Medical Computer   

TMT-4391-08 Series 

Startup Manual 

TMT-4391-08 Appearance 

 

Left: Front View       Right: Rear View 

 
For more information on this and other Teguar 
products, please visit our website at: 
 

http://www.teguar.com

 

 
For technical support and service, please visit 
our support website at: 
 

http://www.teguar.com/support

 

 
 
 
This manual is for TMT-4391-08 Series 
 
                               3rd Edition 
Print in China                   August 2018   

 

 

 

 

 

 

Description of Parts 

 

A: Front Camera 
B: Power LED

 

C: Light Sensor 
D: Speaker 
E: micro-SIM & micro-SD Card Door 
F: Programmable Key (Default 
Barcode scanner) 
G: Pogo Pin (USB3.0) 
H: Micro USB Door 
I: Micro HDMI Door 
J: Power Button 
K: Volume Key (Up/Down) 
L: Audio Jack (Headset Combo) 
M: Extension Module 
N: NFC 
O: Rear Camera with LED Flash 
P: Battery Cover 

 

 

 

 

 

 

 

 


background image

Easy Setup 

 

Power On Computer 

 

1. 

Model: TMT-4391-08 Rating 5 Vdc / 3.0A 

2. 

This product is intended to be supplied by a UL 
Listed Power Adapter (Phihong / MM18M-59A) or 
DC power source, rated 5 Vdc, 3A min. for model 
TMT-4391-08, and Tma  45  degree C. Please 
contact  Teguar  for further information and 
assistance. 

3. 

The product is equipped with shipping mode for 
battery protected and power saving, please charge 
the embedded battery of the computer: Connect 
the Micro USB adaptor on the TMT-4391-08 
computer. (“H” on the description of parts.) Please 
charge for at least one hour when you use this 
computer for the first time.

 

4. 

Push the Power button (“J” on description of parts.) 
for 2~3 seconds to start the computer.

 

5. 

The product is equipped with a 8”  Capacitive 
Touch Panel. Use finger, capacitive stylus, or nitrile 
gloves  to touch the following Active Area to 
operate the computer.   

6. 

The product is equipped with one LED indicator for 
battery status. The following shows LED status for 
different power states: 
a)  The orange LED blinks when internal battery 

capacity is below 10% to warn the user to 
charge. 

b)  The Blue LED lights up when internal battery is 

being charged. 

c)  The Green LED lights up when internal battery 

has been fully charged. 

7. 

While the computer is running, push the power 
button for 1 second will disable LCD backlight for 
power saving. Push the power button again will 
enable the backlight again; press the power button 
for 10 seconds while computer is running, the 
system will shut down. 

8. 

Environment: 

 Operating Temperature: -10°C ~ +50 °C 

 Operating Humidity : 10% ~ 90%@30°C 

non-condensed 

 Storage/Transportation Temperature:   

-40°C ~ +80°C (Internal lab test)

 

 Storage/Transportation Humidity : 

5% ~ 95%@30°C non-condensed 

 Humidity consider to 25

°

C, 48 hrs 

 Number and type of Means of Protection :   

MOPP Altitude 3000m   

 Atmospheric pressure

  700-1013 hPa (for 

operating); 500-1013 hPa (for 
Storage/Transportation) 

 IP level : 

IPX0

 

9. 

There will be “TEGUAR”  logo upside down while 
first boot up. This scenario will be disappear after 
2

nd

  boot up and won’t influence functions and 

usage.   

 

Intended Use

 

 
The TMT-4391-08 is intended for integration with 
hospital system. It is designed for general purpose for 
hospital environment. 
For data collection and display for reference. 
It should not be used for life-supporting system. 
 
 
 

EMC Table 

 

Guidance and Manufacturer’s Declaration – 
Electromagnetic Emissions

 

 
The model TMT-4391-08 is intended for use in an 
electromagnetic environment as specified below. The 
customer or the user of the TMT-4391-08 should assure 
that it is used in such an environment. 
 

Emissions Test

 

Compliance

 

Electromagnetic 
Environmental

 

Guidance

 

 
 

 

 

 

 

 

 

 

 

 

The model 
TMT-4391-08 uses 
RF 

 

RF emissions 

 

energy only for its 
internal func- 

 

Group 1 

tion. Therefore, its RF 
emissions 

 

CISPR 11 

are very low and are 
not likely to 

 

 

 

 

 

cause any 
interference in nearby  

 

 

electronic equipment.  

 

 

 

RF emissions 

Class B 

The model 
TMT-4391-08 is 
suitable 

CISPR 11 

 

 

for use in all 
establishments, 

 

 

 

 

 

 

 

Harmonic 
emissions 

Class A 

including domestic 
establishments 

 

IEC 61000-3-2 

and those directly 
connected to 

 

 

 

 

 

the public low-voltage 
power sup- 

 

Voltage 
fluctuations/ 

 

 

 

ply network that 
supplies buildings 

 

flicker emissions  Not applicable 

 

used for domestic 
purposes. 

