DOC--PEM--COMet6--US--02/08/00

COMet

 


background image

The information in the present documentation is not of a
contractual nature. It is subject to modification without prior
notice.

The software described in this manual is regulated by a user
license. The software cannot be used, copied or reproduced on
any media whatsoever, except in compliance with the terms of
this license.

No part of this manual may be copied, reproduced or
transmitted by any means whatsoever (unless it is for the
purchaser’s personal use) without the written permission of

Teklynx International Co.

E

2000

Teklynx International Co,

All rights reserved.

Windows

t

t

t

t

,

MS-DOS

â

are registered trade marks of the

Microsoft

â

Corporation

.

IBM

,

PC

,

AT PS/2

are registered trade marks of the

International Business Machines

, Inc.

 


background image

Table of Contents

About this Manual

Page - 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Documents Supplied

Page - 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Typographical Conventions

Page - 1

. . . . . . . . . . . . . . . . . . . . . . . .

Quick Guided Tour

Page 2 - 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction

Page 2 - 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Presentation of the Zoo Shipping Company

Page 2 - 4

. . . . . . . . . . . .

Setting Up the Environment

Page 2 - 5

. . . . . . . . . . . . . . . . . . . . . . .

Data Acquisition

Page 2 - 9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating a New Protocol

Page 2 - 11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting Settings for the Bar code Reader

Page 2 - 12

. . . . . . . . .

1

2

 


background image

About this Manual

Complete documentation is available to help you get the most
from COMet.

By means of an example, the

Quick Guided Tour

aims to

familiarize you quickly with the software, giving you the basic
keys for getting started. This documentation has been designed
as a compliment to the online help.

Online Help

is accessible from the application, and outlines all

application procedures.

This manual distinguishes between different types of information
by using the following conventions:

S

terms taken from the interface itself, such as commands,
appear in

bold

;

S

keys appear in small caps, as in the following example:
”Press the

SHIFT

key”;

S

numbered lists mean there is a procedure to be carried out;

S

when the conjunction ”or” appears next to a paragraph it
means there is the choice of another procedure for carrying
out a given task ;

S

When a menu command contains submenus, the menu name
followed by the command to select appears in bold. Thus,
”Choose

File Open

” means choose the

File

menu, then the

Open

command.

Following this symbol you will find hints for optimizing certain
tasks, speeding up the execution of commands, etc.

Documents
Supplied

Typographical
Conventions

1

 


background image

Quick Guided Tour

Introduction

The guided tour provides a quick introduction to get you off to a
good start with the basic functions of

COMet

. By means of a

practical example, you will learn how to create a new hardware
environment and configure source devices using different
communication protocols.

This example features a weighing machine, a bar code reader
and keyboard data entry as means of gathering the information
needed to ship packages.

The information gathered is inserted in the label below :

ZOO SHIPPING COMPANY

kg

5.750

x

2

Total

11.50

Destination:

Figure 1

Presentation of the Example Label

2

 


background image

Page 2 -- 4

Quick Start Guide

Presentation of the Zoo Shipping Company

The ZOO Shipping Company’s dispatch service has developed a
package shipping system using

COMet

. Each package must be

accompanied by a delivery slip.

Outgoing packages are routinely weighed and a light beam reads
the bar codes on each package. An operator responsible for
supervising the process enters the price per kilo.

Weighing the package makes it possible to calculate its shipping
price, and reading the bar code indicates its destination.

The information gathered is inserted into the shipping label (see
Page 2 - 3). This enables the company to keep a precise
reference number for each outgoing package.

Figure 2

Presentation of the Example Label

Note

This is just an example, of course. In real life, the price of ship-
ping a package, which depends on its destination, would be
calculated by a database, not an operator.

 


background image

Page 2 -- 5

Quick Guided Tour

This sequence describes the shipping department’s hardware
configuration and gives the procedure for creating the work
environment.

"

"

"

"

Hardware Devices

S

A PC

S

A printer connected to the PC’s COM 1 port

S

A bar code reader connected to the PC’s COM 2 port

S

A weighing machine connected to the PC’s COM 3 port

Note

The PC, which originally had only two serial ports, has been
fitted with a multiport card. Four serial ports have been added
to the first two, making a total of six. Using the

Options

dialog

box, you will have to disable ports 7 and 10, which will not be
used in this example.

