background image

TBC1-1VDSL1SFP card

Installation Manual

Copyright© Teldat-Dm 630-I Version 2.4 Teldat S.A.

Teldat S.A.

Manual

TBC1-1VDSL1SFP card

1

 


background image

Legal Notice

Warranty

This publication is subject to change.

Teldat S.A. offers no warranty whatsoever for information contained in this manual.

Teldat S.A. is not liable for any direct, indirect, collateral, consequential or any other damage connected to the deliv-
ery, supply or use of this manual.

Manual

Teldat S.A.

2

TBC1-1VDSL1SFP card

 


background image

Table of Contents

Chapter 1

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1.1

Supported Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.2

Warning and notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.3

Who should read this manual? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.4

What is in this manual? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.5

How is the information organized? . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.6

Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1.7

Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Chapter 2

TBC1-1VDSL1SFP Expansion Card. . . . . . . . . . . . . . . . . . . . . . . . 3

2.1

TBC1-1VDSL1SFP expansion card: Characteristics . . . . . . . . . . . . . . . . . . . . .

3

2.2

TBC1-1VDSL1SFP expansion card: Connectors . . . . . . . . . . . . . . . . . . . . . .

4

Chapter 3

Installing the TBC1-1VDSL1SFP expansion card. . . . . . . . . . . . . . . . . 6

3.1

Requirements prior to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

3.1.1

Determining the firmware file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

3.2

Installing or replacing the TBC1-1VDSL1SFP expansion card. . . . . . . . . . . . . . . . .

6

Chapter 4

LEDs and connector pinouts: Description . . . . . . . . . . . . . . . . . . . . . 7

4.1

TBC1-1VDSL1SFP expansion card: LEDs . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.2

Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.2.1

RJ-11 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.2.2

SFP Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Chapter 5

Regulatory compliance and safety information . . . . . . . . . . . . . . . . . . 9

5.1

Manufacturer Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

5.2

Translated Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

5.3

WEEE Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

5.4

REACH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

5.5

EC Declaration of Conformity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

5.6

CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Teldat S.A.

Table of Contents

TBC1-1VDSL1SFP card

i

 


background image

Table of Contents

Teldat S.A.

ii

TBC1-1VDSL1SFP card

 


background image

Chapter 1 About This Manual

This installation guide contains step by step instructions on how to correctly install, uninstall and replace the
TBC1-1VDSL1SFP expansion card in Teldat M/iM routers.

1.1 Supported Devices

The information provided in this installation manual only applies to the TBC1-1VDSL1SFP card.

1.2 Warning and notes

Observe the warnings and instructions given in this manual to avoid and prevent injuries or damage during installa-
tion and maintenance. Please follow the security procedures and guidelines when working near electrical equipment.
The warnings and notes are provided in each chapter as appropriate.

1.3 Who should read this manual?

This manual should be read by installers and network administrators who need to install, configure or maintain net-
works. This guide assumes that the installer is familiar with network electronics and technologies.

1.4 What is in this manual?

This installation guide contains the following information:

• A description of the general characteristics of the TBC1-1VDSL1SFP expan-

sion card.

• A description of the steps to carry out in order to install the TBC1-1VDSL1SFP

card in Teldat M/iM routers.

• A description of the TBC1-1VDSL1SFP expansion card LEDs and connector

pinouts.

1.5 How is the information organized?

This document aims to provide all the information necessary to install the TBC1-1VDSL1SFP expansion card in
Teldat M/iM routers.

• TBC1-1VDSL1SFP expansion card characteristics.

• TBC1-1VDSL1SFP expansion card connectors.

• Requirements prior to installation.

• Installing the TBC1-1VDSL1SFP expansion card.

1.6 Technical Support

Teldat S.A. offers a technical support service. Device software can be upgraded on a regular basis for maintenance
purposes and for new features.

Contact information:

Web: http://www.teldat.com

Tel.: +34 918 076 565

Fax: +34 918 076 566

Teldat S.A.

