PDF User Manual

  1. Home
  2. Manuals
  3. Teldat Teldat-Dm 776-I Manual

Teldat Teldat-Dm 776-I Manual

Made by: Teldat
Type: Manual
Category: Network Card
Pages: 18
Size: 1.48 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

PoE Power over Ethernet

Teldat-Dm 776-I

Copyright© Version 11.03 Teldat SA

Teldat SA

Manual

PoE Power over Ethernet

1

 


background image

Legal Notice

Warranty

This publication is subject to change.

Teldat offers no warranty whatsoever for information contained in this manual.

Teldat is not liable for any direct, indirect, collateral, consequential or any other damage connected to the delivery,
supply or use of this manual.

Manual

Teldat SA

2

PoE Power over Ethernet

 


background image

Table of Contents

I

Related Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Chapter 1

Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1.1

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.3

Configuration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

1.4

Viewing the PSE configuration prompt . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

1.5

Configuring PSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

1.5.1

? (HELP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.5.2

AVAILABLE-POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.5.3

DEFAULT-PORT-CONSUMPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.5.4

ENABLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

1.5.5

LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

1.5.6

NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

1.5.7

PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

1.5.8

TRACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

1.5.9

EXIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Chapter 2

Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.1

Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.2

Viewing the PSE monitoring prompt

. . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.3

Monitoring PSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.3.1

? (HELP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.3.2

DISABLE-PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

2.3.3

ENABLE-PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

2.3.4

LIST-STATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

2.3.5

MODE-PORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

2.3.6

REGISTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

2.3.7

RESTART-PSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

2.3.8

EXIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Teldat SA

Table of Contents

PoE Power over Ethernet

i

 


background image

Table of Contents

Teldat SA

ii

PoE Power over Ethernet

 


background image

I Related Documents

Teldat-Dm 772-I Common Configuration Interfaces

Teldat SA

Related Documents

PoE Power over Ethernet

1

 


background image

Chapter 1 Configuration

1.1 Introduction

With the advent and rapid spread of IP telephony based on Ethernet Interfaces, a mechanism to supply power to net-
work devices over existing infrastructures has become necessary. At the same time, devices that are able to provide
backup mechanisms and centrally manage the power supplied to these network devices are also needed.

Thanks to the IEEE. 802.3af Power Over Ethernet (PoE) standard, up to 15.4 watts of DC power can be delivered
over the Ethernet copper cable. This allows for new network powered devices to be integrated on existing LAN infra-
structures, without having to resort to more cabling or power supplies.

In addition, the IEEE PoE standard allows power sourcing equipment (PSE) and the powered device (PD) to signal
one another. This way, the power source can identify the device and determine the amount of power required (thus
enabling efficient management of the power provided).

We have developed some modules that are capable of providing PSE functionality to certain devices with switch
functionality. They all share the configuration and monitoring described in this manual.

1.2 Installation

The external power source of routers with this functionality must be connected to the PSE connector before the
device is switched on.

Fig. 1: Rear panel of an 8 Port Switch Device:

Fig. 2: Rear panel of a 16 Port Switch Device:

Each Switch port has two LEDs. One of them is yellow and indicates the status of the port at the delivered power
level:

Frequency

Off

Open Circuit.

On

Correct class has been detected and power is applied or forced.

Rapid blinking

Shortcut detected.

1 Configuration

Teldat SA

2

PoE Power over Ethernet

 


background image

Slow blinking

Detection error (Strength: High or Low).

1.3 Configuration Commands

This chapter describes the power sourcing equipment (PSE) configuration commands and is divided into the follow-
ing sections:

• Viewing the PSE configuration prompt.

• PSE configuration commands.

1.4 Viewing the PSE configuration prompt

To access the configuration environment, do the following:

(1)

At the GESTCON (*) prompt, enter PROCESS 4 (or P 4) or CONFIG.

(2)

At the configuration prompt (Config>), enter NETWORK <interface_name> (interface_name is the name of
the Ethernet interface on which the PSE functionality can be used).

