PDF User Manual

  1. Home
  2. Manuals
  3. Techspan Rion Operating Instructions Manual

Techspan Rion Operating Instructions Manual

Made by: Techspan
Type: Operating Instructions
Category: Welding System
Pages: 2
Size: 0.74 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

T E C H S P A N   H O T   A I R   P L A S T I C   W E L D I N G   T O O L  

t y p e   R i o n   ‘ h e a v y - d u t y ’  

OPERATING INSTRUCTIONS 

Please read operating instructions carefully before use and keep for future reference. 

Power 

 

1600 

Voltage   

230 50/60Hz 

Temperature 

20 - 600 

Airflow   

l/min. 

230 

Noise 

 

dB 

60 

Weight   

kg 

1.4 with 3m cable 

Dimensions 

mm 

Handle 56mm, 

 

 

 

340x100 dia 

Electrical Safety :   

Double insulated 

Test Marks : 

 

CE 

 

 

 

Made in Switzerland 

T e c h n i c a l   D a t a  

Applications 

Plastic welding 

 

 

thermoplastics, pipes, profiles, sheet, moulded parts, flooring, tarpaulins, geomembranes, 
roofing membranes 
Heating   

 

forming, bending, expanding 
Drying 
water damp surfaces and joints 
Shrinking   

 

heat-shrink sleeves, film, tapes, solder sleeves, moulded shrink parts 
Ignition 
wood furnaces, coal furnaces 
Soldering 
soldering and desoldering 
Activating   

 

solvent-free adhesives, removal of self-adhesive labels / signwriting, hot-melt glue 
De-icing   

 

frozen parts, water pipes 

O P E R A T I N G   I N S T R U C T I O N S   -   T E C H S P A N   H O T   A I R   P L A S T I C   W E L D E R    

O P E R A T I N G   I N S T R U C T I O N S   -   T E C H S P A N   H O T   A I R   P L A S T I C   W E L D E R    

New Zealand:                                                                                               

P O Box 15262, New Lynn, Auckland                                                     
Ph: ++64 9 8276567  Fx: ++64 9 827 6596    
sales@techspanonline.com       

Australia:                                                                   

P O Box 1012, Mascot, NSW 1460, Sydney                   
Ph: 1-800 148 791   Fx: 1-800 148 799         
sales@techspanonline.com        

 

www.techspanonline.com 

New Zealand:                                                                                               

P O Box 15262, New Lynn, Auckland                                                     
Ph: ++64 9 8276567  Fx: ++64 9 827 6596    
sales@techspanonline.com       

Australia:                                                                   

P O Box 1012, Mascot, NSW 1460, Sydney                   
Ph: 1-800 148 791   Fx: 1-800 148 799         
sales@techspanonline.com        

 

www.techspanonline.com 

This Techspan tool is guaranteed for 2 years from the date of purchase against 
electrical breakdown or mechanical failure caused through defective material or 
workmanship, provided the failure is not the result of misuse. In the event of 
failure covered by this Guarantee, the tool must be returned freight paid to the 
supplier, with this card and proof of purchase, for inspection, and will be replaced 
or repaired at our option. Heating elements, and wearing parts, brushes, bearings 
etc are not covered by this guarantee.     

Type :                        

Techspan Rion Plastic Welder 1600W 230V 50Hz 

Date purchased : 
Customer : 
Supplied by : 

 

Techspan Group 

Guarantee 


background image

Description 

Nozzle (LE100303 plastic welding nozzle shown) 

Clamp screw for nozzle   

Element housing / protective sleeve 

Impellor housing 

Rubber tool rest 

Handle 

Potentiometer for temperature adjustment 

Mains cable 

Air filter 

10 

Potentiometer for temperature adjustment * 

11 

On/Off switch 

To operate the tool 

Fit appropriate nozzle (1,2) as required 

Connect tool to the mains 

Adjust hot air temperature by turning the potentiometer (10) 

Turn on switch (11) and allow tool to come up to temperature  (3 mins) 

After use always let the tool cool down 

For plastic welding training contact Techspan or approved service centre.   

        1    2  3   4   5                 6                  7  8                                  9         10  8  11 

O P E R A T I N G   I N S T R U C T I O N S   -   T E C H S P A N   H O T   A I R   P L A S T I C   W E L D E R    

O P E R A T I N G   I N S T R U C T I O N S   -   T E C H S P A N   H O T   A I R   P L A S T I C   W E L D E R    

New Zealand:                                                                                               

P O Box 15262, New Lynn, Auckland                                                     
Ph: ++64 9 8276567  Fx: ++64 9 827 6596    
sales@techspanonline.com       

Australia:                                                                   

P O Box 1012, Mascot, NSW 1460, Sydney                   
Ph: 1-800 148 791   Fx: 1-800 148 799         
sales@techspanonline.com        

 

www.techspanonline.com 

New Zealand:                                                                                               

P O Box 15262, New Lynn, Auckland                                                     
Ph: ++64 9 8276567  Fx: ++64 9 827 6596    
sales@techspanonline.com       

Australia:                                                                   

P O Box 1012, Mascot, NSW 1460, Sydney                   
Ph: 1-800 148 791   Fx: 1-800 148 799         
sales@techspanonline.com        

 

www.techspanonline.com 

The carbon brushes of the tool’s motor should be checked after about 1200 hours  

 

running time by your service centre. 

Repairs must be carried out by Techspan service centres. They guarantee a specialized and reliable 

 

repair service. 

The warranty will be void if repairs have not been carried out by a Techspan service centre using  

 

Techspan spare parts.      

Before changing nozzles, allow the tool to cool down, or use combination pliers 

Do not touch hot nozzle (1,2) and only place the nozzle on a heat resistant surface 

 

due to fire hazard. 

The nozzles are easily pushed onto the element housing (3) and are then secured by tightening the 

 

 clamp screw (2) with a screwdriver. 

Only Techspan nozzles and accessories should be used. 

Maintenance 

The welding tool’s air filter (9) must be cleaned with a brush if necessary. 

A wire brush should be used for cleaning the welding nozzle (1)  

Check power supply cable (8) along the full length, as well as the plug, for any possible electrical or 

 

mechanical damage. 

Accessories 

1       The Techspan plastic welder is supplied without nozzles, which are sold separately. 
2        Only Techspan nozzles and accessories should be used.  

Service and repairs 

Changing Nozzles 

Guarantee and Liability 

Guarantee and liability are in accordance with the guarantee certificate and the current terms and conditions 
of sale. Techspan rejects any guarantee claims for tools which are not in original condition. The tool must 
never be modified. 

Caution - Risk of Serious Injury and property damage 

Always lie the tool on a non-flammable surface & keep the hot air stream well away from combustible materials, includ-
ing combustible materials hidden behind ceilings, walls, cavities or floors. Do not point the hot air stream at the same 
spot for extended periods. Incorrect use can cause fire. Do not touch the element housing or nozzle with any part of the 
body during use as they get very hot and there is a danger of serious injury by burning. When working with plastics, 
varnish or similar materials vapours/gases/smoke develop which can be harmful. Do not breathe in vapours/gasses/
smoke as they can be highly toxic. Always provide good ventilation of the working area with an extraction system and/or 
wear a respirator. Keep the unit dry. Do not use in the rain or in damp conditions. Always store the unit in a dry place.            

*Setting  Deg. C 

90 

150 

200 

270 

310 

370 

430 

490 

540 

10 

600