background image

Blast Chillers

Instruction manual

BK+5   BK+10   BK+15

EasyChill
ChillRapid
SurRapid

 


background image

Gentile Cliente,
La ringraziamo per aver preferito uno dei
nostri prodotti, frutto di lunga esperienza
e di una continua ricerca per un prodotto
superiore in termini di affidabilità,
prestazioni e sicurezza.
In questo manuale troverà tutte le
informazioni ed i consigli per poter
utilizzare il suo prodotto nel massimo
della sicurezza ed efficienza.

Dear Customer,
We would like to thank you for having
chosen our products, the result of long
experience and continuous research for a
superior product in terms of reliability,
performance and safety.
This manual will supply all of the
information and advice for the efficient
use of your product in complete safety.

Cher Client,
Nous vous remercions d’avoir choisi notre
produit, fruit d’une longue expérience et
d’une recherche permanente d’un produit
supérieur en termes de fiabilité, de
prestations et de sécurité.
Dans ce manuel vous trouverez toutes les
informations et les conseils pour pouvoir
utiliser votre produit avec une sécurité et
une efficacité optimales.

Sehr geehrter Kunde!
Wir danken Ihnen für Ihre Wahl eines
unserer Produkte, welches das Ergebnis
einer langen Erfahrung und stetiger
Forschungsarbeit ist. Dank dieser konnte
ein Produkt entwickelt werden, das ein
hohes Maß an Verlässlichkeit,
Leistungsfähigkeit und Sicherheit bietet.
In diesem Handbuch finden Sie sämtliche
Informationen und Ratschläge, damit Sie
das Produkt mit maximaler Sicherheit und
Effizienz nutzen können.

Estimado cliente:
Le agradecemos por elegir nuestros
productos, fruto de la gran experiencia y
de la investigación constante para
obtener un producto superior en
términos de fiabilidad, rendimientos y
seguridad.
En este manual, encontrará todos los
datos y consejos para poder utilizar el
producto en sus máximos niveles de
seguridad y eficiencia.

 


background image

L’apparecchio contiene gas fluorurati ad ef

fetto serra disciplinati dal pro

tocollo di Kyoto

The equipment contains greenhouse ef

fect fluoride gas governed by 

the Kyoto protocol

L’appareil contient des gaz fluorés à ef

fet de serre règlementés par le

 protocole de Kyoto

Das Gerät enthält fluorierte 

Treibhausgase durch das Kyoto-Protokoll 

fallen

El aparato contiene gases fluorados de efecto inver

nadero regulados por el protocolo de Kioto

REGOLA

MENT

O (UE) 2015/1095

REGULA

TION (EU) 2015/1095

RÈGLEMENT (UE) 2015/1095

VER

ORDNUNG (EU) 2015/1095

REGLA

MENT

O (UE) 2015/1095

REGULA

MENT

O (UE) 2015/1095

РЕГ

ЛАМЕНТ (ЕС) 2015/1095

NAŘÍZENÍ K

OMISE (EU) 2015/1095 

KOMMISSIONENS FOR

ORDNING (EU) 2015/1095

KOMISJONI M

ÄÄRUS (EL) 2015/1095

ΚΑΝΟΝΙΣΜΟΣ (ΕΕ) 2015/1095 

ΤΗΣ ΕΠΙΤΡΟΠΗΣ

UREDBA K

OMISIJE (EU) 2015/1095

KOMISIJAS REGULA (ES) 2015/1095

KOMISIJOS REGLA

MENT

AS (ES) 2015/1095

A BIZ

O

TT

G (EU) 2015/1095 RENDELE

TE

REGOLA

MENT 

TAL

-KUMMISSJONI (UE) 2015/1095 

VER

ORDENING (EU) 2015/1095 

VAN DE C

OMMISSIE 

ROZPORZĄDZENIE K

OMISJI (UE) 2015/1095

REGULA

MENTUL (UE) 2015/1095 AL C

OMISIEI

NARIADENIE K

OMISIE (EÚ) 2015/1095 

UREDBA K

OMISIJE (EU) 2015/1095 

KOMISSION ASE

TUS (EU) 2015/1095, 

KOMMISSIONENS FÖR

ORDNING (EU) 2015/1095

Modello Models Modèles Modelle Modelos

Alimentazione Power supply

Source de courant Energieversorgung Fuente de alimen

-

tación

Refrigerante Refrigerant Fluide frigorigène Kühlgas Fluido refrige

-

rante

Carica refrigerante  Refrigerant charge

frigorigène

Kältemittelfüllung

Carga de refrigerante

(Kg)

GWP

Ciclo

 Abbattimento Posi

tivo - Chilling Cycle - Cycle Chilling

Kühlzyklus - Ciclo de enfriamiento

Ciclo

 Abbattimento Negativo - Freezing Cycle - Cycle de Congélation - 

Gefrierzyklus - Ciclo de congelación

Ciclo temperat.

Temp. Cycle Cycle de temp.

Temperaturzyklus Ciclo de temperat.

(°C)

Capacità Capacity Capacité Kapazität Capacidad

(Kg)

Durata ciclo Cycle time

Temps de  cycle

Taktzeit

Tiempo de ciclo

(min)

Consumo Energia Energy Consumpt. Conso. Energie Energieverbrauch Cons. de energía

(kWh/Kg)

Ciclo temperat. T

emp. Cycle

Cycle de temp.

Temperaturzyklus Ciclo de temperat.

(°C)

Capacità Capacity Capacité Kapazität Capacidad

(Kg)

Durata ciclo Cycle time

Temps de  cycle

Taktzeit

Tiempo de ciclo

(min)

Consumo Energia Energy Consumpt. Conso. Energie Energieverbrauch Cons. de energía

(kWh/Kg)

BK+ 5.16

A

220-240V/50Hz

R404A

1,10

3922

+65° / +10°

18,4

103

0,098

+65° / -18°

13,8

266

0,337

BK+ 5.16

W

220-240V/50Hz

R404A

1,10

3922

+65° / +10°

18,4

103

0,098

+65° / -18°

13,8

266

0,337

BK+ 10.30

A

220-240V/50Hz

R404A

2,40

3922

+65° / +10°

33,6

98

0,091

+65° / -18°

23,0

265

0,361

BK+ 10.30

W

220-240V/50Hz

R404A

2,00

3922

+65° / +10°

33,6

98

0,091

+65° / -18°

23,0

265

0,361

BK+ 15.40

A

400V/3N/50Hz

R404A

2,20

3922

+65° / +10°

41,4

102

0,100

+65° / -18°

27,6

258

0,379

BK+ 15.40

W

400V/3N/50Hz

R404A

2,20

3922

+65° / +10°

41,4

102

0,100

+65° / -18°

27,6

258

0,379

 


background image

BLAST CHILLER ISTRUCTION

      BUTTONS AND LEDS

q

w

e

r

t

y

u

q

w

e

r

t

y

u

i

o

a

s

d

f

Start/Stop

Cycle status

Soft/hard positive blast chilling button (+3°c) 

