U S E R   I N S T R U C T I O N S  

 

 


background image

 

 

IU_BasicLine_01_eng 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

T6530/DL 

 

 

T8530 

 

EM35•20 Technical Manual 

CHARACTERISTICS

 

The  StraightBolt  lock  can  be  mounted  in  all  four  mounting  directions.    The  Basic  Electronics 

feature a 6-digit Main code that can be changed by the user.   With the main code a secondary 

code can be activated and deleted.  If a valid code has been entered, the lock electronic removes 

the  blocking  for  3  seconds  and  the  bolt  can  be  moved  into  the  housing  by  turning  an  internal 

driving cam with a turnable entry unit or a knob.  After moving the bolt to LOCKED position, the 

StraightBolt automatically secures. 

 

ENTRY UNITS 

The StraightBolt is compatible with the following NL LOCK Entry units (separate technical 

descriptions for Entry units are available). Entry unit spindle/cable hole on the safe door does not 

have to exceed 12 mm diameter 

EM35•20 Technical Manual rev. 160223 

 

 

© 2016 Lock Technology  Page 

!

 of 

!

1

2

Delta Series: DE20

Bravo: BR50

Premier: PI20  

(with separate knob)

!

DE20-10 Technical Manual 

CHARACTERISTICS

The Delta is a low profile electronic entry  with “soft touch“ rubber keypad and metal 
ring  to  be  mounted  with  StraightBolt  lock.  Cable  length  is   approximately  30  cm. 
Additional battery box is required (sold separately).

DIMENSIONS / MOUNTING INSTRUCTION

The  diameter of  the cable hole  should  be  minimum 9  mm,  maximum 12  mm.  The 
hole must be de-burred well to avoid damage to the cable.
Drill and tap door according to picture 1 drawing for the mounting plate

Fit the mounting plate (1) on door 
using the 2x M4 mushroom-head 
supplied screws (2) with "UP TO 
ROTATE" oriented upwards 

Cut spindle (5) length to exceed 
8-10 mm lock mounting surface

Insert spindle in keypad so that 
cable runs in the spindle groove.  

Fit spring (4) and detent pin (3) 
into the hole on the rear of the 
keypad

Route the spindle through the 
cable/spindle hole and move the 
unit to the mounting adapters. 
Rotate keypad 35-40° CCW until keypad can be fixed on the screw heads and 
then rotate CW to straight up. Proceed with installing the lock.

The Delta entry unit can now not be removed!

 

DE20•10 Technical Manual rev. 110128

 

 

 

© 2011 Lock Technology BV  Page 1 of 1

Delta

StraightBolt

Bolt work requirements 
Lock bolt operations only allowed as described 
into the drawing and max load should not 
exceed 1KN.

Important:  

Modifications to the lock (including lock bolt attachments) are not 
allowed, and will void the manufacturer’s warranty and Standards 
approvals. 

No through holes on the safe door are allowed within the lock body area beside 
the spindle/cable hole. 

Lock body area should be protected against destructive attacks

 

DE20xx 

 

 

EM35•20 Technical Manual 

CHARACTERISTICS

 

The  StraightBolt  lock  can  be  mounted  in  all  four  mounting  directions.    The  Basic  Electronics 

feature a 6-digit Main code that can be changed by the user.   With the main code a secondary 

code can be activated and deleted.  If a valid code has been entered, the lock electronic removes 

the  blocking  for  3  seconds  and  the  bolt  can  be  moved  into  the  housing  by  turning  an  internal 

driving cam with a turnable entry unit or a knob.  After moving the bolt to LOCKED position, the 

StraightBolt automatically secures. 

 

ENTRY UNITS 

The StraightBolt is compatible with the following NL LOCK Entry units (separate technical 

descriptions for Entry units are available). Entry unit spindle/cable hole on the safe door does not 

have to exceed 12 mm diameter 

EM35•20 Technical Manual rev. 160223 

 

 

© 2016 Lock Technology  Page 

!

 of 

!

1

2

Delta Series: DE20

Bravo: BR50

Premier: PI20  

(with separate knob)

!

