Full Text Searchable PDF User Manual

Model 458-LM-E1-36-TP100
Rev.-
Date of Publication:02/25/2019
“Results You Can Count On”

Customer Support
Thank you for your purchase of the Telebyte Model 458-LM-E1-36-TP100 Multi-Standard
Local Loop Simulator. This one-channel product simulates TP100 as specified in ETSI TS 101
270-1 and G.992.5 Annex M.
Contact Information:
Telephone
E-mail/Internet
General:
631-423-3232
support@telebytebroadband.com
Technical support: 800-835-3298
sales@telebytebroadband.com
Fax:
631-385-8184
www.telebytebroadband.com
Telebyte, Inc.
355 Marcus Blvd
Hauppauge, NY 11788

Customer Care
Warranty
One-year Warranty
•
Telebyte will furnish parts and labor for the repair or replacement of products found by Telebyte to be defective
in material or workmanship during the warranty period.1
Extended Customer Care
Refer to the Customer Care section of the Telebyte web site for the most current information on extended
warranty and calibration contracts
2,3,4:
http://www.telebytebroadband.com/customercare.html
Disclaimer of Warranties and Other Terms and Conditions
1
TELEBYTE, INC. warrants its broadband simulation equipment to be free from defects in material and workmanship, under normal and proper use
and in its unmodified condition, for 12-
months, starting on the date it is delivered for use. TELEBYTE’S sole obligation under this warranty shall be to
furnish parts and labor for the repair or replacement of products found by TELEBYTE to be defective in material or workmanship during the warranty
period. Warranty repairs will be performed at the point of manufacture. Equipment approved for return for warranty service shall be returned F.O.B.
TELEBYTE factory and will be redelivered by TELEBYTE freight prepaid, except for non-continental U.S.A. locations. These deliveries will be sent
COD freight and import/export charges.
2
The customer is responsible for freight and customs charges when shipping products to and from Telebyte for calibration services.
3
You must purchase the extended warranty at the time of purchase or during the initial warranty period.
4
You must purchase the calibration contract at the time of purchase or during the initial warranty period. The above warranty is in lieu of all other
warranties, expressed or implied, statutory or otherwise, including any implied warranty of merchantability or fitness for a particular purpose.
TELEBYTE shall not be liable for any damages sustained by reseller or any other party arising from or relating to any equipment failure, including but
not limited to consequential damages, nor shall TELEBYTE have any liability for delays in replacement or repair of equipment.

Equipment Returns
Out of warranty equipment may be returned, prepaid, to the Hauppauge, N.Y.
customer service facility. Return shipping charges will be billed to the customer.
The repaired unit will have a 90-day warranty. In those cases where "no trouble"
is found, a reduced charge will be billed to cover handling, testing, and
packaging. Whether in or out of warranty, a Return Material Authorization
number
(RMA)
is
required
and
may
be
obtained
by
going
to
www.telebytebroadband.com and opening a technical support case.
Please be sure to reference the RMA number on the outside container.

Table of Contents
1.0 Introduction .................................................................................................................................. 1-1
2.0 Specifications ............................................................................................................................... 2-1
2.1 458-LM-E1-30-TP100 .................................................................................................................. 2-1
2.2 458-3SLB ..................................................................................................................................... 2-1
2.3 458-CC-16/458-CM ...................................................................................................................... 2-2
3.0 Control .......................................................................................................................................... 3-1
3.1 Remote Commands ...................................................................................................................... 3-1
3.1.1 RS-232 (Serial Port) Remote Commands ................................................................................. 3-1
3.2 Graphical User Interface ............................................................................................................ 3-2
3.3 LCD Display/Front Panel ........................................................................................................... 3-3

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator w/Optional AWGN Generator
Page 1-1
1.0 Introduction
The Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator is the ideal solution for ADSL,
ADSL2, ADSL2+, and VDSL2 (including Profile 35b) chip/modem/DSLAM testing out to 9,000 m in
very small increments.
This powerful local loop simulator is plugged into our Model 458-3SLB (3-Slot) or 458-CC-16 (16
Slot) chassis where settings are controlled by a convenient keypad located on the front, RS-232,
Ethernet or IEEE-
488(GPIB). The modular design of Telebyte’s products allows the 458-LM-E1-36-
TP100 to be combined with other line modules for a wide variety of test configurations.

