Read this

fi

rst

Product documentation

Covered products

The following Tektronix products are covered by this document:

WFM7200 Waveform Monitor

WVR7200 Waveform Rasterizer

Product documentation

version

Your instrument was shipped with

fi

rmware version 3.4.X installed, which is

newer than the

fi

rmware version described by the product documentation that was

shipped with your instrument. This document provides a brief description of the
new features being introduced with

fi

rmware version 3.4.X.

You can download the latest versions of the documentation for your product at
the Tektronix Web site (www.tek.com).

New features in

fi

rmware version 3.4.X

Firmware version 3.4.X introduces a new HDR (High Dynamic Range) tool set
for assisting camera operators and editors to adjust their content to the correct
levels. The new HDR features and functions are described on the following pages.

NOTE.

Option PROD is required to access HDR features.

www.tek.com
Copyright © Tektronix

*P071340702*

071-3407-02

 


background image

Read this

fi

rst

Waveform display

Dynamic Range setting.

The pop-up menu for the Waveform display now contains

a selection for setting the Dynamic Range as shown below.

NOTE.

When HDR or HDR Full is selected, you can use the Left / Right

arrow keys to toggle the vertical scale of the graticule between NITS, STOPS,
REFLECTANCE and CODE VALUE. The selected scale is shown at the bottom
of the display. (See Figure 5.)

Figure 1: Waveform display pop-up menu showing the Dynamic Range selection

2

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

The following settings are available:

SDR (Standard Dynamic Range)

. Use this setting for conventional SD,

HD and 3G signals using ITU-R BT.709/2020 with OETF (Optical to
Electrical Transfer Function) gamma of 0.45 and with a display gamma EOTF
(Electrical to Optical Transfer Function) of 2.4 as de

fi

ned in ITU-R BT.1886.

When SDR is selected as the dynamic range, the CONFIG > Graticules and
Readouts menu contains the following graticule settings:

STD

. The Standard graticule is available in either millivolts (Normal) or

Percent and can be con

fi

gured within CONFIG > Graticules and Readouts

> SDI Waveform Graticules.

NARROW

. The Narrow graticule uses a NITs graticule scale and code

values, which is the traditional signal representation. This setting provides
a signal representation using a code value of 64 decimal (10-bit) equal to
0 mV or 0%, and a code value of 940 decimal (10-bit) equal to 700 mV
or 100%.

FULL

. The Full graticule uses a NITs graticule scale and code values that

provides signal representation with a code value of 4d decimal (10-bit)
equal to 0%, and a code value of 1019 decimal (10-bit) equal to 100%.

NOTE.

In SDI signals, the code words 0-3d and 1020-1023 are excluded and

clipped from a

fi

le that uses 0-1023 as the full range as de

fi

ned in ITU-R

BT2100.

HDR (High Dynamic Range)

. Use this setting if you need the bit depth to

more ef

fi

ciently produce smoother blacks and brighter specular highlights.

When HDR is selected as the dynamic range, the CONFIG > Graticules and
Readouts menu contains the following graticule settings:

HLG(1200)

. The Hybrid Log Gamma (HLG) graticule is de

fi

ned in

standard ARIB STD B-67 and was developed by the BBC and NHK.
SMPTE standard ST 2084 de

fi

nes High Dynamic Range Electro-Optical

Transfer Function of Mastering Reference Displays also know as
Perceptual Quantization (PQ).

ST2084(1K)

. This graticule uses the ST 2084 curve with a maximum

value of 1000 Nits using the narrow range.

ST2084(2K)

. This graticule uses the ST 2084 curve with a maximum

value of 2000 Nits using narrow range.

ST2084(4K)

. This graticule uses the ST 2084 curve with a maximum

value of 4000 Nits using narrow range.

Read This First for

fi

rmware version 3.4.X

3

 


background image

Read this

fi

rst

ST2084(5K)

. This graticule uses the ST 2084 curve with a maximum

value of 5000 Nits using narrow range.

ST2084(10K)

. This graticule uses the ST 2084 curve with a maximum

value of 10000 Nits using narrow range.

