factory.

It will be necessary to furnish the following to have the product
serviced and returned.

1.

For warranty repair include some form of proof-of-purchase,
such as a mechanical reproduction or carbon copy of a sales
receipt. If you send the original receipt, it cannot be returned.

2.

Send the entire product.

3.

Enclose a description of what is happening with the power
inverter. Include a typed or clearly printed name and address
of where the power inverter is to be returned.

4.

Pack power inverter securely to prevent damage in transit.
If possible, use the original packing material.

5.

Ship prepaid and insured by way of a traceable carrier
such as United Parcel Service (UPS) or Priority Mail
to avoid loss in transit to:

Cobra Factory Service
Cobra Electronics Corporation
6500 West Cortland Street
Chicago, Illinois 60707 USA.

6.

If the power inverter is in warranty, upon receipt of your power
inverter, it will either be repaired or exchanged depending on the
model. Please allow approximately three to four weeks before
contacting Cobra for status. If the power inverter is out of
warranty, a letter will automatically be sent informing you
of the repair charge or replacement charge.

If you have any questions, please call 773-889-3087 for assistance.

Maintenance and
Product Service

Customer Assistance

Nothing

Comes Close to a Cobra

®

Cooling Fan

A3

A2

Product Features

Introduction

Introduction

On/Off

Power Switch

AC Outlets

Negative Battery

Cable Terminal

(Black)

Positive Battery

Cable Terminal

(Red)

Features

Two AC Receptacles

Automatic Thermal
Protection/Shutdown

Reverse Polarity Protection

Low Battery Alarm

Low Battery Shutdown

Contents

Introduction

Our Thanks to You . . . . . . . . . . . . . . . . . . A1
Customer Assistance . . . . . . . . . . . . . . . . A1
Product Features . . . . . . . . . . . . . . . . . . . A2
Important Safety Information . . . . . . . . . . . 1
Quick Evaluation Before Installation . . . . . . 3

Installation

Installation Requirements . . . . . . . . . . . . . . 5
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connecting Cables . . . . . . . . . . . . . . . . . . . 7
Power Consumption . . . . . . . . . . . . . . . . . 10

Operation

Turning Your Inverter On or Off . . . . . . . . 11
Power and Protection Indicators . . . . . . . 12
Operating Limits . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting Guide . . . . . . . . . . . . . . . 14
Specifications . . . . . . . . . . . . . . . . . . . . . . 15

Warranty

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Customer Assistance

Maintenance . . . . . . . . . . . . . . . . . . . . . . . 17
Product Service . . . . . . . . . . . . . . . . . . . . 17

Protection &

Power Indicators

USB Outlet

 


background image

1

Introduction

Important Safety Information

Important Safety Information

Before installing and using your Cobra power inverter,
please read these general precautions and warnings.

Caution and Warning Statements

To make the most of this inverter, it must be installed and
used properly. Please read the installation and operating
instructions carefully before installing and using it. Special
attention must be paid to the

CAUTION

and

WARNING

statements in the manual.

CAUTION

Statements specify conditions which

could cause damage to the unit or other equipment.

WARNING

Statements identify conditions that

could result in personal injury or loss of life.

General Precautions

1. Never install the inverter in a boat’s

engine compartment where gas and
battery fumes are present.

2.

Do not operate the inverter if it has
been dropped or damaged in any way.

3.

Do not open the inverter; it contains no user-
serviceable parts. Attempting to service unit
could cause electrical shock.

NOTE

Internal components remain charged

after all power is disconnected.

4.

Do not expose the inverter to rain, snow,
bilge water or spray.

5.

Do not obstruct the ventilation openings.

6.

Do not install the inverter in zero-clearance
compartment.

CAUTION

This inverter should be used in

negative ground

applications only.

Nothing

Comes Close to a Cobra

®

 


background image

3

2

Important Safety Information

Introduction

WARNING

Power inverters contain components

that can produce arcs or sparks. To prevent fire
or explosion, do not install the inverter in areas or
compartments containing batteries or flammable
materials or in locations that require ignition-
protected equipment.

WARNING

To reduce the risk of fire, do not cover

or obstruct the ventilation openings. Do not install
inverter in zero-clearance compartment.

Warning: Wash Hands After Handling Power Cord

The power cord on this product contains lead, a chemical
known in the state of California to cause birth defects or
other reproductive harm.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries can be
damaged if connected to the Cobra 800 watt inverter. Two
particular types of equipment are prone to this problem:

1.

Small battery-operated
appliances such as flashlights,
razors, and night lights that
can be plugged directly into
an AC receptacle to recharge.

2.

Certain battery chargers for
battery packs used in hand
power tools. These chargers
have a

WARNING

label stating

that dangerous voltages are
present at the battery terminals.