Blast freezing button (-18°c)/ice cream cycle

Blast chilling mode

Decrease value key

Increase value key

STATUS ICONS

Door alarm LED

Timed cycle LED (yellow)

Temperature cycle LED (yellow)

Positive blast chilling cycle LED (green)

Hard blast chilling cycle LED (yellow)

Blast freezing cycle LED (green)

Storage cycle LED (green)

Defrosting phase LED (green)

High pressure alarm LED (red)

Minutes LED (red)

Temperature scale LED (blue)

Cell sensor alarm LED

Evaporator sensor alarm LED

q

u

y

t

r

e

w

 


background image

      PREFACE

• This manual is an integral part of the pro-

duct, providing all the information required
to ensure correct installation, operation and
maintenance of the machine.

Read the manual carefully,

making refe-

rence to it for machine operation. Keep the
manual in a safe place where it can be ac-
cessed by all authorised operators (instal-
lers, operators and service personnel).

• Installation  must  be  performed  in  com-

pliance with National and Local Standards,
by professionally qualified staff and accor-
ding to the manufacturer's instructions.

• Any contractual and extra-contractual lia-

bility of the manufacturer is excluded due
to damage caused by errors during instal-
lation and use and, however, failure to com-
ply with the National and Local Standards
in force and the instructions supplied by
the manufacturer.

• Make  sure  that  the  supplied  or  specified

components are used.

• Before performing any cleaning or mainte-

nance operation, disconnect the appliance
from the electric power supply mains by
operating on the system switch and/or the
product switch.

In the event of faults and/or bad functio-
ning, deactivate the appliance and do not
attempt any repairs or direct intervention.

      CAUTION

THE FOLLOWING OPERATIONS 
AND THOSE HIGHLIGHTED 
BY THIS SYMBOL MUST NOT BE 
PERFORMED BY THE APPLIANCE USER 

In particular:

Electrical connections

Water connections

Installation

Testing

Repairing machine components

Disassembly of the appliance
and/or its components

Adjustments and calibration

Cleaning the appliance and maintenance of:
-  Electrical parts,
-  Electronic parts,
-  Mechanical parts,
-  Refrigeration system parts

THE TExT WITH THIS SYMBOL
IS OF PARTICULAR IMPORTANCE
OR POTENTIAL DANGER SIGNALS

NOTA clarifies the current operations

i

 


background image

English

1

BLAST CHILLER ISTRUCTION

1.

GENERAL DOCUMENTATION

1.1     GENERAL INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.2     INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.3     TRANSPORTATION AND MOVING  . . . . . . . . . . . . . . . . . .2

1.4     UNPACKING – DISPOSAL OF PACKAGING  . . . . . . . . . .2

1.5     SAFETy STANDARDS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.

INSTALLATION

2.1     PLATE DATA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.2     NOTIFICATION OF MALFUNCTION  . . . . . . . . . . . . . . . . .3

2.3     POSITIONING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.4     ROOM TEMPERATURE AND VENTILATION  . . . . . . . . . .3

2.5     ELECTRICAL CONNECTION  . . . . . . . . . . . . . . . . . . . . . . . .3

2.5.1  Connecting the equipment to the mains  . . . . . . . . . . .3

2.6     REMOTE REFRIGERATOR UNIT CONNECTION . . . . . . .4

2.7     DRAIN CONNECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.8     NOTES FOR THE INSTALLER  . . . . . . . . . . . . . . . . . . . . . . . .4

2.9     SAFETy AND INSPECTION SySTEMS  . . . . . . . . . . . . . . .4

2.10   DISPOSAL OF THE MACHINE  . . . . . . . . . . . . . . . . . . . . . . .4

3.

RECOMMENDATIONS FOR PROPER OPERATION

3.1     SHUTDOWN METHODS  . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.2     RECOMMENDATIONS FOR USE . . . . . . . . . . . . . . . . . . . . .5

3.2.1  Pre-chilling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.2.2  Loading the machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4.

PROGRAMMING AND OPERATING INSTRUCTIONS

4.1     MACHINE STARTUP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.2     SETTING THE DATE AND TIME  . . . . . . . . . . . . . . . . . . . . . .6

4.3     OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.3.1  Selecting positive blast chilling timed cycle  . . . . . . . . .6

4.3.2  Selecting positive blast chilling temperature cycle  . .6

4.3.3  Selecting positive hard blast chilling timed cycle . . . .7

4.3.4  Selecting positive hard blast chilling 

          temperature cycle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4.3.5  Selecting freezing timed cycle  . . . . . . . . . . . . . . . . . . . . . .7

4.3.6  Selecting freezing temperature cycle  . . . . . . . . . . . . . . .7

4.3.7  Quick selection of positive blast chilling 

          indefinite timed cycle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4.3.8  Selecting ice cream hardening / 

          freezing indefinite timed cycle . . . . . . . . . . . . . . . . . . . . . .8

4.4     DRyING CyCLE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4.5     RAPID DISPLAy OF TIME 

          AND TEMPERATURE VALUES  . . . . . . . . . . . . . . . . . . . . . . .8

4.6     SANITIzING CyCLE (OPTIONAL)  . . . . . . . . . . . . . . . . . . . .8

PARAMETERS

5.1     PARAMETER MODIFICATION ACCESS  . . . . . . . . . . . . . .9

5.2     PARAMETER LIST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

5.3     DEFROSTING MANAGEMENT  . . . . . . . . . . . . . . . . . . . . . .9

5.4     USB DATA RECORDER (OPTIONAL)  . . . . . . . . . . . . . . . . .9

6.

GREAT TECHNOLOGY AND PROCESS VALUE

6.1     "SOFT" BLAST CHILLING  . . . . . . . . . . . . . . . . . . . . . . . . . .10

6.2     "HARD" BLAST CHILLING . . . . . . . . . . . . . . . . . . . . . . . . . .10

6.3     QUICK FREEzING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

7.

