CA1516KR, CA1826KR, CA2326KR
Room Air Conditioner

Installation and Operating

Instructions

Fig. 1

---

Remote Control Unit

NOTE TO EQUIPMENT OWNER:

Thank you very much for purchasing a Climette Airconditioner. Please read this Owner’s

Information Manual carefully before installing and using this appliance and keep this manual

for future reference.
For your convenience, please record the model and serial numbers of your new equipment

in the spaces provided. This information, along with the installation data and dealer contact

information, will be helpful should your system require maintenance or service.

UNIT INFORMATION

Model # _____________________________________
Serial # ______________________________________

INSTALLATION INFORMATION

Date Installed ________________________________

DEALERSHIP CONTACT INFORMATION

Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________

Part Number 421 02 91

2

0 00   -  Printed 02/08

 


background image

2

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTRICAL SPECIFICATIONS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TIPS BEFORE INSTALLATION

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

POWER SUPPLY CORD

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION INSTRUCTIONS

6 -- 9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

STORM WINDOW APPLICATIONS

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WALL INSTALLATIONS

10 -- 11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MASONRY CONSTRUCTION

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OPERATING INSTRUCTIONS

12 -- 13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CARE AND MAINTENANCE

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING GUIDE

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WARRANTY

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 


background image

3

SAFETY CONSIDERATIONS

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instructions or

manuals, be alert to the potential for personal injury.
Understand these signal words: DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which

will

result in

severe personal injury or death. WARNING signifies hazards

which

could

result in personal injury or death. CAUTION is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage. NOTE is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

Thank you for choosing this room air conditioner to cool your
home. This Owner’s Information Manual provides information

necessary for the proper care and maintenance of your new room

air conditioner.
If properly maintained, your air conditioner will give you many

years of trouble free operation. To avoid installation difficulties,
read instructions completely before starting. This manual contains

information for the installation and operation of your room air
conditioner.

Exterior

Air Inlet

Power Cord

Cabinet

Air Outlet

Outdoor Air

Vent Lever

Control Panel

Front Panel

Interior

Air Inlet

Grille

Air Filter

Remote Control

A06528

Control Panel

  Fa n

Speed

Mode

Timer

Airconditioner

Remote Control

Power

Mode

+

_

Tem p/Tim e

Auto

Power Saver

Mid

High

Low

Tim er

Fa n Speed

A06529

Fig. 2

---

Air Conditioner Parts Description

NOTE

: The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the

air conditioner you have selected.

 


background image

4

ELECTRICAL SPECIFICATIONS

1. All wiring must comply with local and national electrical

codes and must be installed by a licenced electrician. If you
have any questions regarding the following instructions,

contact a licenced electrician.

2. Check available power supply and resolve any wiring

problems BEFORE installing and operating this unit.

3. For your safety and protection, this unit is grounded

through the power cord when plugged into a matching wall

outlet. If you are not sure whether your wall outlet is
properly grounded, please consult a licenced electrician.

4. The wall outlet (3--pin) must match the plug (3--pin) on the

power cord supplied with the unit. DO NOT use plug

adapters or extension cords. See (Table 1) for receptacle and
fuse information.

5. The rating plate on the unit contains electrical and other

technical data. The rating plate is located on the right side of
the unit. Make sure to use the correct power supply

according to the rating plate of your air conditioner.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death and/or property damage.
Shut off electrical power to unit before installing or

servicing.
If the air conditioner has a serial plate rating of 115 volts
and up to and including 7.5 amps, the unit maybe on a fuse

or circuit breaker with other devices. However, the
maximum amps on all devices for that fuse or circuit

breaker can not exceed the amps of the fuse for the circuit
breaker.
If the air conditioner has a serial plate rating of 115 volts

and greater than 7.5 amps it must have its own fuse or
circuit breaker, and no other device or unit should be

operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating of 230 volts, it

must have its own fuse or circuit breaker, and no other

device or unit should be operated on the fuse or circuit
breaker.

!

WARNING

RECEPTACLE AND FUSE TYPES

COOLING CAPACITY

10K---14K

(Cooling only)

18K(Cooling only)

10K---12K(With heating)

23K

(Cooling only)

18K---23K

(With heating)

RATED VOLTS

125

250

250

250

AMPS

15

15

20

30

WALL OUTLET

FUSE SIZE

15

15

20

30

NOTE

: 10K--14K (Cooling only) including models

18K (Cooling only) including models
10K--12K (with Heating) including models

23K (Cooling only) including models
18K--23K (with Heating) including models

NOTE

:

Check rating plate on your specific model for exact receptacle and fuse type.