This problem does not occur with the vast majority of
battery operated equipment. Most use a separate charger
or transformer that is plugged into the AC receptacle and
produces a low voltage output. If the label on the AC
adapter or charger states that it produces a low voltage
AC or DC output (less than 30 volts), the inverter will
have no problem powering the adapter safely.

Cobra 800 Watt Output Waveform

Some very sensitive electronic equipment may not operate
satisfactory on “square wave” or “modified sine wave.”
The output waveform is referred to as “square wave” or
“modified sine wave.” It is a stepped waveform designed
to have characteristics similar to the sine wave shape of
utility power. A waveform of this nature is suitable for most
AC loads (including linear and switching power suppliers
used in electronic equipment, transformers and motors).

Quick Evaluation Before Installation

This section provides you with basic information about the
inverter and how to check its performance before installation.

Be Sure to Have on Hand:

A 12 volt DC power source (such as a vehicle battery).

The power source must provide
between 11 and 15 volts DC and
be able to supply enough current to
run the test load. As a rough guide,
divide the wattage of the test load by
10 to get the current (in amperes)
the power source must deliver.

The provided two foot direct-to-battery 12 gauge cable.

Only use the cable provided with
your inverter.

A test load that can be plugged into the AC receptacle on
the inverter for short term testing at a low power level.

Quick Evaluation
Before Installation

Introduction

Nothing

Comes Close to a Cobra

®

Plug In Directly

Dangerous Voltages

Power Supply

Cable

Test Load

 


background image

5

4

Installation
Requirements

To check your inverter’s performance before installation:

1.

Turn the inverter

off

(see page 11

for details). If the power source
is a DC power supply, switch it

off

as well.

2.

Connect cables to power input
terminals (see page 7 for details).

3.

Connect cables to power source
(see page 7 for details).

4.

Check to make sure all
connections are secure.

5.

Turn the inverter

on

. If the

power source is a DC power
supply, switch it

on

first.

6.

Plug in the test load.

The inverter should supply
power to the load. If the inverter
is not working properly, refer to
the troubleshooting guide on
page 14 or power and protection
indicators section on page 12.

Installation Requirements

The inverter must be installed in an area that meets
all of the following requirements:

A. Dry

Do not place in an area where water can drip
or splash on the inverter.

B. Cool

Ambient air temperature should be between 30°F
and 105°F (0°C and 40°C). The cooler the better.

C. Ventilate

Allow at least one inch (three cm) of clearance around
the inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.

D. Safe

Do not install the inverter in the same compartment
as a battery or in any compartment that contains
flammable liquids such as gasoline.

E. Close to Battery

Install unit as close to battery as possible (without
being in the same compartment) to minimize the
length of cable required to connect the inverter to
the battery. It is better and cheaper to run longer
AC wires than longer DC wires (cables).

CAUTION

To avoid fire, do not cover or obstruct

ventilation openings. Do not install inverter in a zero-
clearance compartment. Overheating may result.

CAUTION

The inverter must only be connected to

batteries with a nominal output voltage of 12 volts.
It will not work with a 6 volt battery, and will be
damaged if it is connected to a 16 volt battery.

WARNING

This unit contains components which

can produce arcs or sparks. To prevent fire or
explosion, do not install in compartments containing
a battery or flammable materials, or in a location
which requires ignition protected equipment.

Installation

Quick Evaluation
Before Installation

Introduction

Nothing

Comes Close to a Cobra

®

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

USB Connection

Connect Test Load

 


background image

7

6

Mounting

To mount your inverter:

1.

Place the inverter on a flat surface with the
mounting bracket against the mounting surface.

2.

Mount to secure surface using mounting hardware
that is corrosion resistant (not included).

The inverter can be mounted horizontally or vertically.

Connecting Cables

Power wire and wiring are very important to the
performance of the inverter. Because the inverter has a
low voltage, high current input, low resistance wiring is
essential between the battery and inverter. This is so it
can deliver the maximum amount of energy to the load.

Only use the cables provided with your power inverter.

To connect the cables between the inverter
and the battery:

1.

Turn the

On/Off Switch

on the inverter to the

off

position. If the power source is a DC power supply,
switch it

off

as well.

2.

Connect cable to the

Power Input Terminals

on

right side panel of the inverter. The red terminal is
positive (+) and the black terminal is negative (-).
Insert the ends of the cables onto the terminals and
tighten the screws to clamp the cables safely.

Mounting

Connecting Cables

Installation

Installation

On/Off Switch to Off

Mounting Brackets

Mounting Hardware

Connect Cables

Nothing

Comes Close to a Cobra

®

 


background image

9

8

Connecting Cables

Connecting Cables

Installation

Installation

Connect Power Source

3.

