Full Text Searchable PDF User Manual

Mixed Signal Oscilloscopes
MSO2000 Series, DPO2000 Series Data Sheet
Features & Bene
fi
ts
Key Performance Speci
fi
cations
200, 100 MHz Bandwidth Models
2 and 4 Analog Channel Models
16 Digital Channels (MSO Series)
1 GS/s Sample Rate on All Channels
1 Megapoint Record Length on All Channels
5,000 wfm/s Maximum Waveform Capture Rate
Suite of Advanced Triggers
Ease of Use Features
Wave Inspector
®
Controls Provide Easy Navigation and Automated
Search of Waveform Data
FilterVu™ Variable Low-pass Filter Allows for Removal of Unwanted
Signal Noise while still Capturing High-frequency Events
29 Automated Measurements, and FFT Analysis for Simpli
fi
ed
Waveform Analysis
TekVPI
®
Probe Interface Supports Active, Differential, and Current
Probes for Automatic Scaling and Units
7 in. (180 mm) Widescreen TFT-LCD Color Display
Small Footprint and Lightweight – Only 5.3 in. (134 mm) deep and 7 lb.
14 oz. (3.6 kg)
Connectivity
USB 2.0 Host Port on the Front Panel for Quick and Easy Data Storage
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge
®
-compatible Printer
Optional 10/100 Ethernet Port for Network Connection and Video Out
Port to Export the Oscilloscope Display to a Monitor or Projector
Optional Serial Triggering and Analysis
Automated Serial Triggering, Decode, and Search Options for I
2
C, SPI,
CAN, LIN, and RS-232/422/485/UART
Mixed Signal Design and Analysis (MSO Series)
Automated Triggering, Decode, and Search on Parallel Buses
Multichannel Setup and Hold Triggering
Feature-rich Tools for Debugging Mixed
Signal Designs
Offering up to 200 MHz bandwidth and 1 GS/s sample rate, the
MSO/DPO2000 Mixed Signal Oscilloscope Series delivers advanced debug
features at an entry-level price. With up to 20 channels for analyzing analog
and digital signals, you can quickly
fi
nd and diagnose problems in complex
designs. To capture long windows of signal activity while maintaining
fi
ne timing resolution, the MSO/DPO2000 offers a deep record length of
1 Mpoints standard on all channels.
With Wave Inspector
®
controls for rapid waveform navigation and
automated serial and parallel bus analysis, the MSO/DPO2000
Oscilloscope Series from Tektronix provides the feature-rich tools you need
to simplify and speed debug of your complex design.

Data Sheet
Discover – A waveform capture rate of 5,000 wfm/s maximizes the probability of capturing
elusive glitches and other infrequent events.
Comprehensive Features Speed Every Stage
of Debug
The MSO/DPO2000 Series offers a robust set of features to speed every
stage of debugging your design – from quickly discovering an anomaly and
capturing it, to searching your waveform record for the event and analyzing
its characteristics and your device’s behavior.
Discover
To debug a design problem,
fi
rst you must know it exists. Every
design engineer spends time looking for problems in their design, a
time-consuming and frustrating task without the right debug tools.
The MSO/DPO2000 Series offers complete visualization of signals,
providing fast insight into the real operation of your device. A waveform
capture rate of 5,000 waveforms per second enables you to see glitches
and other infrequent transients quickly, revealing the true nature of device
faults. A digital phosphor display with intensity grading shows the history
of a signal’s activity by intensifying areas of the signal that occur more
frequently, providing a visual display of just how often anomalies occur.
Capture – Triggering on a speci
fi
c transmit data packet going across an RS-232 bus. A
complete set of triggers, including triggers for speci
fi
c serial packet content, ensures you
quickly capture your event of interest.
Capture
Discovering a device fault is only the
fi
rst step. Next, you must capture the
event of interest to identify root cause.
The MSO/DPO2000 Series provides a complete set of triggers – including
runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel
data – to help quickly
fi
nd your event. With up to a 1 Mpoint record length,
you can capture many events of interest, even thousands of serial packets,
in a single acquisition for further analysis while maintaining high resolution
to zoom in on
fi
ne signal details.
From triggering on speci
fi
c packet content to automatic decode in
multiple data formats, the MSO/DPO2000 Series provides integrated
support for a broad range of serial buses – I
2
C, SPI, CAN, LIN, and
RS-232/422/485/UART. The ability to decode up to two serial and/or parallel
buses simultaneously means you gain insight into system-level problems
quickly.
To further help troubleshoot system-level interactions in complex embedded
systems, the MSO2000 Series offers 16 digital channels in addition to
its analog channels. Since the digital channels are fully integrated into
the oscilloscope, you can trigger across all input channels, automatically
time-correlating all analog, digital, and serial signals.
