background image

A1 English

Our Thanks to You

 

 

Introduction

Thank you for purchasing the Cobra CPI 2550
inverter. Properly used, this Cobra product 
will give you many years of reliable service.

How Your Cobra Power Inverter Works

The Cobra power inverter is an electronic product that has
been designed and built to take low voltage DC (Direct
Current) power from your automobile or other low voltage
power supplies and convert it to standard 115 volt AC
(Alternating Current) power like the current you have in your
home. This conversion process thereby allows you 
to use many of your household appliances and electronic
products in automobiles, RVs, boats, tractors, trucks and
virtually anywhere else.

Customer Assistance 

Should you encounter any problems with this product, 
or not understand its many features, please refer to this owner’s
manual. If you require further assistance after reading this
manual, Cobra Electronics offers the 
following customer assistance services:

For Assistance in the U.S.A. 

Automated Help Desk 

English only. 

24 hours a day, 7 days a week 773-889-3087 (phone). 

Customer Assistance Operators 

English and Spanish. 

8:00 a.m. to 6:00 p.m. CT, Monday through Friday 
(except holidays) 773-889-3087 (phone). 

Questions 

English and Spanish. 

Faxes can be received at 773-622-2269 (fax). 

Technical Assistance 

English only. 

www.cobra.com (on-line: Frequently Asked Questions). 
English and Spanish. productinfo

@

cobra.com (e-mail).

For Assistance Outside the U.S.A. 

Contact Your Local Dealer

 

 

Customer Assistance

© 2007 Cobra

®

Electronics Corporation

6500 West Cortland Street

Chicago, Illinois 60707 USA

www.cobra.com

Operating Instructions

Nothing

Comes Close to a Cobra

®

English

2500 WATT POWER INVERTER

CPI 2550

Printed in China 

Part No. 480-200-P

Version B

Nothing

Comes Close to a Cobra

®

English

For more information or to 

order any of our products, 

please visit our website:

www.cobra.com

CB Radios

microTALK

®

Radios

Radar/Laser Detectors

Safety Alert

®

Traffic Warning Systems

Handheld GPS Receivers

Mobile GPS Navigation Systems

HighGear

®

Accessories

CobraMarine

®

VHF Radios

Power Inverters

Accessories

The Cobra line of quality 
products includes:

 


background image

Features

• 

Three AC Receptacles

• 

Current Meter

• 

Remote On/Off Capable

• 

Automatic Thermal
Protection/Shutdown

• 

Reverse Polarity Protection

• 

Low Battery Alarm

• 

Low Battery Shutdown

A3 English

A2 English

Product Features

 

 

Introduction

 

 

Introduction

 

 

 

 

 

 

 

 

 

 

AC Outlets

Current 

Meter

Positive Battery 

Cable Terminals

(Red)

Negative Battery 
Cable Terminals
(Black)

Ground
Terminal

Cooling Fans

Contents

Introduction

Our Thanks to You . . . . . . . . . . . . . . . . . . . . . A1
Customer Assistance  . . . . . . . . . . . . . . . . . . A1
Product Features  . . . . . . . . . . . . . . . . . . . . . A2
Important Safety Information  . . . . . . . . . . . . . 1
Quick Evaluation Before Installation  . . . . . . . . .4

Installation

Installation Requirements  . . . . . . . . . . . . . . . . 6
Mounting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting Cables  . . . . . . . . . . . . . . . . . . . . . 8
Power Consumption  . . . . . . . . . . . . . . . . . . . 12
Ground Wiring . . . . . . . . . . . . . . . . . . . . . . . . 13

Operation

Turning Your Inverter On or Off  . . . . . . . . . . . 14
Remote On/Off Switch  . . . . . . . . . . . . . . . . . 15
Power and Protection Indicators  . . . . . . . . . . 16
Operating Limits  . . . . . . . . . . . . . . . . . . . . . . 17
Troubleshooting Guide  . . . . . . . . . . . . . . . . . 18
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . 19

Warranty

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Customer Assistance

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . .21
Product Service  . . . . . . . . . . . . . . . . . . . . . . 21
Optional Accessories   . . . . . . . . . . . . . . . . . . 22
Accessories Ordering Info   . . . . . . . . . . . . . . 22

On/Off Power 

Switch

Remote 

On/Off 
Switch 

Jack

Power & Protection

Indicators

 


background image

 

 

1

Nothing Comes close to a Cobra

®

 

 

Introduction

Important Safety Information

Important Safety Information

Before installing and using your Cobra power inverter, 
please read these general precautions and warnings.