DE20-10 Technical Manual 

CHARACTERISTICS

The Delta is a low profile electronic entry  with “soft touch“ rubber keypad and metal 
ring  to  be  mounted  with  StraightBolt  lock.  Cable  length  is   approximately  30  cm. 
Additional battery box is required (sold separately).

DIMENSIONS / MOUNTING INSTRUCTION

The  diameter of  the cable hole  should  be  minimum 9  mm,  maximum 12  mm.  The 
hole must be de-burred well to avoid damage to the cable.
Drill and tap door according to picture 1 drawing for the mounting plate

Fit the mounting plate (1) on door 
using the 2x M4 mushroom-head 
supplied screws (2) with "UP TO 
ROTATE" oriented upwards 

Cut spindle (5) length to exceed 
8-10 mm lock mounting surface

Insert spindle in keypad so that 
cable runs in the spindle groove.  

Fit spring (4) and detent pin (3) 
into the hole on the rear of the 
keypad

Route the spindle through the 
cable/spindle hole and move the 
unit to the mounting adapters. 
Rotate keypad 35-40° CCW until keypad can be fixed on the screw heads and 
then rotate CW to straight up. Proceed with installing the lock.

The Delta entry unit can now not be removed!

 

DE20•10 Technical Manual rev. 110128

 

 

 

© 2011 Lock Technology BV  Page 1 of 1

Delta

StraightBolt

Bolt work requirements 
Lock bolt operations only allowed as described 
into the drawing and max load should not 
exceed 1KN.

Important:  

Modifications to the lock (including lock bolt attachments) are not 
allowed, and will void the manufacturer’s warranty and Standards 
approvals. 

No through holes on the safe door are allowed within the lock body area beside 
the spindle/cable hole. 

Lock body area should be protected against destructive attacks

 

Br50xx 

 

 

ST40xx 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

EM2050/A 

 

EM3550/A 

 

EM3550/A/S (not VdS) 

 

 

 

 


background image

 

 

IU_BasicLine_01_eng 

 

                                    

LOCK FEATURES 

 

Codes 

 

One  Manager

:  can  open,  changes  his  code,  manage  users,  program  time  delay,  audit 

users and lock. 

User

: can open and change their own codes. 

New codes are rejected when less than 2 digits are different from existing codes. 

 

Time Delay 

Time delay programmable from 0 (no time delay) to 99 minutes. Open window from 1 to 19 
minutes.  
During time delay enabled LED flashes at two seconds intervals. Open window is indicated 
by LED then buzzer at 1 seconds intervals alternately (once LED, once beep). 

 

Battery low warning 

If battery low (<6V) during motor activation, multiple beeps. 

 

Time penalty 

When entering code, a time penalty of 5 minutes will be started after the 4th consecutive 
wrong code entered. During time penalty, LED flashes at 10s interval, no access possible 
to lock. 
Any key pressed during time penalty emits a long beep. 
After time penalty, two consecutive wrong codes will start it again. 

 

Additional features 

 

TD override user #9 – When TD active, user #9 always override TD in “dual mode”. 
Basic Input/Output features – If standard I/O is activated, silent alarm (+1 on combination 
last digit will trigger an alarm output signal) and disable input features are active through 
additional 4-wires on-board connector. 

 

Recommandations 

  It is strongly recommended to immediately change the factory codes 

  For security reasons, do not chose codes which could be easy to guess (e.g. 1 2 3 

4 5 6) 

  For your new code, do not use any personal data like birthdays or any other data, 

that could be derived by knowledge of your person. 

  After code changing, the lock must be tested several times with door in open state. 

  Do not open the lock case, otherwise you compromise the function of the lock and 

warranty will be void. 

  In  order  to  prevent  any  possibility  that  the  code  become  public  or  known  by 

unauthorized  persons  we  strongly  recommend  to  store  any  data  and/or  code  in  a 
safety place, where only its rightful owner can access. 

 

 

 


background image

 

 

IU_BasicLine_01_eng 

 

USERS INSTRUCTIONS

         

 

 

Open

  

 

  Enter a six digits valid code (factory code 1-2-3-4-5-6). 

o

  A valid code is followed by a double signal. 

o

  An invalid code is followed by a long signal. 