2
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Search – I
2
C decode showing results from a Wave Inspector search for Address value
50. Wave Inspector controls provide unprecedented ef
fi
ciency in viewing and navigating
waveform data.
Search
Finding your event of interest in a long waveform record can be time
consuming without the right search tools. With today’s record lengths
pushing to a million data points, locating your event can mean scrolling
through thousands of screens of signal activity.
The MSO/DPO2000 Series offers the industry’s most comprehensive
search and waveform navigation with its innovative Wave Inspector
®
controls. These controls speed panning and zooming through your record.
With a unique force-feedback system, you can move from one end of your
record to the other in just seconds. User marks allow you to mark any
location that you may want to reference later for further investigation. Or,
automatically search your record for criteria you de
fi
ne. Wave Inspector
will instantly search your entire record, including analog, digital, and serial
bus data. Along the way it will automatically mark every occurrence of your
de
fi
ned event so you can quickly move between events.
Analyze – FFT analysis of a pulsed signal. A comprehensive set of integrated analysis
tools speeds veri
fi
cation of your design’s performance.
Analyze
Verifying that your prototype’s performance matches simulations and meets
the project’s design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widths to sophisticated power
loss analysis and investigation of noise sources.
The MSO/DPO2000 Series offers a comprehensive set of integrated
analysis tools including waveform- and screen-based cursors, 29
automated measurements, and FFT analysis. Specialized application
support for serial bus analysis is also available.
For extended analysis, National Instrument’s LabVIEW SignalExpress™
Tektronix Edition provides over 200 built-in functions including time and
frequency domain analysis, limit testing, data logging, and customizable
reports.
www.tektronix.com
3

Data Sheet
Wave Inspector controls provide unprecedented ef
fi
ciency in viewing, navigating, and
analyzing waveform data. Zip through your 1 Mpoint record by turning the outer pan
control (1). Get from the beginning to end in seconds. See something of interest and want
to see more details? Just turn the inner zoom control (2).
Wave Inspector
®
Navigation and Search
A 1 Mpoint record length represents thousands of screens of information.
The MSO/DPO2000 Series enables you to
fi
nd your event in seconds with
Wave Inspector, the industry’s best tool for navigation and search.
Wave Inspector offers the following innovative controls:
Zoom/Pan
A dedicated, two-tier front-panel control provides intuitive control of both
zooming and panning. The inner control adjusts the zoom factor (or zoom
scale); turning it clockwise activates zoom and goes to progressively higher
zoom factors, while turning it counterclockwise results in lower zoom factors
and eventually turning zoom off. No longer do you need to navigate through
multiple menus to adjust your zoom view. The outer control pans the zoom
box across the waveform to quickly get to the portion of waveform you are
interested in. The outer control also utilizes force-feedback to determine
how fast to pan on the waveform. The farther you turn the outer control, the
faster the zoom box moves. Pan direction is changed by simply turning the
control the other way.
Play/Pause
A dedicated
Play/Pause
front-panel button scrolls the waveform across the
display automatically while you look for anomalies or an event of interest.
Playback speed and direction are controlled using the intuitive pan control.
Once again, turning the control further makes the waveform scroll faster and
changing direction is as simple as turning the control the other way.
Search step 1: You de
fi
ne what you would like to
fi
nd.
Search step 2: Wave Inspector automatically searches through the record and marks each
event with a hollow white triangle. You can then use the
Previous
and
Next
buttons to
jump from one event to the next.
User Marks
Press the
Set Mark
front-panel button to place one or more marks on
the waveform. Navigating between marks is as simple as pressing the
Previous
(
←
) and
Next
(
→
) buttons on the front panel.
Search Marks
The
Search
button allows you to automatically search through your long
acquisition looking for user-de
fi
ned events. All occurrences of the event
are highlighted with search marks and are easily navigated to, using the
front-panel
Previous
(
←
) and
Next
(
→
) buttons. Search types include
edge, pulse width/glitch, runt, logic, setup and hold, rise/fall time parallel
bus, and I
2
C, SPI, CAN, LIN, and RS-232/422/485/UART packet content.
4
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Digital phosphor technology enables a 5,000 wfm/s waveform capture rate and real-time
intensity grading on the MSO/DPO2000 Series.
The MSO Series provides 16 integrated digital channels enabling you to view and analyze
time-correlated analog and digital signals.
Digital Phosphor Technology
The MSO/DPO2000 Series’ digital phosphor technology provides you with
fast insight into the real operation of your device. Its waveform capture rate
of 5,000 wfm/s gives you a high probability of quickly seeing the infrequent
problems common in digital systems: runt pulses, glitches, timing issues,
and more.
Waveforms are superimposed with one another and waveform points that
occur more frequently are intensi
fi
ed. This quickly highlights the events
With the color-coded digital waveform display, groups are created by simply placing digital
channels together on the screen, allowing the digital channels to be moved as a group.