1 About This Manual

TBC1-1VDSL1SFP card

1

 


background image

Email: support@teldat.com

1.7 Related Documentation

Teldat Dm569-I

Teldat M1 Installation.

Teldat- Dm741-I

ADSL-VDSL

Note

The manufacturer reserves the right to make changes and improvements to the appropriate features in
both the software and hardware of this product, modifying the specifications of this manual without prior
notice.

The images showing the front and back panels of the device are for information purposes only. Some
small modifications may exist in the actual device.

1 About This Manual

Teldat S.A.

2

TBC1-1VDSL1SFP card

 


background image

Chapter 2 TBC1-1VDSL1SFP Expansion Card

This manual focuses on the TBC1-1VDSL1SFP expansion card.

The SFP (

Small Form-Factor Pluggable

) interface provides connectivity to a single

Gigabit Ethernet

device or to a

network, allowing clients to use different SFPs for special requirements such as distance, cost, existing infrastructure
or future expansions.

VDSL2 stands for Very high bit rate Digital Subscriber Line version 2, which is defined in theITU G.993.2 standard.

VDSL2 has evolved from the ADSL/ADSL2/ADSL2+ technologies and the main differences areas follows:

• Upstream and downstream channel multiplicity.

• Supports up to 200 Mbps, symmetric (profile 30a).

• It only uses FDM mode, EC mode is not defined (echo cancellation or carrier

overlapping).

• Allows for a new encapsulation to be used: PTM.

• Multiple link diagnostics.

For further information on ADSL and VDSL technologies, please see the Teldat-

Dm741-I ADSL-VDSL

manual.

Fig. 1:

TBC1-1VDSL1SFP card

2.1 TBC1-1VDSL1SFP expansion card: Characteristics

The main characteristics of the TBC1-1VDSL1SFP expansion card are as follows:
TBC1-1VDSL1SFP card: SFP characteristics

Ports

1 SFP Gigabit Ethernet port.

Standards

IEEE

• 802.1Q (VLAN).

• 1000-Base-X.

Types

• LX/LH (single-mode 1310 nm).

• SX (multi-mode 850 nm).

• ZX (single-mode 1550 nm).

Speed

1000 Mbps full duplex.

TBC1-1VDSL1SFP card: xDSL Characteristics

Ports

One RJ-11 VDSL/ADSL port

ADSL

Standards

ANSI:

Teldat S.A.

2 TBC1-1VDSL1SFP Expansion Card

TBC1-1VDSL1SFP card

3

 


background image

• T1.413 Issue 2.

ITU-T G.991.1 (G.DMT):

• Annex A: Full Rate ADSL over POTS.

ITU-T G.991.2 (G. Lite) Lite ADSL over POTS.

G.992.3 (ADSL2):

• Annex A: ADSL2 over POTS.

• Annex L: RE-ADSL2 over POTS.

• Annex M: ADSL2 with extended upstream over POTS.

G.992.5 (ADSL2+):

• Annex A: ADSL2+ over POTS.

• Annex M: ADSL2+ with extended upstream over POTS.

Downstream Speed

27 Mbps.

Upstream Speed

3 Mbps.

Transfer Mode

ATM (

Asynchronous Transfer Mode

).

Other characteristics

Dying Gasp:

• ITU G.991.2 standard recommendation.

VDSL

Standards

ITU-T G.993.2 (Annex A and B):

• Profiles: 8a, 8b, 8c, 8d, 12a, 12b, 17a

Downstream Speed

Up to 100 Mbps.

Upstream Speed

Up to 50 Mbps.

Transfer Mode

PTM (

Packet Transfer Mode

).

Other characteristics

PTM Transmission Convergence (PTM-TC):

• G.993.2 Annex K.

Dual-Latency supported.

Dying Gasp:

• ITU G.991.2 standard recommendation.

2.2 TBC1-1VDSL1SFP expansion card: Connectors

Figure 2 shows the front board of the TBC1-1VDSL1SFP card:

Fig. 2:

Front of the TBC1-1VDSL1SFP card

2 TBC1-1VDSL1SFP Expansion Card

Teldat S.A.