ALARMS LIST 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

8.

ORDINARY MAINTENANCE

8.1     ELEMENTARy SAFETy STANDARDS  . . . . . . . . . . . . . . .12

8.2     CONDENSER CLEANING  . . . . . . . . . . . . . . . . . . . . . . . . . .12

8.3      CELL CLEANING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

8.4     ExTERNAL MAINTENANCE AND CLEANING . . . . . . .12

8.5     DEFROST WATER DRAINING  . . . . . . . . . . . . . . . . . . . . . .13

Description

Page

Description

Page

      INDEX

 


background image

English

2

BLAST CHILLER ISTRUCTION

1. GENERAL DOCUMENTATION

1.1

GENERAL INFORMATION

This manual is an integral part of the product, providing all
the information required to ensure correct installation, ope-
ration and maintenance of the machine. 

Read the manual carefully, making reference to it for machine
operation. Keep the manual in a safe place where it can be
accessed by all authorised operators (installers, operators and
service personnel). 
The machine has been constructed in compliance with the
directives 73/23/CEE (low-voltage), 89/336/CEE (electroma-
gnetic compatibility) and 98/37/CE (machines; for certain
models only). 

The machine has been designed for professional applications
only and should only be operated by qualified personnel. 

The machine must only be used for the purposes for which
it was designed, i.e. for chilling and freezing food products. 
The machine must not be used for products requiring con-
stant temperature control and recording, such as:
- heat-sensitive chemicals, 
- medicines or 
- blood products. 

The manufacturer declines all responsibility for any damage
caused by incorrect or unreasonable machine use, such as: 
- improper use by untrained persons; 
- technical modifications or operations not suited to specific
models; 
- use of non-original or non-specific spare parts; 
- failure to follow the instructions given in this manual. 

This appliance is not intended for use by persons -including
children- with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have
been fiven superfision or instruction concerning use of the
appliance by a person responsible for their safeti. Children
should be supervised to ensure that they do not play with
appliance.

1.2

INSTALLATION

The machine must be installed by a specialised technician
authorised by and in compliance with the instructions given
in this manual. 
In the event that the machine is fitted with a remote con-
denser  unit,  the  installation  technician  is  responsible  for
checking all connections in compliance with the instructions
given by for plant and machine installation.

1.3

TRANSPORT AND HANDLING

To  load  or  unload  the  machine  and/or  components
from/onto the means of transport, use a lift truck or fork lift
equipped with forks that are at least half the length of the
machine housing; use a crane if the machine is fitted with
eye bolts. Select the lifting equipment suited to the weight
and overall dimensions of the packaged machine/compo-
nents. 

When handling the machine/ components, apply all precau-
tions to prevent damage, in compliance with the information
given on the packaging material

1.4

UNPACkING

Remove  all  cardboard,  wood  or  other  materials  from  the
wood  base  on  which  the  machine  is  set.  Lift  the
machine/components with suitable means (e.g. lift truck), re-
move the wood base, then position the machine / compo-
nents in the allocated site. 

Once all packing material has been removed, check that the
machine has not been damaged in any way. 

Remove the protective PVC film on the stainless steel panels
from all internal and external surfaces. 

Always  wear  protective  gloves  when  handling  packing
material and the wood base.

Nota:

Dispose of packing materials in compliance with disposal

regulations applied in the country where the machine is to be
installed. Never dispose of materials in the environment. (see  sec-
tion 2.9).

1.5

GENERAL SAFETY REGULATIONS 

Failure to observe the recommendations made by the pre-
sent manual will be at the entire responsibility of the ma-
chine user. The main safety regulations are as follows: 

do not touch the machine with moist or wet hands or feet;

never operate the machine while barefoot;

do not insert screwdrivers, cooking utensils or any other
object between the guards and moving parts;

before performing cleaning or routine maintenance ope-
rations, disconnect the machine from the power supply at
the master switch and the main knife switch (if present);

never pull on the power cable to disconnect the machine
from the power supply.

i

 


background image

English

3

BLAST CHILLER ISTRUCTION

2. INSTALLATION

2.1

DATA PLATE INFORMATION

Check that the data specified on the plate correspond to the
characteristics of the power supply (V, kW, Hz, no. phases and
power available). 

The dataplate with appliance specifications is located at the
rear exterior of the machine and/or on the electrical boards.

The  set-up  of  individual
units and the installation of
condensers  are  subject  to
the fire-safety regulations of
the  country  in  which  the
machine is installed; seek all
necessary advice from the
local  fire-fighting  authori-

ties. 
Bear in mind that the intervention of safety valves or plug
fuses in the refrigerating circuit will lead to the immediate
discharge of refrigerant into the environment. 

2.2

REMARkS / MALFUNCTION’S CLAIMS

In case of  machine malfunctioning and claim on  Blast Chil-
lers delivered in the following way :

Assembled

We  ask  you  to  indicate  to  the  dealer  /  service:  machine
model, machine code number and apparatus serial number.
These information are written on the registration label, instal-
led on the back of machine and inside the door.

Disassembled

We  ask  you  to  indicate  to  the  dealer  /  service:  machine
model, machine code number and apparatus serial number.
These information are written on the registration label, instal-
led on top of the control panel.

2.3

POSITIONING

The machine must be installed and commissioned in com-
plete compliance with safety regulations, procedures and
standing laws. 

The installation technician bears the responsibility of ensu-
ring compliance with fire safety requirements; seek all neces-
sary advice from the local fire-fighting authorities. 

Position the machine in the allocated site.

Adjust the machine feet until the appliance is perfectly level.
In the case of particularly heavy equipment, use appropriate
lifting means (fig. A - Cap. 1.3).

If the appliance is not perfectly level, correct operation and
condensate flow-off will not be assured.

Avoid

direct exposure to sunlight;

closed sites with high temperatures and poor air circulation;

installing the machine near sources of heat.

2.4

AMBIENT TEMPERATURE AND AIR CIRCULATION 

For air-cooled appliances, the maximum ambient tempera-
ture for operation is 32°C. Correct operation cannot be gua-
ranteed at higher temperatures. 
The machine may operate safely to a maximum temperature
of 38°C. 
Remote condensing units must be installed in special rooms
or outdoors, protected against direct sunlight by a shelter or
roof structure (at the cost of the purchaser). 
Sufficient air circulation must be guaranteed at all times. 