Caution and Warning Statements

To make the most of this inverter, it must be installed and
used properly. Please read the installation and operating
instructions carefully before installing and using it. Special
attention must be paid to the 

CAUTION

and 

WARNING

statements in the manual. 

CAUTION

Statements specify conditions which 

could cause damage to the unit or other equipment. 

WARNING

Statements identify conditions that 

could result in personal injury or loss of life.

General Precautions

1. Never install the inverter in a boat’s engine compartment

where gas and battery fumes are present.

2.

Do not operate the inverter if it has been 
dropped or damaged in any way.

3.

Do not open the inverter; it contains no 
user-serviceable parts. Attempting to service 
unit could cause electrical shock.

NOTE

Internal components remain 

charged after all power is disconnected.

4.

Do not expose the inverter to rain, snow, 
bilge water or spray.

5.

Do not obstruct the ventilation openings.

6.

Do not install the inverter in zero-clearance compartment.

CAUTION

This inverter should be used in 

negative ground

applications only.

 

 

 

 

CAUTION

 

 

 


background image

 

 

3

Nothing Comes Close to a Cobra

®

2

English

Important Safety Information

 

 

Introduction

WARNING 

Power inverters contain components 

that tend to produce arcs or sparks. To prevent 
fire or explosion, do not install the inverter in 
areas or compartments containing batteries or
flammable materials or in locations that require
ignition-protected equipment.

WARNING

To reduce the risk of fire, do not cover 

or obstruct the ventilation openings. Do not install
inverter in zero-clearance compartment.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries 
can be damaged if connected to the Cobra 2500 watt inverter.
Two particular types of equipment are 
prone to this problem: 

1.

Small battery-operated appliances
such as flashlights, razors, and night
lights that can be plugged directly
into an AC receptacle to recharge.

2.

Certain battery chargers for battery
packs used in hand 
power tools. These chargers have a

WARNING

label stating that

dangerous voltages are present 
at the battery terminals.

This problem does not occur with the vast majority of battery
operated equipment. Most use a separate charger or
transformer that is plugged into the AC receptacle and
produces a low voltage output. If the label on the AC adapter
or charger states that it produces a low voltage 
AC or DC output (less than 30 volts), the inverter will 
have no problem powering the adapter safely.

Cobra 2500 Watt Output Waveform

Some very sensitive electronic equipment may not 
operate satisfactory on “square wave” or “modified 
sine wave.” The output waveform is referred to as 
“square wave” or “modified sine wave.” It is a stepped
waveform designed to have characteristics similar 
to the sine wave shape of utility power. A waveform 
of this nature is suitable for most AC loads (including 
linear and switching power suppliers used in electronic
equipment, transformers and motors).

Plug In Directly

Dangerous Voltages

Important Safety Information

 

 

Introduction

 


background image

5

Nothing Comes Close to a Cobra

®

4

English

Quick Evaluation

 

 

Introduction

Quick Evaluation

 

 

Introduction

Quick Evaluation Before Installation

This section provides you with basic information about 
the inverter and how to check its performance before
installation.

Be sure to have on hand:

£

A 12 volt DC power source (such as a vehicle battery).

The power source must provide
between 11 and 15 volts DC and be
able to supply enough current to run
the test load. As a rough guide, divide
the wattage of the test load by 10 to
get the current (in amperes) the power
source must deliver.

£

A set of cables to connect the power source to the inverter
(not included).

The cables must be as short and thick as possible in order
to reduce the voltage drop between the power source and
the inverter when drawing current from 
the power source. 

If the cable suffers an excessive voltage drop, the inverter
may shut down when drawing higher currents because the
voltage at the inverter dropped below 10 volts. 

#4 AWG stranded copper cable is recommended. It should
be no longer than four feet (one and one-half meters). 

The end of the cable that connects to the inverter must have
its insulation stripped off for about one-half inch (one and
one-half cm) back from the end, exposing the bare copper. 

