2 x ISDN BRI; 4 DSP channels
VoIP and fax over IP (T.38)
CAPI server virtualisation + fax G3
5 x Gigabit Ethernet
19 inch housing with integrated power supply
IPSec - 10 tunnels, opt. up to 110, HW acceleration
Web-based configuration / wizards

The flexible media gateway

bintec RT1202

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 2 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

The flexible media gateway

The RT1202 media and VPN gateway has two S0 interfaces that can be configured as desired.
The 4 ISDN B channels and the integrated 4-channel DSP permit 4 simultaneous hybrid
connections for voice (VoIP) and fax (FoIP) transmissions.

High-end ISDN media and VPN gateway

The bintec RT1202 is a powerful and, thanks to its comprehensive equipment, flexible media and
VPN gateway. With its 19-inch metal housing and highly efficient internal switched-mode power
supply the fan-free and hard drive-free design guarantees long-term reliability in critical
corporate applications.
Two configurable BRI interfaces (NT/TE) for the use of up to 4 ISDN B-channels and the
integrated 4-channel DSP permit four simultaneous hybrid voice connections (VoIP) and fax
traffic (FoIP).
The device has five Gigabit Ethernet ports, which can be configured for LAN, WAN or DMZ, and
comes with a licence for 10 out of a possible 110 hardware-accelerated IPSec tunnels. This
makes the RT1202 ideal for use as a media and VPN gateway in SMEs and company head offices.

Remote CAPI

As the remote CAPI is a network application, which operates
independently of the MS Windows© operating system software, it is
ideal for server use. Consequently, CAPI applications can be installed
and maintained without suspending operation and no reboot of the
server is required. The software supports 16/32/64 Bit operating
systems and applications. The remote CAPI is also available for Linux.
This function is groundbreaking for the use of virtual machines. MS
Hyper-V©, MS virtual PC©, VMware©, virtualBox© and other virtual
platforms do not offer an option to connect ISDN cards. The bintec
remote CAPI avoids this problem and
thereby allows fax and unified communication servers to be operated
on virtual systems.

The following partners have already successfully certified our solution:
Servonic (IXI), Tobit (David), COM2 (TWINFAX), GFI (Faxmaker),
ppedv(Visendo)

bintec RT1202

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 3 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

VoIP Media Gateway

With the RT1202 up to 4 telephone calls and fax transmissions (T.38)
can be transferred simultaneously between the IP network and the
traditional telephone network. This can be carried out either directly as
a terminal adapter (an ISDN telephone is registered with the VoIP
provider) or using a PBX.
A traditional ISDN PABX can be coupled with SIP providers or a modern
IP PABX can be operated on the ISDN BRI/PRI exchange connection. Fax
transmission over T.38 is supported in both scenarios. A fax device on
the analogue connection of the traditional PABX can thus send and
receive faxes over the SIP provider. This allows FoIP clients and servers
in the LAN to fax over the ISDN exchange.
The G.711, G.726 and G.729A voice coding offered by the SIP trunking
and DDI-capable Teldat Media Gateway can be adapted to suit your
quality requirements and thereby ensure ISDN quality and high
compression. Echoes are successfully suppressed in G.168.
Fax over IP, T.38, permits implementation of the analogue T.30 group 3
fax protocol.
Thanks to the intelligent quality of service bandwidth management and
adjustment, you can prioritise voice traffic over normal data traffic over
the internet, for example, and thereby always ensure sufficient
bandwidth for your IP voice connections.
Pure VoIP calls are not limited and are only restricted in terms of
number by the existing bandwidth for the provider.
Media gateways are certified by:

Swyx with its Swyxware communication solution

Addix with its Asterisk Appliance Astimax

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 4 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Routing and VPN gateway