You can set threshold values for each pod of eight channels, enabling support for up to
two different logic families.
that over time occur more often or, in the case of infrequent anomalies,
occur less often.
With the MSO/DPO2000 Series, you can choose in
fi
nite persistence
or variable persistence, determining how long the previous waveform
acquisitions stay on-screen. This allows you to determine how often an
anomaly is occurring.
Mixed Signal Design and Analysis
(MSO Series)
The MSO2000 Series Mixed Signal Oscilloscopes provide 16 digital
channels. These channels are tightly integrated into the oscilloscope's user
interface, simplifying operation and making it possible to solve mixed-signal
issues easily.
Color-coded Digital Waveform Display
The MSO2000 Series has rede
fi
ned the way you view digital waveforms.
One common problem shared by both logic analyzers and mixed-signal
oscilloscopes is determining if data is a one or a zero when zoomed in far
enough that the digital trace stays
fl
at all the way across the display. The
MSO2000 Series has color-coded digital traces, displaying ones in green
and zeros in blue.
www.tektronix.com
5

Data Sheet
White edges indicate additional information is available by acquiring at a higher sample
rate.
The P6316 MSO probe offers two eight-channel pods to simplify connecting to your
device.
The multiple transition detection hardware of the MSO2000 Series will
show you a white edge on the display when the system detects multiple
transitions. This acts as a visual reminder that increasing the sample rate
on the next acquisition will reveal higher frequency information than your
previous settings could acquire.
The MSO2000 Series simpli
fi
es channel setup by allowing you to group
digital waveforms and enter waveform labels by using a USB keyboard.
By simply placing digital waveforms next to each other, they form a group.
Once a group is formed, you can position all the channels contained in that
group collectively. This greatly reduces the normal setup time associated
with positioning channels individually.
P6316 MSO Probe
This unique probe design offers two eight-channel pods, simplifying the
process of connecting to the device-under-test. When connecting to square
pins, the P6316 can connect directly to 8×2 square pin headers spaced
on tenth-inch centers. When more attachment
fl
exibility is required, you
can use the included
fl
ying lead sets and grabbers to clip onto surface
mount devices or test points. The P6316 offers outstanding electrical
characteristics applying only 8 pF of capacitive loading with 101 k
Ω
input
impedance.
Output of DAC Signal – Notice how FilterVu™ clearly shows the noise-free steps of the
DAC in the foreground trace (yellow) which has removed all frequencies above 5.5 kHz.
FilterVu also captures and displays high-frequency glitches up to the full bandwidth of the
oscilloscope in the background trace (orange).
FilterVu™ Variable Low-pass Filter
Tired of being limited to a 20 MHz bandwidth
fi
lter in your oscilloscope?
Simply turn on FilterVu and adjust the variable low-pass noise
fi
lter. Unlike
other variable low-pass
fi
lters, FilterVu
fi
lters out the unwanted noise from
your signal while still capturing glitches and other signal details up to the full
bandwidth of the oscilloscope. It does this by showing two waveforms: a
waveform that can be
fi
ltered (foreground waveform) and a glitch capture
waveform (background waveform).
The
fi
ltered waveform uses a variable low-pass
fi
lter to block out noise,
yielding a cleaner waveform to more precisely locate signal edges
and amplitude levels. The result is improved con
fi
dence in you cursor
measurements and cleaner documentation of important signal attributes.
When the noise
fi
lter is adjusted to the lowest available noise-cutoff
frequency, no more than 1% of high-frequency content that could cause the
oscilloscope to alias will pass through the
fi
lter.
The glitch capture waveform shows signal details up to the full bandwidth of
the oscilloscope. The oscilloscope captures pulses as narrow as 5 ns, using
peak-detect min/max sampling, protecting you from missing unexpected
glitches or other high-frequency events.
FilterVu is ideal for repetitive, nonrepetitive, and single-shot events.
6
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Triggering on a speci
fi
c data packet going across an I
2
C bus. The yellow waveform is
clock and the blue waveform is data. A bus waveform provides decoded packet content
including Start, Address, Read/Write, Data, and Stop.
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest dif
fi
cult. The
MSO/DPO2000 Series offers a robust set of tools for debugging serial
buses with automatic trigger, decode, and search for I
2
C, SPI, CAN, LIN,
and RS-232/422/485/UART.
Serial Triggering
Trigger on packet content such as start of packet, speci
fi
c addresses,
speci
fi
c data content, unique identi
fi
ers, etc. on popular serial interfaces
such as I
2
C, SPI, CAN, LIN, and RS-232/422/485/UART.