 


background image

5

TIPS BEFORE INSTALLATION

UNIT OPERATION HAZARD

Failure to follow this caution may result in damage to unit

components.
To avoid installation/operating difficulties, read the

instructions thoroughly.

CAUTION

!

Your Room Air Conditioner unit is designed to be highly efficient

and save energy. Follow these recommendations for greater
efficiency.

1. Select thermostat setting that suits your comfort needs and

leave the thermostat at that chosen setting.

2. The air filter is very efficient in removing airborne particles.

Keep the air filter clean. Typically, the filter should be

cleaned once a month. More frequent cleaning may be
necessary depending on outdoor and indoor air quality.

3. Use drapes, curtains, or shades to keep direct sunlight from

heating your room, but DO NOT obstruct the air
conditioner. Allow air to circulate around the unit without

obstructions.

4. Start your air conditioner before outdoor air becomes

hot/cold and uncomfortable. This avoids an initial period of
discomfort while the unit is cooling or heating off the room.

5. When outdoor temperature is cool enough, use HIGH or

LOW FAN only. This circulates indoor air, providing some
cooling comfort, and utilizes less electricity than when

operating on a cooling setting.

Your Room Air Conditioner was designed for easy installation in a

single or double--hung window.

NOTE

: This unit is NOT designed for vertical (slider type)

windows.

POWER SUPPLY CORD

This room air conditioner is equipped with a protective power
supply cord that senses current leakage (see Fig. 3). Unit power is

automatically disconnected when unsafe conditions are detected.
To test the power supply cord:

1. Plug power supply cord into a grounded 3--prong outlet
2. Press RESET.
3. Press TEST (listen for click; RESET button will trip and

pop out).

4. Press and release RESET (listen for click; RESET button

will latch and remain in). The power supply cord is ready

for operation.

The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if the RESET button fails
to trip when the test button is pressed or fails to reset. A damaged

power supply cord must be replaced with a new power supply cord
obtained from the product manufacturer. The damaged cord MUST

NOT be repaired.
Do not use the power supply cord as an off/on switch. The power
supply cord is designed as a protective device.
The power supply cord contains no serviceable parts. Opening the
tamper--resistant case voids all warranty and performance claims.

TEST

RESET

A06531

Fig. 3

---

Power Supply Cord

NOTE

: Save the shipping carton and packing materials for future

storage or transport of the unit. Please check the contents of the
hardware kit against the corresponding model check list, prior to
installation of the unit. See lists below in Fig. 4.

3/4”Screws (10)

Top Channel(1)

End Cap &

Leveling Legs(2)

Bottom Channel(1)

(F

or 10K to 12K models

)

Lock Washers(4)

1/4” Nuts(4)

Mounting

Brackets(2)

Angle

Brackets(2)

1---1/2”x1/4 Bolts(4)

Side Curtain RH(1)
Side Curtain LH(1)

Shutter Clamp(2)

3/4”Screws (10)

1/4”Screws (23)

Top Channel(1)

Seal(1)

Lock Washers(4)

1/4” Nuts(4)

Mounting

Brackets(2)

Angle

Brackets(2)

1---1/2”x1/4 Bolts(4)

Side Curtain RH(1)
Side Curtain LH(1)

Shutter Clamp(2)

Washer(10)

Foam (1)

Double

Adhering

Seal(1)

Bottom Channel(1)

(For 14K to 23K models)

---Factory Installed)

A06532

Fig. 4

---

Installation Hardware

NOTE

: Surplus screw(s) for spare use.

Tools needed for window installation

S

Screw drivers: both Phillips and flat head

S

Power drill: 1/8 inch diameter drill bit

S

Pencil

S

Measuring tape

S

Scissors

S

Carpenters level

 


background image

6

INSTALLATION INSTRUCTIONS

PERSONAL INJURY/UNIT OPERATION HAZARD

Failure to follow this caution may result in personal injury

and/or damage to unit components.
It is recommended to have someone assist you during the

installation of this unit because the compressor is located on

the controls side of the unit (right side) and this side will be

heavier and more awkward to manipulate.

CAUTION

!

Step 1

Select the Best Location

A. Your room air conditioner was designed to fit easily into a

single or double hung window. However, since window
designs vary, it may be necessary to make some modifications

for safe and proper installation.