The additional media services, which the bintec RT Series permits, in no
way restrict the standard scope of functions of the bintec R Series. You
can use the entire scope of services of the VPN gateway with identical
data rates in parallel to media services.
bintec gateways have features that go far beyond just IP routing and
allow it to be seamlessly integrated into complex IT infrastructures.
As routing protocols, you can use RIP, OSPF or the Multicast routing
protocol PIM-SM for example, and the comprehensive multicast support
makes the device ideal for use in multimedia and streaming
applications.
Even the basic equipment provides a SIP application level gateway
(ALG) for the direct connection of IP telephones in the network or for
registering with a VoIP provider. The ALG automatically controls the
internal firewall making it easier to configure your VoIP solution, if the
media gateway is not active.
You can prioritise voice traffic over normal data traffic using QoS
support. If required you can give normal data traffic priority over e-mail
traffic.
The DNS proxy function supports the LAN for address implementation
and the automated IP configuration of PCs is carried out over an
integrated DHCP server. The time server allows you to send the current
time to all computers in the LAN without having to query each
computer on the internet.

The VPN IPSec solution works both with preshared keys as well as with
certificates for authentication, which allows a public key infrastructure
to be created for maximum security.
Furthermore, the bintec IPSec implementation offers support when
creating VPN connections with dynamic public IP addresses. The
exchange of IP addresses is carried out either over dynamic DNS
providers or directly over ISDN.
IKE Config Mode and X-Auth (extended authentication) permit IPSec
dialin solutions for multiple clients with minimal costs and one-time
password ensuring the highest level of security.
The professional functions are rounded off with bundling for parallel
internet connections with load balancing and our bintec Router
Redundancy Protocol (BRRP).
VPN gateways are certified by Kobil with "Secure One Time Verification
and Identification" (SecOVID) and Starface, amongst others, which
realise secure IP PABX connections over VPN with VoVPN.

Simple configuration and maintenance

The gateway is configured over the Configuration Interface (FCI), using the integrated
configuration wizards for example. The FCI is a web-based graphic user surface that you can use
from any PC with an up-to-date Web browser via an HTTP or encrypted HTTPS connection. It also
offers the opportunity to manage the devices locally and remotely over other configuration
accesses such as Telnet, SSH and ISDN login.

DIME Manager from Teldat is a free tool for managing Teldat devices.

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 5 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

DIME Manager is aimed at administrators who manage networks with up to 50 devices. The
software simplifies the management and configuration of gateways or access points either
individually or in logical groups.
When developing DIME Manager, simple and efficient operation was the primary aim. It allows,
for example, software updates to be applied to individual devices or groups of devices simply by
drag and drop. DIME Manager recognises and manages new devices in the network using SNMP
multicasts, in other words independent of their current IP address.

Variants

bintec RT1202 - UK (5510000265)

IP Access Media Gateway; 19 inch rack; 2x ISDN BRI; 4x DSP; T.30/T.38 fax
support; incl. 10 IPSec tunnels (opt. max. 110), certificates, HW encryption; 4+1
Gigabit Eth. switch; UK version.

bintec RT1202 (5510000228)

IP Access Media Gateway; 19 inch rack; 2x ISDN BRI; 4x DSP; T.30/T.38 fax
support; incl. 10 IPSec tunnels (opt. max. 110), certificates, HW encryption; 4+1
Gigabit Eth. switch; german and intern. version.

Features

Remote CAPI / Fax Media Gateway

Multiserver CAPI

A computer can use several CAPI server simultaneously.

Multisite CAPI

Several computer can use the same BRI port

Access Control

Prevention by user passwort concept

ISDN server virtualising

Unlimited usage on virtual computers

Fax profile

Fax group 3

Number of parallel fax channels

4 fax channels

Maximum data rate

14,400 Baud

Fax standard

Fax protocol T.30

Protocols for fax data
transmission

Fax data transmission according V.21, V.27, V.29, V.17

CAPI controller features

CAPI possibilities: Internal controller, supplementary services, DTMF (MFV), HOLD, ECT, 3PTY, CF,
CD, MWI

B channel layer 1 protocols

64 kbps HDLC, 64 kbps bit transparent, V.110, T.30 fax G3, 56 kbps bit transparent

B channel layer 2 protocols

ISO 7776 (X.75 SLP), transparent, LAPD D-CH X.25 (SAPI 16), T.30 fax G3, PPP, V.120 asyn., V.120
Bit transparent, LAPD free SAPI

B channel layer 3 protocols

Transparent, T70/90NL, ISO 8208 (X.25 DTE-DTE), X25DCE, T.30 fax G3, T.30 fax G3 extended

Fax data compression standards

T.4 (MH-, MR compression), T.6 (MMR compression)

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 6 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

VoIP Media Gateway

DSP support

VoIP and FoIP codecs are executed digital signal processors. Computation does not charge the
system and is dedicated reserved for each channel. Constant codec quality, independent of system
load, is guaranteed.