"

"

"

"

Setting Up the Work Environment

Using the

COMet

interface, you will now create the device group

by adding the bar code reader and the weighing machine to the
above ports.

1

Click on

or press

F2.

2

Select

Default

as hardware environment.

The interface appears as shown below :

Figure 3

The Main COMet Window

3

Go to Port 2, then click on

or press

F8

.

The

Selection

dialog box appears.

4

Select the HBCR8000 protocol used by the bar code reader,
then click on OK.

Setting Up the
Environment

 


background image

Page 2 -- 6

Quick Start Guide

5

Repeat this procedure for Port 3 and select the TEC-SL47
protocol used by the weighing machine.

The table now looks like the example shown below :

Figure 4

Selecting Protocols

"

"

"

"

Selecting the Target Document

1

Click on

or press

F4

.

2

Select the

Shipping

label from the

COMet Samples

folder.

This label contains several

Var

fields:

S

Destination

: the data will be acquired when the bar code

on the package is read; ;

S

kg

: the value will be acquired when the package is wei-

ghed; ;

S

CodeOp

: the value is the price per kilo, entered by the ope-

rator; ;

S

Total

: the result of the formula (kg x CodeOp), which will be

the dispatch price of the package.

"

"

"

"

Device Settings

When you configure device settings, you must assign an
” uncoded ” name, (unlimited length) to the device, designate a

master

device and select the target field in which the data

acquired is to be inserted.

 


background image

Page 2 -- 7

Quick Guided Tour

Selecting Settings for the Bar code Reader :

1

Go to port 2.

2

Click on

or press

F9

.

The

Source device settings

dialog box appears :

Complete

the boxes

indicated,

then click on

OK.

Figure 5

Configuring the Bar code Reader

Selecting Settings for the Weighing Machine :

1

Go to port 3

2

Click on

or press

F9

.

The

Source device settings

dialog box appears :

Complete

the boxes as

shown, then

click on OK.

Figure 6

Configuring the Weighing Machine

 


background image

Page 2 -- 8

Quick Start Guide

Selecting Keyboard Settings

1

Go to the row in the table corresponding to the keyboard.

2

Click on

or press

F9

.

The

Source device settings

dialog box appears. Since the

keyboard is a special device, the dialog box contains only one
box for selecting the target field.

Complete

the box as

shown, then

click on OK.

Figure 7

Configuring the Keyboard

Once the information is entered, the main

COMet

window looks

like this :

Figure 8

Displaying the Configured Devices

 


background image

Page 2 -- 9

Quick Guided Tour

"

"

"

"

Saving the Environment

Now you have created your environment, you will save it so that
it can be used later.

1

Click on

or press

F3

.

The

Save as

dialog box appears :

2

Enter

SHIPPING.CMT

as the environment name, then click on

OK.

To launch data acquisition:

1

Click on

or press

F6

.

The

Transfer

dialog box appears.

Figure 9

The

Transfer dialog box

2

Check the

Update only

box: data will be sent to the labeling

software and inserted into the label

Var

fields.

or
Check the

Update and print

box if you wish to both update

the

Var

fields and print in real time at the same time.

Data Acquisi-
tion

 


background image

Page 2 -- 10

Quick Start Guide

Values are displayed one by one in the table.

Figure 10

Displaying Values during Transfer

To show that the transfer process is taking place, the

but-

ton becomes

.

Obtaining a Preview

S

To better monitor the process, request a label preview by

click on

or by pressing

F7

.

Figure 11

Label Preview

 


background image

Page 2 -- 11

Quick Guided Tour

Creating a New Protocol

It is entirely possible that the protocol used by your device is
unavailable in

COMet

. If so, you must define it using the

technical information sheet that came with your device.

Let us suppose that the ZOO Shipping Company has just
purchased a new bar code reader, the protocol of which is not
recognized by

COMet

.

Excerpt from the manufacturer’s information:

Quazar Bar Code Reader
Protocol : TX-22
Type : touch reader
Communication parameter :
Speed : 2,400 baud
Data bits : 8
Parity : none
Stop bit : 1
Initialization :

Sequence

Check characters on

Check characters off

09 01

09 00

Configuration

n = 00 or 01

Reading

nnn =

code data +

check character

09 n

OK

01nnn 02

 


background image

Page 2 -- 12

Quick Start Guide

1

Click on

or press

F8

.