B. Make sure window and frame is structurally sound and free

from dry and rotted wood.

C. For maximum efficiency, install the air conditioner on side of

the house or building which favors more shade than sunlight.
If the unit is in direct sunlight, it is advisable to provide an
awning over the unit.

D. Provide sufficient clearance around the cabinet to allow for

ample air circulation through the unit (see Fig. 5). The rear of

the unit should be outdoors and not in a garage nor inside of a
building. Keep unit as far away as possible from obstacles and
obstructions and at least 30” above the floor or ground.

Curtains and other objects within a room should be prevented
from blocking the air flow.

E. Be certain the proper electrical outlet is within reach of the

installation. Use only a single outlet circuit rated at proper
current (see table 1 on page 4). All wiring should be in

accordance with local and national electrical codes.

F. Your unit was designed to evaporate condensation under

normal conditions. However, under extreme humidity
conditions, excess condensation may cause the basepan to

overflow to the outside. The unit should be installed where
condensation run--off cannot drip on pedestrians or
neighboring properties.

Awning

Side

obstruction

Ground

Fence,

wall, or

other

obstacle.

12” Min.

30” Min.

20”

Min.

20”

Min.

A06534

Fig. 5

---

Air Conditioner Clearances

Window Opening Requirements

SIZE

MODEL

12K

14K---23K

Cabinet Size

(W/H/D)

22.8”/15.7”/24.1”

26.5”/18.5”/26.9”

Window Opening

Width

27” --- 41”

30” --- 44”

Window Opening

Height

16”

18.5”

Step 2

Preparation to Remove the Air Conditioner

Slide--Out Chassis

A. Remove total of (4) Philips screws securing the chassis to the

cabinet. There are (2) screws on each side. The set of screws
closest to the front of the unit secure the front panel to the
cabinet. The set of screw closest to the rear of the unit secure

the cabinet to the chassis (see Fig. 6).

B. Remove the front panel assembly from the cabinet by gently

pulling it.

C. Grasp the pull handle at the front of the slide--out chassis and

carefully slide the air conditioner out of the cabinet (see Fig. 7).
NOTE: Screws must be reinstalled upon completion of the
window installation to secure slide--out chassis.

IMPORTANT

: Please seek assistance for this procedure.

A06535

Fig. 6

---

Screw Removal

Coil

Pull Handle

Chassis

A06536

Fig. 7

---

Air Conditioner Removal

Step 3

Assembly of the upper & lower channels to the

cabinet

A. ” L” Shaped Top Channel: Stick the double adhering seal to

the ” L” shaped top channel, and then Install the ”L” shaped

top channel to the cabinet as shown in Fig. 8 using (5) 1/4”
screws.

B. ”n” Shaped Bottom Channel installed as shown in Fig.8 using

(4) 1/4” screws.

 


background image

7

NOTE

: For 14K to 23K models, the bottom channel has been

factory--installed, and their shapes may differ from the others, but
their functions are similar.

Step 4

Assembly of the side shutters (curtains) to the cabinet.

A. Slide the shutters into the top and bottom channels as shown in

Fig. 9. The shutters are identified (on each frame) as ”left” &

”right”. Attach the shutters to the cabinet using (4) 1/4” screws
on each side.

For 10K to 12K models 

Channel

1/4" Screw

Double 
Adhering seal

 For 14K to 23K models,
   ( Factory-Installed)

A06537

Fig. 8

---

Channel Assembly

Shutter Frame

Right Shutter

1/4" screw

A06538

Fig. 9

---

Shutter Assembly

Step 5

Installation of Mounting Brackets and First Sealing

Strip
NOTE

: Windows come in a variety of different styles. Therefore,

it may be necessary to modify or improve your particular
installation.

A. Attach the bracket assembly to 90 angle support brackets (Fig.

10) using (2) 1 1/2” bolts, two bolts per bracket. Secure with

the (2) 1/4” lock washers and (2) 1/4”nuts. DO NOT
immediately tighten these bolts as it may be necessary to adjust

the depth of the bracket assembly, depending on the depth of
your window sill. See (Fig. 12).Install the two leveling screws
into the 90 support brackets. Test the bracket assembly in the

window before cabinet installation. If the leveling screws are
distanced too far away from the wall to provide stability, it may

be necessary for you to fill this area with a solid piece of wood.
See (Fig. 13).