2.5

ELECTRICAL CONNECTIONS

A  dedicated  thermal-magnetic  circuit  breaker  compliant
with established regulations must be installed on the ap-
pliance power line. 

Connected electrical cables must correspond to the techni-
cal data (as specified on electrical drawings provided by the
installation technician). 
Connect the earthing conductor to an efficient earthing sy-
stem. 

The manufacturer declines all liability and guarantee obli-
gations  in  the  event  of  injury  to  persons  or  damage  to
equipment and objects due to incorrect installation and/or
failure to comply with standing installation regulations.

2.5.1 Connecting the appliance to the power supply

In the event of damage to the power supply cable on the ap-
pliance, have the cable replaced only by a qualified electri-
cian to avoid any risk of personal injury

   

THESE OPERATIONS MUST BE 

   PERFORMED BY A CERTIFIED 

            INSTALLATION TECHNICIAN ONLY

Serial

~

Hz

A

W

kg

W

W

W

38Ø-4ØØ/3N

3ØØØ

Machine model

AX8

ØØØ 1Ø3 Ø3213

R4Ø4 A

2.2

CLASS T

11

IP 21

 


background image

English

4

Blast chiller istrUction st

2.6

REFRIGERATION COMPONENT CONNECTIONS
REMOTE ASSEMBLIES

appliance power lines are sized for installation distances of
up to 10 metres. for greater distances, seek advice from.

2.7

CONDENSATE DRAINAGE CONNECTION

fit a condensate/wash water drainage hose with a minimum
diameter of 1” (“Geberit” or similar type).

Provide a waste pipe with a

trap with a diameter of at least
1 1/2” at floor level.

 

2.8

INFORMATION FOR THE INSTALLATION TECHNICIAN 

Before starting up the machine, check that it has been cor-
rectly installed and commissioned (test report).

1. check that there are no gas leaks from weldings or joints

made during installation works. 

2. check that the pipes connecting the condenser to the re-

mote condensing unit have been well insulated. 

3. check all wiring connections.
4. check electrical input.
5. check the standard pressure in the refrigerant system.
6. check the water connections and efficiency of the pressure

switch valve during operation, as well as the flow of conden-
sing water (in water-cooled units).

7. Perform at least one blast freezing cycle (to the set tempe-

rature) and one manual defrosting cycle.
in the event that the appliance or the remote condensing
unit have not been transported in a vertical position (e.g. on
the back) or have been overturned during installation works,
allow at least 4 hours before starting up the equipment.

inform the customer of the exact purpose of the appliance,
with specific reference to the use and requirements of the
customer.

The appliance must be installed and put into service by a
technician authorised.

2.9

SAFETY AND CONTROL SYSTEMS

Door microswitch:

shuts down fan operation in the cell when the door is ope-
ned.

General fuses:

protect the power circuit against short circuiting and over-
loads.

Compressor heat relay:

intervenes in the event of overloads or operating faults.

Safety pressure switch:

intervenes in the event of excessive pressure in the refrige-
rant circuit.

Plug fuses:

intervene in the event of overpressure or operating fault in
the safety pressure switch (see above).

Chamber temperature control:

operated by the electronic board by means of a probe inside
the cell.

Temperature control end defrost cycle:

controlled by the electronic board by means of the probe in
the evaporator.

2.10 DISPOSAL OF WASTE ELECTRONIC AND ELECTRICAL

EQUIPMENT (WEEE) 

The following information regards member states of 

the EU. The crossed-out litter bin symbol indicates 

that the product cannot be disposed of as residential 

waste. Ensuring that this product is disposed of 

correctly will help prevent potential negative effects 

on the environment and to human heath that could be 

caused if disposed of in an incorrect manner.

 


background image

English

5

BLAST CHILLER ISTRUCTION

3. ADVICE TO ENSURE EFFICIENT APPLIANCE OPERATION

3.1

SHUT-DOWN PROCEDURES

In the event of emergency, shut down the appliance by swit-
ching off power at the main panel, by means of the knife
switch or by removing the plug from the power socket. 

3.2

OPERATING TIPS 

Before starting up the appliance, clean the inside of the cell
thoroughly.

3.2.1 Pre-cooling 

Before using the appliance for the first time, or after a pro-
longed  period  of  disuse,  pre-cool  the  cell  by  running  an
empty cycle until the set operating temperature has been
reached. 
To ensure optimal performance without any alteration to
food quality: 

arrange food products in such a way as to favour the circula-
tion of cold air throughout the cell; 

open the door as little as possible.

3.2.2 Loading the appliance

a)

Ensure that foods to be chilled and/or frozen are separate
and do not have a thickness greater than 50-80 mm. Do not
load the appliance beyond the quantity recommended by
the manufacturer.

b)

Ensure that there is sufficient clearance between trays to ena-
ble free air circulation.
If the appliance is not completely full, distribute the trays and
foods evenly throughout the available space.

c)

Position trays inside the tray compartment as far as they will
go, as close as possible to the evaporator.

d)

Position the core probe at the centre of the largest product
or food item; make sure that the tip of the probe does not
protrude or touch the tray.
The probe must be cleaned and sanitised before each new
cycle (operation) to prevent inadvertent contamination.

e)

Avoid covering the trays and/or containers with insulating
covers or film. The more the product is insulated, the more
time is required for chilling or freezing.
Trays must be packaged when the product has been chilled,
before being placed in storage.

0.5 - 2cm.

 


background image

English

6

BLAST CHILLER ISTRUCTION

4. PROGRAMMING AND OPERATION INSTRUCTIONS

4.1

MACHINE STARTUP

Power the machine up
The machine can be in:

STAND-BY.

With the machine off, the display is as follows (the keys/unlit
symbols in gray), the cell probe values are displayed:

OFF Condition

With the machine shut down, to move to the off status, press
the Start/Stop button 

q

for at least 3".

to exit the off status press the Start/Stop button 

q

(the only

enabled button) for at least 3".

4.2

SETTING THE DATE AND TIME

Turn the machine off by holding the Start/Stop button 

q

for

3".  Then hold the freeze button 

r

down for 3".

The year (

YY

) will appear, which can be changed using the

up 

u

and down 

y

buttons. Confirm using the freeze button

r

.

Then the month (

nn

), day (

dd

), hour (

hh

) and minutes

(

no

) appear in succession, also modifiable with the up 

u

and down 

y

buttons. Confirm the data each time with the

freeze button 

r

.