 

IEC 61000-3-3 

 

 

 

 

 

 

 

 

 

 


background image

 
Recommended Separation Distances Between

 

Portable and Mobile RF Communications Equipment 
and the TMT-4391-08

 

 
TMT-4391-08 is intended for use in an electromagnetic 
environment in which radiated RF disturbances are 
controlled. The customer or the user of the model 
TMT-4391-08 can help prevent electromagnetic 
interference by maintaining a minimum distance between 
portable and mobile RF communications equipment 
(transmitters) and the model TMT-4391-08 as 
recommended below, according to the maximum output 
power of the communications equipment. 
 

Rated 
Maximum

 

 

Output 
Power of

 

Separation Distance According to 
Frequency of Transmitter

 

Transmitter

 

m

 

 

 

W

 

 

 

 

 

 

 

 

 

150 kHz to 
80 MHz

 

80 MHz to 
800 MHz

 

800 MHz to 
2,5 GHz

 

 

d = 

1,2

  P

 

d = 

1,2

  P

 

d = 

2,3

  P

 

 

 

 

 

0,01 

0,12 

0,12 

0,23 

 

 

 

 

0,1 

0,38 

0,38 

0,73 

 

 

 

 

1,2 

1,2 

2,3 

 

 

 

 

10 

3,8 

3,8 

7,3 

 

 

 

 

100 

12 

12 

23 

 

 

 

 

For transmitters rated at a maximum output power not 
listed above, the recommended separation distance 

d

 in 

meters (m) can be estimated using the equation in the 
table above applicable to the frequency of the transmitter, 
where 

P

 is the maximum output power rating of the 

transmitter in watts (W) according to the transmitter 
manufacturer. 
 
NOTE 1 At 80 MHz and 800 MHz, the separation 
distance for the higher frequency range applies. 
 
NOTE 2 These guidelines may not apply in all situations. 
Electromagnetic propagation is affected by absorption 
and reflection from structures, objects and people. 

 
 
Guidance and Manufacturer’s Declaration – 
Electromagnetic Immunity

 

 
TMT-4391-08 is intended for use in the electromagnetic 
environment specified below. The customer or the user 
of the model TMT-4391-08 should assure that it is used 
in such an environment. 
 
 

 

Immunity 
Test

 

IEC 60601 
Test

 

Compliance

 

Electromagnet
ic 
Environmental

  

Level

 

Level

 

Guidance

 

 

 

 

 

 

 

 

 

Electrostatic 
dis- 

 

 

Floors should 
be wood, con-   

±

8 kV 

contact 

±

8 kV 

contact 

crete or ceramic 
tile. If floors 

 

charge (ESD) 

are covered 
with synthetic 

 

±

15 kV 

air 

±

15 kV air 

 

IEC 
61000-4-2 

material, the 
relative 
humidity 

 

 

 

 

 

 

 

should be at 
least 30%. 

 

 

 

 

 

 

Electrical fast 

±

2 kV for 

power 

±

2 kV for 

power 

 

 

supply lines  supply lines 

Main power 
quality should 
be 

 

transient/bur
st 

 

 

 

that of a typical 
commercial or 

 

 

±

1 kV for 

input/out- 

±

1 kV for 

input/ 

 

IEC 
61000-4-4 

hospital 
environment. 

 

put lines 

output lines 

 

 

 

 

 

 

 

 

 

 

 

±

1 kV 

line(s) to 

±

1 kV 

line(s) to 

Main power 
quality should 
be 

 

Surge 

line(s) 

line(s) 

 

that of a typical 
commercial or 

 

IEC 
61000-4-5 

±

2 kV 

line(s) to 

±

2 kV 

line(s) to 

 

hospital 
environment. 

 

 

earth 

earth 

 

 

 

 

 

 

 

 

 

 

<5% 

U

(>95% dip 

<5% 

U

 

 

 

(>95% dip in   

 

 

in 

U

T) for 

0,5 cycle 

U

T) for 0,5 

Main power 
quality should 
be 

 

 

 

cycle 

 

 

40% 

U

 

that of a typical 
commercial or   

Interruptions 
and 

(60% dip in 

U

T) 

40% 

U

(60% 

hospital 
environment. If 
the 

 

voltage varia- for 5 cycles 

dip in 

U

T) for 

user of the 
model 
TMT-4391-08   

tions on 
power 

 

cycles 

requires 
continued 
operation 

 

supply input 
lines 

70% 

U

 

during main 
power interrup-   

 

(30% dip in 

U

T) 

70% 

U

(30% 

tion, it is 
recommended 
that 

 

IEC 
61000-4-11 

for 25 
cycles 

dip in 

U

T) for 

the model 
TMT-4391-08 
be 

 

 

 

25 cycles 

powered from 
an uninterrupt-   

 


background image

 

<5% 

U

<5% 

U

ible power 
supply or a 
battery. 