(3)

To set specific POE parameters, use the available commands from the PSE configuration menu described in
this chapter. To access the menu corresponding to the specific parameters, enter the POWER-
SOURCING-EQUIPMENT 
command once inside the interface configuration.

*config

Config>net ethernet0/0

-- Ethernet Interface User Configuration –
ethernet0/0 config>?

description

Enter interface description

input-buffers

Number of rx buffers

ip

Interface Internet Protocol config commands

ip-encapsulation

IP transport mode in the ethernet frame

list

Displays the current configuration

llc

Displays the LLC configuration prompt

mac-address

Adopt locally administered addresses

no
power-sourcing-equipment

Access to the Power Sourcing Equipment configuration

repeater

Access to the repeater configuration

shutdown

Change state to administratively down

update

Update a level indicator

exit

ethernet0/0 config>power-sourcing-equipment

-- Power Sourcing Equipment configuration --
ethernet0/0 PSE config>

Certain commands are common to all device interfaces. These commands are described in the manual on common
configuration interfaces (Teldat-Dm772-I Common Configuration Interfaces).

1.5 Configuring PSE

This section describes the PSE configuration commands.

Command

Function

? (HELP)

Allows you to view the available commands, as well as the available options within
a command.

AVAILABLE-POWER

Configures the available power value.

DEFAULT-
PORT-CONSUMPTION

Configures the default power consumption value for each connected port.

ENABLE

Enables power sourcing equipment.

LIST

Lists the interface options configuration.

NO

Sets the default of a particular option.

PORT

Configures each port individually.

TRACE

Enables tracing.

Teldat SA

1 Configuration

PoE Power over Ethernet

3

 


background image

EXIT

Returns to the

ethernetx/y config>

configuration prompt.

1.5.1 ? (HELP)

Use the (HELP) command to list all the commands that are available at the router configuration level. It can also be
used after a specific command to list the available options.

Syntax:

ethernet0/0 PSE config>?

Example:

ethernet0/0 PSE config>?

available-power

Sets the amount of power available in milliWatts

default-port-consumption

Sets the default power consumption of the POE
devices connected to the switch in milliwatts

enable

Enables Power Sourcing Equipment

list

Display Power Sourcing Equipment configuration

no

Negate a command or set its defaults

port

Port configuration

trace

Enable tracing

exit

ethernet0/0 PSE config>

1.5.2 AVAILABLE-POWER

This command allows you to set a deliverable power limit for all devices powered by the switch. Default is 120000.

The indicated value is in milliwatts.

Use the NO command to restore the default value.

For the equipment to function correctly, the value configured in this parameter must always be equal to (or lower
than) the actual value of the source connected to the router.

Syntax:

ethernet0/0 PSE config>available-power ?

<120000..245000>

milliWatts

Example:

ethernet0/0 PSE config>available-power 140000

1.5.3 DEFAULT-PORT-CONSUMPTION

Allows you to set the computed consumption value for each device connected to the switch.

The value is 0 by default, corresponding to the NO value.

The indicated value is in milliwatts.

The following strategy is used when calculating the power delivered to the devices:

• If a value has been configured for this parameter, it will be used as the consumption value for each connected

device.

By programming this parameter, you do not need to be overly restrictive with the devices that show high consump-
tion levels during detection (automatically assigned to the default class when incapable of implementing class detec-
tion) but end up not consuming as much.

Note

Programmers are responsible for assigning values that match the actual parameters of the devices to
be connected.

• If a value has not been configured, the consumption value for each device will correspond to the value configured

for the port (when in forced power mode) or to the value of the class detected for this device. In this case, the
power is:

1 Configuration

Teldat SA

4

PoE Power over Ethernet

 


background image

Class

Implementation

Minimum Delivered Power
(PSE)

Maximum power consumed in
the device (PD)

0

By default

15.4 W

0.44 a 12.95 W

1

Optional

4.0 W

0.44 a 3.84 W

2

Optional

7.0 W

3.84 a 6.49 W

3

Optional

15.4 W

6.49 a 12.95 W

4

Reserved for Future Use

Treated as Class 0

15.4 W

Reserved for future use.