SIP user

No software limitation

SIP registrar

SIP users are able to sign on at the media gateway with registration and authentication.

SIP proxy

Mapping of an unlimited number of SIP single or DDI provider accounts to SIP single user or to VoIP
PABXs.

SIP ISDN gateway

Transparent conversion of connections of a VoIP PABX to ISDN trunk

ISDN SIP gateway

Transparent conversion of ISDN PABX connections to single SIP provider, or to DDI SIP trunk access

SIP trunk

With 'SIP PBX Trunking' respectively SIP DDI Internet telephony has got all essential features of
ISDN. Especially Direct Dial In (DDI), which allows to assign single telephone numbers (DDI
numbers) to extensions and departments.

ISDN trunk

Support of two or more ISDN connections in point-to-point mode (BRI or PRI), which are configuered
as TE (collective line) or NT

SIP link

Switching of incoming and outgoing calls like SIP trunks, though without DDI, but with single calling
number blocks, with or without registerin

Call router

Flexible switching of all calls according rules; conditions for call forwarding (routing). List with rules
or rule chains for manipulating the signalled target calling number

CLID conversion

Manipulation of calling party numbers in incoming calls; add a prefix to incoming numbers, to route
corresponding calls via a certain SIP account.

Calling number transformation

Conversion list of calling numbers; in this list are correlated external and internal numbers.

Backup routes

Unlimited number of backup routes for the automatic selection of outside lines, (e.g. Prio 1 SIP
provider is not available, Prio 2 SIP provider returns line busy, call will be switched Prio 3 via ISDN)

Number of simultaneous VoIP
connections

No software limitation

Number of simultaneous hybrid
connections

4 ISDN <-> SIP hybrid connections, independ of applied codecs by DSP HW support

Features hybrid connections

Echo cancellation according G.168, Comfort Noise Generation CNG

DTMF support

Support of DTMF inband and out of band according standards RFC 2976 (SIP info) and RFC 2833
(RTP payload type/outband)

Audio Codec support

G.711, G.726 (16 kbps), G.726 (24 kbps), G.726 (32 kbps), G.726 (40 kbps), G.729

Audio Codec prioritisation

Selectable handshaking sequences, with priorization according quality, low or high bandwidth

Fax transmission

4 channels can be simultaneous converted from LAN fax T.38 to T.30, ISDN an analogue. No matter
how high the system load, for each channel is supported by a DSP.

Terminal adapter SIP <-> ISDN

Imaging of ISDN end devices to SIP and imaging of SIP end devices to ISDN, maximum of 4
simultaneous connections

SIP protocols

UDP, TCP, TLS

SIP features

CLIP, CLIR. REFER, PRACK, SESSION timers, HOLD, MOH, INFO, NAPTR, ...

SIP RFCs

2327, 2976, 3261, 3262, 3263, 3264, 3311, 3323, 3325, 3428, 3515, 3581, 3608, 3891, 3966,
4028, 3555, 2833, 1035, 2782, 2915, 2617, ...

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 7 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

VoIP Media Gateway

SIPS

SIP secure (TLS), establish secure calls

Media protocols

RTP, SRTP

Debug trace

Recording of all data streams via console and web configuration. Selectable trace formats: text
PCAP

ISDN

CAPI

CAPI 2.0 with CAPI user concept (password for CAPI use)

ISDN protocols

Euro-ISDN (Point-to-mulitpoint/Point-to-point)

ISDN leased lines

Supported leased lines: D64S, D64S2, TS02, D64S2Y

ISDN auto-configuration

Automatic recognition and configuration of ISDN protocols

B channel protocols

Excellent interoperability with other manufacturers (Raw HDLC, CISCO HDLC, X.75)