B. Measure the inside window sill width and find the center as

shown in (Fig. 11). Align the V--slot in each bracket on these
marks and mount the brackets to the sill using 3/4” screws

provided. Brackets should be perpendicular to the inside
window sill. See (Fig. 11).

Bracket Assembly

Bracket Bolts

Leveling Screw

V-slot

90  Angle

Support Brackets

(TOP VIEW)

A06539

Fig. 10

---

Bracket Assembly

Center

Window sill

V-slot

Measurement for Model 10K =9.6" 

9.6"

9.6"

Measurement for Model 12K = 10.3" 

10.3"

10.3"

12.6"

12.6"

Measurement for Model 14K to 23K = 12.6"

A06540

Fig. 11

---

Bracket Mounting

C. For proper condensation run--off it will be necessary to adjust

the angle/pitch of the window brackets. This is accomplished
by adjusting the distance of the leveling screw on the outer

wall. The maximum angle/pitch should not exceed more than
3/16”. See (Fig.12).

D. Cut the seal strip to fit the underside of the bottom window

sash. Remove the peel--off backing on the seal and attach it to
this sash. See (Fig. 14).

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
Use a solid piece of wood to provide stability. This will be

required when sills are extra deep (see Fig. 13).

CAUTION

!

(2) 3/4" screws per bracket

Bracket Assembly

Leveling Screw

Outer Wall Construction

3/16" Maximum

A06541

Fig. 12

---

Depth/Angle Illustration

 


background image

8

Solid Piece Wood
(If required)

A06542

Fig. 13

---

Solid Piece of Wood Placement

Window Sash

Window Sash
Sealing Strip

A06543

Fig. 14

---

Seal Strip Adhesion

Step 6

Installation of the cabinet

A. Align one hole in the bottom of the cabinet with one hole in

the bracket assembly. Secure the cabinet to the bracket using

(3) 1/4” screws provided. Repeat the same procedure on the
opposite side of the cabinet. See (Fig. 15).

B. Ensure the ”L” shaped mounting channel is positioned in front

of the sash. The bottom channel of the cabinet should be
positioned in the track provided on the bracket assembly. Pull

the window down until it rests just behind the front of the ”L”
shaped mounting channel. See (Fig. 16).

C. Check to make sure that the cabinet is slanted slightly

downward on the outside. If necessary, re--adjust support
bracket as shown in (Fig. 12).

Step 7

Secure Shutters

A. Carefully slide the air conditioner back into the cabinet.

(Please seek assistance for this procedure).

B. Reinstall the slide--out--chassis security screws (removed

earlier) on both sides of the cabinet (see Fig. 12). Secure the

top of the frames to the window sash with (2) 3/4” screws.

C. Now, secure bottom frame of shutters using one shutter clamp

and one 3/4” screw on each side (see Fig. 12).

Step 8

Reinstalling Front Panel Assembly

A. Position the front panel on the cabinet starting at the top. The

front panel lock tabs must be inserted into the retaining slots in
the cabinet. Repeat this procedure on all sides.

B. Secure the front grille to the cabinet using the Philips screws

removed earlier (see Fig. 6).

Step 9

Complete the installation

A. Cut the foam to fit the opening between the top of the inside

and outside window (see Fig. 18).

B.

Some installations may require additional sealing around

the window and air conditioner

. Check for any air leaks and

seal where necessary.

C. In very humid areas, the water removal may be excessive

enough to overflow the unit or increase the noise of the air

conditioner. If this occurs, you may wish to attach a drain hose
(not included) to the drain plug allowing condensations to run
off conveniently (see Fig. 19).

NOTE

:

Fresh Air ventilation is usually kept in the closed

position. Use only when clearing smoke and/or odors from the
room. Pull to open (see Fig. 20).

1/4" Screws

A06544

Fig. 15

---

Secure the Cabinet

Window Sash

"L"Shaped
Mounting
Channel

Seal

A06545

Fig. 16

---

Mounting Channel

Coil

3/4" screws

Security Screw

"L"Shaped
Mounting
Channel

Seal

F

HR

FAN
SPEED

MODE

OFF

ON

/

TIMER

Airc ond itioner

WAIT THREE MINUTES
BEFORE RESTARTING

A06546

Fig. 17

---

Security Screw Detail

 Foam

A06547

Fig. 18

---

Foam Fitting

 


background image

9

Drain Hose
(not included)

A06548

Fig. 19

---

Drain Hose

OUTDOOR AIR VENT LEVER

A06533

Fig. 20

---

Outdoor Air Vent Lever

STORM WINDOW APPLICATIONS

If the window is blocked by a storm window and the storm
window cannot be removed, a mounting board (field provided)

will need to be added to the window sash. The air conditioner
needs to be pitched downward to the back in order for condensate

to drain properly.
The frame of the storm window (or any other obstruction) must be
at least 1/2“. lower than the window sill. If the storm window

frame is not at least 1/2“. below the window sill, then a mounting
board will need to be added to raise the height of the window sill

(see Fig. 21). The board will need to be provided and cut by the
installer.