The other end of the cable, which connects to the power
source, must be terminated with a lug or other connector that
provides a secure, low resistance connection. 

For example, if the power source is a battery, the cable
must be terminated with a battery terminal that clamps to
the post on the battery. 

£

A test load that can be plugged into the AC receptacle on the
inverter for short term testing at a low power level. The
following cables are recommended for testing low power
level test loads only.

Test Load 

Minimum

Power

Cable Size

100W

# 16 AWG copper

250W

# 12 AWG copper

500W

# 8 AWG copper

To check your inverter’s performance before installation:

1. 

Turn the inverter 

off

(see page 14 for

details). If the power source is a DC
power supply, switch it 

off

as well.

2. 

Connect cables to power input
terminals (see page 8 for details).

3. 

Connect cables to power source (see
page 8 for details).

4. 

Check to make sure all connections
are secure.

5. 

Turn the inverter 

on

. If the 

power source is a DC power supply,
switch it 

on

first.

6. 

Plug in the test load.

The inverter should supply power 
to the load. If the inverter is not
working properly, refer to the
troubleshooting guide on page 18 
or power and protection indicators
section on page 16.

Power Supply

Test Load

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

Connect Test Load

 

 

 

 

 


background image

 

 

 

 

7

Nothing Comes Close to a Cobra

®

6

English

Mounting

Installation Requirements

The inverter must be installed in an area that meets 
all of the following requirements:

A. Dry

Do not place in an area where water can drip 
or splash on the inverter.

B. Cool

Ambient air temperature should be between 30°F 
and 105°F (0°C and 40°C). The cooler the better.

C. Ventilate

Allow at least one inch (three cm) of clearance around the
inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.

D. Safe

Do not install the inverter in the same compartment 
as a battery or in any compartment that contains 
flammable liquids such as gasoline.

E. Close to Battery

Install unit as close to battery as possible (without being in
the same compartment) to minimize the 
length of cable required to connect the inverter to 
the battery. It is better and cheaper to run longer 
AC wires than longer DC wires (cables).

CAUTION

To avoid fire, do not cover or obstruct

ventilation openings. Do not install inverter in a zero-
clearance compartment. Overheating may result.

CAUTION

The inverter must only be connected to

batteries with a nominal output voltage of 12 volts. 
It will not work with a 6 volt battery, and will be
damaged if it is connected to a 16 volt battery.

WARNING

This unit contains components 

which can produce arcs or sparks. To prevent 
fire or explosion, do not install in compartments
containing a battery or flammable materials, 
or in a location which requires ignition 
protected equipment.

WARNING

This unit is suitable for installation 

in negative ground applications only. Do not attempt to
install to a positive ground application.

Mounting

To mount your inverter:

1.

Place the inverter on a flat surface with the 
mounting bracket against the mounting surface.

2.

Mount to secure surface using mounting hardware 
that is corrosion resistant (not included).

The inverter can be mounted horizontally or vertically.

 

 

Installation

Mounting Brackets

Mounting Hardware

Installation 

Requirements

 

 

Installation

 


background image

9

Nothing Comes Close to a Cobra

®

8

English

Connecting Cables (not included)

Power wire and wiring are very important to the performance of
the inverter. Because the inverter has a low voltage, high
current input, low resistance wiring is essential between the
battery and inverter. This is so it can deliver the maximum
amount of energy to the load. 

Use only copper wire. Aluminum wire has about one-third
more resistance than copper wire of the same size, plus it is
difficult to make good, low-resistance connections to
aluminum wire.

We recommend two #4 AWG copper cables (90°C insulation
rating) as the minimum size for connections between the
battery and inverter.

Keep the cable length as short as possible, no more than
four feet (one and one-half meters). This will keep the
voltage drop to a minimum.

If the cable has too much voltage drop, the inverter 
may shut down when drawing higher currents because
voltage at the inverter may drop below 10 volts. If you must
use longer cables, choose thicker cables, such as #2 AWG,
and trim the ends of the cable to fit the terminals.

To connect the cables between the inverter 
and the battery:

1. 

Turn the 

On/Off Switch

on the inverter to the 

off 

position. If

the power source is a DC power supply, switch it 

off

as

well.