Once the minutes have been confirmed, it exits the clock set-
ting function and returns to the OFF condition.

Note:

in case of ALARM 

RTC

on the display it’s necessary to

provide to set the time.

4.3

OPERATION
It is recommended always to pre-cool the machine the
first time blast-chilling or deep freezing is performed.
The work cycle is optimized in this way by reducing the
time (see chap. 4.3.7).

4.3.1 Selecting positive blast chilling timed cycle

With the machine in standby, select the positive blast chilling
button 

e

; the display will show the value

90 min. 

To increase or decrease the blast chilling time, use the up 

u

and down 

y

buttons. 

To  start  the  positive  blast  chilling  timed  cycle,  press  the
Start/Stop button 

q

. When the cycle starts, the time will

begin to count down.
The arrows on the left hand side 

w

flash during blast chilling

and are steady during the storage phase. The machine may
be stopped at any time by pressing the Start/Stop button 

q

for 3 seconds.

Once the blast chilling time has expired, it will automatically
go into storage mode.
In the storage phase the cell temperature will be displayed.

4.3.2 Selecting positive blast chilling temperature cycle

With the machine in standby, select the positive blast chilling
button 

e

. The display will show the value 

90 min. 

To  select  the  temperature  mode  press  the  blast  chilling
mode button 

e

and the default value appears: 

+3°C

Use the up 

u

and down 

y

buttons to increase or decrease

the end blast chilling temperature.

Insert the product inside the blast chiller making sure to po-
sition the probe on the product.

To start the positive blast chilling temperature cycle, press
the Start/Stop button 

q

. The arrows on the left hand side 

w

will flash during chilling and will be steady during the storage
phase.
The machine may be stopped at any time by pressing the
Start/Stop 

q

button for 3 seconds

Once the set blast chilling temperature has been reached,
the machine will automatically go into storage mode.
In the storage phase the cell temperature will be displayed

i

   

IN THE EVENT OF A MALFUNCTION, 

   CALL THE CERTIFIED TECHNICIAN

3 sec

 


background image

English

7

BLAST CHILLER ISTRUCTION

4.3.3 Selecting positive hard blast chilling timed cycle 

With the machine in standby, select the positive blast chilling
button 

e

twice. The display will show the value 

90 min 

with

the prefix h, indicating that the hard cycle was selected.

To increase or decrease the blast chilling time, use the up 

u

and down 

y

buttons. 

To  start  the  positive  blast  chilling  timed  cycle,  press  the
Start/Stop button 

q

. At the beginning of the cycle, the time

will begin to count down. The arrows on the left hand side

will flash during chilling and will be steady during the

storage phase.
The hard symbol 

t

will flash during the second phase of the

hard cycle. The machine may be stopped at any time by hol-
ding the Start/Stop button 

q

down for 3 seconds

On the end of the Hard cycle the system goes automatically
in positive preservetion phase.
In the storage phase the cell temperature will be displayed.

Note:

the duration of the hard phase is handled automatically

by the Blast chiller. The period of hard phase is determined au-
tomatically in percentage  by the parameter set in the factory
under password. 
The duration of the hard phase will be 66% of the time setting.

Ex:

setting the total time of hard chilling  at 100 ', the hard phase

will be hard to 66 ', while the soft phase will be 34'.

4.3.4 Selecting positive hard blast chilling temperature cycle

With the machine in standby, select the positive blast chilling
button 

e

TWICE, the display will show the value 

90 min

,

with the prefix h.

To  select  the  temperature  mode,  press  the  blast  chilling
mode button 

t

and the default value will appear: 

+3°C

Use the up 

u

and down 

y

buttons to increase or decrease

the blast chilling temperature. 

Insert the product inside the blast chiller making sure to po-
sition the probe on the product.

To start the positive hard blast chilling temperature cycle,
press the Start/Stop button 

q

. The arrows on the left hand

side 

w

will flash during chilling and will be steady during the

storage phase.
The machine may be stopped at any time by pressing the
Start/Stop button 

q

for 3 seconds

Note:

the hard chilling at temperature works in the first phase

at negative temperature in the cell, until the core probe will de-
tect a temperature at core of 15 ° C. 
A this point the chilling will pass to the second phase of the cycle
with a higher temperature in the cell until the needle probe de-
tects a temperature in the product  of +3 °C.
Then the chiller will pass to preservation phase 

Once the set blast chilling temperature has been reached in
the product core, the machine will automatically go into sto-
rage mode.
In the storage phase the cell temperature will be displayed.

4.3.5 Selecting blast freezing timed cycle

With the machine in standby, select the freezing button 

r

,

the display will show the value 

240 min. 

To increase or decrease the freezing time, use the up 

u

and

down 

y

buttons. 

To start the freezing timed cycle, press the Start/Stop button

q

. At the beginning of the cycle, the time will begin to count

down. The arrows on the left hand side 

w

will flash during

chilling and will be steady during the storage phase. The ma-
chine may be stopped at any time by pressing the Start/Stop
button 

q

for 3 seconds

Once the freezing time has expired, the machine will auto-
matically go into storage mode.
In the storage phase the cell temperature will be displayed.

4.3.6 Selecting blast freezing temperature cycle

With the machine in standby, select the freezing button 

r

,

the display will show the value 

240 min. 

To  select  the  temperature  mode,  press  the  blast  chilling
mode button 

t

and the default value will appear 

- 18°C.

To increase or decrease the freezing time, use the up 

u

and

down 

y

buttons. 

Insert the product inside the blast chiller making sure to po-
sition the probe on the product.

To start the freezing temperature cycle, press the Start/Stop
button 

q

. The arrows on the left hand side 

w

will flash du-

ring freezing and will be steady during the storage phase.
The machine may be stopped at any time by pressing the
Start/Stop button 

q

for 3 seconds

Once the set freezing temperature has been reached in the
product core, the machine will automatically go into storage
mode.
In the storage phase the cell temperature will be displayed.

i

i

 


background image

English

8

BLAST CHILLER ISTRUCTION

4.3.7 quick selection of positive blast chilling indefinite timed

cycle

With the machine in standby, select the positive blast chilling
button 

e

for  at  least  3",  a  positive  cycle  for  an  indefinite

amount of time will start immediately, and 

POS

will appear

on the display.