 

 

(>95% dip 
in 

U

T) 

 

 

 

for 5 sec 

(>95% dip in   

 

 

 

U

T) for 5 sec  

 

 

 

 

 

 

Power 
frequency 

 

 

Power 
frequency 
magnetic 

 

 

 

fields should be 
at levels 

 

(50/60 Hz) 

 

 

 

3 A/m 

3 A/m 

characteristic of 
a typical 

 

magnetic 
field 

 

 

 

location in a 
typical commer- 

 

IEC 
61000-4-8 

 

 

 

 

 

cial or hospital 
environment. 

 

 

 

 

 

 

 

 

 

 

NOTE 

U

T is the A.C. main voltage prior to application of 

the test level. 

 
 
Guidance and Manufacturer’s Declaration – 
Electromagnetic Immunity

 

 
The model TMT-4391-08 is intended for use in the 
electromagnetic environment specified below. The 
customer or the user of the model TMT-4391-08 should 
assure that it is used in such an environment. 
 

Immunity

 

IEC 60601 
Test

 

Compliance

 

Electromagnet
ic 
Environmental

  

test

 

Level

 

Level

 

Guidance

 

 

 

 

 

 

 

 

 

 

Portable and 
mobile RF 
communi- 

 

 

 

 

cations 
equipment 
should be used   

 

 

 

no closer to any 
part of the 
model 

 

 

 

 

TMT-4391-08, 
including 
cables, than 

 

 

 

 

the 
recommended 
separation dis-   

 

 

 

tance 
calculated from 
the equation 

 

 

 

 

applicable to 
the frequency 
of the 

 

 

 

 

transmitter. 

 

 

 

 

Recommende
d Separation 
Dis-

 

 

 

 

 

tance

 

 

 

 

 

 

d = 

1,2  

P

 

 

 

 

 

d = 

1,2  

80 MHz to 800 
MHz 

 

Conducted 

3 Vrms 

 

 

 

 

RF 

 

d = 

2,3  

P   

800 MHz to 2,5 
GHz 

 

150 kHz to 
80 

 

 

IEC 
61000-4-6 

 

 

 

 

MHz 

Vrms 

 

 

 

 

where 

P

 is the 

maximum 
output 

 

 

 

 

Radiated 
RF 

3 V/m 

V/m 

power rating of 
the transmitter 
in 

 

watts (W) 
according to the 
transmit- 

 

80 MHz to 
2,5 

 

 

IEC 
61000-4-3 

 

ter 
manufacturer 
and 

d

 is the rec- 

 

GHz 

 

 

 

 

ommended 
separation 
distance in 

 

 

 

 

 

 

 

meters (m). 

 

 

 

 

Field strengths 
from fixed RF 
trans- 

 

 

 

 

mitters, as 
determined by 
an elec- 

 

 

 

 

tromagnetic site 
survey, 

a

 should 

be 

 

 

 

 

less than the 
compliance 
level in 

 

 

 

 

each frequency 
range. 

b

 

 

 

 

 

Interference 
may occur in the 
vicin- 

 

 

 

 

ity of equipment 
marked with the 
fol- 

 

 

 

 

lowing symbol:   

 

 

 

 

 

 
NOTE 1 At 80 MHz and 800 MHz, the higher frequency 
range applies. 
 
NOTE 2 These guidelines may not apply in all situations. 
Electromagnetic propagation is affected by absorption 
and reflection from structures, objects and people. 
 
 

 


background image

 

a

 Field strengths from fixed transmitters, such as base 

stations for radio (cellular/cordless) 
telephones and land mobile radios, amateur radio, AM 
and FM radio broadcast and TV broadcast cannot be 
predicted theoretically with accuracy. To assess the 
electromagnetic environment due to fixed RF 
transmitters, an electromagnetic site survey should be 
considered. If the measured field strength in the location 
in which the TMT-4391-08 is used exceeds the 
applicable RF compliance level above, the TMT-4391-08 
should be observed to verify normal operation. If 
abnormal performance is observed, additional measures 
may be necessary, such as reorienting or relocating the 
unit. 
 

b

 Over the frequency range 150 kHz to 80 MHz, field 

strengths should be less than 3 V/m. 
 
 

 

                                                       

Battery Caution 

 

CAUTION! 
Danger of explosion if battery is incorrectly replaced. 
Replace only with the same type recommended by the 
manufacturer, discard used batteries according to the 
manufacturer's instructions. 
 
Attention: Danger d'explosion si la batterie est 
inexactement remplacée. Remplacez seulement avec la 
même chose ou le type recommandé par le fabricant, 
jettent les batteries utilisées instructions de s selon 
fabricant des'. 
 
Mistreat the battery used in this device may present a 
risk of fire or chemical burn. 
Do not attempt to disassemble the computer or its 
accessories. 
Only qualified personal is allowed to replace the battery.   
Do not dispose batteries in a fire and check with local 
authorities for disposal instructions. 
 