2. 

On the end of the cable that connects to the inverter, strip
back the insulation about one-half inch (one and one-half
cm), exposing the bare copper conductor.

3. 

Connect cables to the 

Power Input Terminals

on right side

panel of the inverter. The red terminals are positive (+) and
the black terminals are negative (-). Insert the bare ends of
the cables into the terminals and tighten the screws to
clamp the wires safely.

4. 

Connect cables to the power source:

a.

Connect each cable from the 

Negative (Black) Terminals

of inverter to the 

Negative Terminal

of the power source. Make a secure connection. 

b.

Connect each cable from the 

Positive (Red) Terminals

of

the inverter to the 

Positive Terminal

of the power source (the battery’s main fuse or 
the battery selector switch, if you are using one). Make
a secure connection.

Connecting Cables

Connecting Cables

 

 

Installation

 

 

Installation

On/Off Switch to Off

Strip the Insulation

Insert Bare Cables

Connect Cables

 

 

 


background image

 

 

 

 

11

Nothing Comes Close to a Cobra

®

10 English

You might observe a spark when you make this connection, since
current can flow to charge capacitors in the inverter. 

All power connections to your Cobra inverter must be 

Positive

to Positive

and 

Negative to Negative

.

CAUTION

Electrical installations must meet 

local and national wiring codes, and should 
be performed by a qualified electrician.

CAUTION 

Do not connect the inverter and another AC

source (such as a generator or utility power) 
to the AC wiring at the same time. The inverter 
will be damaged if its output is connected to AC
voltage from another source. Damage can even occur
if the inverter is switched 

off

.

CAUTION

Do not connect the inverter to an AC branch

circuit that has high-power consumption loads. It will
not operate electric heaters, air conditioners, stoves,
and other electrical 
appliances that consume more than 2500 watts.

CAUTION

Loose connectors result in excessive voltage

drop and may cause over heated wires 
and melted insulation.

CAUTION 

Reverse polarity connections (positive 

to negative) will blow internal fuses in the inverter and
may permanently damage the unit. Such damage is not
covered by the warranty.

CAUTION

We recommend a main fuse in the battery’s

positive cable to protect against DC 
wiring short circuits (external to the inverter). 
The fuse should be as close to the battery as possible.
We recommend a Buss Fuse ANL-250 
or equivalent. The specific fuse ampere rating should
be sized to allow operation of all your 
DC powered equipment.

CAUTION 

Remove any jewelry (watch, ring, etc.). 

Be careful not to short circuit the battery with any
metallic object (wrench, etc.).

WARNING

If you are making a permanent AC connection

to the inverter, make sure that the 
AC wiring steps are performed before any DC wiring is
done. (DC hook-up energizes internal components,
regardless of the position of the 

On/Off Switch

). Working on AC connections in such 

a circumstance may result in an electric shock.

WARNING

115 volt AC power is potentially lethal. 

Do not work on AC wiring when it is connected to 
the inverter (even if it is switched 

off

) unless the 

DC power source is physically disconnected from 
the inverter. Also, do not work on AC wiring if it 
is connected to another AC power source such 
as a generator or the utility line.

WARNING

You may observe a spark when 

making the connection because current can 
flow to charge the capacitors in the inverter. 

Do not make this connection in the presence 
of flammable fumes.

Explosion or fire may 

result. Thoroughly ventilate the battery compartment
before making this connection.

NOTE 

If only one power source is used, connect both

cables from the negative terminal of the inverter to the
negative terminal of the power source. Then connect
both cables from the positive terminals of the inverter to
the positive terminal of the power source.

Connecting Cables

Connecting Cables

 

 

Installation

 

 

Installation

 

 

 


background image

13

Nothing Comes Close to a Cobra

®

12 English

Power Consumption

For each piece of equipment you will be operating from the
inverter, you must determine the battery’s 

reserve capacity

(how long the battery can deliver a specific amount of current —
in automotive batteries, usually 25 ampere) 
or 

ampere-hour capacity 

(a measure of how many amperes a

battery can deliver for a specified length of time). 

Example – Reserve capacity:

a battery with a reserve

capacity of 180 minutes can deliver 25 ampere for 
180 minutes before it is completely discharged.