The arrows on the left hand side 

w

will flash during blast

chilling and won't go into storage mode, the blast chiller will
cycle around the minimum cell temperature set for the blast
chilling time cycle. The machine may be stopped at any time
by pressing the Start/Stop button 

q

for 3 seconds

4.3.8 Selecting the ice cream hardening / freezing indefinite

timed cycle

This function will allow the user to use the blast chiller using
the following method:

With the machine in stand-by, select the freezing cycle; the
button 

r

lights up. Then press the freezing button 

r

for 3

seconds, the first LED will show the letter 

t

and the time set

for the hardening cycle will flash (time given by the Pt4 pa-
rameter). An indefinite timed freezing cycle will start imme-
diately.

The user can modify the hardening cycle time using the up

u

and down 

y

buttons while the time is flashing, and only

at this time.

When the user opens the door (to put the ice cream in) and
then closes it, a beep will sound confirming that it is closed
and the countdown will start. The display will show the coun-
tdown time without flashing.
When the time arrives at zero, the buzzer will sound for 60
seconds and the count remains at zero and flashes. Any time
the door is closed, the countdown is interrupted and a new
one starts. The display is used as a timer while the cycle is on-
going and guarantees negative temperatures in the cell. The
user can interrupt this function by pressing the Start/Stop
button 

q

for 3 seconds.

4.4

DRYING CYCLE
Selecting drying and forced ventilation

With the machine in standby, select by pressing with a single
pulse the down button 

y

Air 

will be flashing on the display.

Drying is timed. To stop it in advance, press the down button

y

. Opening the door does not affect the drying cycle

4.5

RAPID DISPLAY OF TIME AND TEMPERATURE VALUES

With the machine in operation, the following operation va-
lues can be seen:

Total time set for a Positive Soft/HardTimed Cycle 

wr

:

Pressing the positive blast chilling button 

e

will display the

total time set initially for 5", in flashing mode.

Final temperature set for a Positive Soft/Hard Tempera-
ture cycle 

er

:

Pressing the positive blast chilling button 

e

will display the

final set temperature for 5" in flashing mode.

Total time set for a Freezing Timed Cycle 

wy

:

Pressing the freezing button 

r

will display the total time set

initially for 5" in flashing mode.

Final temperature set for a Freezing Temperature Cycle

ey

:

Pressing the freezing button 

r

will display the final set tem-

perature for 5" in flashing mode.

Probe temperature in a Blast Chilling/Freezing cycle:

Pressing the blast chilling type button 

t

during a blast chil-

ling/freezing temperature cycle, will display the probe tem-
perature for 5 seconds.

Time elapsed during a blast chilling cycle:

Pressing the down button 

y

during a blast chilling cycle will

display the amount of time elapsed for 5 seconds in flashing
mode.

Cell sensor temperature during a blast chilling cycle:

During any blast chilling cycle, pressing the up button 

u

di-

splays the value of the cell sensor for 5" and then the evapo-
rator sensor for 5", if enabled (if there is a buzzer alarm, it also
silences the alarm).

4.6

SANITIZING CYCLE (optional)

If the password controlled parameters are enabled, a time-
controlled sanitizing cycle may be started. To activate the sa-
nitizing cycle, the equipment must be in off mode. Then,
pressing the up button 

u

for 3 seconds activates the saniti-

zing cycle, the set minutes will appear on the display and the
countdown will begin, once it is completed it automatically
deactivates and returns to the off position.

To stop the sanitizing cycle early, just press the Start/Stop
button 

q

for 3 seconds and it will go to standby mode.

If the door is opened, it will immediately deactivate and
can only be reactivated in off phase.

Before starting the sanitizing cycle, proceed as follows:

remove products from the interior

thoroughly clean with warm water and neutral detergent

close the door

start the cycle.
Use of this cycle is recommended only when processing has
completed.

3 sec

3 sec

3 sec

 


background image

English

9

BLAST CHILLER ISTRUCTION

5. PARAMETERS

5.1     PARAMETER MODIFICATION ACCESS

The parameters can be accessed only when the machine is
off. Just press the blast chilling button 

t

for three seconds,

PASS

will appear on the display and the up 

u

, down

y

and blast chilling mode buttons 

t

will light up.

Pressing only the up 

u

and down 

y

buttons accesses only

the 

user parameters.

          To scroll through the parameters, press the up 

u

and down

y

buttons. To make changes, once the parameter has been

selected,  press  the  blast  chilling  mode  button 

t

and

change the parameter value using the up 

u

and down 

y

buttons. To confirm the value and exit modification mode,
press the blast chilling mode button 

t

.

5.2     LIST OF PARAMETERS

          

Following is the list of available parameters

5.3     DEFROSTING MANAGEMENT (only in certain models)

          Manual defrosting is started by pressing the Defrost button

y

for 3 seconds when the panel is in standby. Manual de-

frosting is shut off by pressing the on/off button 

q

for 3 se-

conds

5.4     USB DATA RECORDER (OPTIONAL)

The USB data recorder will register into a .txt file all the data
during the cycles of the machine: Blast Chilling or Freezing
and also during conservation phase. 

The data is registered every minute and will include:
- Date and time
- Cabinet Temperature
- Core probe Temperature 
- Type of Cycle 
- Start and Stop of Cycle
- Door openings
- Alarms

The data is constantly stored on the internal recorder, and
can be downloaded anytime from the internal recorder in-
troducing a USB pen drive into the plug on the machine.

Instructions to download the data

1. Find on the machine the USB plug and insert the USB pen

drive

2.

IMPORTANT:

wait until the led of the pen drive stops fla-

shing, which means that all the data is recorded on the pen
drive.

3. Extract the pen drive
4. On the pen drive you will find a file named log00n000001.txt

which is a text file, delimited with “;” (semicolon).

The best way to see the data on the file is using Microsoft
Excel, following this sequence:
- Launch Microsoft Excel
- Go to “open file”
- Select “text file” on the type of file
- Open the file registered on the pen drive
- Select “Delimited” file
- Select as delimitator the semicolon “;”

As an alternative you can open the file with a normal text edi-
tor

Every time you insert the pen drive, a new log file will be ge-
nerated,  with  a  progressive  number  (log00n000002.txt,
log00n000003.txt, log00n000004.txt, etc).

Every file generated will contain the complete historical data
recorded, up to the moment of insertion of the pen drive. So
every time the file is bigger.