TMT-4391-08 can only be equipped with standard 
battery pack with Getac, AIM-BAT-8, 4900mAH Polymer 
Lithium Ion Battery. Use of another battery may present 
a risk of fire or explosion. 
 

Battery Charge Notice 

It is important to consider the environment temperature 
whenever you are charging the Lithium-Ion battery pack. 
The process is more efficient at normal room 
temperature or slightly cooler. It is essential that you 
charge batteries within the stated range of 0°C to 40°C. 
Charging batteries outside of the specified range could 
damage the batteries and shorten their charging life 
cycle. 

 
Storage and Safety Notice 

Although charge Lithium-Ion batteries may be left 
unused for several months, their capacity may be   
depleted due to the buildup of internal resistance. If this   
happens they will require recharging prior to use. Lithium   
Ion batteries may be stored at temperatures between   

-20°C to 60°C, however they may be depleted more   
rapidly at the high end of this range. It is recommended 
to store TMT-4391-08 within normal room temperature 
ranges. 

 
 
 
 

Warnings, Cautions and Notes 

 

 

 

A WARNING statement provides important information 
about a potentially hazardous situation which, if not 
avoided, could result in death or serious injury. 
 
 
 
 
 
 
Une déclaration d'AVERTISSEMENT fournit des 
informations importantes sur une situation 
potentiellement dangereuse qui, si elle n'est pas évitée, 
pourrait entraîner la mort ou des blessures graves. 
 
 
 
 
 
 
A CAUTION statement provides important information 
about a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury to the 
user or patient or in damage to the equipment or other 
property. 
 
 
 
 
 
 
Une déclaration de MISE EN GARDE fournit des 
informations importantes sur une situation 
potentiellement dangereuse qui, si elle n'est pas évitée, 
peut entraîner des blessures mineures ou modérées 
pour l'utilisateur ou le patient ou endommager 
l'équipement ou d'autres biens. 
 
 

 
 
 
 
 
 

A NOTE provides additional information intended to 
avoid inconveniences.

 

 

Caution! 

 

Warning! 

 

Avertissement! 

 

Attention! 

 

 


background image

Safety Instructions

 

 
1. Strictly follow these instructions for use; please read 

these safety instructions carefully. 

2. Keep this user manual for later reference; any use of 

the product requires full understanding and strict 
observation of all portions of these instructions. 
Observe all. 

3. Repair of the device may also only be carried out by 

trained service personnel. 

4. Teguar recommends that a service contract be 

obtained with Teguar Service and that all repairs also 
be carried out by them. Otherwise the correct 
functioning of the device may be compromised. 

 
 

Because of the danger of electric shock, 
never remove the box of a device while 
it is in operation or connected to a 
power outlet. 

 
 

En raison du risque d'électrocution, ne 
retirez jamais la boîte d'un appareil 
lorsqu'il est en fonctionnement ou 
branché à une prise de courant. 

 
 
5. If one of the following situations arises, get the 

equipment checked by service personnel: 

 The power cord or plug is damaged. 

 Liquid has penetrated into the equipment. 

 The equipment has been exposed to moisture. 

 The equipment does not work well, or you cannot get it 

to work according to the user manual. 

 The equipment has been dropped and damaged. 

 The equipment has obvious signs of breakage. 

 
6. Disconnect this equipment from any AC outlet before 

cleaning. Use a damp cloth. Do not use liquid or spray 
detergents for cleaning and keep this equipment 
away from humidity. 

 
 

To avoid short-circuits and otherwise 
damaging the device, do not allow 
fluids to come in contact with the device. 
If fluids are accidentally spilled  on the 
equipment, remove the affected unit 
from service as  soon as possible  and 
contact service personnel to verify that 
patient safety is not compromised. 

 
 
 

Pour éviter les courts-circuits et 
endommager l'appareil, ne laissez pas 
les liquides entrer en contact avec 
l'appareil. Si des liquides sont 
accidentellement répandus sur 
l'équipement, retirez l'unité concernée 
du service dès que possible et 
contactez le personnel de service pour 
vérifier que la sécurité du patient n'est 
pas compromise. 

 
 
 

7. Put this equipment on a reliable surface during   

installation. Dropping it or letting it fall may cause   
damage. For plug-in equipment, the power outlet   
socket must be located near the equipment and must   
be easily accessible. 

 
 

Do not leave this equipment in an 
uncontrolled environment where the 
Storage temperature is below 0° C or 
above  45° C. This may damage  the 
equipment. 

 
 

Ne laissez pas cet équipement dans un 
environnement non contrôlé où la 
température de stockage est inférieure 
à 0 ° C ou supérieure à 45 ° C. Ceci 
pourrait endommager l'équipement. 

 
 
8. Grounding reliability can only be achieved when the 

equipment is connected to an equivalent receptacle 
marked “Hospital Only” or “Hospital Grade”. 