Bus Display
Provides a higher-level, combined view of the individual signals (clock, data,
chip enable, etc.) that make up your bus, making it easy to identify where
packets begin and end and identifying subpacket components such as
address, data, identi
fi
er, CRC, etc.
Bus Decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope do it for you! Once you’ve set up a bus, the
Event table showing decoded Identi
fi
er, DLC, DATA, and CRC for every CAN packet in
a long acquisition.
MSO/DPO2000 Series will decode each packet on the bus, and display the
value in hex, binary, decimal (LIN only), or ASCII (RS-232/422/485/UART
only) in the bus waveform.
Event Table
In addition to seeing decoded packet data on the bus waveform itself, you
can view all captured packets in a tabular view much like you would see in
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.).
Search
Serial triggering is very useful for isolating the event of interest, but once
you’ve captured it and need to analyze the surrounding data, what do
you do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. With
the MSO/DPO2000 Series, you can have the oscilloscope automatically
search through the acquired data for user-de
fi
ned criteria including serial
packet content. Each occurrence is highlighted by a search mark. Rapid
navigation between marks is as simple as pressing the
Previous
(
←
) and
Next
(
→
) buttons on the front panel.
www.tektronix.com
7

Data Sheet
The MSO/DPO2000 is designed to make your work easier. The bright, widescreen display
shows a long time window. Dedicated front-panel controls simplify operation. A USB host
port on the front panel allows you to easily transfer screenshots, instrument settings, and
waveform data to a memory stick.
Designed to Make Your Work Easier
Bright, Widescreen Display
The MSO/DPO2000 Series features a 7 inch (180 mm) widescreen,
TFT-LCD display for seeing intricate signal details.
Dedicated Front-panel Controls
Per-channel vertical controls provide simple and intuitive operation. No
longer do you need to share one set of vertical controls across all four
channels.
Connectivity
A USB host port on the front panel enables easy transfer of screenshots,
instrument settings, and waveform data to a USB thumb drive. The rear
panel contains a USB device port for controlling the oscilloscope remotely
from a PC or for connecting a USB keyboard. The USB device port can also
be used to print directly to a PictBridge
®
-compatible printer. An optional
10/100 Ethernet port enables easy connection to networks and an optional
Video Out port allows the oscilloscope display to be exported to an external
monitor or projector.
Compact Form Factor
A compact, portable form factor allows the MSO/DPO2000 Series to be
easily moved between labs and, with a depth of just 5.3 inches (134 mm),
it saves you valuable space on your test bench.
The MSO/DPO2000 Series’ compact form factor frees up valuable space on your bench or
desktop.
TekVPI probe interface simpli
fi
es connecting your probes to the oscilloscope.
TekVPI
®
Probe Interface
The TekVPI probe interface sets the standard for ease of use in probing.
TekVPI probes feature status indicators and controls, as well as a probe
menu button right on the comp box itself. This button brings up a probe
menu on the oscilloscope display with all relevant settings and controls for
the probe. TekVPI probes can be controlled remotely through USB, GPIB,
or Ethernet, enabling more versatile solutions in ATE environments.
8
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
NI LabVIEW SignalExpress™ Tektronix Edition is a fully interactive measurement
acquisition and analysis software developed jointly with National Instruments and
optimized for the MSO/DPO Series.
Extended Analysis
Acquiring data and measurements from the MSO/DPO2000 Series is as
simple as connecting a USB cable from the oscilloscope to your PC. Key
software applications – NI LabVIEW SignalExpress™ Tektronix Edition
LE, OpenChoice
®
Desktop, and Microsoft Excel and Word toolbars – are
included standard with each oscilloscope to enable fast and easy direct
communication with your Windows PC.
OpenChoice
®
Desktop software enables seamless connection between the oscilloscope
and your PC.
NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly
acquire, generate, analyze, compare, import, and save measurement data
and signals using an intuitive drag-and-drop user interface that does not
require any programming. The optional Professional Version offers over
200 built-in functions that provide additional signal processing, advanced
analysis, sweeping, limit testing, and user-de
fi
ned step capabilities.
For simple tasks, the included OpenChoice Desktop enables fast and easy
communication between the oscilloscope and your PC through USB, GPIB,
or LAN for transferring settings, waveforms, and screen images.
www.tektronix.com
9

Data Sheet
Characteristics
Vertical System Analog Channels
Characteristic
MSO2012
DPO2012
MSO2014
DPO2014
MSO2024
DPO2024
Input Channels
2
4
4
Analog Bandwidth (-3 dB)*
1
100 MHz
100 MHz
200 MHz
Calculated Rise Time
3.5 ns
3.5 ns
2.1 ns
Hardware Bandwidth Limits
20 MHz
Input Coupling
AC, DC, GND
Input Impedance
1 M
Ω
±2%, 11.5 pF ±2 pF
Input Sensitivity Range
2 mV/div to 5 V/div
Vertical Resolution
8 bits
Maximum Input Voltage, 1 M
Ω
300 V
RMS
with peaks
≤
±450 V
DC Gain Accuracy (with offset set to 0 V)
±3% for 10 mV/div to 5 V/div
±4% for 2 mV/div to 5 mV/div
Channel-to-Channel Isolation
(Any Two Channels at Equal Vertical Scale)
≥
100:1 at
≤
100 MHz
100:1 at
≤
200 MHz
*
1
Bandwidth is 20 MHz at 2 mV/div, all models.