Example – Ampere-hour capacity:

a battery with an

ampere-hour capacity of 100 ampere-hours can deliver 5
ampere for 20 hours before it is completely discharged.

To determine the battery ampere-hour 
capacity you require:

1. 

Determine how many watts each piece of equipment
consumes. This can normally be found on the product label.
If only the current draw is given, multiply the current draw
by 115 to get the watt consumption.

2. 

Estimate the time (in hours) that each piece of equipment will
be running between battery charging cycles.

3.

Calculate the total watt-hours of energy consumption
(power x operating time) using the average power
consumption and the total estimated running time 
(in hours). 

Power x Operating Time = Watt-Hours

.

4.

Divide the watt-hours by 10 to determine how many power
supply’s (12 volt) ampere-hours will be consumed.

Ground Wiring

There is a screw on the rear panel for 

Chassis Ground

. This is

to connect the chassis of the inverter to ground.

The 

Chassis Ground Screw

must be connected to a grounding

point, which will vary depending on where 
the unit is installed. Use a #8 AWG copper wire 
(preferably with green/yellow insulation) to connect 
the chassis ground screw to the grounding point.

In a vehicle:

Connect the 

Chassis Ground

to the 

chassis of the vehicle. 

In a boat:

Connect to the 

Boat Grounding System

In a fixed location:

Connect the 

Chassis Ground Screw 

to

earth ground by connecting to a ground rod (a metal rod
pounded into the earth) or other proper service entrance
ground.

Chassis Ground

Power Consumption

Ground Wiring

 

 

Installation

 

 

Installation

 

 

Laptop

50 watts x 2 hours 
= 100 watt-hours

TV/VCR (up to 25")

115 watts x 3 hours
= 345 watt-hours

Blender

300 watts x 15 minutes 
= 75 watt-hours

 


background image

15

Nothing Comes Close to a Cobra

®

14 English

Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before
attempting to turn the unit 

on

(see installation page 6).

To turn the power inverter on:

1.

If a DC power supply is being used as the power source,
switch it 

on

2.

On the left side panel, switch the 

On/Off Switch

to 

on

.

The inverter is now ready to deliver AC power to your loads. If
several loads are to be operated by the inverter, turn them 

on

separately, after the inverter has been turned 

on

. This will

ensure that the inverter does not have to deliver the starting
currents required for all the loads at once.

To turn the power inverter off:

1.

On the left side panel, switch the 

On/Off Switch

to 

off

.

NOTE

The 

On/Off Switch

turns the control circuit 

in the inverter 

on

and 

off

. It 

does not

disconnect

power from the inverter.

When the switch is in the 

off 

position, the inverter 

draws no current from the battery. When it’s in the 

on 

position, but no power is being supplied to the load,

the inverter draws less than 500 milliamperes from the
battery. This is low current draw. It would take more
than a week to discharge a 100 ampere-hour battery at
this rate depending on the age of the battery. 

Remote On /Off Switch (not included)

An optional 

Remote On/Off Switch

(not included) can be

connected to the 

Remote Jack

allowing you to turn the 

Cobra power inverter 

on

or 

off

from a convenient location when

the inverter is installed in an out of reach location.

Power On and Off

 

 

Operation

Remote On /Off Switch

 

 

Operation

On/Off Switch to On

Remote Switch

Remote Jack

On/Off Switch to Off

 

 

 

 

 

 

 

 

 


background image

17

Nothing Comes Close to a Cobra

®

16 English

Power and Protection

Indicators

 

 

Operation

Operating Limits

 

 

Operation

Power and Protection Indicators

The power and protection indicators include a green light, a
red light, an alarm and a current meter.

Green Light

Power on

– The green light should remain 

on

steady. 

Red Light and/or Alarm

Current overload – 

The red light will turn 

on

momentarily, then

the inverter will shutdown. The inverter will continue to check
for appropriate current levels while trying to restart the load.

DC input voltage overload – 

The red light will turn 

on

and the

inverter will shutdown. The inverter will continue to check for
appropriate voltage levels while trying to restart the load.

DC input voltage shortage – 

As a warning that the voltage is

getting low, the internal alarm will sound. When the voltage is
too low, the inverter will shutdown and the red light will turn

on

. The inverter will continue to check for appropriate voltage

levels while trying to restart the load.