1. The wood mounting board should be a minimum of 1--1/2”

wide and should run the length of the window. The

thickness of the mounting board is dependent on the height
of the storm window frame. The mounting board should

raise the front of the air conditioner high enough so that the
unit will be pitched downward at least 5/8” when the back

of the unit is resting on the storm window frame. See Fig.
21.

2. Cut the wood mounting board to fit the window.
3. Install the wood mounting board on the window using 2

field--provided nails or screws.

4. Drain holes or slots in storm window frame must not be

caulked or painted shut. Holes are needed to drain rain
water and condensate. Ensure that trapped water can drain

out.

Fig. 21

---

Storm Window Applications

 


background image

10

WALL INSTALLATION

To install the room air conditioner in the wall, perform the

following procedure:

1. Remove air conditioner from shipping box. Do not install

window installation parts.

2. Determine the location for air conditioner. Make sure there

is adequate clearance on the inside and outside of the wall.
Ensure that the power cord will reach the available socket
without an extension cord. Air conditioner can be installed

in walls up to 7” thick. Side louvers must never be blocked.
Select a wall surface that:

S

Does not support major structural loads such as the frame
construction at ends of windows and under truss--bearing

points

S

Does not have plumbing or wiring routed inside

S

Is near existing electrical outlets or near where a new outlet
can be installed

S

Faces the area to be cooled and is not blocked by
obstructions

S

Allows unblocked airflow from rear (outside) of installed
air conditioner

3. The following parts will need to be provided by the

installer:

S

wood frame

S

wood shims

S

wood screws (no. 10, 1” long)

4. Working from the inside of the room, find a wall stud

nearest the center of the area where the air conditioner will
be installed. This can be determined by sounding walls or

using a stud finder.

5. Cut or knock out a hole on each side of the center stud. (See

Fig. 22.)

IMPORTANT

: Read entire instructions before cutting hole in

wall.

6. Measure between the inside edges of every other stud as

shown in Fig. 22

7. Follow all local building codes when building and installing

frame. Build a wooden frame that will be placed around the

unit in the wall. The frame will reinforce the hole in the wall
where the air conditioner is installed and is used to secure
the air conditioner to the wall. The depth of the frame

should approximately match the depth of the wall. The
thickness of the frame will need to be added to the

dimensions to determine the size of the hole in the wall.

IMPORTANT

: Be sure to measure air conditioner to check size

before constructing frame.
For example, if using 3/4” thick wood for the frame, the hole
would need to be: 20--1/2” + 3/4” + 3/4” = 22” wide.

IMPORTANT

: If thickness of the wall covers top and side vents

of the air conditioner when it is installed, the outer portion of the
wall opening must be widened. The top and side vents must be
clear and uncovered.

8. After the frame has been constructed, check to make sure

that the air conditioner fits correctly inside it. If the frame is

too tight or too loose, adjust the size or re--construct.

9. Measure the outer dimensions of the frame and use those

dimensions to cut the hole in the wall. Make sure the hole is
level or condensate will not drain properly.

10. Install wooden frame into hole in wall. Make sure frame is

properly secured. Fill in the space between the frame and
the studs with wood shims (spacers). Nails spacers to studs.

If required, provide studs around entire frame to reinforce
stability of wall (see Fig. 24).

A06739

Fig. 22

---

Wall Installation Location

UNIT

Dimensions

A

B

CA 

1

516, 1826, 2326

18.25

26.4

A06740

Fig. 23

---

Frame Construction

A06741

Fig. 24

---

Frame Installation

 


background image

11

11. Caulk joints in wood frame as required. If wall thickness is

7” or more, add aluminum flashing over bottom of frame

opening to ensure no water can enter area between inner and
outer wall.

12. Remove the chassis from the unit cabinet.

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.
Be careful when handling chassis. Sharp edges on coil fins

can cause personal injury.

CAUTION

!

