Model 458-LM-E1-36-TP100 

 
 

 

  Rev.- 

Date of Publication:02/25/2019 

 
 
 

 

 
 

 

“Results You Can Count On”

 


background image

 

 

Customer Support 

Thank  you  for  your  purchase  of  the  Telebyte  Model  458-LM-E1-36-TP100  Multi-Standard 
Local Loop Simulator. This one-channel product simulates TP100 as specified in ETSI TS 101 
270-1 and G.992.5 Annex M. 
 
 
 
 
 

Contact Information: 

 

Telephone

   

 

 

 

E-mail/Internet

 

 
General: 

 

631-423-3232 

support@telebytebroadband.com 

Technical support:  800-835-3298 

sales@telebytebroadband.com 

Fax:   

 

631-385-8184 

www.telebytebroadband.com 

 

Mail 

 
Telebyte, Inc. 
355 Marcus Blvd 
Hauppauge, NY  11788 
 


background image

 

Customer Care 

Warranty 

One-year Warranty

 

• 

Telebyte will furnish parts and labor for the repair or replacement of products found by Telebyte to be defective 

in material or workmanship during the warranty period.1 
 

 

Extended Customer Care 

 

Refer to the Customer Care section of the Telebyte web site for the most current information on extended 

warranty and calibration contracts 

2,3,4:

 

http://www.telebytebroadband.com/customercare.html

 

 

Disclaimer of Warranties and Other Terms and Conditions 

1

 

TELEBYTE, INC. warrants its broadband simulation equipment to be free from defects in material and workmanship, under normal and proper use 

and in its unmodified condition, for 12-

months, starting on the date it is delivered for use. TELEBYTE’S sole obligation under this warranty shall be to 

furnish parts and labor for the repair or replacement of products found by TELEBYTE to be defective in material or workmanship during the warranty 
period. Warranty repairs will be performed at the point of manufacture. Equipment approved for return for warranty service shall be returned F.O.B. 
TELEBYTE  factory  and  will  be  redelivered  by  TELEBYTE  freight  prepaid,  except  for  non-continental U.S.A.  locations. These  deliveries  will  be  sent 
COD freight and import/export charges. 

 

The customer is responsible for freight and customs charges when shipping products to and from Telebyte for calibration services.

 

You must purchase the extended warranty at the time of purchase or during the initial warranty period.

 

You must  purchase  the calibration  contract  at  the  time  of  purchase  or  during  the initial  warranty  period.  The  above  warranty  is  in lieu  of  all  other 

warranties,  expressed  or  implied,  statutory  or  otherwise,  including  any  implied  warranty  of  merchantability  or  fitness  for  a  particular  purpose. 
TELEBYTE shall not be liable for any damages sustained by reseller or any other party arising from or relating to any equipment failure, including but 
not limited to consequential damages, nor shall TELEBYTE have any liability for delays in replacement or repair of equipment.

 

 


background image

 

Equipment Returns 

 
Out  of  warranty  equipment  may  be  returned,  prepaid,  to  the  Hauppauge,  N.Y. 
customer service facility. Return shipping charges will be billed to the customer. 
The repaired unit will have a 90-day warranty. In those cases where "no trouble" 
is  found,  a  reduced  charge  will  be  billed  to  cover  handling,  testing,  and 
packaging.  Whether  in  or  out  of  warranty,  a  Return  Material  Authorization 
number 

(RMA) 

is 

required 

and 

may 

be 

obtained 

by 

going 

to 

www.telebytebroadband.com and opening a technical support case.  
 
Please be sure to reference the RMA number on the outside container. 
 


background image

 

Table of Contents 

1.0  Introduction .................................................................................................................................. 1-1 
 
2.0  Specifications ............................................................................................................................... 2-1 
2.1  458-LM-E1-30-TP100 .................................................................................................................. 2-1 
2.2  458-3SLB ..................................................................................................................................... 2-1 
2.3 458-CC-16/458-CM ...................................................................................................................... 2-2 
 
3.0 Control .......................................................................................................................................... 3-1 
3.1 Remote Commands ...................................................................................................................... 3-1 
3.1.1 RS-232 (Serial Port) Remote Commands ................................................................................. 3-1 
3.2    Graphical User Interface ............................................................................................................ 3-2 
3.3    LCD Display/Front Panel ........................................................................................................... 3-3 


background image

 

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator w/Optional AWGN Generator 

Page 1-1   

1.0 Introduction 

The Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator is the ideal solution for ADSL, 
ADSL2, ADSL2+, and VDSL2  (including Profile 35b)  chip/modem/DSLAM testing out to 9,000 m in 
very small increments.  
 
This  powerful  local  loop  simulator  is  plugged  into  our  Model  458-3SLB  (3-Slot)  or  458-CC-16  (16 
Slot)  chassis  where  settings  are  controlled  by  a  convenient  keypad  located  on  the  front,  RS-232, 
Ethernet or IEEE-

488(GPIB). The modular design of Telebyte’s products allows the 458-LM-E1-36-

TP100 to be combined with other line modules for a wide variety of test configurations. 