Temperature overload – 

The red light will turn 

on

momentarily, then the inverter will shutdown. The inverter will
continue to check for appropriate temperature levels and the
red light will continue to blink while trying to restart the load.

NOTE

A momentary sound of the internal alarm and/or

flash of the red light is normal at start up.

Current Meter 

The current meter indicates the
current drawn from the battery. 
It will not indicate the current 
drawn by other loads also connected
to the battery.

For long term operation, the 
current meter should remain in 
the middle of the bar graph.

Operating Limits

Power Output

The inverter can deliver 2500 watts for about 60 minutes. The
inverter must cool for 15 minutes before it can resume
operation at 2500 watts. Note: The wattage 
rating applies to resistive loads.

The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps, and
other motor-operated equipment require very high surge
currents to start. The inverter may not be able to start some of
these motors even though their rated 
current draw is within the inverter’s limits. The inverter 
will normally start single phase induction motors rated 
at one-half HP or less.

Input Voltage

The inverter will operate from input voltage ranging 
from 10 volts to 15 volts. Optimum performance will occur
when the voltage is between 12 volts and 14 volts. If the
voltage drops below 10.5V+/-0.3V, an audible low battery
warning will sound. The inverter will shut down if the input
voltage drops below 9.5V+/-0.3V. This protects the battery
from being over-discharged. It will restart when the input
voltage exceeds 12V+/-0.3V.

The inverter will also shut down if the input voltage exceeds
15.75V+/-0.75V. This protects the inverter 
against excessive input voltage. Although the inverter 
has protection against over-voltage, it may still be damaged if
the input voltage were to exceed 16 volts.

No Plugs at 0%

One Plug at 40%

 

 

 


background image

19

Nothing Comes Close to a Cobra

®

Specifications 

 

 

Operation

Specifications

Continuous output power (1 hour)  . . . . . . . . . . . . . . 2500W
Surge rating (0.1 second)  . . . . . . . . . . . . . . . . . . . . . 5000W
Peak efficiency (12V – 1⁄2 load)  . . . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V)  . . . . . . . . . . . . . . . . . . . . . > 83%
No load current draw  . . . . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load)  . . . . . . Modified sine wave
Output frequency  . . . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
Input voltage  . . . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload)  . . . . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload)  . . . . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range  . . . . . . . . . . . . . . 0°C – 40°C 

(32°F – 104°F)

Storage temperature range  . . . . . . . . . . . . . . -40°C – 85°C 

(-40°F – 185°F)

Protection  . . . . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage 

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted after
low voltage protection, the voltage of DC input should be
above 12V. 

To extend the life of the fan, it will stop when there is no load.
The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for added
safety.

18 English

Troubleshooting Guide

 

 

Operation

Problem/Symptom

Low output voltage 

No output voltage 

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No output voltage

Low battery alarm
on all the time

Possible Causes

Overload 

Low input voltage

Thermal 
shutdown

High input 
voltage

Short circuit

Inverter 
switched 

off

No power 
to inverter

Reverse 
DC polarity

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter 
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure 
the inverter is
connected to 
12V battery.

Check regulation 
of charging system.

Check load for
proper operation.

Turn inverter 

on

.

Check wiring 
to inverter.

Observe 
correct polarity.

Check connections.

Make sure battery 
is fully charged.

Troubleshooting Guide

 


background image

21

Nothing Comes Close to a Cobra

®

Maintenance

Very little maintenance is required to keep the inverter operating
properly. The exterior of the unit should be cleaned periodically with a
damp cloth to prevent accumulation of dust and dirt. At the same time,
tighten the screws on the DC input terminals. Be sure vents and fans
are free of dust or debris.

Product Service

If you have any questions about operation or installing your new
Cobra product, or if you are missing parts…

Please call Cobra first! 
DO NOT RETURN THIS PRODUCT TO THE STORE! 

See customer assistance on page A1.

If your product should require factory service, please call Cobra first
before sending your power inverter. This will ensure the fastest turn-
around time on your repair. You may be asked to 
send your power inverter to the Cobra factory. 

It will be necessary to furnish the following to have the product
serviced and returned.

1.

