STANDARD MB 80 STANDARD MB 80 H STANDARD MB 50 PRAKTIK MB 50 PRAKTIK MB 80 PRAKTIK MB 100 PRAKTIK MB 120 PRAKTIK MB 50 INOX PRAKTIK MB 80 INOX PRAKTIK MB 100 INOX PRAKTIK MB 120 INOX PRAKTIK MB PK 80 PRAKTIK MB PK 120 PRAKTIK MB PK 80 INOX PRAKTIK MB PK 120 INOX SLIM MB 30 SLIM MB 50 SLIM MB 80 SLIM MB 30 INOX SLIM MB 50 INOX SLIM MB 80 INOX

Made by: Tedan
Type: Installation, Use And Care Guide
Category: Water Heater
Pages: 11
Size: 0.64 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

INSTRUCTIONS FOR INSTALLATION, USE AND CARE OF WATER HEATERS

STANDARD MB 30, 50, 80 lit. STANDARD MB 80 H,

PRAKTIK MB 50, 80, 100, 120 lit. PRAKTIK MB 50, 80, 100, 120 lit. Inox

PRAKTIK MB PK 80,120 lit. PRAKTIK MB PK 80, 120 lit. Inox

SLIM MB 30, 50, 80 lit. SLIM MB 30, 50, 80 lit. Inox

 


background image

2

EN

CONTENTS

Technical information.....................................................................3

Installation......................................................................................4

Connection to water supply............................................................8

Connection to power supply...........................................................9

Use, control and maintenace of electrical water heaters.............10

Waste disposal ............................................................................11

 


background image

3

EN

pic.1

1. Housing

2. Polyurethane insulation

3. Heating tank (enamelled)

4. Screw, seal, nut, washer

5. Heater with seal

6. Flange

7. Flange sealing rubber

8. Counter-flange

9. Thermoregulator

10. Mg-anode

11. Connection tube for water

12. Rings

13. Connection tube for hot water 

output 

14. Signal lamp

15. Thermoregulator button

16. Thermometer

17. Support for hanging to wall

18. Screws for support

TECHNICAL INFORMATION
Electrical accumulation water heaters are designed to work with pressure of 
the water supply pipeline. The appliance is not meant for persons (including 
children) of reduced psychophysical abilities, unless under supervision of 
persons responsable for their safety, i.e. for persons not skilled for use of the 
appliance. Improper use of the appliance, especially from the side of children, 
should be prevented.

Water heaters are made according to valid standards and tested and certified by 

authorized laboratory. Product technical characteristics are given on the sticker 
„Table with Characteristics“ between connection pipes.

Picture 1 shows design of the water heater with all parts

 


background image

4

EN

INSTALLATION
Only authorized persons are allowed to perform installation / connection of water 

heaters to water and power supplies. All types of water heaters are fixed to the 

wall by 2 or 4 screws of 8 mm minimum diameter. Thin and delicate walls should 
be reinforced prior to water heater installation

Technical characteristics of accumulation water heater:

Model

Standard MB 30

Standard MB 50

Standard MB 80

Capacity (litres)

30

50

80

Weight when full of 

water (kg)

0.6

0.6

0.6

Weight when full of 

water (kg)

17/47

22/72

29/109

Corrosion 

protection

type

Enamelled Mg

anode

Enamelled Mg

anode

Enamelled Mg

anode

Heater power (W)

2000

2000

2000

Voltage

230

230

230

Time of water 

heating from 15°C 

to 75°C

1

05

1

55

3

05

Model

Praktik MB 80

Praktik MB 100

Praktik MB 120

Capacity (litres)

80

100

120

Weight when full of 

water (kg)

0.6

0.6

0.6

Weight when full of 

water (kg)

28/108

32/132

36/156

Corrosion 

protection

type

Enamelled Mg

anode

Enamelled Mg

anode

Enamelled Mg

anode

Heater power (W)

2000

2000

2000

Voltage

230

230

230

Time of water 

heating from 15°C 

to 75°C

2

55

3

50

4

35

 


background image

5

EN

Model

Praktik MB 

50 INOX

Praktik MB 

80 INOX

Praktik MB 

100 INOX

Praktik MB 

120 INOX

Capacity (litres)

50

80

100

120

Weight when full of 

water (kg)

0.6

0.6

0.6

0.6

Weight when full of 

water (kg)

18/68

22/102

25/125

28/148

Corrosion 

protection

type

INOX

Mg anode

INOX

Mg anode

INOX

Mg anode

INOX

Mg anode

Heater power (W)

2000

2000

2000

2000

Voltage

230

230

230

Time of water 

heating from 15°C 

to 75°C

1

50

2

55

3

50

4

35

Model

Standart MB 

80 H

Capacity (litres)

80

Weight when full of 

water (kg)

0.6

Weight when full of 

water (kg)

29/109

Corrosion 

protection

type

Enamelled

Mg anode

Heater power (W)

2000

Voltage

230

Time of water 

heating from 15°C 

to 75°C

3

20

The tank is insulated with quality polyurethane insulation providing that water stays hot 

for long. Enamelled tanks are extra protected from corrosion by the magnesium anode. 