 


background image

 

Model 458-LM-E1-36-TP100 

Page 2-1   

2.0 Specifications 

2.1 458-LM-E1-36-TP100 
 

Product Specifications 

 

Simulation 

 

Accurately simulates attenuation and impedance 

 

Full bidirectional operation at all specified frequencies 

 

TP100 as specified in ETSI TS 101 270-1 & G.992.5 Annex M  

Bandwidth 

DC to 36 MHz  

Attenuation Accuracy 

TR-114 Issue 3 TP100 test loops (150m, 300m, 450m, 600m, 900m, 1050m, 
1200m, 1500m, 2000m, 2500m, 3000m)  
MAE < 0.5dB    
 
All other loop lengths TP100: Typically, MAE < 1 dB 20 kHz to 36 MHz 
(when source and load impedances are 100 ohms) 

Maximum Attenuation 

> 90 dB 

Impedance Accuracy 

Typically, +/- 10% 

Maximum Voltage Tip   Ring 

200 V 

Maximum Current 

130 mA 

Connectors 

2 RJ-

45’s on front 

 
 
2.2 458-3SLB 

 

458-3SLB Product Specifications (3-Slot Chassis and Control Module) 
Controls 

Keypad for setting loop lengths and IEEE-488 address, RS-232, or Ethernet 
communication parameters. 

Indicators 

Backlit LCD display of line length and set up parameters. 

Power 

88 to 264 VAC, 50 or 60 Hz 

Size 

[2U] 19 in W x 22 in D x 3.47 in H (482.6 mm W x 558.8 mm D x 88.1 mm H) 

Environmental 

Operating: +32 F to +122 F (0 to +50 degrees C) 
Storage: 0 to 95% relative humidity (non-condensing) 

Remote Control Connectors 

RS-232: DB9 female (DCE); GPIB:IEEE488 24-pin connector. Ethernet: RJ-45 

Plug-In Compatibility 

Accepts 1-3 458 plug-in modules 


background image

 

Model 458-LM-E1-36-TP100 

Page 2-2   

2.3 458-CC-16/458-CM 

 

Product Specifications 458-CC-16 (16-Slot Chassis) & 458-CM (sold separately) 
Controls 

Keypad for setting loop lengths and IEEE-488 address, RS-232, or Ethernet 
communication parameters. 

Indicators 

Backlit LCD display of line length and set up parameters. 

Power 

100 - 240 VAC, 50 or 60 Hz 

Size 

[7U] 19 in W x 22 in D x 12.22 in H  
(482.6 mm W x 558.8 mm D x 310.4 mm H) 

Environmental 

Operating: +32 F to +122 F (0 to +50 degrees C) 
Storage: 0 to 95% relative humidity (non-condensing) 

Remote Control Connectors 

RS-232: DB9 female (DCE); GPIB:IEEE488 24-pin connector. Ethernet: RJ-45 

Plug-In Compatibility 

Accepts 1-16 458 Line Modules 

 

   

Specifications are subject to change without notice. Made in USA.  

 

 
 

  Detailed information about the operation of the 458-3SLB and 458-CC-16/458-CM can be 

found in the reference manuals for those products. Only information specific to the 458-LM-
E1-36-TP100 is provided in this manual. 


background image

 

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator 

Page 3 -1   

 

3.0 Control 

The  Model  458-LM-E1-36-TP100  can  be  controlled  three  ways:  via  RS-232  and  IEEE488  Remote 
Commands, our 458 Universal Graphical User Interface or the LCD display and buttons on the front 
panel of our 458-3SLB or 458-CM. 

 

3.1 Remote Commands 

 

Please refer to the manuals for the 458-3SLB or 458-CC-16/458-CM for remote commands common 
to many line modules, including the 458-LM-E1-36-TP100. This manual contains  commands unique 
to this module.   

 

3.1.1 RS-232 (Serial Port) Remote Commands 

 
Set Length Command Values: SL:M:LE,C 

 
Where,  
 
SL = set length 
 
M = module (slot) number 01   16 (458-CM) or 01-03 (458-3SLB) 
 
LE = length from 0   9,000 m in steps of 10 m 
 
C = connect mode 
 
    N = connect both CO and CPE ends 
    P = connect CPE only CO open 
    O = connect CO only CPE open 
    Z = open both CO and CPE ends 
 
Example: 
 
SL:02:9000,N  =  Set  length  of  module  in  slot  02  to  9000  meters  with  both  CO  and  CPE 
connected. 
 


background image

 

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator 

Page 3 -2   

Read Length Command Values: RL:M 

 
Where, 
 
RL = read length 
 
M = module (slot) number 01   16 (458-CM) or 01-03 (458-3SLB) 
 
Example: 
 
RL:02 = Read length of module in slot 02. 
 

 

3.2 

Graphical User Interface 

 

 
 

  Refer to the 458 Universal GUI Reference Manual for more information.  

 


background image

 

Model 458-LM-E1-36-TP100 Multi-Standard Local Loop Simulator 

Page 3 -3   

3.3 LCD Display/Front Panel 
 

Basic Operation 

 

Make selections by pushing the UP, DOWN, LEFT and RIGHT arrow buttons on the front panel. 
The LCD Display shows the choices made. Refer to the chassis manual for additional details.

 

 

Step One   Select Slot 
 

  Navigate to the desired slot in the 458-3SLx (3-Slot) Chassis or 458-CC16/458-CM  

(16-Slot) Chassis using the UP or DOWN arrows. 

  

Step Two   Select Increment 
 

  Step through the allowable lengths for the current slot using the LEFT or RIGHT arrow 

buttons. The length will increment in 10-m steps.  

 

Step Three   Select Noise Levels 

 

  Use the UP arrow button to select the CO or CPE noise. 