Offset Range
Range
1 M
Ω
2 mV/div to 200 mV/div
±1 V
>200 mV/div to 5 V/div
±25 V
Vertical System Digital Channels
Characteristic
All MSO2000 Models
Input Channels
16 Digital (D15 to D0)
Thresholds
Threshold per set of 8 channels
Threshold Selections
TTL, CMOS, ECL, PECL, User De
fi
ned
User-de
fi
ned Threshold
Range
±20 V
Maximum Input Voltage
±40 V
Threshold Accuracy
±(100 mV +3% of threshold setting)
Maximum Input Dynamic
Range
80 V
pk-pk
(threshold setting dependent)
Minimum Voltage Swing
500 mV
pk-pk
Input Impedance
101 k
Ω
Probe Loading
8 pF
Vertical Resolution
1 bit
Horizontal System Analog Channels
Characteristic
MSO2012/2014
DPO2012/2014
MSO2024
DPO2024
Maximum Sample Rate
(all channels)
1 GS/s
Maximum Record Length
(all channels)
1 Mpoints
Maximum Duration of
Time Captured at Highest
Sample Rate
(all channels)
1 ms
Time-base Range (s/div)
4 ns to 100 s
2 ns to 100 s
Time-base Delay Time
Range
-10 divisions to 5000 s
Channel-to-Channel
Deskew Range
±100 ns
Time-base Accuracy
±25 ppm
Horizontal System Digital Channels
Characteristic
All MSO2000 Models
Maximum Sample Rate
(when using any of
channels D7-D0)
1 GS/s (1 ns resolution)
Maximum Sample Rate
(when using any of
channels D15-D8)
500 MS/s (2 ns resolution)
Maximum Record Length
(all channels)
1 Mpoints
Minimum Detectable
Pulse Width
5 ns
Channel-to-Channel
Skew
2 ns typical
10
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Trigger System
Characteristic
Description
Main Trigger Modes
Auto, Normal, and Single
Trigger Coupling
DC, HF reject (attenuates >85 kHz), LF reject
(attenuates <65 kHz), noise reject (reduces
sensitivity)
Trigger Holdoff
Range
20 ns to 8 s
Trigger Signal
Frequency Counter
Provides a higher accuracy means of identifying
the frequency of trigger signals. Trigger Signal
Frequency counter resolution is 6 digits.
Trigger Sensitivity
Characteristic
Description
Internal DC Coupled
0.4 divisions from DC to 50 MHz
0.6 divisions > 50 MHz to 100 MHz
0.8 divisions > 100 MHz to 200 MHz
External
(Auxiliary Input)
200 mV from DC to 100 MHz, 1X attenuation
Trigger Level Range
Characteristic
Description
Any Channel
±4.92 divisions from center of screen
External
(Auxiliary Input)
±6.25 V, 1X attenuation
±12.5 V, 10X attenuation
Trigger Modes
Mode
Description
Edge
Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject.
Pulse Width
Trigger on width of positive or negative pulses that are >, <, =, or
≠
a speci
fi
ed period of time.
Runt
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the
fi
rst again.
Logic
Trigger when any logical pattern of channels goes false or stays true for speci
fi
ed period of time. Any input can be used as a clock to look for the
pattern on a clock edge. Pattern (AND, OR, NAND, NOR) speci
fi
ed for all analog and digital input channels de
fi
ned as High, Low, or Don’t Care.
Setup and Hold
Trigger on violations of both setup time and hold time between clock and data present on any of the input channels.
Rise/Fall Time
Trigger on pulse edge rates that are faster or slower than speci
fi
ed. Slope may be positive, negative, or either.
Video
Trigger on line number, all lines, odd, even, or all
fi
elds on NTSC, PAL, and SECAM video signals.
I
2
C (optional)
Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I
2
C buses up to 3.4 Mb/s.
SPI (optional)
Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses up to 10.0 Mb/s.
CAN (optional)
Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identi
fi
er (standard or extended), Data, Identi
fi
er and Data, End of
Frame, Missing ACK, or Bit Stuf
fi
ng Error on CAN signals up to 1 Mb/s. Data can be further speci
fi
ed to trigger on
≤
, <, =, >,
≥
, or
≠
a speci
fi
c
data value. User-adjustable sample point is set to 50% by default.