Connect cable to the power source:

a.

Connect the cable from the

Negative (Black)

Terminal

of inverter to the

Negative Terminal

of

the power source. Make a secure connection.

b.

Connect the cable from the

Positive (Red) Terminal

of the inverter to the

Positive Terminal

of the power

source (the battery’s main fuse or the battery selector
switch, if you are using one). Make a secure connection.

You might observe a spark when you make this connection
since current can flow to charge capacitors in the inverter.

All power connections to your Cobra inverter must
be

Positive to Positive

and

Negative to Negative

.

CAUTION

Do not connect the inverter and another

AC source (such as a generator or utility power)
to the AC wiring at the same time. The inverter
will be damaged if its output is connected to
AC voltage from another source. Damage can
even occur if the inverter is switched

off

.

CAUTION

Do not connect the inverter to an AC

branch circuit that has high-power consumption loads.
It will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume
more than 800 watts.

CAUTION

Loose connectors result in excessive

voltage drop and may cause over heated wires
and melted insulation.

CAUTION

Reverse polarity connections (positive

to negative) will blow internal fuses in the inverter
and may permanently damage the unit. Such
damage is not covered by the warranty.

CAUTION

Remove any jewelry (watch, ring, etc.).

Be careful not to short circuit the battery with
any metallic object (wrench, etc.).

WARNING

115 volt AC power is potentially lethal.

Do not work on AC wiring when it is connected to
the inverter (even if it is switched off) unless the
DC power source is physically disconnected from
the inverter. Also, do not work on AC wiring if it is
connected to another AC power source such as
a generator or the utility line.

WARNING

You may observe a spark when making

the connection because current can flow to charge
the capacitors in the inverter.

Do not make this

connection in the presence of flammable fumes.

Explosion or fire may result. Thoroughly ventilate the
battery compartment before making this connection.

Nothing

Comes Close to a Cobra

®

 


background image

11

10

Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before
attempting to turn the unit

on

(see installation page 5).

To turn the power inverter on:

1.

If a DC power supply is being
used as the power source, switch
it

on

.

2.

On the left side panel, switch the

On/Off Switch

to

on

.

The inverter is now ready to deliver AC power to your loads.
If several loads are to be operated by the inverter, turn them

on

separately, after the inverter has been turned

on

. This

will ensure that the inverter does not have to deliver the
starting currents required for all the loads at once.

To turn the power inverter off:

1.

On the left side panel,
switch the

On/Off Switch

to

off

.

NOTE

The

On/Off Switch

turns the control circuit

in the inverter

on

and

off

. It

does not

disconnect

power from the inverter.

NOTE

When the switch is in the

off

position, the

inverter draws no current from the battery. When
it’s in the

on

position, but no power is being

supplied to the load, the inverter draws less than
500 milliamperes from the battery. This is low
current draw. It would take more than a week to
discharge a 100 ampere-hour battery at this rate
depending on the age of the battery.

Power Consumption

Installation

Power On and Off

Operation

Nothing

Comes Close to a Cobra

®

Power Consumption

For each piece of equipment you will be operating from the
inverter, you must determine the battery’s

reserve capacity

(how long the battery can deliver a specific amount of
current – in automotive batteries, usually 25 amperes) or

ampere-hour capacity

(a measure of how many amperes

a battery can deliver for a specified length of time).

Example – Reserve capacity:

a battery with a reserve

capacity of 180 minutes can deliver 25 amperes for
180 minutes before it is completely discharged.

Example – Ampere-hour capacity:

a battery with an

ampere-hour capacity of 100 ampere-hours can deliver
5 amperes for 20 hours before it is completely discharged.

To determine the battery ampere-hour
capacity you require:

1.

Determine how many watts each piece of equipment
consumes. This can normally be found on the product
label. If only the current draw is given, multiply the
current draw by 115 to get the watt consumption.

2.

Estimate the time (in hours) that each piece of equipment
will be running between battery charging cycles.

3.

Calculate the total watt-hours of energy consumption
(power x operating time) using the average power
consumption and the total estimated running time
(in hours).

Power x Operating Time = Watt-Hours

.

4.

Divide the watt-hours by 10 to determine how many
power supply’s (12 volt) ampere-hours will be consumed.

On/Off Switch to On

On/Off Switch to Off

Laptop

50 watts x 2 hours
= 100 watt-hours

TV/VCR (up to 25")

115 watts x 3 hours
= 345 watt-hours

Blender

300 watts x 15 minutes
= 75 watt-hours

 


background image

13

12

Power and Protection Indicators

The power and protection indicators include a green light,
a red light and an alarm.