13. Slide the empty cabinet into the wall opening and into

wooden frame. Approximately 2--1/2“ of the cabinet should
be in the room. The rest of the cabinet should be positioned

through and outside the wall. (See Fig. 25.) Maintain proper
slope for condensate drain operation. Bottom rail should be

resting firmly on bottom board of wooden frame.

14. Secure bottom rail to wood frame with two large wood

screws (1” long) using the two holes in the bottom of the

channel. (See Fig. 26.)

15. There are screw holes in the cabinet (4 each side, 4 top)

which are used to secure the cabinet to the wooden frame.
With the cabinet in its final position, drill holes in the
wooden frame using the screw holes in the cabinet as a

guide. After the holes have been drilled, secure the cabinet
to the wooden frame using field--supplied screws. See Fig.

27.

16. Caulk around wood frame and wall opening on outside wall

for a water--tight seal.

17. Optional caulking between the cabinet and the wooden

frame may be done on inside wall. Caulking provides an air

seal around the cabinet. Decorative wood trim may be
added to provide a more pleasing appearance.

18. Lift chassis and carefully slide it into the cabinet. Be sure

that it is firmly seated towards the rear of the cabinet.

PERSONAL INJURY/UNIT OPERATION HAZARD

Failure to follow this caution may result in personal injury

and/or damage to unit.
Do not push on the controls or the coil when installing

chassis. Personal injury and/or unit damage could result.

CAUTION

!

19. Install the front panel
20. Plug in the unit.

A06742

Fig. 25

---

Cabinet Location in Wall

A06743

Fig. 26

---

Securing Bottom Rail of Cabinet

A06744

Fig. 27

---

Securing Cabinet to Frame

MASONRY CONSTRUCTION

The air conditioner is installed the same way as the Wall

Installation section with a few exceptions. Follow all local and
national building codes.
The cabinet can be secured to the masonry by using masonry nail

or masonry anchor screws.
Another installation technique would be to construct a frame of

2 x 4s and install the frame between the wall opening and the
cabinet. The frame must be securely anchored to the masonry wall

opening.
Use a lintel to support masonry above wall opening. Install exterior
cabinet support brackets.

 


background image

12

OPERATING INSTRUCTIONS

Electronic Control Panel Model

You can easily operate this air conditioner by pressing relevant

button on the control panel as well as the remote control

|

Button

The air conditioner will be started when it is energized or will be
stopped when it is in operation, if you press this button. When the

air conditioner is heating, allow 3 minutes after you press this
button.

Mode Button

Each time MODE button is pressed, the operation mode is changed

in sequence:
COOL: COOLING -- FAN ONLY -- ENERGY SAVING --

COOLING

HEAT: COOLING -- FAN ONLY -- HEATING --

ENERGY SAVING -- COOLING

NOTE

: After setting the mode, allow 3 minutes before switching

to another mode.
In the FAN ONLY Mode, room temperature display range is from
0

_

C (32

_

F) to 38

_

C (99

_

F).

Room temperature below 32

_

F, the temperature display L0.

Room temperature above 99

_

F, the temperature display H1.

Fan Speed Button

Used to select fan speed in sequence auto, low, medium, and high.

Timer Button

Used to set or cancel timer operation.
When the unit is in operation, you can set OFF TIMER.
When the unit is off, you can set ON TIMER.

Timer setting range is 0 to 24 hours.
If the OFF TIMER is set, the timer LED displays the remaining
time to turn off the unit for only 12 seconds, then LED shifts to

display set temperature. If you press TiMER button within the 12
seconds, OFF TIMER will be canceled.
If the ON TIMER is set, the timer LED displays the remaining time

to turn on the unit. If you want to cancel ON TIMER, press
TIMER button.

Button

Used to set room temperature in COOLING mode or used to set

time in TIMER mode. If the two keys are pressed at the same time,
the temperature LED display will alternate between

_

C and

_

F.

NOTE

:

Temperature setting range is from 19

_

C (66

_

F) to

31

_

C (88

_

F).

F

Indication symbols of LED on control panel:

High fan speed

Medium fan speed 

Low fan speed

Auto fan speed

Cooling

Fan only

Display set temp
Display set timer

Timer

 Above LED lights on when the relevant mode is in used. 