Model 458-LM-E1-36-TP100
Page 2-1
2.0 Specifications
2.1 458-LM-E1-36-TP100
Product Specifications
Simulation
•
Accurately simulates attenuation and impedance
•
Full bidirectional operation at all specified frequencies
•
TP100 as specified in ETSI TS 101 270-1 & G.992.5 Annex M
Bandwidth
DC to 36 MHz
Attenuation Accuracy
TR-114 Issue 3 TP100 test loops (150m, 300m, 450m, 600m, 900m, 1050m,
1200m, 1500m, 2000m, 2500m, 3000m)
MAE < 0.5dB
All other loop lengths TP100: Typically, MAE < 1 dB 20 kHz to 36 MHz
(when source and load impedances are 100 ohms)
Maximum Attenuation
> 90 dB
Impedance Accuracy
Typically, +/- 10%
Maximum Voltage Tip Ring
200 V
Maximum Current
130 mA
Connectors
2 RJ-
45’s on front
2.2 458-3SLB
458-3SLB Product Specifications (3-Slot Chassis and Control Module)
Controls
Keypad for setting loop lengths and IEEE-488 address, RS-232, or Ethernet
communication parameters.
Indicators
Backlit LCD display of line length and set up parameters.
Power
88 to 264 VAC, 50 or 60 Hz
Size
[2U] 19 in W x 22 in D x 3.47 in H (482.6 mm W x 558.8 mm D x 88.1 mm H)
Environmental
Operating: +32 F to +122 F (0 to +50 degrees C)
Storage: 0 to 95% relative humidity (non-condensing)
Remote Control Connectors
RS-232: DB9 female (DCE); GPIB:IEEE488 24-pin connector. Ethernet: RJ-45
Plug-In Compatibility
Accepts 1-3 458 plug-in modules

Model 458-LM-E1-36-TP100
Page 2-2
2.3 458-CC-16/458-CM
Product Specifications 458-CC-16 (16-Slot Chassis) & 458-CM (sold separately)
Controls
Keypad for setting loop lengths and IEEE-488 address, RS-232, or Ethernet
communication parameters.
Indicators
Backlit LCD display of line length and set up parameters.
Power
100 - 240 VAC, 50 or 60 Hz
Size
[7U] 19 in W x 22 in D x 12.22 in H
(482.6 mm W x 558.8 mm D x 310.4 mm H)
Environmental
Operating: +32 F to +122 F (0 to +50 degrees C)
Storage: 0 to 95% relative humidity (non-condensing)
Remote Control Connectors
RS-232: DB9 female (DCE); GPIB:IEEE488 24-pin connector. Ethernet: RJ-45
Plug-In Compatibility
Accepts 1-16 458 Line Modules
Specifications are subject to change without notice. Made in USA.
➢
Detailed information about the operation of the 458-3SLB and 458-CC-16/458-CM can be
found in the reference manuals for those products. Only information specific to the 458-LM-
E1-36-TP100 is provided in this manual.

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator
Page 3 -1
3.0 Control
The Model 458-LM-E1-36-TP100 can be controlled three ways: via RS-232 and IEEE488 Remote
Commands, our 458 Universal Graphical User Interface or the LCD display and buttons on the front
panel of our 458-3SLB or 458-CM.
3.1 Remote Commands
Please refer to the manuals for the 458-3SLB or 458-CC-16/458-CM for remote commands common
to many line modules, including the 458-LM-E1-36-TP100. This manual contains commands unique
to this module.
3.1.1 RS-232 (Serial Port) Remote Commands
Set Length Command Values: SL:M:LE,C
Where,
SL = set length
M = module (slot) number 01 16 (458-CM) or 01-03 (458-3SLB)
LE = length from 0 9,000 m in steps of 10 m
C = connect mode
N = connect both CO and CPE ends
P = connect CPE only CO open
O = connect CO only CPE open
Z = open both CO and CPE ends
Example:
SL:02:9000,N = Set length of module in slot 02 to 9000 meters with both CO and CPE
connected.

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator
Page 3 -2
Read Length Command Values: RL:M
Where,
RL = read length
M = module (slot) number 01 16 (458-CM) or 01-03 (458-3SLB)
Example:
RL:02 = Read length of module in slot 02.
3.2
Graphical User Interface
➢
Refer to the 458 Universal GUI Reference Manual for more information.

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator
Page 3 -3
3.3 LCD Display/Front Panel
Basic Operation
Make selections by pushing the UP, DOWN, LEFT and RIGHT arrow buttons on the front panel.
The LCD Display shows the choices made. Refer to the chassis manual for additional details.
Step One Select Slot
•
Navigate to the desired slot in the 458-3SLx (3-Slot) Chassis or 458-CC16/458-CM
(16-Slot) Chassis using the UP or DOWN arrows.
Step Two Select Increment
•
Step through the allowable lengths for the current slot using the LEFT or RIGHT arrow
buttons. The length will increment in 10-m steps.
Step Three Select Noise Levels
•
Use the UP arrow button to select the CO or CPE noise.
•
Adjust the noise level using the LEFT and RIGHT arrow buttons.