RS-232/422/485/UART
(optional)
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error.
LIN (optional)
Trigger on Sync, Identi
fi
er, Data, Identi
fi
er and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors.
Parallel (available
on MSO models
only)
Trigger on a parallel bus data value.
www.tektronix.com
11

Data Sheet
Acquisition Modes
Mode
Description
Sample
Acquire sampled values.
Peak Detect
Captures glitches as narrow as 3.5 ns at all sweep
speeds.
Averaging
From 2 to 512 waveforms included in average.
Roll
Scrolls waveforms right to left across the screen at
sweep speeds slower than or equal to 40 ms/div.
Waveform Measurements
Measurement
Description
Cursors
Waveform and Screen.
Automatic
Measurements
29, of which up to four can be displayed on-screen
at any one time. Measurements include: Period,
Frequency, Delay, Rise Time, Fall Time, Positive
Duty Cycle, Negative Duty Cycle, Positive Pulse
Width, Negative Pulse Width, Burst Width, Phase,
Positive Overshoot, Negative Overshoot, Peak
to Peak, Amplitude, High, Low, Max, Min, Mean,
Cycle Mean, RMS, Cycle RMS, Positive Pulse
Count, Negative Pulse Count, Rising Edge Count,
Falling Edge Count, Area and Cycle Area.
Gating
Isolate the speci
fi
c occurrence within an acquisition
to take measurements on, using either the screen,
or waveform cursors.
Waveform Math
Characteristic
Description
Arithmetic
Add, subtract, and multiply waveforms.
FFT
Spectral magnitude. Set FFT Vertical Scale
to Linear RMS or dBV RMS, and FFT Window
to Rectangular, Hamming, Hanning, or
Blackman-Harris.
Software
Product
Description
NI LabVIEW
SignalExpress™
Tektronix Edition
A fully interactive measurement software
environment optimized for the MSO/DPO2000
Series, enables you to instantly acquire,
generate, analyze, compare, import, and save
measurement data and signals using an intuitive
drag-and-drop user interface that does not require
any programming.
Standard MSO/DPO2000 Series support for
acquiring, controlling, viewing, and exporting
your live signal data is permanently available
through the software. The full version (SIGEXPTE)
adds additional signal processing, advanced
analysis, mixed signal, sweeping, limit testing, and
user-de
fi
ned step capabilities and is available for a
30-day trial period standard with each instrument.
OpenChoice
®
Desktop
Enables fast and easy communication between
a Windows PC and the MSO/DPO2000
Series. Transfer and save settings, waveforms,
measurements, and screen images. Included
Word and Excel toolbars automate the transfer
of acquisition data and screen images from
the oscilloscope into Word and Excel for quick
reporting or further analysis.
IVI Driver
Provides a standard instrument programming
interface for common applications such as
LabVIEW, LabWindows/CVI, Microsoft .NET, and
MATLAB.
eScope
Enables control of the MSO/DPO2000 Series over
a network connection through a standard web
browser. Simply enter the IP address or network
name of the oscilloscope and a web page will be
served to the browser.
12
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Display Characteristics
Characteristic
Description
Display Type
7 in. (180 mm) liquid crystal TFT color display.
Display Resolution
480 horizontal × 234 vertical pixels (WQVGA).
Waveform Styles
Vectors, Dots (In Video Trigger mode), Variable
Persistence, In
fi
nite Persistence.
Graticules
Full, Grid, Cross Hair, Frame.
Format
YT and XY.
Maximum Waveform
Capture Rate
Up to 5,000 wfm/s.
Input/Output Ports
Port
Description
USB 2.0 High-speed
Host Port
Supports USB mass storage devices and
keyboards. One port available on front panel.
USB 2.0 High-speed
Device Port
Rear-panel connector allows for
communication/control of oscilloscope through
USBTMC or GPIB with a TEK-USB-488, and direct
printing to all PictBridge-compatible printers.
LAN Port
RJ-45 connector, supports 10/100Base-T (requires
DPO2CONN).
Video Out Port
DB-15 female connector, connect to show the
oscilloscope display on an external monitor or
projector (requires DPO2CONN).
Auxiliary Input
Front-panel BNC connector. Input Impedance
1 M
Ω
±2%. Max input 300 V
RMS
CAT II with peaks
≤
±450 V.
Probe Compensator
Output
Front-panel pins
Amplitude: 5 V
Frequency: 1 kHz
Kensington Style
Lock
Rear-panel security slot connects to standard
Kensington-style lock.