5

Reserved for Future Use

Treated as Class 0

15.4 W

Reserved for future use.

Syntax:

ethernet0/0 PSE config>default-port-consumption ?

<4500..15400>

milliWatts

Example:

ethernet0/0 PSE config> default-port-consumption 7500

1.5.4 ENABLE

This allows the device to operate as power sourcing equipment. The default value is disabled, so you will need to
specify this command to enable PSE.

Syntax:

ethernet0/0 PSE config>enable

Example:

ethernet0/0 PSE config>enable

1.5.5 LIST

This displays the current configuration for the interface’s configurable parameters.

Example:

ethernet0/0 PSE config>list

Power Sourcing Equipment .......... Enabled
Available Power ................... 140000 mW
Default Power Line Consumption ....

4500 mW

ethernet0/0 PSE config>

1.5.6 NO

This allows you to establish the default values for the options.

Example:

ethernet0/0 PSE config>no ?

available-power

Sets the amount of power available in milliWatts

default-port-consumption

Sets the default power consumption of the POE
devices connected to the switch in milliwatts

enable

Enables Power Sourcing Equipment

port

Port configuration

trace

Enable tracing

ethernet0/0 PSE config>

Teldat SA

1 Configuration

PoE Power over Ethernet

5

 


background image

1.5.7 PORT

Allows you to activate the forced power mode functionality on each port. This way, and unless a short circuit is detec-
ted, ports always receive power supply.

You should also configure the maximum power allocated to the connected device.

This command also allows you to permanently power off a port.

The port is configured in normal power mode by default.

Syntax:

ethernet0/0 PSE config>port <port number> <mode> <power assigned>
<port number>

<1..16>

Port number

all

All ports

<mode>

disable

Power off

force-power

Force power

<power assigned>

<4500..15400>

milliWatts

To configure port 3 in forced power mode and assign it 7600mw.

Example 1:

ethernet0/0 PSE config>port 3 force-power 7600

To configure all ports in forced power mode and assign 7600mw to each port.

Example 2:

ethernet0/0 PSE config>port all force-power 7000

To disable the forced power configuration on port 3.

Example 3:

ethernet0/0 PSE config>no port 3 force-power

To disable the forced power configuration on all ports.

Example 4:

ethernet0/0 PSE config>no port all force-power

History:

Release

Modification

11.00.06

11.01.01

The

disable

option was introduced.

1.5.8 TRACE

Use this command to selectively enable debugging traces. Traces are generated as ETH.055 events.

Syntax:

ethernet0/0 PSE config>trace {all | <subsystem>}

Example:

ethernet0/0 PSE config>trace all

History:

Release

Modification

11.00.04

11.01.00

This command was introduced.

1 Configuration

Teldat SA

6

PoE Power over Ethernet

 


background image

1.5.9 EXIT

Use the EXIT command to exit the PSE configuration menu and to return to the main Ethernet

ethernet0/0 config>

interface configuration menu.

Syntax:

ethernet0/0 PSE config>exit

Example:

ethernet0/0 PSE config>exit
ethernet0/0 config>

Teldat SA

1 Configuration

PoE Power over Ethernet

7

 


background image

Chapter 2 Monitoring

2.1 Monitoring

This chapter describes the power sourcing equipment (PSE) monitoring commands and is divided into the following
sections:

• Viewing the PSE monitoring prompt.

• PSE monitoring commands.

2.2 Viewing the PSE monitoring prompt

Follow these steps to access the monitoring environment:

(1)

At the GESTCON (*) prompt, enter PROCESS 3 (or P 3) or MONITOR.

(2)

At the monitoring prompt (+), enter NETWORK <interface_name> (interface_name is the name of the Ether-
net interface on which the PSE functionality can be used).

(3)

To monitor the POE functionalities, simply use the commands described in this chapter. To access this menu,
enter the POWER-SOURCING-EQUIPMENT command once inside the interface monitoring environment.