Green Light

Power on

– The green light should remain

on

steady.

Red Light and/or Alarm

Current overload –

The red light will turn

on

momentarily,

then the inverter will shutdown. The inverter will continue
to check for appropriate current levels while trying to
restart the load.

DC input voltage overload –

The red light will turn on and

the inverter will shutdown. The inverter will continue to
check for appropriate voltage levels while trying to restart
the load.

DC input voltage shortage –

As a warning that the voltage

is getting low, the internal alarm will sound. When the
voltage is too low, the inverter will shutdown and the red
light will turn

on

. The inverter will continue to check for

appropriate voltage levels while trying to restart the load.

Temperature overload –

The red light will blink, then the

inverter will shutdown. The inverter will continue to check
for appropriate temperature levels while trying to restart
the load.

NOTE

A momentary sound of the internal alarm

and/or flash of the red light is normal at start up.

Power and
Protection Indicators

Operation

Operating Limits

Operation

Operating Limits

Power Output

The inverter can deliver 800 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
resume operation at 800 watts. Note: The wattage
rating applies to resistive loads.

The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps,
and other motor-operated equipment require very high
surge currents to start. The inverter may not be able
to start some of these motors even though their rated
current draw is within the inverter’s limits. The inverter
will normally start single phase induction motors rated
at one-half HP or less.

Input Voltage

The inverter will operate from input voltage ranging
from 10 volts to 15 volts. Optimum performance will
occur when the voltage is between 12 volts and 14 volts.
If the voltage drops below 10.5V+/-0.3V, an audible
low battery warning will sound. The inverter will shut
down if the input voltage drops below 9.5V+/-0.3V. This
protects the battery from being over-discharged. It will
restart when the input voltage exceeds 12V+/-0.3V.

The inverter will also shut down if the input voltage
exceeds 15.75V+/-0.75V. This protects the inverter
against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.

Nothing

Comes Close to a Cobra

®

 


background image

15

14

Troubleshooting Guide

Operation

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . 800W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 1600W
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load) . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F)

Storage temperature range . . . . . . . . . . . . -40°C – 85°C

(-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.

To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for
added safety.

Problem/Symptom

Low output voltage

No output voltage

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No output voltage

Low battery alarm
on all the time

Possible Causes

Overload

Low input voltage

Thermal
shutdown

High input
voltage

Short circuit

Inverter
switched

off

No power
to inverter

Reverse
DC polarity

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure
the inverter is
connected to
12V battery.

Check regulation
of charging system.

Check load for
proper operation.

Turn inverter

on

.

Check wiring
to inverter.

Observe
correct polarity.

Check
connections.

Make sure battery
is fully charged.

Troubleshooting Guide

Nothing

Comes Close to a Cobra

®

 


background image

16

Limited Two-Year Warranty

For Products Purchased in the U.S.A.

Cobra Electronics Corporation warrants that its Cobra power
inverter, and the component parts thereof, will be free of defects in
workmanship and materials for a period of two years from the date
of first consumer purchase. This warranty may be enforced by the
first consumer purchaser, provided that the product is utilized
within the U.S.A.

Cobra will, without charge, repair or replace, at its option, defective
power inverters, products or component parts upon delivery to the
Cobra Factory Service department, accompanied by proof of the
date of first consumer purchase, such as a duplicated copy of a
sales receipt.

You must pay any initial shipping charges required to ship the
product for warranty service, but the return charges will be at
Cobra’s expense, if the product is repaired or replaced under
warranty. This warranty gives you specific legal rights, and you
may also have other rights which may vary from state to state.

Exclusions:

This limited warranty does not apply.

1.

To any product damaged by accident.

2.

In the event of misuse or abuse of the product or
as a result of unauthorized alterations or repairs.

3.

If the serial number has been altered, defaced, or removed.

4.

If the owner of the product resides outside the U.S.A.

All implied warranties, including warranties of merchantability
and fitness for a particular purpose are limited in duration to the
length of this warranty. Cobra shall not be liable for any incidental,
consequential or other damages; including, without limitation, to
damages resulting from loss of use or cost of installation.

Some states do not allow limitations on how long an implied
warranty lasts and/or do not allow the exclusion or limitation
of incidental or consequential damages; so the above limitations
may not apply to you.

For Products Purchased Outside the U.S.A.

Please contact your local dealer for warranty information.

Trademark Acknowledgement

Cobra

®

, Nothing Comes Close to a Cobra

®

and the snake design

are registered trademarks of Cobra Electronics Corporation, USA.
Cobra Electronics Corporation™ is a trademark of Cobra
Electronics Corporation, USA.

Warranty and Trademark
Acknowledgement

Warranty