X.31 over CAPI

Support for various connection paths: X.31/A for ISDN D-channel, X.31/A+B for ISDN B-channel,
X.25 within ISDN B-channel (also leased lines)

Bit rate adaption

V.110 (1,200 up to 38,400 bps), V.120 up to 57,600 kbps (HSCSD) for connection to GSM
subscribers

VPN

PPTP (PAC/PNS)

Point to Point Tunneling Protocol for establishing fo Virtual Privat Networks, inclusive strong
encryption methods with 128 Bit (MPPE) up to 168 Bit (DES/3DES, Blowfish)

PPP / PPTP hardware
acceleration

Integrated hardware acceleration for PPP/PTPP encryption algorithms DES, 3DES, MPPE

GRE v.0

Generic Routing Encapsulation V.0 according RFC 2784 for common encapsulation

L2TP

Layer 2 tunnelling protocol inclusive PPP user authentication

Number of VPN tunnels

Inclusive 110 active PPTP, L2TP and GRE v.0 tunnels (also in combination possible)

IPSec

Internet Protocol Security establishing of VPN connections

Number of VPN tunnels

Inclusive 10 active VPN tunnels, optional up to 110 IPSec tunnels

IPSec Algorithms

DES (64 Bit), 3DES (192 Bit), AES (128,192,256 Bit), CAST (128 Bit), Blowfish (128-448 Bit), Twofish
(256 Bit); MD-5, SHA-1, RipeMD160, Tiger192 Hashes

IPSec hardware acceleration

Integrated hardware acceleration for IPSec encryption algorithms DES, 3DES, AES inclusive
hardware acceleration for MD-5, SHA-1 Hash generation

IPSec IKE

IPSec key exchange via preshared keys or certificates

IPSec IKE Config Mode

IKE Config Mode server enables dynamic assignment of IP addresses from the address pool of the
company. IKE Config Mode client enables the router, to get assigned dynamically an IP address.

IPSec IKE XAUTH (Client/Server)

Internet Key Exchange protocol Extended Authenticaion client for login to XAUTH server and
XAUTH server for loging of XAUTH clients

IPSec IKE XAUTH (Client/Server)

Inclusive the forwarding to a RADIUS-OTP (One Time Password) server (supported OTP solutions
see www.bintec-elmeg.com).

IPSec NAT-T

Support of NAT-Traversal (Nat-T) for the application at VPN lines with NAT

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 8 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

VPN

IPSec IPComp

IPSec IPComp data compression for higher data throughput via LZS

IPSec certificates (PKI)

Support of X.509 multi-level certificates compatible to Micrososft and Open SSL CA server; upload
of PKCS#7/8/10/12 files via TFTP, HTTP, HTTP, LDAP, file upload and manual via FCI

IPSec SCEP

Certificates management via SCEP (Simple Certificate Enrollment Protocol)

IPSec Certificate Revocation
Lists (CRL)

Support of remote CRLs on a server via LDAP or local CRLs

IPSec Dead Peer Detection
(DPD)

Continuous control of IPSec connection

IPSec dynamic IP via ISDN

Transmission of dynamic IP address in ISDN D or B channel; free-of-charge licence necessary

IPSec dynamic DNS

Enables the registering of dynamic IP addresses by a dynamic DNS provider for establishing a IPSec
connection.

IPSec RADIUS

Authentication of IPSec connections at a RADIUS server. Additionally the IPSec peers, which were
configured on a RADIUS server, can be loaded into the gateway (RADIUS dialout).

IPSec Multi User

Enables the Dial-in of several IPSec clients via a single IPSec peer configuration entry

IPSec QoS

The possibility to operate Quality of Service (traffic shaping) inside of an IPSec tunnel

IPSec NAT

By activating of NAT on an IPSec connection it is possible, to implement several remote locations
with identical local IP addess networks in different IP nets for the VPN connection

IPSec throughput (1400)

86 Mbps with 1400 Byte packets with AES 256 / AES 128 / 3 DES encryption

IPSec throughput (256)