*monitor
Console Operator
+net ethernet0/0

--

Ethernet Console

--

ethernet0/0 ETH+?

bitrate
collision
llc
power-sourcing-equipment
repeater
status
exit

ethernet0/0 ETH+power-sourcing-equipment
-- Power Sourcing Equipment Monitoring Console --
ethernet0/0 PSE+

2.3 Monitoring PSE

This section describes the PSE monitoring commands.

Command

Function

? (HELP)

Allows you to view the available commands or the options available within a com-
mand.

DISABLE-PORT

Disconnects a connected port.

ENABLE-PORT

Reconnects a disabled port.

LIST-STATUS

Displays the status of the ports.

MODE-PORT

Sets port operating mode.

REGISTERS

Displays device registers.

RESTART-PSE

Restarts the PSE control.

EXIT

Returns to the

ethernetx/y ETH+

monitoring prompt.

2.3.1 ? (HELP)

Use the (HELP) command to list all the commands that are available at the router configuration level. It can also be
used after a specific command to list the available options.

Syntax:

ethernet0/0 PSE+?

2 Monitoring

Teldat SA

8

PoE Power over Ethernet

 


background image

Example:

ethernet0/0 PSE+?

disable-port

Disconnect a connected port

enable-port

Reconnect a disabled port

list-status

Display ports status

mode-port

Set port operating mode

restart-pse

Restart PSE control

exit

ethernet0/0 PSE+

2.3.2 DISABLE-PORT

Disconnects (i.e. stops providing power to a previously connected port).

Syntax:

ethernet0/0 PSE+disable-port <port number>

Example:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 7000 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Open Circuit
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+disable-port 6
Port 6 disabled
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 0 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Open Circuit
Port 6: [Adm. disabled] Disabled
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

2.3.3 ENABLE-PORT

Reconnects (i.e. supplies power to a previously disconnected port).

Syntax:

ethernet0/0 PSE+enable-port <port number>

Example:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 0 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Open Circuit
Port 6: [Adm. disabled] Disabled
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+enable-port 6
Port 6 enabled
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)

Teldat SA

2 Monitoring

PoE Power over Ethernet

9

 


background image

Available PSE output power = 120000 mW
Minimum PSE output power

= 7000 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Open Circuit
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

2.3.4 LIST-STATUS

Displays the status of the PSE.

Syntax:

ethernet0/0 PSE+list-status

Example 1:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 7000 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Open Circuit
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

Example 2:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
PSE device disabled
Available PSE output power = 120000 mW
Minimum PSE output power

= 0 mW

POE output power per port

= As requested

Ports Status

Port 5: Disabled
Port 6: Disabled
Port 7: Disabled
Port 8: Disabled

ethernet0/0 PSE+

The fields have the following meanings:

POE cards:

Displays the POE cards detected and their ports.

Note

The “POE cards” field is only available for those devices that can detect the card without power.

Available PSE output power

Corresponds to the value configured through the available-power command.

Minimum PSE output power

Minimum delivered power, calculated in accordance with the devices detected and their requirements.

POE output power per port

Power calculated per port. This corresponds to the value programmed through the default-power-consumption com-
mand. If the value is different to 0, then each connected port is calculated with the programmed value. However if it
is 0, the calculated power will be that assigned to the detected class.

2 Monitoring

Teldat SA

10

PoE Power over Ethernet

 


background image

Ports Status

Status of each port. The list of available states is as follows:

Port Status

Adm. auto

The port mode has been set as

auto

with the

mode-port auto

monitoring com-

mand.

Adm. disabled

The port has been disabled with the

disable-port

monitoring command. This com-

mand overrides the current configuration.

Adm. force <n> mW

The port mode has been forced to deliver the specified power. This has been en-
abled with the

mode-port force-power

monitoring command.

Detect Unknown

The port is in

auto

mode. Detection has not completed.

Detect Short Circuit

The port is in

auto

mode. A short circuit was detected during the detection pro-

cess.