NOTE.

Narrow range is de

fi

ned by ITU-R BT.2100 as signal representation

with code value 64 decimal (10-bit) equal to 0 mV or 0%, and code value 940
decimal (10-bit) equal to 700 mV or 100%.

HDR Full (High Dynamic Range Full)

. Use this setting if you need the

High Dynamic Full Range de

fi

ned by ITU-R BT.2100, which provides signal

representation with code value 4d decimal (10-bit) equal to 0%, and code
value 1019 decimal (10-bit) equal to 100%.

NOTE.

In SDI signals, the code words 0-3d and 1020-1023 are excluded and

clipped from a

fi

le that uses 0-1023 as the full range as de

fi

ned in ITU-R BT2100.

When HDR Full is selected as the dynamic range, the CONFIG > Graticules
and Readouts menu contains the following graticule settings:

ST2084(1K) Full

. This graticule uses the ST 2084 curve with a maximum

value of 1000 Nits using full range.

ST2084(10K) Full

. This graticule uses the ST 2084 curve with a

maximum value of 10000 Nits using full range.

Camera Log

. Use this setting to use a graticule with a curve based on the

camera manufacturers speci

fi

cation. When Camera Log is selected as the

dynamic range, the CONFIG > Graticules and Readouts menu contains the
following graticule settings:

S Log

. This graticule uses the Sony S Log curve.

S Log2

. This graticule uses the Sony S Log2 curve.

S Log3

. This graticule uses the Sony S Log3 curve.

C Log

. This graticule uses the Canon C Log curve.

Log C

. This graticule uses the ARRI Log C curve at (ISO) El 800.

BT.709

. This graticule uses the traditional ITU-R BT.709 representation.

4

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

HDR graticule selection.

The CONFIG > Graticules and Readouts menu now

contains a setting for selecting the HDR graticule to be used by the Waveform
display: HLG(1200), ST2084 (1K), ST2084 (2K), ST2084 (5K), or ST2084
(10K).

Figure 2: CONFIG menu showing the SDI HDR Waveform graticule selection

Read This First for

fi

rmware version 3.4.X

5

 


background image

Read this

fi

rst

HDR graticule vertical scale setting.

When an HDR graticule is selected for the

Waveform display, you can use the Left / Right arrow keys to toggle the vertical
scale units between NITS, STOPS, or REFLECTANCE. Camera operators can
use the graticule lines at 2%, 18% or 90% Re

fl

ectance to properly setup camera

exposure with a camera test chart of 2% black, 18% gray and 90% white.

Figure 3: Waveform display showing the HDR graticule with NITS selected as the vertical scale

Gain adjustment.

When the ST.2084 (1K) or ST.2084 (10K) HDR graticules are

selected, a

fi

xed zoom mode from 100 Nits to maximum scale is available by

using the Up arrow key to enable Zoom Mode and the Down arrow key to disable
Zoom Mode. When Zoom Mode is enabled, the Gain function and the Vertical
Position controls are locked in a

fi

xed con

fi

guration. When in HDR modes,

Variable Gain will be enabled by default to facilitate the Zoom mode function.

Voltage cursors.

When HDR or HDR Full mode is selected as the Dynamic

Range setting, the mV voltage measurement cursors are replaced by a set of Nits
measurement cursors.

6

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

Picture display brightup

settings

The CONFIG > Display Settings > Picture Brightup on Luma Gamut Error menu
has new selections for HDR monitoring.

Off

. For this setting, the highlight overlay is turned off in the picture display.

Luma

. For this setting, the highlight overlay is turned on for Luma values

that exceed signal levels based on gamut thresholds for luma settings.

HDR Specular On

. For this setting, the highlight overlay is turned on for

selected HDR settings and produces HDR zebra highlights in the picture for
large areas of the trace that exceed 100 nits.

NOTE.

The HDR zebra highlighting allows users to verify the location and the

size of the specular highlights.

HDR Specular Full On

. For this setting, the highlight overlay is turned on

for HDR Full settings and produces HDR zebra highlights in the picture for
large areas of the trace that exceeding 100 nits.