Energy-saving

Heating

  
h

  Fa n
Spe e d

Mode

Tim e r

Airc onditione r

Fig. 28

---

Control Panel

 


background image

13

Remote Control

Power

Mode

+

_

Temp/Time

Auto

Power Save r

Mid

High

Low

Timer

Fan Spee d

1

1

2

3

8

2

3

5

6

8

            

 

 BUTTONS

          Power BUTTON

Mode BUTTON

Timer BUTTON

The appliance will be started when it is
energized or will be stopped when it is  
in operation, if you press this button.

Used to select the operation mode.

Used to set or cancel timer operation.

4

High BUTTON

Used to select the 

 mode.

high fan speed 

5

Mid   BUTTON

Used to select the Mid 

 mode.

fan speed 

6

Low  BUTTON

Used to select the Low 

mode.

fan speed 

7

Auto BUTTON

Used to select the Auto

 mode.

 fan speed 

9

Power Saver BUTTON

Used to select the 

mode.

Energy-saving 

4

7

9

Used  to  set room  temperature  in Cooling
mode  or used to set   time  in Timer  mode.

  

Fig. 29

---

Remote Control

How to Insert Batteries
Step 1

Remove battery cover according to arrow direction.

Step 2

Insert new batteries making sure that the (+) and (--)

of battery are matched correctly.
Step 3

Reattach the cover by sliding it back into position.

NOTE

:

-- Use 2 LR06 AA (1.5 volt) batteries. Do not use rechargeable
batteries. Replace batteries with new ones of the same type when
the display becomes dim.
-- If the replacement is done within 1 minute, the remote control
will keep original presetting. (This function only for LCD remote
control).

How to Use

To operate the room air conditioner, aim the remote control to the

signal receptor. The remote control will operate the air conditioner
at a distance of up to 23 ft. when pointing at signal receptor of unit.

F

HR

  FAN
SPEED

MODE

OFF

ON

/

TIMER

Airconditioner

WAIT THREE MINUTES 

BEFORE RESTARTING

Signal receptor

 


background image

14

CARE AND MAINTENANCE

When servicing the air conditioner, be sure to turn the mode switch
to the “OFF” position and disconnect the power cord from the

electrical outlet.

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.

DO NOT

use gasoline, benzine, thinner or other chemicals

on the air conditioner as these substances may cause

damage to the paint finish and deformation of plastic parts.

CAUTION

!

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
Never attempt to pour water directly in front of the unit as

this will cause deterioration of the electrical insulation.

CAUTION

!

If the air filter becomes clogged with dust, air--flow is obstructed
and reduces efficiency. The air filter should be cleaned once a

month. More frequent cleaning may be necessary depending on

outdoor and indoor air quality.

Air Filter Removal

The air filter is located behind the air intake front grill.
To remove the air filter, open the air inlet grille and take out the air

filter.
To reinstall the air filter, reverse the above procedure.

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage

and/or improper operation.
DO NOT forget to install the air filter. If the air conditioner

is left to operate without the air filter, dust is not removed

from the room and may cause your air conditioner to fail.
When the air filter inlet grille and cabinet are dirty, wipe

with lukewarm water (below 40

_

C/104

_

F). Use of mild

detergent is recommended

CAUTION

!

Cleaning the Air Filter

1. Remove dust clogged in the filter by tapping it or

vacuuming clean it.

2. Wash the filter well with lukewarm water below 40

_

C

(104

_

F) while rubbing lightly: To get better results, wash it

with soapy water or a neutral cleaning agent.

3. Rinse the filter well using clean water then dry completely.

End--of--Season Care

1. Operate the fan alone for half a day to dry out the inside of

the unit.

2. Turn off power and remove plug from all socket.
3. Clean filter.
4. Store in a dry location.

TROUBLESHOOTING GUIDE

Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution.

PROBLEM

POSSIBLE CAUSE

SUGGESTED SOLUTION

Air conditioner will not operate

No power to the unit.

Check connection of power cord to power source. Check

fuse or circuit breaker. Set FAN CONTROL to position other

than ”OFF”.

Inefficient or no cooling

Dirty air filter. Inappropriate capacity for

application. Blocked air flow. Power

interruption, settings change too quick-

ly, or compressor overload tripped.

Clean or replace air filter. Check with dealer to determine

proper unit capacity for application. Remove obstruction

from grill or outdoor louvers. Let fan run to restart compres-

sor (in approximately 10 minutes).

Noisy unit

Loose parts. Inadequate support.

Tighten loose parts. Provide additional support to unit.

Odors

Formation of mold, mildew, or algae on

wet surfaces.