Detect Signature Resistance
Low

The port is in

auto

mode. The detection process has revealed that the resistance

presented by the device is below that specified in the IEEE.802.3af norm (below
15K).

Detect Signature Resistance
High

The port is in

auto

mode. The detection process has revealed that the resistance

presented by the device is above that specified in the IEEE.802.3af norm (above
33K).

Detect Good

The port is in

auto

mode. The device class has been correctly detected as shown.

Detect Open Circuit

The port is in

auto

mode. No device has been detected.

Disabled

The port is disabled and will not deliver power.

Power forced, applied <n> mW

Power is unconditionally applied to the port as shown, except when a short circuit
is detected.

Unavailable

The port cannot be managed because the device is unavailable. This can happen
when there is no power.

The list of detected classes is as follows:

Class

0

Power delivered by default: 15400 mW.
Default class for devices that do not implement detection.

1

“Low Power PD” devices

Power delivered by default: 4000 mW.

2

“Medium Power PD” devices

Power delivered by default: 7000 mW.

3

“High or Full Power PD” devices

Power delivered by default: 15400 mW.

4

Reserved. Power is delivered as for class 0.

5

Reserved. Power is delivered as for class 0.

2.3.5 MODE-PORT

Changes the operating mode of the ports.

Syntax:

ethernet0/0 PSE+mode-port <port number> <mode> <assigned power>
<port number>

<5..8>

Value in the specified range

all

All ports

<mode>

auto

auto mode

default

set default mode

force-power

force power

<power assigned>

<4500..15400>

milliWatts

Teldat SA

2 Monitoring

PoE Power over Ethernet

11

 


background image

Example 1:

To change the operating mode of port 5 to power forced mode and assign it 7600mw:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 7600 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Signature Resistance Low
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+mode-port 5 force-power 7600
Port 5 new mode: force power, with 7600 milliwatts assigned
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 15200 mW

POE output power per port

= As requested

Ports Status

Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

Example 2:

To change the operating mode of port 6 to automatic mode:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 15200 mW

POE output power per port

= As requested

Ports Status

Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+mode-port 6 auto
Port 6 new mode: auto
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 14600 mW

POE output power per port

= As requested

Ports Status

Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: [Adm. auto] Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

History:

Release

Modification

11.00.06

11.01.01

The

default

option was introduced.

2.3.6 REGISTERS

Displays the internal registers of the device.

Syntax:

2 Monitoring

Teldat SA

12

PoE Power over Ethernet

 


background image

ethernet0/0 PSE+registers

Example:

ethernet0/0 PSE+registers
Registers for device 0 (ports 5-8)

0 ... 00 f1 00 -- 00 -- 00 --
8 ... 00 -- 00 -- 00 00 00 00

10 ... 00 34 00 00 00 00 00 a0
Interrupt: not pending

Registers for device 1 (no ports)

0 ... 00 f1 00 -- 00 -- 00 --
8 ... 00 -- 00 -- 00 00 00 00

10 ... 00 30 00 00 00 00 00 a0
Interrupt: not pending

ethernet0/0 PSE+

2.3.7 RESTART-PSE

Restarts the PSE control. All ports are powered off and all devices are restarted.

Syntax:

ethernet0/0 PSE+restart-pse

Example:

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 7000 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Signature Resistance Low
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+restart-pse
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 0 mW

POE output power per port

= As requested

Ports Status

Port 5: Disabled
Port 6: Disabled
Port 7: Disabled
Port 8: Disabled

ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power

= 7000 mW

POE output power per port

= As requested

Ports Status

Port 5: Detect Signature Resistance Low
Port 6: Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit

ethernet0/0 PSE+

2.3.8 EXIT

Use the EXIT command to exit the power sourcing equipment monitoring menu and to return to the main Ethernet

ethernet0/0 ETH+

interface monitoring menu.

Teldat SA

2 Monitoring

PoE Power over Ethernet

13

 


background image

Syntax:

ethernet0/0 PSE+exit

Example:

ethernet0/0 PSE+exit
ethernet0/0 ETH+

2 Monitoring

Teldat SA

14

PoE Power over Ethernet