4

TBC1-1VDSL1SFP card

 


background image

The front board elements are as follows:
Elements table for the front of the TBC1-1VDSL1SFP card

Item

Description

A

SFP port.

B

xDSL port.

C

Activity SFP LED.

D

Link SFP LED.

E

Status xDSL LED.

Teldat S.A.

2 TBC1-1VDSL1SFP Expansion Card

TBC1-1VDSL1SFP card

5

 


background image

Chapter 3 Installing the TBC1-1VDSL1SFP expansion card

This chapter provides information on how to install and uninstall the TBC1-1VDSL1SFP expansion card in Teldat M/
iM routers.

This information includes:

• Requirements prior to installation.

• Installing or replacing a TBC1-1VDSL1SFP expansion card.

3.1 Requirements prior to installation

To configure the card, you must be able to access the Teldat M/iM router through a console or a Telnet connection.
For further information, please see the

Connecting for configuration

section under the

Teldat-Dm569-I Teldat M1 In-

stallation

manual.

For the TBC1-1VDSL1SFP expansion cards to operate properly, you need to load the appropriate firmware file for
each card into the router.

If the firmware has not been loaded in the device prior to installing the card, you'll still be able to find out what firm-
ware file you need.

3.1.1 Determining the firmware file

There are two options to determine the firmware file needed for the installed xDSL card:

3.1.1.1 FTP quote site listfirmwares command

The FTP command quote site listfirmwares returns a list containing the names of the firmware files needed for the
device to operate properly:

ftp> quote site listfirmwares
211 fw000013.bfw
ftp>

3.1.1.2 FTP system firmwares-required monitoring command

The system firmwares-required monitoring command displays the same information as the previous command, but
in the local console:

+system firmwares-required
List of required firmwares for detected hardware
------------------------------------------------
Filename

Description

Version/Subv

------------- ---------------------------- ---------------
fw000013.bfw

Broadcom 63268 TSS-mode

v3.1

+

Once the necessary firmware file has been detected, load it into the device through an FTP connection.

For further information on how to load firmware files in the router, please see the Teldat-Dm 748-I

Software Updating

manual.

3.2 Installing or replacing the TBC1-1VDSL1SFP expansion card.

To install or replace a TBC1-1VDSL1SFP card, please see the

Expansion Slot

section under the

Teldat-Dm569-I

Teldat M1 Installation

manual.

3 Installing the TBC1-1VDSL1SFP expansion card

Teldat S.A.

6

TBC1-1VDSL1SFP card

 


background image

Chapter 4 LEDs and connector pinouts: Description

This chapter provides information on the TBC1-1VDSL1SFP expansion card LEDs and connector pinouts.

4.1 TBC1-1VDSL1SFP expansion card: LEDs

The TBC1-1VDSL1SFP expansion card has three LEDs: ACT, LINK and STATUS.

Fig. 3:

TBC1-1VDSL1SFP card : LEDs

.

LEDs table of the TBC1-1VDSL1SFP card

Item

State

C

Blue => Lights up when there is activity.

D

Yellow => Lights up when the link is established.

E

Slow blinking => looking for connection.

Rapid blinking => negotiation.

Steady => connected.

4.2 Connector Pinouts

The TBC1-1VDSL1SFP expansion card has one RJ-11 connector and one SFP connector.

4.2.1 RJ-11 Connector

The following figure shows the RJ-11 connector pinouts:

Fig. 4:

RJ-11 connector pinouts

The following table display the information associated to each connector pinout:
TBC1-1VDSL1SFP card RJ-11 Connector Pinouts

RJ-11 pinouts

Signal

1

--

2

--

3

TIP

4

RING

Teldat S.A.

4 LEDs and connector pinouts: Description

TBC1-1VDSL1SFP card

7

 


background image

5

--

6

--

We recommend you use a 26 AWG cable, at the very least. This may be supplied with the card itself or, be described
in the safety instructions.

Warning

To reduce the risk of fire, only use a 26 AWG cable or a cable with a larger diameter.