19 Mbps with 1400 Byte packets with AES 256 / AES 128 / 3 DES encryption

Security

NAT/PAT

Symmetric Network and Port Address Translation (NAT/PAT) with randomly generated ports
inclusive Multi NAT (1:1 translation of whole networks)

Policy based NAT/PAT

Network and Port Address Translation via different criteria like IP protocols, source/destination IP
Address, source/destination port

Policy based NAT/PAT

For incoming and outgoing connections and for each interface variable configurable

Content Filtering

Optional ISS/Cobion Content filter (30 day test license inclusive)

Stateful Inspection Firewall

Packet filtering depending on the direction with controling and interpretation of each single
connection status

Packet Filter

Filtering of IP packets according to different criteria like IP protocols, source/destination IP address,
source/destination port, TOS/DSCP, layer 2 priority for each interface variable configurable

Routing

Policy based Routing

Extended routing (Policy Based Routing) depending of diffent criteria like IP protocols (Layer4),
source/destination IP address, source/destination port, TOS/DSCP, source/destination interface and
destination interface status

Multicast IGMP

Support of Internet Group Management Protocol (IGMP v1, v2, v3) for the simultaneous distribution
of IP packets to several stations

Multicast IGMP Proxy

For easy forwarding of multicast packets via dedicated interfaces

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 9 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Routing

Multicast Routing Protocol PIM
SM

Protocol Independent Multicast (PIM) distributes information via a central Rendezvous Point Server.
PIM Modus Sparse Mode (SM) forwards only packets to groups which have been requested

Multicast inside IPSec tunnel

Enables the transmission of multicast packets via an IPSec tunnel

RIP

Support of RIPv1 and RIPv2, separated configurable for each interface

Extended RIP

Triggerd RIP updates according RFC 2091 and 2453, Poisened Rerverse for a better distribution of
the routes; furthermore the possibility to define RIP filters for each interface.

OSPF

Support of the dynamic routing protocol OSPF

BGP4

On request

Routing throughput (1518)

199 Mbps with 1518 Byte packets

Routing throughput (256)

198 Mbps with 256 Byte packets

Protocols / Encapsulations

PPP/MLPPP

Support of Point to Point Protocol (PPP) for establishing of standard PPP connections, inclusive the
Multilink extension MLPPP for the bundeling of several connections

PPPoE (Server/Client)

Point-to-Point Protocol over Ethernet (Client and Server) for establisching of PPP connections via
Ethernet/DSL (RFC 2516)

MLPPPoE (Server/Client)

Multilink extension MLPPPoE for bundeling several PPPoE connections (only if both sides support
MLPPPoE)

DNS

DNS client, DNS server, DNS relay and DNS proxy

DYN DNS

Enables the registering of dynamic assigned IP addresses at adynamic DNS provider, e.g. for
establishing of VPN connections

DNS Forwarding

Enables the forwarding of DNS requests of free configurable domains to assigned DNS server.

DHCP

DHCP Client, Server, Proxy and Relay for siplified TCP/IP configuration

Packet size controling

Adaption of PMTU or automatic packet size controling via fragmentation

X.25 Enhanced

Optional: X.25 over ISDN, XOT, X.25 to TCP Gateway, X.25 PAD, TP0 Bridge

Quality of Service (QoS)

Policy based Traffic Shapping

Dynamic bandwidth management via IP traffic shaping

Bandwidth reservation

Dynamic reservation of bandwidth, allocation of guaranteed and maximum bandwidths

DiffServ

Priority Queuing of packets on the basis of the DiffServ/TOS field

Layer2/3 tagging

Conversion of 802.1p layer 2 priorisation information to layer 3 diffserv attributes

TCP Download Rate Control

For reservation of bandwidth for VoIP connections

Redundancy / Loadbalancing

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 10 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Redundancy / Loadbalancing

BRRP

Bintec Router Redundancy Protocol for backup of several passive or active devices with free
selectable priority

BoD

Bandwidth on Demand: dynamic bandwidth to suit data traffic load

Load Balancing

Static and dynamic load balancing to several WAN connections on IP layer

VPN backup

Simple VPN backup via different media. Additional enables the Teldat interface based VPN concept
the application of routing protocols for VPN connections.