The protocol

Selection

dialog box appears.

2

Click on

New

.

3

Click on

or press

F9

.

The

Source device settings

dialog box appears.

4

Using the manufacturer’s information, complete the diffe-
rents boxes as shown below :

Figure 12

Configuring a source device

5

Once the dialog box has been completed, click on

Settings...

The

Protocol

dialog box appears.

6

Check the

Proceed with this step

box, then complete the

text boxes by referring to the manufacturer’s information.
Here we are looking to obtain the bar code’s check character.

Selecting Set-
tings for the
Bar code Rea-
der

 


background image

Page 2 -- 13

Quick Guided Tour

"

"

"

"

Initialization Step

To retrieve this check character, and in accordance with the
device specifications, you must send the command ” 0901 ”, or
^I^A (see note below).

We will then delete this data check character as in our case, the
sole purpose of initialization is to make sure the reader is wor-
king correctly.

Note

The following special characters cannot be directly entered into
the text box:
- ASCII check characters (ASCII 1 to 31)
- quotation marks (ASCII 34)
- commas (ASCII 44)
- semicolons (ASCII 59)
- equal signs (ASCII 61)
- circumflex accents (ASCII 94)
- spaces (ASCII 32)
- extended ASCII characters (ASCII 128 onwards)
- backslashes (ASCII 124)
To enter these characters, use one of the following notations :

1

^#, #

is a capital letter from A to Z and replaces the

ASCII characters from 1 to 26.

Example: ^F for the 6 byte.

2

^###,### is a decimal number above 0 (length
is fixed at 3 digits).

Example: ^034 for the double quotation marks, or ^094

for

the circumflex accent.

S

To enter this command, enter ” ^I^A ” (in

Windows

TM

enter a space after the circumflex accent) :
^, space, I, ^, space, A.

Still following the manufacturer’s specifications, the reader
should send back an ” OK ”. If there is nothing after 500 ms, the
communication is deemed to have failed, and the user must then
decide what to do.

 


background image

Page 2 -- 14

Quick Start Guide

"

"

"

"

Wait Stage

Figure 13

Wait Stage

S

Check the

When receiving a message sent by the device

box, since the data is transmitted as soon as the reader’s
trigger is activated.

"

"

"

"

Data Acquisition

This step allows you to check whether the data received meets
user expectations.

Figure 14

Data Acquisition

In our case, we are expecting a variable message.

According to the manufacturer’s specifications, and whatever the
nature of the bar code, the message takes the form ” 01 n n n
n

¼

check 02 ”. It is contained within the codes ” 01 ” and ” 02 ”,

contains a variable number of characters and may contain a
check code at the end.

 


background image

Page 2 -- 15

Quick Guided Tour

S

Enter ” ^A*^B ”.

^A : message start character,

* : joker replacing a given number of characters,

^B : message stop character.

"

"

"

"

Data Extraction

In this step, we will define the structure and nature of the
message, and specify which part of the message we want to
retrieve.

L

O

N

M

K

Figure 15

Data Extraction

Key:

K

We know that the message is of

variable length

.

L

The first data byte is placed in second position, after the

message start byte.

M

The stop character is ^B.

N

We want an offset of -1 byte to exclude the check character

(it is not necessary to keep this information, since the labeling
program recalculates the check character).

O

Coding is

Alphanumerical

; bytes received will be transmit-

ted without being converted.

Using the

Example

box, check that the message features the

correct parameters.

 


background image

Page 2 -- 16

Quick Start Guide

"

"

"

"

Saving the New Protocol

Now that the protocol is configured, you need to save it.

1

Click on

Save as

.

The

Saving the protocol

dialog box appears. :

Figure 16

Saving the Protocol

The box features three text entry boxes allowing you to input
precise reference information for any new protocol.

2

Complete all boxes with the values mentioned above.

Try to include the model revision number in the protocol box as
manufacturers may change the message protocols from one pro-
duction run to the next.
For example: TX-22 1998

Note

For the sake of simplicity, in this exercise we have not included
a data availability enquiry (Query) or a reset sequence (Reset).