PA4000 Series Power Analyzers

Declassi

fi

cation and Security

ZZZ

Instructions

xx

www.tektronix.com

*P077105200*

077-1052-00

 


background image

Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries
or suppliers, and are protected by national copyright laws and international treaty provisions.

Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Speci

fi

cations and price change privileges reserved.

TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

TekSecure is a trademark of Tektronix, Inc.

Contacting Tektronix

Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA

For product information, sales, service, and technical support:

In North America, call 1-800-833-9200.
Worldwide, visit

www.tektronix.com

to

fi

nd contacts in your area.

 


background image

Table of Contents

Preface ..............................................................................................................

iii

Clear and Sanitize Procedures.....................................................................................

1

Memory Devices...............................................................................................

2

Secure User Memory ..........................................................................................

3

Data Export Devices...........................................................................................

5

PA4000 Declassi

fi

cation/Security Instructions

i

 


background image

Table of Contents

ii

PA4000 Declassi

fi

cation/Security Instructions

 


background image

Preface

If you have data security concerns, this document helps you to sanitize or remove
memory devices from the Tektronix PA4000 Power Analyzer.

The PA4000 Power Analyzer has data storage (memory) devices and data output
devices (USB ports, RS232, GPIB connector (optional), and LAN Ethernet
connector). These instructions explain how to clear or sanitize the memory
devices.

If you have any questions, contact the Tektronix Technical Support Center at
www.tektronix.com/support.

Products

The following Tektronix products are covered by this document:

PA4000 (1, 2, 3 or 4 channels).

Related Documents

The

Tektronix PA4000 Power Analyzer User Manual

, part number 077-0815-xx,

is available on the Tektronix Web site at www.tektronix.com/manuals.

PA4000 Declassi

fi

cation/Security Instructions

iii

 


background image

Preface

Terms

The following terms may be used in this document:

Clear.

This removes data on media/memory before reusing it in a secured

area. All reusable memory is cleared to deny access to previously stored
information by standard means of access.

Erase.

This is equivalent to clear.

Instrument Declassi

fi

cation.

A term that refers to procedures that must be

undertaken before an instrument can be removed from a secure environment.
Declassi

fi

cation procedures include memory sanitization and memory

removal, and sometimes both.

Media storage/data export device.

Any of several devices that can be used

to store or export data from the instrument, such as a USB port.

Nonvolatile memory.

Data is retained when the instrument is powered off.

Power off.

Some instruments have a “Standby” mode, in which power is

still supplied to the instrument. For the purpose of clearing data, putting the
instrument in Standby mode does not qualify as powering off. For these
products, you will need to either push a rear-panel OFF switch or remove the
power source from the instrument.

Remove.

This is a physical means to clear the data by removing the memory

device from the instrument. Instructions are available in the product Service
Manual.

Sanitize.

This eradicates the data from media/memory so that the data cannot

be recovered by other means or technology. This is typically used when the
device will be moved (temporarily or permanently) from a secured area to a
non-secured area.

Scrub.

The user is able to directly retrieve the memory device contents.

User-modi

fi

able.

The user can write to the memory device during normal

instrument operation, using the instrument interface or remote control.

Volatile memory.

Data is lost when the instrument is powered off.

iv

PA4000 Declassi

fi

cation/Security Instructions

 


background image

Clear and Sanitize Procedures

The following terms are used in the tables in this section:

Type of User Info Stored

This column describes the type of user information that is stored in the device:

User data.

Waveforms and other measurement data that represent signals

that users connect to the instrument.

User settings.

Instrument settings that the user can change.

Both.

Both user data and user settings are stored in the device.

None.

Neither user data nor user settings are stored in the device.

Method of Modi

fi

cation

This column indicates the method of modifying data:

Direct.

The user can modify the data.

Indirect.

The instrument system resources modify the data. The user cannot

modify the data.

User Accessible

This column indicates whether the user can retrieve the device contents:

Yes.

The user can directly retrieve the memory device contents.

No.

The user cannot retrieve the memory device contents.

To Clear

This column tells how to clear data from the media or memory device before
reusing it in a secured area. All reusable memory is cleared to deny access to
previously stored information by standard means of access.

To Sanitize

This column tells how to eradicate the data from the media or memory device so
that the data cannot be recovered by other means or technology. This is typically
used when the device will be moved (temporarily or permanently) from a secured
area to a non-secured area.

PA4000 Declassi

fi

cation/Security Instructions

1

 


background image

Clear and Sanitize Procedures

Memory Devices

The following tables list the volatile and nonvolatile memory devices in the
standard instrument and listed options. Detailed procedures to clear or sanitize
these devices, if any, are shown following each table.

Table 1: Volatile memory devices for the PA4000

Type and minimum
size

Function

Type of
user info
stored

Backed
up by
battery

Method
of
modi

fi

cationData input method

Location

User
accessible

To clear

Internal SRAM
(34 kBytes)

Main DSP
system memory

User
settings

No

Indirectly

Firmware

CPU Card,
U3

No

Remove power
from the
instrument for at
least 20 seconds.

DRAM (2 Mbytes)

Display memory

Data on
display

No

Indirectly

Firmware

CPU Card,
U24

No

Remove power
from the
instrument for at
least 20 seconds.

SRAM (1 MBytes)

Main DSP
system memory

User
settings

No

Indirectly

Firmware

CPU Card,
U2

No

Remove power
from the
instrument for at
least 20 seconds.

Internal SRAM
(512 kBytes) x 4

Analog
measurement
system program

Measurement
results

No

Indirectly

Firmware

CPU Card
U28, U30,
U32 and
U34

No

Remove power
from the
instrument for at
least 20 seconds.