Layer 2 Functionality

Bridging

Support of layer 2 bridging with the possibility of separation of network segment via the
configuration of bridge groups

VLAN

Support of up to 32 VLAN (Virtual LAN) for segmentation of the network in independent virtual
segments (workgroups)

Proxy ARP

Enables the router to answer ARP requests for hosts, which are accessible via the router. That
enables the remote clients to use an IP address from the local net.

Logging / Monitoring / Reporting

Internal system logging

Syslog storage in RAM, display via web-based configuration user interface (http/https), filter for
subsystem, level, message

External system logging

Syslog, several syslog server with different syslog level configurable

E-Mail alert

Automatic E-Mail alert by definable events

SNMP traps

SNMP traps (v1, v2, v3) configurable

Activity Monitor

Sending of information to a PC on which Brickware is installed

IPSec monitoring

Display of IPSec tunnel and IPSec statistic; output via web-based configuration user interface
(http/https)

Interfaces monitoring

Statistic information of all pysical and logical interfaces (ETH0, ETH1, SSIDx, ...), output via
web-based configuration user interface (http/https)

ISDN monitoring

Display of active and past ISDN connections; output via web-based configuration user interface
(http/https)

IP accounting

Detailed IP accounting, source, destination, port, interface and packet/bytes counter, transmission
also via syslog protocol to syslog server

ISDN accounting

Detailed ongoing recording of ISDN connection parameter like calling number and charging
information, transmission also via syslog protocol to syslog server

RADIUS accounting

RADIUS accounting for PPP, PPTP, PPPoE and ISDN dialup connections

Keep Alive Monitoring

Control of hosts/connections via ICMP polling

Tracing

Detailed traces can be done for different protocols e.g. ISDN, PPPoE, ... generation local on the
device and remote via DIME Manager

Tracing

Traces can be stored in PCAP format, so that import to different open source trace tools (e.g.
wireshark) is possible.

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 11 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Administration / Management

RADIUS

Central check of access authorization at one or several RADIUS server, RADIUS (PPP, IPSec
inclusive X-Auth and login authentication)

RADIUS dialout

On a RADIUS server configured PPP und IPSec connection can be loaded into the gateway (RADIUS
dialout).

TACACS+

Support of TACACS+ server for login authentication and for shell comando authorization

Time synchronization

The device system time can be obtained via ISDN and from a SNTP server (up to 3 time server
configurable). The obtained time can also be transmitted per SNTP to SNTP clients.

Automatic Time Settings

Time zone profiles are configurable. That enables an automatic change from summer to winter
time.

Supported management
systems

DIME Manager, XAdmin

Configurable scheduler

Configuring of time and event controlled tasks, e.g. reboot device, activate/deactivate interface,
activate/deactivate WLAN, trigger SW update and configuration backup

Configuration Interface (FCI)

Integrated web server for web-based configuration via HTTP or HTTPS (supporting self created
certificates). This user interface is by most of bintec elmeg GmbH products identical.

Software update

Software updates are free of charge; update via local files, HTTP, TFTP or via direct access to the
bintec elmeg web server

Remote maintenance

Remote maintenance via telnet, SSL, SSH, HTTP, HTTPS and SNMP (V1,V2,V3)

Configuration via serial interface

Serial configuariton interface is available

ISDN remote maintenance

Remote maintenance via ISDN dial-in with checking of the calling number. The ISDN remote
maintenance connection between two bintec elmeg devices can be encrypted.

ISDN remote maintenance

A transparent mode enables transmissions of configurations and software updates respectively

GSM remote maintenance

Remote maintenance via GSM login (external modem and cable required)

Device discovery function

Device discovery via SNMP multicast.

On The Fly configuration

No reboot after reconfiguration required

SNMP

SNMP (v1, v2, v3), USM model, VACM views, SNMP traps (v1, v2, v3) configurable, SNMP IP access
list configurable

SNMP configuration

Complete management with MIB-II, MIB 802.11, Enterprise MIB

Configuration export and import

Load and save configurations, optional encrypted; optional automatic control via scheduler

SSH login

Supports SSH V1.5 and SSH V2.0 for secure connections of terminal applications

HP OpenView

Integration into Network Node Manager

XAdmin

Support of XAdmin roll out and configuration managemant tool for larger router installations
(IP+ISDN+GSM)

Interfaces

Ethernet

5 x 10/100/1000 Mbps Ethernet Twisted Pair, autosensing, Auto MDI/MDI-X, up to 4 ports can be
switches as additional WAN ports incl. load balancing, all Ethernet ports can be configured as LAN
or WAN.