Figure 4: CONFIG menu showing the Picture Brightup on Luma/Specular Gamut Error selection

Read This First for

fi

rmware version 3.4.X

7

 


background image

Read this

fi

rst

Typical HDR

monitoring setup for

ST.2084 (1K or 10K)

The following

fi

gure shows a typical HDR monitoring setup for

ST.2084 (1K or 10K):

Tile 1: Waveform display with HDR graticule.

Tile 2: Waveform display with the HDR zoom mode enabled.

Tile 3: Picture display with specular highlighting enabled.

Tile 4: Video Session display.

Figure 5: Typical HDR monitoring setup for ST.2084 (1K or 10K)

8

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

New features in

fi

rmware version 3.3.X

Firmware version 3.3.X introduces the new features and functions described on
the following pages.

Datalist display

ANC Data highlighting.

The following new ANC Data highlighting has been

added to the Datalist display (See Figure 6.):

Blue background highlighting indicates Ancillary Data

Cyan highlighting in an ANC Data packet indicates the checksum data

White text in an ANC Data packet indicates the packet header data

Green text in an ANC Data packet indicates user-de

fi

ned data words

Red text in an ANC Data packet indicates a data word error

Figure 6: Datalist display showing ANC Data packet highlighting

Read This First for

fi

rmware version 3.4.X

9

 


background image

Read this

fi

rst

Switch line highlighting.

New gold highlighting indicates a switch line. (See

Figure 7.)

Figure 7: Datalist display with switch line highlighting

Sample value readout.

In full-screen mode, a new readout near the top right of the

Datalist display (See Figure 6.) provides a description of the selected sample. The
readout value depends on the type of the selected sample:

SAV/EAV Header: Values 0, 1, 2 (3FF, 000, 000)

SAV/EAV XYZ: F (Field: 0 = Field 1, 1 = Field 2) V (Vertical: 0 = Not
Blanking, 1 = Field Blanking) H (Horizontal: 0 = SAV, 1 = EAV)

ANC Data Header: Values 1, 2, 3 (000, 3FF, 3FF)

ANC Data (DID) Data Identi

fi

er

ANC Data (SDID/DBN) Secondary Data Identi

fi

er / Data Block Number

ANC Data (DC) Data Count

ANC Data (UDW[x]) User Data Word Number

ANC Data (CS) Checksum

Sample value shown in millivolts and (%) (See Figure 7.)

10

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

Audio Loudness

Session reset using the

GPI interface

There is a new Loudness Session Logging setting in the CONFIG > Utilities >
Ground Closure Mode menu that allows you to con

fi

gure the GPI interface

(REMOTE connector) to reset the Audio Loudness Session and to note the reset
in the Loudness Trigger Log.

When a selected pin on the REMOTE connector is grounded (See Table 1.),
the Audio Loudness Session will save the values of the loudness measurement
parameters in the Loudness Trigger Log. The loudness meter will then be reset
and begin a new measurement when the GPI trigger is released.

Use the Tektronix WFM Remote Interface to view the Loudness Trigger Log.

Trigger events.

There are three trigger events that can be used to reset the Audio

Loudness Session:

Start Commercial 1:

Use this GPI trigger to reset the Audio Loudness

Session when a commercial program is provided and to indicate the
commercial program in the Loudness Trigger Log.

Start Program 1:

Use this GPI trigger to reset the Audio Loudness Session

when a main program is provided and to indicate the main program in the
Loudness Trigger Log.

Pause Monitoring Channel 1:

Use this GPI trigger to reset the Audio

Loudness Session when monitoring is paused and to indicate the pause in
the Loudness Trigger Log.

Use only the Channel 1 trigger events when the CONFIG > Input Mode is
con

fi

gured to Single mode. When the CONFIG > Input Mode is con

fi

gured to

Simultaneous, you can also use the Channel 2 trigger events to reset the Audio
Loudness Session for the secondary channel.

Read This First for

fi

rmware version 3.4.X

11

 


background image

Read this

fi

rst

REMOTE connector pin functions.