Power Source
Characteristic
Description
Power Source
Voltage
100 to 240 V ±10%
Power Source
Frequency
45 to 65 Hz (90 to 264 V)
360 to 440 Hz (100 to 132 V)
Power Consumption
80 W maximum
Optional TekVPI
®
External Power
Supply (119-7465-xx)
Output Voltage: 12 V
Output Current: 5 A
Power Consumption: 50 W
Physical Characteristics
Dimensions
mm
in.
Height
180
7.1
Width
377
14.9
Depth
134
5.3
Weight
kg
lb.
Net
3.6
7.9
Shipping
6.2
13.7
Rackmount Con
fi
guration
4U
Cooling Clearance
2 in. (50 mm) required on left side and rear
of instrument
Environmental
Characteristic
Description
Temperature
Operating
0 ºC to +50 ºC
Nonoperating
-40 ºC to +71 ºC
Humidity
Operating
High: 30 ºC to 50 ºC, 5% to 60% Relative Humidity
Low: 0 ºC to 30 ºC, 5% to 95% Relative Humidity
Nonoperating
High: 30 ºC to 55 ºC, 5% to 60% Relative Humidity
Low: 0 ºC to 30 ºC, 5% to 95% Relative Humidity
Altitude
Operating
3,000 meters (9,843 feet)
Nonoperating
12,000 meters (39,370 feet)
Random Vibration
Operating
0.31 G
RMS
from 5 to 500 Hz, 10 minutes each axis,
3 axes, 30 minutes total
Nonoperating
2.46 G
RMS
from 5 to 500 Hz, 10 minutes each axis,
3 axes, 30 minutes total
Regulatory
Electromagnetic
Compatibility
EC Council Directive 2004/108/EC
Safety
UL61010-1:2004;
CAN/CSA C22.2 No. 61010.1-04;
EN61010-1:2001;
Complies with the Low Voltage Directive
2004/108/EC for Product Safety.
www.tektronix.com
13

Data Sheet
Ordering Information
DPO2000 Models
Product
Description
DPO2012
100 MHz, 1 GS/s, 1M record length,
2-channel digital phosphor oscilloscope
DPO2014
100 MHz, 1 GS/s, 1M record length,
4-channel digital phosphor oscilloscope
DPO2024
200 MHz, 1 GS/s, 1M record length,
4-channel digital phosphor oscilloscope
MSO2000 Models
Product
Description
MSO2012
100 MHz, 1 GS/s, 1M record length,
2+16 channel mixed-signal oscilloscope
MSO2014
100 MHz, 1 GS/s, 1M record length,
4+16 channel mixed-signal oscilloscope
MSO2024
200 MHz, 1 GS/s, 1M record length,
4+16 channel mixed-signal oscilloscope
All Models Include
: One TPP0200 200 MHz, 10X Passive Probe per Analog
Channel, User Manual and Translated Front-panel Overlay, Documentation CD
(063-4118-xx), OpenChoice
®
Desktop Software, NI LabVIEW SignalExpress™
Tektronix Edition LE Software, Calibration certi
fi
cates document measurement
traceability to National Metrology Institute(s) and ISO9001 Quality System
Registration, Power Cord, and a three-year warranty. Please specify power plug and
manual version when ordering.
MSO Models also Include
: One P6316 16-channel logic probe and accessory kit,
and accessory bag (016-2008-xx).
Application Modules
Modules
Description
DPO2AUTO
Automotive Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
CAN bus and LIN bus as well as analytical tools
such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time stamp information.
DPO2COMP
Computer Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
RS-232/422/485/UART buses as well as analytical
tools such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time stamp information.
DPO2EMBD
Embedded Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
I
2
C and SPI buses as well as analytical tools such
as digital views of the signal, bus views, packet
decoding, search tools, and packet decode tables
with time stamp information. Only two-wire SPI
support available on DPO2012, MSO2012 models.
14
www.tektronix.com

Mixed Signal Oscilloscopes — MSO2000 Series, DPO2000 Series
Instrument Options
Power Plug Options
Option
Description
Opt. A0
North America
Opt. A1
Universal Euro
Opt. A2
United Kingdom
Opt. A3
Australia
Opt. A5
Switzerland
Opt. A6
Japan
Opt. A10
China
Opt. A11
India
Opt. A99
No power cord
Language Options*
2
Option
Description
Opt. L0
English manual
Opt. L1
French manual
Opt. L2
Italian manual
Opt. L3
German manual
Opt. L4
Spanish manual
Opt. L5
Japanese manual
Opt. L6
Portuguese manual
Opt. L7
Simpli
fi
ed Chinese manual
Opt. L8
Traditional Chinese manual
Opt. L9
Korean manual
Opt. L10
Russian manual
Opt. L99
No manual
*
2
Language options include translated front-panel overlay for the selected language(s).
Service Options*
3
Option
Description
Opt. C3
Calibration Service 3 years.
Opt. C5
Calibration Service 5 years.