Drain plug and drain base pan. Replace drain plug. Clean

unit thoroughly. Remove

Water dripping outside

Condensation run---off is normal dur-

ing hot and humid weather

Add flexible tubing to redirect water flow.

Water dripping inside

Unit is not properly angled to allow wa-

ter to drain outside.

Unit must be installed on an angle for proper condensa-

tion run---off. Check the unit and make adjustments.

Ice or frost build---up

Low outside temperature. Unit air filter

is dirty.

When outdoor temperature is approximately 65 F or be-

low, frost may form when unit is in cooling mode. Switch

unit to FAN (only) operation until frost melts. Remove and

clean filter.

NOTE

: If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a licensed technician.

 


background image

International Comfort Products, LLC 

Room Air Conditioner Limited Warranty

Subject to the conditions and exclusions listed below International Comfort Products LLC (hereinafter referred 

to as “ ICP”) warrants this product against failures due to defects in materials and workmanship.

TWO YEAR WARRANTY

  - ICP warrants to the initial purchaser of this product against failures due to  

defects in materials or workmanship under normal use and maintenance for a period of two years from the 

date of original purchase. ICP, through its authorized independent servicing dealers or distributors, will either 

repair or replace a defective product (as decided solely by ICP) free of charge to the user. ICP may replace 

any defective part with either a new or remanufactured part, at ICP’s sole option.

THIS LIMITED WARRANTY DOES NOT INCLUDE

 costs incurred for diagnosing, removing, installing, 

shipping or transporting the product or any parts. User is responsible for these costs

LIMITATION OF WARRANTIES

 — ALL IMPLIED WARRANTIES AND CONDITIONS  (INCLUDING IMPLIED 

WARRANTIES AND CONDTIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) 

ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE APPLICABLE PRODUCT 

COMPONENT IS EXPRESSLY WARRANTED HEREIN. Some states or provinces do not allow limitations on 

how long an implied warranty lasts, so the above limitation may not apply to you. THE EXPRESS WARRANTIES 

MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED OR CHANGED BY 

ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ICP WILL NOT BE RESPONSIBLE FOR 

ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES OF ANY 

NATURE WHATSOEVER. Some states or provinces do not allow the exclusion of incidental or consequential 

damages, so the above limitation may not apply to you. All work provided for by this warranty shall be 

performed during normal working hours. All replacement parts, whether new or remanufactured, assume as their 

warranty period only the remaining time period for which the replaced  component is expressly warranted herein.

ICP WILL NOT BE RESPONSIBLE FOR:

1. Damage or failure due to failure to perform normal maintenance outlined in the Owner’s Guide.

2. Instruction on methods of control and use of air conditioning unit after initial installation.

3. Damage or repairs needed as a consequence of faulty installation or application. This is the responsibility of 

    the installer.

4. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or any other damages due to 

    the inadequacy or interruption of electrical service.

5. Damage or repairs needed as a consequence of any misapplication, abuse, unauthorized alteration, improper 

    servicing or operation.

6. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments, or other conditions 

    beyond the control of ICP.

7. Any parts not supplied or designated by ICP.

8. ICP products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.

9. Shipping damage or damage as a result of storing or transporting the unit.

This warranty gives you specific rights, and you may also have other rights which vary from state to state or 

province to province.

IF YOUR UNIT DOES NOT WORK, FOLLOW THESE STEPS IN ORDER:

1. Check the things you can do yourself. These include being sure the air conditioner is plugged in an 

    appropriate receptacle, checking the fuse or circuit breaker and ensuring its replacement or resetting, if 

    necessary, and rereading the instruction book to ensure all controls are set properly. By doing this you can 

    save money. Many unnecessary calls result in the serviceman doing what the owner can do for himself.

2. CONTACT YOUR DEALER.

 You may find this name printed on the product, on your invoice, or in your 

    Homeowner’s Packet.

3. CONTACT ICP IF A SATISFACTORY SOLUTION IS NOT REACHED IN STEP 2.

    International Comfort Products LLC, 650 Heil Quaker Blvd, P.O Box 128, Lewisburg Tennessee, USA, 37091

    Telephone (931) 270-4110

FOR FUTURE REFERENCE, FILL IN DETAILS OF YOUR PURCHASE. KEEP YOUR SALES RECEIPT.

Model/Catalog No. _____________________   Installed By: ______________________________________________

Service/Discrete No. ____________________   Name of Owner ___________________________________________

Unit Serial No. _________________________   Address of Installation _____________________________________

Date of Installation _____________________  _________________________________________________________