9. Use a power cord that matches the voltage of the 

power outlet, which has been approved and complies 
with the safety standard of your particular country. 

10. If the integrity of the protective earth conductor is in 

doubt. Please turn off the power switch. 

11. To disconnect this product from the mains supply 

disconnects the mains plug from the socket outlet. The 
power supply is regarded as part of this equipment. 

12. Make sure user not to contact SIP/SOPs and the 

patient at the same time. 

13. Do not switch on/off the power switch of the battery 

system during operation. 

 
 

To avoid risk of electric shock, this 
equipment must only be connected to a 
supply mains with protective earth. 
 
 
Pour éviter tout risque d'électrocution, 
cet équipement doit uniquement être 
raccordé à une alimentation secteur 
avec terre de protection. 

 
 

No modification of this equipment is 
allowed. 
 
 
 
Aucune modification de cet équipement 
n'est autorisée. 

 
 
14. The power cord for use on the device shall be no less 

robust than ordinary tough rubber sheathed flexible 
cord (IEC 60245-1:2003, Annex A, designation 53) or 
ordinary polyvinyl chloride sheathed flexible cord 
(IEC 60227-1:1993, Annex A, design. 53. For the 
US/CA the requirements of the NEC and Canadian 
code shall be followed (US and CA national 
differences). 

 
 
 
 

Warning! 

 

Warning! 

 

Warning! 

 

Caution! 

 

Caution! 

 

Avertissement! 

 

Attention! 

 

Attention! 

 

Avertissement! 

 

Avertissement! 

 

 


background image

Battery system, equipotential pin, metal 
wiring on equipotential pin, wheels and 
brake shall be replaced/send back to 
maintain by the manufacturer every two 
years, risks of function failure, electrical 
shock, equipment damage, 
environment pollution and etc. may 
occur if not doing so. 
 
 
Le système de batterie, la broche 
équipotentielle, le câblage métallique 
sur la broche équipotentielle, les roues 
et le frein doivent être remplacés / 
renvoyés par le fabricant tous les deux 
ans, les risques de défaillance de 
fonctionnement, les chocs électriques, 
les dommages matériels, etc. Ce 
faisant. 

 
 
15. If your computer clock is unable to keep accurate 

time or the BIOS configuration resets to default, 
please check the battery. 

 

When  the battery has  problem  of 
charging. Please contact a qualified 
technician or your retailer. 
The computer is provided with a 
battery-powered real-time clock circuit. 
There is a danger of explosion if battery 
is incorrectly replaced. Replace  only 
with same or equivalent type 
recommended by the manufacturer. 
Discard used batteries according to the 
manufacturer's instructions. 

 
 

Lorsque la batterie a un problème de 
charge. Veuillez contacter un 
technicien qualifié ou votre revendeur. 
L'ordinateur est équipé d'un circuit 
d'horloge en temps réel alimenté par 
batterie. 
Il y a un risque d'explosion si la batterie 
est incorrectement remplacée. 
Remplacez uniquement par le même 
type ou un type équivalent 
recommandé par le fabricant. 
Jetez les piles usagées conformément 
aux instructions du fabricant. 

 
 

When servicing the device, always use 
replacement parts that meet  Teguar 
standards.  Teguar  Medical cannot 
warrant or endorse 

the safe 

performance of third-party replacement 
parts for use with our medical device. 
 
 
Lors  de la maintenance de l'appareil, 
utilisez toujours des pièces de 
rechange conformes aux normes 
Teguar.  Teguar  Medical ne peut pas 
garantir ou endosser les performances 
sécuritaires des pièces de rechange 
tierces à utiliser avec notre dispositif 
médical. 

 

16. Make sure the user does not allow contact between 

SIP/SOPs and the patient at the same time. 

 

 
17. When networking with electrical devices, the operator 

is responsible for ensuring that the resulting system 
meets the requirements set forth by the following 
standards: 

 
– EN 60601-1 (IEC 60601-1) 

Medical electrical equipment 
Part 1: General requirements for safety 

 
– EN 60601-1-2 (IEC 60601-1-2) 

Medical electrical equipment 
Part 1-2: General requirements for safety 

Collateral standard: Electromagnetic compatibility; 
Requirements and tests 

 

18. Accessory equipment connected to analog and 

digital interfaces must be in compliance with the 
respective nationally harmonized IEC standards (i.e. 
IEC 60950 for data processing equipment, IEC 60065 
for video equipment, IEC 61010-1 for laboratory 
equipment, and IEC 60601-1 for medical equipment.) 
Furthermore all configurations shall comply with the 
system standard IEC 60601-1- 1. Anyone who 
connects additional equipment to the signal input part 
or signal output part is configuring a medical system, 
and is therefore, responsible that the system 
complies with the requirements of the system 
standard IEC 60601-1-1. The unit is for exclusive 
interconnection with IEC 60601-1 certified equipment 
in the patient environment and IEC 60XXX certified 
equipment out-side of the patient environment. If in 
doubt, consult the technical services department or 
your local representative. 