For warranty repair include some form of proof-of-purchase, such as
a mechanical reproduction or carbon copy of a sales receipt. If you
send the original receipt, it cannot be returned.

2.

Send the entire product.

3.

Enclose a description of what is happening with the power inverter.
Include a typed or clearly printed name and address 
of where the power inverter is to be returned.

4.

Pack power inverter securely to prevent damage in transit. 
If possible, use the original packing material.

5.

Ship prepaid and insured by way of a traceable carrier such as 
United Parcel Service (UPS) or Priority Mail to avoid loss in transit to: 

Cobra Factory Service
Cobra Electronics Corporation
6500 West Cortland Street
Chicago, Illinois 60707 USA.

6.

If the power inverter is in warranty, upon receipt of your power
inverter, it will either be repaired or exchanged depending on the
model. Please allow approximately three to four weeks before
contacting Cobra for status. If the power inverter is out of warranty, a
letter will automatically be sent informing you 
of the repair charge or replacement charge. 

If you have any questions, please call 773-889-3087 for assistance.

Maintenance and 

Product Service

 

 

Customer Assistance

20 English

Limited Two-Year Warranty 

For Products Purchased in the U.S.A.

Cobra Electronics Corporation warrants that its Cobra power inverter,
and the component parts thereof, will be free of defects in
workmanship and materials for a period of two years from the date of
first consumer purchase. This warranty may be enforced by the first
consumer purchaser, provided that the product is utilized within the
U.S.A. 

Cobra will, without charge, repair or replace, at its option, defective
power inverters, products or component parts upon delivery to the Cobra
Factory Service department, accompanied by proof of the date of first
consumer purchase, such as a duplicated copy of a sales receipt. 

You must pay any initial shipping charges required to ship the product
for warranty service, but the return charges will be at Cobra’s expense,
if the product is repaired or replaced under warranty. This warranty
gives you specific legal rights, and you may also have other rights
which may vary from state to state.

Exclusions: 

This limited warranty does not apply:

1.

To any product damaged by accident.

2.

In the event of misuse or abuse of the product or as a result 
of unauthorized alterations or repairs.

3.

If the serial number has been altered, defaced, or removed.

4.

If the owner of the product resides outside the U.S.A.

All implied warranties, including warranties of merchantability 
and fitness for a particular purpose are limited in duration to the length
of this warranty. Cobra shall not be liable for any incidental,
consequential or other damages; including, without limitation, to
damages resulting from loss of use or cost of installation. 

Some states do not allow limitations on how long an implied warranty
lasts and/or do not allow the exclusion or limitation 
of incidental or consequential damages, so the above limitations may
not apply to you.

For Products Purchased Outside the U.S.A.

Please contact your local dealer for warranty information.

Trademark Acknowledgement 

Cobra

®

, Nothing Comes Close to a Cobra

®

and the snake 

design are registered trademarks of Cobra Electronics 
Corporation, USA. Cobra Electronics Corporation™ is a 
trademark of Cobra Electronics Coproration, USA.

Warranty and Trademark

Acknowledgement

 

 

Warranty

 


background image

23

Nothing Comes Close to a Cobra

®

22 English

Optional Accessories

You can find quality Cobra products and accessories at your local 
Cobra dealer, or in the U.S.A., you can order directly from Cobra.

Ordering from U.S.A.

Call 773-889-3087 for pricing or visit www.cobra.com.

For credit card orders

, complete and return this order form to 

fax number 773-622-2269. Or call 773-889-3087 (Press 1 from 
the main menu) 8:00 a.m. to 6:00 p.m. CT, Monday through Friday.

Make check or money order payable to: 
Cobra Electronics, Attn: Accessories Dept.
6500 West Cortland Street, Chicago, IL 60707 USA

To order online

, please visit our website: www.cobra.com

An optional 

Remote On/Off Switch

can be

connected to the 

Remote Jack

allowing you to

turn the Cobra CPI 2550 inverter 

on

or 

off

from

a convenient location when the inverter 
is installed in an out of reach location.

Remote On/Off
Switch (CPI A20)

Optional Accessories 

Accessories Ordering

Info 

 

 

Customer Assistance

 


background image

25

Nothing Comes Close to a Cobra

®

24 English