PDF User Manual

  1. Home
  2. Manuals
  3. TecnoVideo 204 series Installation Manual

TecnoVideo 204 series Installation Manual

Made by: TecnoVideo
Type: Installation Manual
Category: IP Camera
Pages: 4
Size: 0.4 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

204 Series

Large size Stainless Steel Camera Housing

 

Installation manual

Issue 20131017

 


background image

DESCRIPTION

The 

204 

series is entirely made in AISI316L stainless steel, for use in industrial and marine environments and in general where a

corrosive atmosphere can cause a rapid deterioration of a standard aluminium-steel housing. 

MODELS

204-110

 

Camera housing (L=500 mm). UFW: 110 mm

204SH110

Camera housing (L=500 mm) with sunshield and heater. UFW: 110 mm

204-145

Camera housing (L=500 mm). UFW: 145 mm

204SH145

 

Camera housing (L=500 mm) with sunshield and heater. UFW: 145 mm

204WW120

 

Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 120 mm

204WW140

 

Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 140 mm

204IR70

Camera housing (L=500 mm). Shutter optional. UFW: 70 mm.

204SHIR70

Camera housing (L=500 mm) with sunshield and heater. UFW: 70 mm.

204WWIR70

Camera housing (L=500 mm) with sunshield, heater and integrated wiper included. UFW: 70 mm.

204IR110

Camera housing (L=500 mm). UFW: 110 mm.

204SHIR110

Camera housing (L=500 mm) with sunshield and heater. UFW: 110 mm.

204WWIR110

Camera housing (L=500 mm) with sunshield, heater and integrated wiper. UFW: 110 mm.

204IR145

Camera housing (L=500 mm). UFW: 145 mm.

204SHIR145

Camera housing (L=500 mm) with sunshield and heater. UFW: 145 mm.

UFW:

Usable front window diameter

-L

 suffix refers to camera housing with L=600 mm.

INSTALLING THE CAMERA

i

Prior to installation and operation, read carefully all instructions the in this manual and heed all warnings.
Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper immediately.
Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of returning the equipment,
the original packaging must be used.
Make sure that the installation surface can support at least four times the weight of the unit in normal operating conditions. In case
of excessive external stress (e.g. vibration, strong winds or impact), the equipment may need additional means of protection.
Proper stainless steel hardware should be carefully chosen to fasten the unit to the surfaces.
Use caution when lifting and assembling the unit. It is recommended that non-slip protective gloves be worn during installation.
The unit could bear sharp edges.
Trying to manually force the wiper will result in damaging the device and will void the warranty.
To maintain the IP rating of the unit, adequate cable glands must be used. The unit must be tightly closed when operating.
For security reasons, do not install the unit in the proximity of water containers and never push objects or pour liquids into the
unit. The unit can be safely used in damp environments or outdoors, as long as the connectors are properly sealed.
Video and data cables should not share the same conduit with supply voltage cables. Whenever EMC is an issue, adequately
shielded cables must be used.
Open only the covers pointed out in this installation manual. Other covers should be open only by the manufacturer.
This equipment has been designed to fit in harsh environments requiring little or no maintenance. Suggested inspection interval is
6 months, but extremely harsh environments may require more frequent inspection and maintenance checks. On each inspection
check the O-ring seals and the eventual window wiper blade integrity. Replace them if necessary. 
Check cables, electrical connections and mounting hardware for integrity and tightness. Replace or tighten any damaged/loose
part.
Operating temperature: -20° +55° C (-4° +131° F).

h

Before performing any operation, turn off the power. The installation of the unit can be performed only by qualified personnel in
accordance with the regulations in force. Do not connect the unit to a supply circuit unless the installation is completed.
Check carefully the supply voltage marked on the label. Incorrect Power Supply Voltage may damage the unit. Do not overload
the terminal connection, as it may cause a fire or electrical shock hazard.
An all-pole mains switch with an opening distance between the contacts at least 3 mm in each pole must be incorporated in the
electrical installation. The switch must be equipped with protection against the fault current towards the ground (differential) and
the overcurrent (magnetothermal, maximum 15A). It must be very quickly recognizable and readily accessible. A suitable blow fuse
must also be installed for protection.
For connection to the mains, use a multipolar cable having minimum 3x1,5 mm

2

  (15 AWG). The main cable must be at least

protected by an ordinary PVC sheath.
Fasten all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding
parts in case that terminal blocks screw off.
Electrical connections (such as plugs and cords) must be protected from potential hazardous environmental factors (e.g. foot
traffic, hitting objects).
Ensure that the unit case is properly earthed, connecting all the earth ground studs. Earth cable should be about 10mm longer
than the other cables on the connector, in such way that it won't be accidentally disconnected if the cable is stretched or pulled.
When leaving the unit unused for long periods, disconnect supply cables.