As a consequence, the time to save the file on the pen drive
(see point 2.) will increase from some seconds to several mi-
nutes, depending on how much data is stored on the recor-
der. IT’S VERy

WAIT  UNTILL  ALL  THE  DATA  IS  RECORDED  ON  THE  PEN
DRIVE BEFORE REMOVING IT, WAITING UNTIL THE LED ON
THE PEN DRIVE STOPS FLASHING. 

When  updating data: time, day, and year on the board of
the computer, it’s necessary  to remove and then restore the
power supply to allow the change data is also stored in the
USB recorder.

3 sec

Parameter

Min

Max U. M. DEF

P0

Choose temperature unit of measure (0 = Fahren-
heit, 1 = Celsius)

0

1

1

Fla

g

Adjustment set point

Pr1 Blast chilling cell set point

-20

30

-5

°C

Pr2 Positive storage cell set point

-20

30

+3

°C

Pr3 Freezing cell set point

-50

20

-40

°C

Pr4 Negative storage cell set point

-50

20

-25

°C

Pr6 End blast chilling product temperature

-20

30

+3

°C

Cycle  times

Pt0 Max blast chilling temperature cycle duration

1

200

90

min

Pt1 Max freezing temperature cycle duration

1

400 240 min

Pt2

Cycle proposed for startup/after cycle stop:
0 = startup from off, 1 = startup from standby wi-
thout cycle selected,
2 = positive timed, 3 = positive hard timed, 4 = ne-
gative timed, 5 = positive temperature, 
6 = positive hard temperature, 7 = negative tem-
perature,

0

7

0

flag

Pt3

After stop cycle offers: 0 = last cycle, 1 = cycle defi-
ned by Pt2, 2 = no cycle

0

2

2

flag 

Pt4 Ice cream hardening timer time

1

20

10

min 

Pt5 Duration hard time phase (blast chilling cycle %)

1

99

66

min

 


background image

English

10

BLAST CHILLER ISTRUCTION

6    GREAT TECHNOLOGY AND PROCESS VALUE

Putting freshly cooked food directly in the storage unit is a
mistake! Cooling is static and not very powerful, the chilling
time is too long and bacteria develop rapidly in large quan-
tities.

Only by using a chilling system with forced ventilation heat
exchange can we be sure that we are preserving the high
initial quality of the food: its appearance, colour, flavour and
aroma.

Cold, like heat, if not properly managed and metered can vi-
sibly damage food.

Since every food has its own characteristics, the use of a spe-
cific chilling system every time is important.
Our equipment is characterized by its versatility and the avai-
lability of several functions in the same machine.
- Quick “

Soft

” blast chilling for delicate products with a redu-

ced thickness.
- Quick  “

Hard

” blast chilling for all dense products, in large

pieces or packaged.
- Quick freezing.

6.1

"SOFT" BLAST CHILLING

From +70°C to 3°C at the product core within a maximum of
90 minutes, with air temperature that is always and only po-
sitive (0/+2°c), avoiding any type of freezing of the surface
of the food.

6.2

"HARD" BLAST CHILLING

From +70°C to +3°C at the product core within a maximum
of 90 minutes, with variable chamber air temperature auto-
matically controlled by the computer. This system allows for
a 25-30% time savings in comparison to the "soft" cycle!

6.3

QUICK BLAST FREEZING

function available only in certain models
From +70°c to -18°c at the product core as quickly as possibly
and within at most 4 hours, with a chamber air temperature
of -40°c. Rapid cold penetration prevents the transformation
of water into macro-crystals, thus not ruining the consistency
and integrity of the food.

Each cycle can be 

manually

controlled using the timer or au-

tomatically controlled with the food probe. The 

automatic

storage 

function at the end of the cycle and the 

automatic

and  manual  defrosting 

cycles  complete  the  exceptional

blast chiller accessories.

Temp.

+70°C

+60°C
+50°C
+40°C
+30°C
+20°C
+10°C

+3°C

0+2°C

-10°C
-20°C
-30°C
-40°C

10     20     30     40     50     60     70     80     

90  

Tempo

temperature 
at the
product core

Processing air
temperature

Temp.

+70°C

+60°C
+50°C
+40°C
+30°C
+20°C
+10°C

+3°C

0+2°C

-10°C
-20°C
-30°C
-40°C

10     20     30     40     50     60     70     80     

90  

Tempo

temperature 
at the
product core

Processing air
temperature

Temp.

+70°C

+60°C
+50°C
+40°C
+30°C
+20°C
+10°C

+3°C

0+2°C

-10°C

-20°C

-30°C
-40°C

0, 30’  

  1  

  2  

  3  

  

4 ore

Tempo

temperature 
at the
product core

Processing air
temperature

 


background image

English

11

BLAST CHILLER ISTRUCTION

7    ALARMS LIST

Note: Faults probes 

Once the sensor is replaced, the alarm di-

sappears after 10 seconds. The sensor alarms at -50°C are disa-
bled  during  freezing  at  -18°C  and  during  the  ice  cream
hardening function. Where not specified, each alarm is accom-
panied by a buzzer (if present). The sound made is a five second
beep that is repeated every 15 seconds. The label indicating the
alarm in progress is alternately displayed with the current display.

ALL 

Er1

Cell sensor failure

Cause:

Outside of operating range
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.

Effect:

In standby it prevents startup of blast chilling/
freezing. 
In blast chilling/freezing and storage, the cycle is
not blocked and the compressor is activated in cy-
cles (according to the parameters)

Reset:

check connections and operation of the 
cell sensor

ALL 

Er2

Evaporator Sensor Failure

(only if evaporator sensor is enabled)

Cause:

Outside of operating range 
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.

Effect:

In standby, blast chilling/freezing
and storage, there is no effect.
Any defrost will end due to a timeout.

Reset:

check connections and operation of the evapora-
tor sensor

ALL 

Er3

Product Probe Failure

Cause:

Outside of operating range
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.

Effect:

In standby it prevents startup of temperature con-
trolled blast chilling/freezing. In temperature con-
trolled blast chilling/freezing it causes a change
over to a timed cycle. In storage, there is no effect.

Reset:

Check connections and operation of the product
probe.

ALL 

AL1

Door Open Alarm

Effect:

In standby and defrost there is no effect. For the
effects on the compressor and fan, see parameters.

Reset:

close the door, verify the micro door operation

ALL 

AL2

High Pressure Alarm

Effect:

In standby there is no effect.
In blast chilling/freezing and storage it blocks the
cycle and the panel returns to standby

Reset:

eliminate the cause of the alarm, turn the panel off
and back on.