 

19. Grounding reliability can only be achieved when the 

equipment is connected to an equivalent receptacle 
marked "Hospital Only" or "Hospital Grade". 

 

20. Use a power cord that matches the voltage of the 

power outlet, which has been approved and complies 
with the safety standard of your particular country. 

 

 
Environmental protection. 
Follow national requirements to 
dispose of unit. 
 
 

21. “WARNING - Do not modify this equipment without 

authorization of the manufacturer.” 

 

22. “WARNING – To avoid risk of electric shock, this 

equipment must only be connected to a supply mains 
with protective earth. 

 
 

23. “CAUTION: This adapter PHIHONG / MM18M-59A is 

a forming part of the medical device.” 

 

24. Remove the power cord to fully turn off the device 

when the battery pack is empty. 

 
25. Classification:   

1). Class I 
2). No applied part 
3). Continuous Operation   

 

Warning! 

 

Caution! 

 

Caution! 

 

Avertissement! 

 

Attention! 

 

Attention! 

 

 


background image

Explanation of Graphical 
Symbols 

 

   

IEC 60878 and ISO 3864-B.3.6 : 
Warning dangerous voltage. 

 

ISO 7000-0434 : Caution, consult 
ACCOMPANYING DOCUMENTS. 

 

ISO 7000-1641 : Follow operating 
instructions or consult instructions for 
use. 

 

IEC 60417-5009 : STAND-BY. 

 
 

IEC 60417-5032 : Alternating Current. 

 
 

IEC 60417-5031 : Direct Current. 

 
 

ISO 7010-M002 : Follow instructions for 
us. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specifications 

 

 

 
 

Cleaning and Disinfecting 

 

During normal use of the TMT-4391-08 tablet the device 
may become dirty and should be regularly cleaned. 

 

Steps: 

1. Prepare cleaning water. 
2. Wipe the TMT-4391-08 tablet with a clean cloth that 

has been moistened in the pure water 

3. Wipe thoroughly with a clean cloth. 
 
 
 
 
 
 
Do not immerse or rinse the TMT-4391-08 tablet or its 
peripherals. If you accidentally spill liquid on the device, 
disconnect the unit from the power source. Contact your 
IT support department regarding the continued safety of 
the unit before placing it back in operation-Do not spray 
cleaning agent on the chassis. 
 
Do not use disinfectants that contain phenol. 
 

Do not autoclave or clean the POC or its peripherals with 

strong aromatic, chlorinated, ketone, ether, or ether 
solvents, sharp tools or abrasives. Never immerse 
electrical connectors in water or other liquids. 
 
 

Operating Principle 

 

The device provides input through touch panel, hard 

keys located at the bottom of it, accessories through 
USB ports or its LAN/WLAN connections. The device 
computes the input data with its processing unit and then 
output the generated data to LCD panel, accessories or 
other devices through its I/O ports or through its 
LAN/WLAN connections. The device is able to store data 
in its storage, and when the device is turned off, still 
maintain the data in the memory units of the storage. 
 
 
 

 

 

 

 

Caution! 

 

Attention! 

 

 


background image

Connecting the Power Cord 

 

The TMT-4391-08 tablet can be powered by AC in. Be 

sure to always handle the power cords by holding the 
plug ends only. 
 
Follow these procedures in order: 
 
1. Connect the female end (Micro USB side) of the power 

adapter to TMT-4391-08 tablet product micro USB 
connector. (Step 1) 

2. Connect the 3 pin male plug of the power cord to an 

electrical outlet. (Step 2) 

 
 

 

 
 
 

Intended User Profile 

 
Age: 18 to 65 
Weight: not relevant 
Health: not relevant 
Nationality: Global 
Patient state: patient will not be the operator. 
 
Part of the body or type of tissue applied to or interacted 

with: hands and fingers, expected contact time shall be 
less than 1 min. 

 
Education level: at least 8 years intensive reading 

experience (school)   

 
Knowledge:   
Minimum – read and understand “westernized Arabic” 

numerals when written in Arial font 

  can distinguish: every parts of body as described in 
user manual 

  trained and authorized by manufacturer only.   

 
To be considered as trained and authorized, they must 

complete the training course of the manufacturer; see 
document number TMT-4391-08_User Manual_Rev 
3.0 for qualification method, when considered 
necessary by the manufacturer, technician shall be 
called back for retraining and annual training is also 
considered necessary. 

 
Language understanding: English, whenever other 

languages are required, professional translation 
company shall translate and review by the 
manufacturer, see SOP document number: 
SOP_Writing_Guidelines-ed.3 

 
Experience: Mentally and physical competent, specific 

medical training to understand basic knowledge for 
symbols. 