2

 


background image

1. 

Open the housing

Unscrew the four screws on the rear flange and remove it.
Be careful not to lose screws, washers and O-rings.

Screws

2. Prepare the housing to install the camera, sliding the upper rail away
from the lower rail.

Upper rail
Lower rail

3. 

Install the camera

Mount the camera on the internal rail using one of the ¼” screws supplied
and   the   plastic   washer.   Use   the   included   spacers   to   adjust   its   height
position. 
Slide the upper rail back on the lower rail into the housing
Feed the cables through the cable glands on the bottom and perform
electrical   and   video   connections   according   to   the   instructions   in   the
camera installation manual and, if necessary, in points 4 and 5.
Check the proper position of the seal in its groove on the rear flange.
Tighten the cable glands up till an 8 Nm torque ratio. 
Close the housing tightening the six screws on the rear flange to the main
body.

Cable glands

4. 

Only on housings with heater system.

Perform the input and output (to the camera) voltage connections using
the PCB installed inside the housing near the rear flange.

5. 

Only on housings with wash wiper system [110/240VAC]

Connect   correct   supply   voltage   between   the   BLUE   wire   (line)   and   the
WHITE wire (neutral).
Connecting the BLUE wire (line) to the GREEN wire, the wiper works until
the GREEN wire is disconnected, then the wiper parks itself to its initial
position.
A normally open switch, connected between the BLUE and GREEN wires,
can be used for this operation.

Only on housings with wash wiper system [24VAC/VDC]

Connect correct supply voltage between the GREEN wire (line) and the
GREY wire (GND).
Connecting the GREY wire (GND) to the BLUE wire, the wiper works until
the   BLUE   wire   is   disconnected,   then   the  wiper   parks  itself  to  its   initial
position.
A normally open switch, connected between the GREY and BLUE wires,
can be used for this operation.

Wiper wires

6. Use the screws at the bottom of the housing to fasten the housing to its
proper support.

Screws

3

 


background image

DIMENSIONS

    FRONTAL VIEW

SIDE VIEW

MAX INTERNAL DIMENSIONS [mm]
Model

Internal 

Ø 

204/204IRXX  

122x122x460

168

204-L/204IRXX-L  

122x122x560

168

204SHXX/204WWXX  

122x122x360

168

204SHXX-L/204WWXX-L  

122x122x460

168

Dimensions in brackets refer to models 204 with 600 mm tube length.

Available measures for ''A''
A = 

110

 mm for 204-110, 204-110-L, 204SH110 and 204SH110-L

A = 

70

 mm for 204IR70 and 204IR70-L (germanium window)

A = 

145 

mm for 204-145, 204-145-L, 204SH145 and 204SH145-L

A = 

110

 mm for 204IR110 and 204IR110-L (germanium window)

A = 

120

 mm for 204WW120 and 204WW120-L

A = 

145

 mm for 204IR145 and 204IR145-L (germanium window)

A = 

140

 mm for 204WW140 and 204WW140-L

Dimensions in millimetres – Tolerances according QMS – Design and product specifications subject to change without notice

Preserve this manual as a reference for future needs

.

 

Here you can find the always up-to-date pdf version of this document:

Used electrical, electronic and stainless steel products should not be mixed with general waste. 
For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national
legislation and the Directives 2002/95/EC and 2002/96/EC. 
By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health
and the environment which could otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old products, please contact your local municipality or your waste disposal service.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

The manufacturer declines all liability for any consequence resulting from improper installation practices, tampering or improper uses of the
product.

The descriptions and illustrations contained in this manual are not binding. The manufacturer reserves the right to make any alterations deemed
appropriate   for   the   technical,   manufacturing   and   commercial  improvement   of   the   product,  while  leaving   the   essential   product   features
unchanged, at any time and without undertaking to update the present publication.

TECNOVIDEO S.r.l.

Via San L. Murialdo, 8 36030 Villaverla (VI) ITALY

Tel. +39.0445.350444 Fax +39.0445.357259 

e-mail: info@tecnovideocctv.com – www.tecnovideocctv.com