Opt. CA1
Provides a single calibration event, or coverage
for the designated calibration interval, whichever
comes
fi
rst.
Opt. D1
Calibration Data Report.
Opt. D3
Calibration Data Report 3 years (with Opt. C3).
Opt. D5
Calibration Data Report 5 years (with Opt. C5).
Opt. R5
Repair Service 5 years (including warranty).
*
3
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the
datasheet of each probe and accessory model for its unique warranty and calibration terms.
Recommended Probes
Probe
Description
TAP1500*
4
1.5 GHz TekVPI
®
single-ended active probe
TDP0500*
4, 6
500 MHz TekVPI 42 V differential probe
TCP0030*
4
120 MHz TekVPI 30 Ampere AC/DC current probe
TCP0150*
4
20 MHz TekVPI 150 Ampere AC/DC current probe
TCPA300/400*
7
Current measurement system ampli
fi
ers
TCP305
DC to 50 MHz, 50 Ampere current probe for use
with TCPA300
TCP404XL
DC to 2 MHz, 500 Ampere current probe for use
with TCPA400
P5100A
2.5 kV, 500 MHz, 100X high-voltage passive probe
TMDP0200*
4
±750 V, 200 MHz high-voltage differential probe
THDP0200*
4
±1.5 kV, 200 MHz high-voltage differential probe
THDP0100*
4
±6 kV, 100 MHz high-voltage differential probe
ADA400A*
4, 5
100X, 10X, 1X, 0.1X high-gain differential ampli
fi
er
Recommended Accessories
Accessory
Description
DPO2CONN
Adds Ethernet (10/100Base-T) and Video Out Port
071-2331-xx
Service Manual (English only)
TPA-BNC*
4
TekVPI to TekProbe BNC adapter
TEK-DPG*
4
TekVPI Deskew Pulse Generator Signal Source
067-1686-xx
Deskew and Calibration Fixture
196-3508-xx
Digital Probe Leadset (8 channels)
119-7465-xx
TekVPI
®
External Power Supply
SIGEXPTE
NI LabVIEW SignalExpress Tektronix Edition
Software – Full Version
TEK-USB-488
GPIB-to-USB adapter
ACD2000
Soft Transit Case and Front Protective Cover
200-5045-xx
Front Protective Cover
HCTEK4321
Hard Transit Case (requires ACD2000)
RMD2000
Rackmount Kit. Does not include slide-out rails.
*
4
Requires TekVPI external power adapter (119-7465-00); one per oscilloscope.
*
5
Requires TPA-BNC adapter.
*
6
Probes terminate into 50
Ω
but oscilloscope will automatically adjust to account for 1 M
Ω
input.
*
7
Requires 50
Ω
feed through termination between the oscilloscope input and the BNC cable.
Warranty
Three-year warranty covering all parts and labor, excluding probes.
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix
Standard Codes and Formats.
www.tektronix.com
15

Data Sheet
Contact Tektronix:
ASEAN / Australasia
(65) 6356 3900
Austria
00800 2255 4835*
Balkans, Israel, South Africa and other ISE Countries
+41 52 675 3777
Belgium
00800 2255 4835*
Brazil
+55 (11) 3759 7627
Canada
1 800 833 9200
Central East Europe and the Baltics
+41 52 675 3777
Central Europe & Greece
+41 52 675 3777
Denmark
+45 80 88 1401
Finland
+41 52 675 3777
France
00800 2255 4835*
Germany
00800 2255 4835*
Hong Kong
400 820 5835
India
000 800 650 1835
Italy
00800 2255 4835*
Japan
81 (3) 6714 3010
Luxembourg
+41 52 675 3777
Mexico, Central/South America & Caribbean
52 (55) 56 04 50 90
Middle East, Asia, and North Africa
+41 52 675 3777
The Netherlands
00800 2255 4835*
Norway
800 16098
People’s Republic of China
400 820 5835
Poland
+41 52 675 3777
Portugal
80 08 12370
Republic of Korea
001 800 8255 2835
Russia & CIS
+7 (495) 7484900
South Africa
+41 52 675 3777
Spain
00800 2255 4835*
Sweden
00800 2255 4835*
Switzerland
00800 2255 4835*
Taiwan
886 (2) 2722 9622
United Kingdom & Ireland
00800 2255 4835*
USA
1 800 833 9200
* European toll-free number. If not accessible, call: +41 52 675 3777
Updated 10 February 2011
For Further Information.
Tektronix maintains a comprehensive, constantly expanding
collection of application notes, technical briefs and other resources to help engineers working
on the cutting edge of technology. Please visit
www.tektronix.com
Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
issued and pending. Information in this publication supersedes that in all previously published material.
Speci
fi
cation and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks
of their respective companies.
06 Dec 2011
3GW-22048-3
www.tektronix.com