 
Permissible impairments: 

  Mild reading vision impairment or vision corrected to 
log MAR 0,2 (6/10 or   

 
20/32) 

  One arm / hand system capable of guiding and 
holding device 

  Average degree of aging-related short term memory 
impairment 

  impaired by 40 % resulting in 60 % of normal hearing 
at 500 Hz to 2 kHz 

 
 
 

Disposing of Old Products 

 

Within the European Union 

EU-wide legislation, as 
implemented in each 
member state, requires that 
waste electrical and 
electronic products carrying 
the mark shown at left must 
be disposed of separately 
from normal household 
waste. This includes 

monitors and electrical accessories, such as signal 
cables or power cords. When you need to dis-pose 
of your display products, please follow the guidance 
of your local authority, or ask the shop where you 
purchased the product, or if applicable, follow any 
agreements made between you and the provider. 

 
The mark on electrical and electronic products only 

applies to the current European Union Member States. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 


background image

Declaration of Conformity 

CE Conformity Statement 
 

Radio products with the CE alert marking comply with the 
R&TTE Directive (1999/5/EC) issued by the Commission 
of the European Community. Compliance with this 
directive implies conformity to the following European 
Norms (in brackets are the equivalent international 
standards). 
• EN 60950-1 (IEC60950-1) - Product Safety 
• EN 300 328 Technical requirement for radio equipment 
• ET S301 489 General EMC requirements for radio 
equipment 
Products that contain the radio transmitter are labeled 
with CE alert marking and may also carry the CE logo. 
 

FCC Compliance Statement 
 

This equipment generates,  uses and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there is 
no guarantee that interference will not occur in a 
particular installation. If this equipment does cause 
harmful interference to radio or television reception, 
which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the 
interference by one of the following measures: 
• Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and 
receiver. 
• Connect the equipment into an outlet on a circuit 
different from that to which the receiver is connected. 
• Consult the dealer or an experienced radio/TV 
technician for help. 
 
To assure continued compliance, any changes or 
modifications not expressly approved by the party 
responsible for compliance could void the user's 
authority to operate this equipment. (Example: use only 
shielded interface cables when connecting to computer 
or peripheral devices). 
 
This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
1) 

This device may not cause harmful interference, 
and 

2) 

This device must accept any interference received, 
including interference that may cause undesired 
operation. 

 

15.21

   

Any changes or modifications not expressly approved by 
the party responsible for compliance could void the 
authority to operate equipment.   
This device and its antenna must not be co-located or 
operating in conjunction with any other antenna or 
transmitter.   
End-users and installers must be provided with antenna 
installation instructions and transmitter operating 
conditions for satisfying RF exposure compliance.   
For product available in the USA/Canada market, only 
channel 1~11 can be operated. Selection of other 
channels is not possible. 
 
 
 
 

FCC Radiation Exposure Statement 
 

This equipment complies with FCC RF radiation 
exposure limits set forth for an uncontrolled environment 
for body-worn configuration in direct contact to the 
phantom.   
This device complies with FCC radiation exposure limits 
set forth for an uncontrolled environment. 
 
This equipment complies with FCC radiation exposure 
limits set forth for an uncontrolled environment. End user 
must follow the specific operating instructions for 
satisfying RF exposure compliance. This transmitter 
must not be co-located or operating in conjunction with 
any other antenna or transmitter. 
The portable device is designed to meet the 
requirements for 
exposure to radio waves established by the Federal 
Communications 
Commission (USA). These requirements set a SAR limit 
of 1.6 W/kg 
averaged over one gram of tissue. The highest SAR 
value reported under 
this standard during product certification for use when 
properly worn on the body 
 

IC warning statement 

 

This device complies with Industry Canada’s 
license-exempt RSSs. Operation is subject to the 
following two conditions:    (1) This device may not cause 
interference; and    (2) This device must accept any 
interference, including interference that may cause 
undesired operation of the device. 
 
Le présent appareil est conforme aux CNR d'Industrie 
Canada applicables aux appareils radio exempts de 
licence. L'exploitation est autorisée aux deux conditions 
suivantes : (1) l'appareil ne doit pas produire de 
brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage 
est susceptible d'en compromettre le fonctionnement. 
 
This radio transmitter has been approved by Industry 
Canada to operate with the 
antenna types listed below with the maximum 
permissible gain and required 
antenna impedance are strictly prohibited for use with 
this device. 
 
Le present emetteur radio a ete approuve par Industrie 
Canada pour fonctionner 
avec les types d'antenne enumeres ci-dessous et ayant 
un gain admissible maximal 
et l'impedance requise pour chaque type d'antenne. Les 
types d'antenne non inclus 
dans cette liste, ou dont le gain est superieur au gain 
maximal indique, sont 
strictement interdits pour l'exploitation de l'emetteur. 
 
(i)the device for operation in the band 5150–5250 MHz is 
only for indoor use to reduce the potential for harmful 
interference to co-channel mobile satellite systems; (For 
devices installed in vehicles point i. is not required.) 
 