The following table shows the functions of the

REMOTE connector pins when the Ground Closure Mode is set to Loudness
Session Logging.

Table 1: REMOTE connector pin functions in Loudness Session Logging mode

REMOTE connector pin

Function

1

GND (In)

2

Reserved (I/O)

3

Reserved (I/O)

4

Reserved (In)

5

Reserved (In)

6

GND (In)

7

Time Code Positive (LTC In)

8

Time Code Negative (LTC In)

9

Ground Closure (Alarm Out)

10

Start Commercial Monitoring Channel 1

11

Start Program Monitoring Channel 1

12

Pause Monitoring Channel 1

13

Start Commercial Monitoring Channel 2

14

Start Program Monitoring Channel 2

15

Pause Monitoring Channel 2

12

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

ITU-R BT.2020 color space

There is a new ITU-R BT.2020 setting in the CONFIG > SDI Input > HD
Colorimetry menu that allows you to monitor the BT.2020 color space for HD
formats. When the HD Colorimetry is set to ITU 2020, the targets on the Vector
and Lightning displays shift slightly to conform to the BT.2020 color space and
the gamut measurement limits also change.

If the colorspace is set to AUTO, the instrument will select BT.2020 if signalled
in the VPID.

HD colorimetry readout

The Video Session display has a new readout to indicate the current HD
colorimetry setting (CONFIG > SDI Input > HD Colorimetry).

Figure 8: New colorimetry readout on the Video Session display

Read This First for

fi

rmware version 3.4.X

13

 


background image

Read this

fi

rst

Audio level readouts

The audio levels for each of the audio channels (1–8) are now shown on the Audio
Session display and the Audio Auxiliary Loudness display.

Figure 9: New audio level readouts on the Audio Session display

Figure 10: New audio level readouts on the Audio Auxiliary Loudness display

14

Read This First for

fi

rmware version 3.4.X

 


background image

Read this

fi

rst

Additional SDI format

support

The following table lists the additional SDI formats that are supported in

fi

rmware

version 3.3.X. Included are deep color formats for 3G-SDI Level A/B and 48p
frame rate support for HD formats.

Table 2: New SDI formats supported in

fi

rmware version 3.3.X

Link

Format

Sample
structure

Bits

Frame/

fi

eld rates

HD-SDI

2048×1080

4:2:2

YCbCr

10b

23.98/24/25/29.97/30p and psF

2048×1080

4:2:2

YCbCr

10b

47.95/48/50/59.94/60p

2048×1080

4:4:4

YCbCr

10b

23.98/24/25/29.97/30p and psF

2048×1080

4:4:4

GBR

10b

23.98/24/25/29.97/30p and psF

2048×1080

4:4:4

YCbCr

12b

23.98/24/25/29.97/30p and psF

Dual Link HD-SDI

2048×1080

4:2:2

YCbCr

12b

23.98/24/25/29.97/30p and psF

2048×1080

4:2:2

YCbCr

10b

47.95/48/50/59.94/60p

1920×1080

4:4:4

GBR

10b

50/59.94/60i, 23.98/24/25/29.97/30p and psF

2048×1080

4:4:4

GBR

10b

23.98/24/25/29.97/30p and psF

1920×1080

4:4:4

GBR

12b

50/59.94/60i, 23.98/24/25/29.97/30p

2048×1080

4:4:4

GBR

12b

23.98/24/25/29.97/30p and psF

3G-SDI Level A
(Option 3G)

2048×1080

4:4:4

XYZ

12b

24/25/30p and psF

2048×1080

4:2:2

YCbCr

10b

47.95/48/50/59.94/60p

2048×1080

4:4:4

YCbCr

10b

23.98/24/25/29.97/30p and psF

2048×1080

4:4:4

GBR

10b

23.98/24/25/29.97/30p and psF

2048×1080

4:4:4

YCbCr

12b

23.98/24/25/29.97/30p and psF

3G-SDI Level B
(Option 3G)

2048×1080

4:2:2

YCbCr

12b

23.98/24/25/29.97/30p and psF

Read This First for

fi

rmware version 3.4.X

15