Water from enamelled and stainless steel tanks is physiologically pure and therefore 
usable also for food preparation.

Model

KlassA MB 80 

/ MB 80 SG

Capacity (litres)

80

Weight when full of 

water (kg)

0.6

Weight when full of 

water (kg)

29/109

Corrosion 

protection

type

Enamelled Mg

anode

Heater power (W)

2000

Voltage

230

Time of water 

heating from 15°C 

to 75°C

4

15

 


background image

6

EN

NNU

NNM

QUO

OOTI

O

b

j

G½" (

G¾")

Модел

STANDARD MB 30

PRKTIK MB 50

PRKTIK MB 120

SLIM MB 80

STANDARD MB 50

PRKTIK MB 80

SLIM MB 30

MB STANDARD 80 

PRKTIK MB 100

SLIM MB 50

A

(mm)

C

(mm)

E

(mm)

M

(mm)

504

591

1091

1135

190

192

192

182

415

81

480

110

480

110

390

116

704

811

535

190

192

182

415

81

480

110

390

116

1004

951

785

190

192

182

415

81

480

110

390

116

B

(mm)

0

(mm)

L

(mm)

N

(mm)

293

384

884

953

395

454

454

354

100

130-360

100

130-360

600

130-360

730

240-300

493

604

303

395

454

354

300

130-360

320

130-360

130

240-300

793

744

603

395

454

354

600

130-360

460

130-360

380

240-300

KLASSA MB 50 SG

KLASSA MB 80 

KLASSA MB 80 SG

KLASSA MB 50 

604

860

219

219

480

110

480

110

860

219

480

110

640

219

480

110

395

615

454

454

100

130-360

100

130-360

615

454

320

130-360

395

454

100

130-360

Connection and installation measures:

Model PRAKTIK

Enameled water tank:

MB PKL 80; MB PKD 

80;

MB PKL 120; MB PKD 

120;

Stainless steel water 

tank:

MB PKL 80 RFI; MB 

PKD 80 FI;

MB PKL 120 FI; MB 

PKD 120 FI;

Heat exchanger

surface (m2)

0.25

0.3

Heat exchanger

connectors

G

3

/

4

G

1

/

2

Heating fluid

max. pressure (MPa)

0.6

0.6

Heating fluid

max. temperature (°C)

90

90

 


background image

7

EN

A (mm) B (mm)

C (mm)

Ф (mm)

E (mm)

L (mm)

STANDARD MB 80 H

1004

204

190

395

415

610

Left water heater MB 80 HL

Right water heater MB 80 HD

Horisontal water heaters could be mounted as left or right depending on the position of the 
thermoregulator, and this models are designed to be mounted only on wall (not ceiling ) , 

so pipes are toward floor.

 


background image

8

EN

Input of cold water for electrical water heater is marked with blue ring, while hot water output 
is marked with red ring, which is to be respected when connecting water heater to water 
supply. Accumulation heater works under preassure (closed system) and it is possible to use 
water at more than one point in the house.

The fittigns/mixing pipes appropriate for work under pressure have to be used with this water 

heater.
On each accumulation water heater there have to be mounted a safety valve (see Picture 3) 

to keep pressure in the tank from exceeding the limit. Such safety valve should be checked 

every two weeks. By moving the lever or unscrewing the nut (depending on valve type) 

exceeding water from return safety valve should come out meaning the valve is working 

correctly. Non-return valve prevents tank to empty in case of pressure fall in water supply 
pipeline. If regular water pressure in the pipeline is higher than 0,6 Mpa (6 bar) a reduction 
valve has to be mounted on the cold water inlet connection.

CONNECTION TO WATER SUPPLY

1. Safety valve

2. Test valve

3. Non-return valve

4. Reduction valve

5. Interlocking valve

CW cold water

HW hot water   

An interlocking must not come between the safety valve and the water heater, as it would 
disable safety valve function. Fill the water heater with water before connecting it to electric 

power supply. During the filling operation open the hot water pipe. When water starts coming 

out the hot water pipe the water heater is full.If hot water is used on more than one spot in the 
house it is recomandable to make internal pipeline as short as possible so that heat losses 
are minimum.