  If time delay is not active open the door. 

  If time delay is active the counting starts (during time delay counting the light flashes 

every  2  seconds).  When  time  delay  elapses,  open  window  counting  starts  (during 
open window counting the buzzer beeps every 2 seconds). Enter the code again and 
open the door. 

  Note: If the door is not opened within 3 (three) seconds, the lock secures 

automatically. 

 

 

Manipulation protection 

 

  The  entry  of  4  (four)  consecutives  invalid  codes,  will  cause  a  5  (five)  minutes  lock 

blocking. During this period, the light flashes every 10 seconds and any key pressed 
will produce a long signal. After expiration, the entry of 2 (two) more invalid codes, 
will restart the 5 minutes blocking period. 

 

 

Change code

  

 

!

 

Press and hold

 key “0” until double signal. 

!

 

Enter the old code (double signal). 

!

 

Enter the new code (double signal). 

!

 

Repeat the new code (double signal). 

 

 

 

 

Note: In case of errors (long signal) the old code remains valid. 
 

 

Always perform this operation with the door opened. 

 
Test lock operation several times before closing the door. 

 

Add the user

  

 

!

 

Press and hold

 key “1” until double signal; 

the  light  remains  switched  on  during  the 
following actions. 

!

 

Enter the main code. 

!

 

Enter the new opening code (double signal). 

!

 

Confirm  the  new  opening  code  (double 

signal). 

 

 

 

Note: If the lock features only two codes there will not be the need to select a position for 

the new user. 

 


background image

 

 

IU_BasicLine_01_eng 

 

 

Delete the user

  

 

!

 

Press and hold

 key “3” until double signal; 

the  light  remains  switched  on  during  the 

following actions. 

!

 

Enter the main code. 

 

 

!

 

The user is now deleted. 

 

Membrane check-up

  

 

!

 

Press and hold

 key “5” until double signal. 

!

 

Enter the following sequence of numbers:  

     1-2-3-4-5-6-7-8-9-0. 

 

 

o

 

Double signal = key correctly working. 

o

 

Long signal = key not working. 

 

Set time delay

  

 

!

 

Press and hold

 key “9” until double signal; 

the  light  remains  switched  on  during  the 

following actions. 

!

 

Enter the main code. 

 

 

!

 

Enter time delay value (2 digits, from 00 to 99 minutes) and open window value (2 

digits, from 01 to 19 minutes) (double signal).   

o

 

For instance if you want to program 26 minutes delay and 12 minutes open 

window, enter: “2612”. 

!

 

Confirm time delay value and open window value (double signal).     

 

Note: Time delay value can be increased in every moment; to decrease it, lock must be in 

open window. 

 

Battery change 

 

A series of signals during opening indicates that the battery is weak and must be replaced. 
Only use fresh 9V-ALKALINE batteries from brand name manifacturers like DURACELL

TM

 

 
 

 


background image

 

IU_BasicLine_01_eng 

 

 

Before operating the unit, 

please read this manual thoroughly, 

and retain it for future reference. 

 
 

 

 
 

 

 
 

 

 

Correct disposal of this product:  

(Waste Electrical & Electronic Equipment) 
 

Applicable  in  the  European  Union  and  other  European  countries  with  separate 
collection systems. 

 

This marking shown on the product or its literature indicates that it 
should not be disposed with other wastes at the end of its working 

life.  To  prevent  possible  harm  to  the  environment  or  human  health 

from  uncontrolled  waste  disposal,  please  separate  this  from  other 
types of wastes and recycle it responsibly to promote the sustainable 

reuse of material resources.  

 

 

 

 
 

 

 
 

 

 
 

 

 

 

 

Certified  ISO 9001 : 2000 

 

TECNOSICUREZZA s.r.l. 

Via Cesare Battisti, 276 – 37057 S. Giovanni Lupatoto (VR) – Italy 

Tel. +39 045 826 64 70  -  Fax +39 045 826 64 69 

mail: 

info@tecnosicurezza.it

  -  web: 

www.tecnosicurezza.it