Ethernet controller
Internal 3808 Bytes

Ethernet
controller
variables

Results
transfer

No

Indirectly

Firmware

Ethernet /
USB card,
U4

No

Remove power
from the
instrument for at
least 20 seconds.

USB client controller
(4 kBytes)

USB client
variables

Results
transfer

No

Indirectly

Firmware

Ethernet /
USB card,
U3

No

Remove power
from the
instrument for at
least 20 seconds.

2

PA4000 Declassi

fi

cation/Security Instructions

 


background image

Clear and Sanitize Procedures

Table 2: Nonvolatile memory devices

Type and
minimum size

Function

Type
of user
info
stored

Method of
modi

fi

cation

Data input
method

Location

User
accessible

To clear

To sanitize

EEPROM,
128 kBytes

Calibration
constants

None

Indirect via

fi

rmware

Factory
con

fi

guration

Analog
module, U1

No

Not applicable, does
not contain user
data or settings.
Clearing would
disable instrument
functionality.

Not applicable,
does not contain
user data or
settings. Sanitizing
would disable
instrument
functionality.

EEPROM,
(128 kBytes)

User
con

fi

guration

storage

User
con

fi

g.

storage

Indirect via

fi

rmware

User changing the
con

fi

guration of

the product

CPU Card, U8

No

See instructions
below.

Not applicable.
Sanitizing would
disable instrument
functionality.

CPU internal

fl

ash

(512 kBytes)

Stores
operating
code

None

Indirect via

fi

rmware

Firmware upgrade
program

CPU Card, U3

No

Not applicable, does
not contain user
data or settings.
Clearing would
disable instrument
functionality.

Not applicable.
Sanitizing would
disable instrument
functionality.

CPU external

fl

ash

(1 Mbyte)

Stores
operating
code

None

Indirect via

fi

rmware

Firmware upgrade
program

CPU Card, U4

No

Not applicable, does
not contain user
data or settings.
Clearing would
disable instrument
functionality.

Not applicable.
Sanitizing would
disable instrument
functionality.

USB client
processor
(64 kBytes)

Stores
operating
code

None

None

Factory
programming

USB /

No

Not applicable, does
not contain user
data or settings.
Clearing would
disable instrument
functionality.

Not applicable.
Sanitizing would
disable instrument
functionality.

Ethernet controller
(128 kBytes)

Stores
operating
code

None

None

Factory
programming

CPU card

No

Not applicable, does
not contain user
data or settings.
Clearing would
disable instrument
functionality.

Not applicable.
Sanitizing would
disable instrument
functionality.

Secure User Memory

To secure the non-volatile memory, follow the

Secure

procedure below. In any

case, no measurement results are stored. Only instrument setup and calibration
may be are stored in memory inside the PA4000.

Secure

To erase con

fi

dential data from your PA4000 power analyzer, perform the

following procedure. This procedure does not erase or change factory calibration
constants.

The following user settings need to be cleared as separate actions:

PA4000 Declassi

fi

cation/Security Instructions

3

 


background image

Clear and Sanitize Procedures

Current con

fi

guration

User con

fi

gurations 1 though 8

User Communications Settings (these are not reset by loading the default
con

fi

guration)

To reset the current con

fi

guration (used at power on).

1.

Press the front panel

MENU

button.

2.

Scroll down to

User Con

fi

guration

.

3.

Select

Load Default Con

fi

guration

.

4.

Wait for con

fi

rmation that the con

fi

guration has been loaded.

To reset con

fi

gurations 1 through 8 to default.

1.

First load the default con

fi

guration as detailed above.

2.

Select

Con

fi

guration 1

(the

fi

rst con

fi

guration below

Save To USB

option).

3.

Scroll down to

Save Current Con

fi

guration

and select this option (bottom

soft key).

4.

When

fi

nished, select

OK

.

5.

If the name of the con

fi

guration is not “Con

fi

guration 1”, then rename the

con

fi

guration.

6.

Repeat steps 2 through 5 for con

fi

gurations 2 through 8.

To clear the communication settings.

1.

Press the front panel

MENU

button.

2.

Scroll down to

Interfaces

.

3.

In the RS232 menu, set the baud rate to the factory default of

38400

.

4.

In the GPIB menu set the address to the factory default of

5

.

5.

In the Ethernet IP Selection Method menu, select the factory default of

Set

IP using DHCP

.

6.

In the Ethernet Static IP Setting menu, set the IP address to

192.168.2.255

,

the Subnet mask to

255.255.255.0

and the Default Gateway to

192.168.2.1

(factory defaults).

4

PA4000 Declassi

fi

cation/Security Instructions

 


background image

Clear and Sanitize Procedures

Data Export Devices

The following table lists the data export devices. Detailed procedures to disable
these devices, if any, are shown in the table.

Table 3: Data export devices

Type

Function

Method of
modi

fi

cation

Data input
method

Location

User
accessible

To disable

USB host port
(supports removable
USB

fl

ash drive)

User storage
of results and
instrument setup

directly

User writeable

USB host port on front of
instrument
Files can be deleted or
over-written on the PC, or
USB

fl

ash drive can be removed

and destroyed.

The USB host port
cannot be disabled.

USB device port

Supports remote
control and data
transfer to a PC.

directly

Remote control
via USBTMC

USB device port on rear of
instrument

The USB client device
port cannot be disabled.

LAN Ethernet
connector

Supports remote
control and data
transfer to a PC

directly

Remote control

Rear panel.

The Ethernet LAN
controller cannot be
disabled.

GPIB connector

Supports remote
control and data
transfer to a PC

directly

Remote control

Rear panel (optional)

The GPIB interface
cannot be disabled.

RS232 connector

Supports remote
control and data
transfer to a PC

directly

Remote control

Rear panel

The RS232 interface
cannot be disabled.

PA4000 Declassi

fi

cation/Security Instructions

5