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 12 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Interfaces

Serial console

Serial console interface / COM port (mini USB): optional, connection of an analogue / GPRS modem
is possible (supported modems: see www.bintec-elmeg.com)

ISDN Basic Rate (BRI)

2 x BRI (NT/TE), each 2 B channel, internal/external

Hardware

19 inch

Mountable in 19 inch rack, incl. 19 inch rack mount kit

Realtime clock

System time persists even at power failure for some hours.

Environment

Temperature range: Operational 0°C to 40°C; storage -10°C to 70°C; Max. rel. humidity 10 - 95%
(non condensing)

Power supply

Integrated wide range power supply 110-240V, with energy efficient swiching controller

Power consumption

Max. 15 Watt, typ. 13 Watt

Housing

19 inch 1 high unit metal case, screw-on 19 inch mounting-angle, LEDs and network connectors at
front side

Dimension

Ca. 485.6 mm x 220 mm x 45 mm (W x H x D)

Weight

Ca. 2600g

Fan

Fanless design therefor high MTBF

Reset button

Restart or reset to factory state possible

Standards and certifications

R&TTE directive 1999/5/EG; EN 55022; EN 55024 + EN 55024/A1; EN61000-3-2; EN 61000-3-3; EN
61000-4-4; EN 60950-1; EN 300 328

Content of Delivery

Manual

Quick Installation Guide in German and English

DVD

DVD with system software, management software and documentation

Ethernet cable

1 Ethernet cable, 3m

Network cable

Power cable

Serial cable

Serial cable (mini USB - DSUB 9 female)

ISDN (BRI/S0) cable

ISDN (BRI/S0) cable, 3m

Service

Warranty

2 year manufacturer warranty inclusive advanced replacement

Software Update

Free-of-charge software updates for system software (BOSS) and management software (DIME
Manager)

Options

MPPC and Stac compression

Free-of-charge license for Stac and MPPC compression; registration at www.bintec-elmeg.com
required

 


background image

bintec RT1202

03.12.2013

Subject to technical alterations

Page 13 / 13

Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany

Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25

E-Mail: info@teldat.de - www.teldat.org

Options

IP address ISDN B/D channel
license

Free of charge license for IP address transmission in ISDN D or B channel for IPSec connections;
registering under www.bintec-elmeg.com required.

Accessoires

Software Licenses

Rxx02/RTxx02/RXL12xxx-IPSEC25
(5500000781)

Additional 25 IPSec tunnel license for Rxx02, RTxx02 and RXL12xxx series

Rxx02/RTxx02-X25 (5500000783)

License for X.25/XOT/X25toTCP for Rxx02 and RTxx02 series

Cobion Content Filter Small (80551)

Cobion content filter for RSxxx, Rxx02, RTxx02 series; R230a(w), R232b(w), TR200,
R1200(w/wu), R3000(w), R3400, R3800, R232aw; list price for one year

Pick-up Service / Warranty Extension

Service Package 'medium' (5500000812)

Warranty extension of 3 years to a total of 5 years, including advanced
replacement for Teldat products of the category 'medium'. Please find a detailed
description as well as an overview of the categories on
www.teldat.de/servicepackages.

Product Services

HotSpotHosting 1yr 1 location (5510000198)

HotSpot solution hosting fee for 1 year and 1 location

HotSpotHosting 2yr 1 location (5500000861)

HotSpot solution hosting fee for 2 year and 1 location

Additional HotSpot location (5510000199)

Additional location for the HotSpot solution (551000198, 5500000861) valid for one
year

Cables

Console Cable MiniUSB to DSUB9
(5500000717)

Serial console cable for RS, RT, Rxx02 Series and hybird (Mini USB to D-SUB 9)