Users should also be advised that high-power radars are 
allocated as primary users (i.e. priority users) of the 
bands 5250-5350 MHz and 5650-5850 MHz and that 
these radars could cause interference and/or damage to 

 


background image

LE-LAN devices.   
 
(i) l'appareil pour fonctionner dans la bande 5150-5250 
MHz est réservé à une utilisation en intérieur afin de 
réduire les risques d'interférences nuisibles à la co-canal 
systèmes mobiles par satellite; 
 
Devraient également être informés les utilisateurs que 
les radars à haute puissance sont désignés comme 
utilisateurs principaux (c.-à-utilisateurs prioritaires) des 
bandes 5250-5350 MHz et 5650-5850 MHz et que ces 
radars pourraient provoquer des interférences et / ou 
endommager les appareils LE-LAN. 
 

IC Radiation Exposure Statement 
 

This EUT is compliance with SAR for general 
population/uncontrolled exposure limits in IC RSS-102. 
This equipment should be installed and operated with 
minimum distance 0 cm between the radiator & your 
body.   
Cet EUT est la conformite avec SAR pour la population 
generale / les limites d'exposition incontrolees dans IC 
RSS-102. Cet equipement doit etre installe et utilise a 
une distance minimale de 0 cm entre le radiateur et votre 
corps. 
 
This equipment complies with ISED radiation exposure 
limits set forth for an uncontrolled environment. End user 
must follow the specific operating instructions for 
satisfying RF exposure compliance. This transmitter 
must not be co-located or operating in conjunction with 
any other antenna or transmitter. 
The portable device is designed to meet the 
requirements for exposure to radio waves established by 
the ISED. These requirements set a SAR limit of 1.6 
W/kg averaged over one gram of tissue. The highest 
SAR value reported under this standard during product 
certification for use when properly worn on the body. 
Cet équipement est conforme aux limites d’exposition 
aux rayonnements ISED établies pour un environnement 
non contrôlé. L’utilisateur final doit suivre les instructions 
spécifiques pour satisfaire les normes. Cet émetteur ne 
doit pas être co-implanté ou fonctionner en conjonction 
avec toute autre antenne ou transmetteur. 
 

 
5.4 ENERGY STAR 

 

An ENERGY STAR qualified computer delivers 
substantial savings over a conventional computer. 
Desktop, integrated desktop, and notebook (laptop) 
computers, workstations, small-scale servers, and thin 
clients are all eligible to earn the ENERGY STAR, and 
those that do are now more efficient than ever. 
It is an honor for Teguar to provide you such products. 
 
What is ENERGY STAR? 
ENERGY STAR is a U.S. Environmental Protection 
Agency (EPA) voluntary program that helps businesses 
and individuals save money and protect our climate 
through superior energy efficiency. 
The ENERGY STAR program was established by EPA in 
1992, under the authority of the Clean Air Act Section 
103(g). Section103(g) of the Clean Air Act directs the 
Administrator to "conduct a basic engineering research 
and technology program to develop, evaluate, and 

demonstrate non–regulatory strategies and technologies 
for reducing air pollution." 
 
In 2005, Congress enacted the Energy Policy Act. 
Section 131 of the Act amends Section 324 (42 USC 
6294) of the Energy Policy and Conservation Act, and 
"established at the Department of Energy and the 
Environmental Protection Agency a voluntary program to 
identify and promote energy–efficient products and 
buildings in order to reduce energy consumption, 
improve energy security, and reduce pollution through 
voluntary labeling of or other forms of communication 
about products and buildings that meet the highest 
energy efficiency standards." 
 
For more information, please visit www.energystar.gov 
 
TMT-4391-08 is to enter display sleep mode after 4 
minutes and computer sleep mode after 10 minutes in 
default. To wake it from sleep mode, simply press the 
power button on the back cover, while under sleep mode 
it allows the device to save 80% or more energy. 
Power Management System: 
Lists of default power management systems 

Balanced 
(Default) 

TMT-4391-08: Idle 4 mins. closes 
screen, 10 min. enters sleep mode. 

High 
performance

 

Never idle and never enters sleep 
mode.

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

Additional Information and 

Assistance 

 
Contact your distributor, sales representative, or Teguar's 
customer service center for technical support if you need 
additional assistance. Please have the following 
information ready before you call: 
 

  Product name and serial number   

 

  Description of your peripheral attachments   

 

  Description of your software (operating system, 

version, application software, etc.)   
 

  A complete description of the problem   

 

  The exact wording of any error messages   

 

  This equipment is a source of electromagnetic waves. 

Before use please, make sure that there are not EMI 
sensitive devices in its surrounding which may 
mal-function therefore.   
 

 

Items highlighted in RED can be referenced in 

separate report. 
 

Environmental protection 

 

  Follow national requirements to dispose of unit.   

 

Manufacturer:

 

Teguar Corporation 
4235 S. Stream Blvd. L-130, Charlotte, NC 28217 
TEL: +1 704-960-1761 
 
Visit the Teguar website at www.Teguar.com if you need 