ALL 

AL4

Probe not inserted alarm

Cause:

failure to insert the probe inside the product du-
ring execution of temperature controlled blast
chilling

Effect:

The display shows alarm AL4, the temperature
icon 

e

flashes and the buzzer sounds

Reset:

Insert the probe and restart the temperature cycle
using the button 

t

.

To proceed without the probe, start a timed cycled
using the button 

y

.

If no choice has been made after the alarm has
been sounding for one minute, the machine will
automatically start a temperature cycle.

ALL 

BLC

Blackout Alarm

Cause:

following a power interruption, the machine is in
blackout alarm

Effect:

the machine goes into standby or storage mode if
the machine is in blast chilling mode when the
blackout occurs, the set cycle will restart and the
display will show the BLC alarm alternating with
the blast chilling settings. The buzzer sounds every
3 seconds

Reset:

To silence the alarm, press the 

u

button.

ALL 

S

XX

Temperature Alarm

Cause:

The blast chiller doesn't reach the set temperature in
the time expected during blast chilling/freezing

Effect:

The cycle continues and doesn't go into storage
mode, the display shows the alarm followed by
the temperature, and the buzzer sounds for 3 se-
conds and then repeats after a minute 

ALL 

Ht

High Temperature Alarm

Cause:

the cell sensor (only during storage) detects a tem-
perature above the set parameters for a certain
amount of time.

Effect:

The display shows the Ht alarm alternating with a
temperature value, the buzzer sounds for 3 seconds
every 30 seconds.

ALL  

rtc 

Clock error

Reset the date and the real time (see item 4.2).

ALL  

Er[ 

Interface error

Cause :

User interface – control module compatibility error

Solutions:

Check the user interface control module compatibi-
lity (check the data given on the labels)

Effect : 

The control module will continue to operate regu-
larly

ALL  

ErL 

Interface error

Cause :

User interface – control module communication
error

Solutions:

Check the user interface control module connection

Effect : 

The control module will continue to operate regu-
larly

When the cause triggering the alarm disappears, the instrument re-
stores normal operation, except for the clock error (

rtc

code),

which requires the date and time to be set.

i

 


background image

English

12

BLAST CHILLER ISTRUCTION

8    

ORDINARY MAINTENANCE

          The information and instructions in this chapter are intended

for all personnel who operate the machine: the user, main-
tenance personnel and even non-specialized personnel.

All cleaning and maintenance operations must be perfor-
med with the power disconnected from the electrical sy-
stem.

8.1     ELEMENTARY SAFETY STANDARDS

In order to safely perform ordinary maintenance and clea-
ning operations, we will revisit the safety standards:
- do not touch the machine with wet or damp hands or feet;
- do not use the machine when feet are bare;
- do not insert screwdrivers, cooking utensils or anything else
between the protective devices and moving parts;
- before performing any ordinary maintenance or cleaning
operation, disconnect the machine from the electrical supply
by turning off the main switch and pulling the plug;
-do not pull on the electrical cord to disconnect the machine
from power.

Removing the safety and protective devices in order to per-
form ordinary maintenance operations is strictly forbidden.
The manufacturer denies any responsibility for accidents cau-
sed by failure to comply with this requirement.

Before starting the machine, the interior of the cell must be
thoroughly cleaned as indicated in paragraph 8.3.

8.2     CONDENSOR CLEANING

For correct and efficient condenser operation, the air con-
denser must be kept clean to allow for free air circulation.
This operation is to be performed at least every 30 days. It
can be performed with a non-metallic brush to remove all of
the dust and fluff from the wings of the condenser itself.

The use of a vacuum cleaner is recommended in order to
avoid dispersing the dust removed into the area. Whenever
there are greasy deposits, remove them using a brush soaked
in alcohol.

Do not scrape 
the surfaces with 
pointed or 
abrasive objects.

This operation
must be performed with the system shut down

The condenser has sharp edges. During the
above-mentioned operations, always wear
safety gloves, safety glasses and masks to
protect the respiratory tract.

8.3     CELL CLEANING

in order to guarantee the hygiene and safeguard the quality
of  the  treated  food  products,  cleaning  of  the  cell  interior
must be done frequently, depending upon the type of food
stored.

Weekly cleaning is advised.

The configuration of the cell and internal components do
not allow cleaning using a cloth or sponge.

Clean using water and non-abrasive neutral 

d e t e r -

gents.
Rinsing can be done with a wet cloth or sponge or with a
moderate spray of water (no greater than the system water
pressure). Do not scrape the surfaces with pointed or abra-
sive objects.

Do not use abrasives or solvents and thinners.

Note:

during cleaning operations, always wear protective glo-

ves.

8.4     ExTERNAL MAINTENANCE AND CLEANING

To clean the body, all that is needed is a cloth dampened
with a product specifically for stainless steel, without bleach.

i

   

THESE OPERATIONS MUST BE 

   PERFORMED ExCLUSIVELY

            BY A CERTIFIED INSTALLER

 


background image

English

13

BLAST CHILLER ISTRUCTION

Evaporator cleaning

The interior of the evaporator must be cleaned periodically
in the following manner:

Remove the screws that hold the steel fan panel from the
evaporator and open the panel as indicated

Clean the evaporator battery using a jet of hot water at low
pressure, aiming it from high to low on the evaporator. Make
sure that the water is drained through the drain pipe.

When complete, used compressed air to remove all of the
water from the evaporator battery.

Repeat the operation described above to close the fan panel.

Before starting the machine, make sure you have remo-
ved any tools used for cleaning and that the drain plug is
closed.

7.5     DEFROST WATER DRAINING

the system is set up for automatic (in certain models)
and manual defrosting when necessary.

make sure that the evaporator water is correctly draining in
the collection basin, avoiding any obstructions of the drain
pipe.

Fig. 1

Fig . 2

Fig . 3

Fig . 4

 


background image

English

14

BLAST CHILLER ISTRUCTION

 


background image

Via del Lavoro, 9 - C.P. 172 - 31033 Castelfranco Veneto (TV) - ITALY - EU 
Tel. +39 0423 738451 - Fax  +39 0423 722811 - tecnomac@castelmac.it  - www.tecnomac.eu

Castel Mac SpA

71504057/0

     Rev.01   06/2016  - Manuale uso e manutenzione 

a socio unico