The water heaters with heat exchanger are connected to water supply in the same way like 
regular water heaters. Water heaters with heat exchanger are ment for connection to other 

energy sources (centralized heating system, solar heating and heat punps). Entrance point 

of heated media to the heat exchanger is marked with red, while exit
is marked with blue. Water heating with electrical heater and heat exchanger could function 
contemporary or separately. Water heaters with heat exchanger are not designed for central 
heating systems which fluid temperature exceeds 110°C. Due water heating, water pressure 

in water heater increas up to safety valve set limit, and water drops come out the valve. The 
drip can be piped to the drain by installing a catching unit just below the

safety valve.In case the existing plumbing does not enable you to pipe the dripping water 

 


background image

9

EN

from the return safety valve into the drain, you can avoid the dripping by installing a 3-litre 

expansion tank on the inlet water pipe of the boiler.
Water may come out in drops from the exhaust pipe of pressure reduction device i.e, safety 

valve, this pipe has to be open and positioned downwise, to prevent freezing of the water in 
the pipe. By regular function of the safety valve it should be possible to remove
limescale sediment as well as to check if it is bloacked. Safety valve is delivered with the 
water heater and the sheme shows how to install it. At installation of a water heater and its 
connection to water supply, it is recomanded to use new set of hoses, old ones should not 
be used. 
CONNECTION TO POVER SUPPLY
Electric accumulation water heater is connected to power supply by valid standards for 

electrical installations, with a plug cable 3x1,5 mm H05VV.

Before connecting power supply cable, unscrew the two screws and remove protection cap 
of the electric water heater. The electric water heater is not delivered with a device to cut off 
the power from the supply permanently. A separating element of all the poles from the supply 
should be included, according to local installation rules. Such separating means have to be 
included in the electrical installation.

1. Thermoregulator

2. Heater

3. Connection clamp

4. Signal lamp

L – phase

N neutral

Ground  

WARNING

: Before any intervention the water heater must be disconnected

from the power supply line.

USE, CONTROL, MAINTENANCE OF ELECTRIC WATER HEATERS

After connecting it to water and power supplies the water heater is ready to use. For types 

without external heater regulation (no button on the cover), water temperature is regulated 

by a preset thermoregulator. It is recomanded not to change the set temperature (t=55°C)
being optimal for saving energy and minimum limestone sedimentation. Should the user 

however want to change the temperature of water heating, the water heater should first be 

disconnected from power supply line, protection cap on the bottom should be taken off, and 
by turning plastic button directly on the thermoregulator, water heating temperature can be 
set to be lower or higher within the range 20 to 70±5°C.

 


background image

10

EN

For water heater types with external regulation, by simple turning the button desired 

water heating temperature can be set within the range 20 to 70±5°C. When desired/ set 
temperature is reached inside the the tank the thermoregulator will cut the power circuit 
automatically, and the signal lamp which has been on during the heating time,
will go off. 

WARNING

: before using hot water from water heater turn it off from elecrical power 

supply.

Water heaters also have thermometers with metal cap and bimetal showing the temperature 
of the water. If water heater will not be used for longer period it is recomanded to disconnect 
it from power supply line. If water inside the water heater could freeze while not used it 
is recomanded to empty the tank. The miantenance tips should be respected, especially 
check-up for how much Mg anode is consumed, at least every 36 months, and replace it if 
needed. The limestone sediment should be removed regularly.
For such interventions tank must be emptied.
To empty the tank please proceed as follows:
- Disconnect the water heater from power supply
- Close the inlet cold water valve
- Open the hot water pipe
- Unscrew the safety valve mounted on the cold water inlet, and wait
for water to go out.

After that the unscrew the nut of the heater counterflange, take out the flange with the heater, 

remove the limescale and replace Mganode. If you use chemical products for limescale 
removal, they must not come into contact with Mg-anode (anode should be taken out). 

Afterwards the tank should be rinsed and refilled with water.

WASTE DISPOSAL – WHAT AFTER YOUR WATER HEATER IS

NO MORE USABLE

The accumulation water heaters and the packing are made of recyclable 

materials. After your water heater is not usable any more, it is forbidden 

to dispose it as non-selected waste. For waste disposal, the water heater 

plactic and rubber parts should be separated from metal parts, classified 

and left for recycling or

final disposal according to loacal regulations.Only by waste separation and 

management you will protect the environment.

 


background image

България, 1592 София

бул. Проф. Цветан Лазаров 50

Нац. телефон: 0700 19889

e-mail: office@tedanbg.com