4.2.2 SFP Connector

Warning

SFP modules to be installed in the card socket should be class 1 devices that comply with standard
IEC-60825-1.

4 LEDs and connector pinouts: Description

Teldat S.A.

8

TBC1-1VDSL1SFP card

 


background image

Chapter 5 Regulatory compliance and safety information

5.1 Manufacturer Information

Brand

Teldat

Manufacturer

Teldat S.A.

Country

Spain

Postal Address

Isacc Newton, 10

Parque Tecnológico de Madrid, 28760

Tres Cantos, Madid, Spain

International Phone

+34 91 807 65 65

Teldat S.A.

5 Regulatory compliance and safety information

TBC1-1VDSL1SFP card

9

 


background image

5.2 Translated Safety Warnings

                    

   !   "  #  $  "    %      & '

()*+, -./0/)1 2/-3 4*-56789.9./: /-5*610;<)9 )*613* 37+961   /6/ 37+961
+*61>9?* @/789)27

          A          B 

C  D  E $   $ F G   H   I =
 F    JK

GL               M F ' 
 NOP=QRS=M

T   G L U    '   F V  ''   M
 U   PON=QRS=M

W*@;6/ GL  4 -6*)9 372), @*6X., +,)1 ;-)2*<-)478/ 367--7 M -**)49)-)4;YZ/8/
-)7.@72); NOP=QRS=M

GL =[    H     H=M=\ 
]   NOP^O_ QRS=M`QQa 

T A  GL  "         b c  'F 
 M       NOP=QRS=M

5.3 WEEE Information

The waste container symbol with the >X< indicates that the device must be dis-
posed of separately from normal domestic waste at an appropriate waste disposal
facility at the end of its useful service life.

Das auf dem Gerät befindliche Symbol mit dem durchgekreuzten
Müllcontainerbedeutet, dass das Gerät am Ende der Nutzungsdauer bei den
hierfür vorgesehenenEntsorgungsstellen getrennt vom normalen Hausmüll zu
entsorgen ist.

El símbolo del contenedor con la cruz, que se encuentra en el aparato, significa
que cuando el equipo haya llegado al final de su vida útil, deberá ser llevado a los
centros de recogida previstos, y que su tratamiento debe estar separado del de
los residuos urbanos.

5 Regulatory compliance and safety information

Teldat S.A.

10

TBC1-1VDSL1SFP card

 


background image

5.4 REACH

In compliance with the REACH Candidate List, the delivered product and product packaging do not contain chemical
substances above a concentration limit of 0.1% weight by weight (w/w). This declaration will be updated whenever
any changes occur or other chemical substances are added to the REACH Candidate List. Information is currently
provided to consumers upon request.

5.5 EC Declaration of Conformity

English (EN)

This equipment is in compliance with the essential requirements and other relev-
ant provisions of:

Directive 2014/30/EU (EMC)

Directive 2014/35/EU (LVD)

Directive 2011/65/EU (RoHS)

of the European Parliament

Spanish (ES) Español

Este dispositivo cumple con los requisitos esenciales y con las normas correspon-
dientes de las siguientes directivas:

Directiva 2014/30/UE (EMC)

Directiva 2014/35/UE (LVD)

Directiva 2011/65/UE (RoHS)

del Parlamento Europeo

German (DE) Deutsch

Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren
entsprechenden Vorgaben der

Richtlinie 2014/30/UE (EMC)

Richtlinie 2014/35/UE (LVD)

Richtlinie 2011/65/UE (RoHS)

des Europäischen Parlaments.

Note

Directive 2014/30/EU (EMC) replaces Directive 2004/108/EC (EMC) on 20th April 2016

Directive 2014/35/EU (LVD) replaces Directive 2006/95/EC (LVD) on 20th April 2016

The EC declaration of conformity and additional product documentation can be accessed here: http://www.teldat.com

5.6 CE Marking

This equipment is in conformity with the CE procedures and marking.

Teldat S.A.

5 Regulatory compliance and safety information

TBC1-1VDSL1SFP card

11