VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
1. General information about our surface storage heaters
With our variety of electric surface storage heaters, you can find the right solution
for your needs in any spatial situation. The TECHNOTHERM partial thermal-stor-
age heaters are available as additional or transitional heating for all rooms in
the living area, with the exception of the special cases stated in the safety in-
structions. They are designed for continuous operation. Prior to dispatch, all our
products undergo an extensive function, safety and quality test. We guarantee
a constructive design complying with all currently applicable international, Eu-
ropean and German safety standards and rules. You can see this in the labelling
of our products with the well-known certification marks: “TÜV-GS”, “SLG-GS”,
“Keymark” and “CE”. Our heaters are evaluated in accordance with the interna-
tionally applicable lEC-regulations. The manufacture of our heaters is constantly
supervised by a state-accredited test centre.
This heater can be used by children aged from 8 years and above and by phys-
ically, sensory or mentally restricted persons if they are supervised or given in-
structions on safe use and understand the hazards involved as it does not require
any experience or knowledge. This device is not a toy for children to play with!
Cleaning and user maintenance shall not be carried out by children without su-
pervision. The use of heat radiators is to be given a particular duty of care by su-
pervisors. Children under the age of 3 are to be kept away unless they are contin-
ually supervised. Children between the age of 3 and 8 are only allowed to switch
the heater on or off if they are supervised or given instructions on safe use and
understand the hazards involved, provided that it has been placed or installed in
its intended normal operating position. Children between the age of 3 and 8 shall
not plug in, regulate and clean the heater or perform user maintenance.
Caution: Some parts of the product can become very hot and cause burns. Pay
particular attention when children and vulnerable people are present
Warning! this device has to be grounded
This device may only be operated using alternating current and the operating voltage indicated on
the power rating plate
•
Nominal Voltage 230V AC, 50 Hz
•
Protection Class I
•
Degree of Protection IP 24
•
Room Thermostat 7°C till 30°C

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
2.1 User Manuel VPS RF Model
2.1.1 Setting the Room Thermostat
Press the
receiver button
for more than 3 seconds, until the indicator light begins to flash. Subsequent-
ly press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indi-
cator light stops flashing the two products are assigned.
2.1.2 Setting the sender
Press the receiver button for at least 3 seconds until the indicator light starts flashing.
Two modes of operation are possible.
Slow flashing:
On\Off switch
Fast flashing:
instigator
To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see
user manual transmitter). Check that the indicator light is no longer flashing.
Application Example
The use of a room thermostat in combination with a opening detector is ideal, because the opening de-
tector will detect if a window is open and will automatically switch to frost protection. By pressing the
receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting
is changed as soon as the signal light stops flashing.
2.1.3 Deleting Allocations
To delete the setting simply press the receiver key for approximately 30 seconds until you see the recei-
ver light flash briefly. All transmitters are now deleted.
2.1.4 Receiver RF- Technical Specifications
•
Power Supply 230 V, 50 Hz +/-10%
•
Protection Class II
•
Expenditure : 0,5 VA
•
Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
•
Radio Frequency 868 MHz (NormEN 300 220),
•
Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the construction of
the building and the electromagnetic interference
•
Maximal Number of receivers: 8
•
Mode of operation: type 1.C (Micro-disconnection)
•
Operating Temperature: -5°C to +50°C
•
Storage Temperature: -10 °C +70°C
•
Dimensions: 120 x 54 x 25 mm
•
Degree of Protection : IP 44 - IK 04
•
To be installed in average polluted Areas4. Installation DSM Thermoastat / DAS Schnittstelle.

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove all
protective coverage before turning on the device. When using the device for the first time you
might detect a strong odor. This is no reason for concern; it is caused by residues of production
and will disappear shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other
heating device as well. Only a qualified electrician may open or remove the device from the power
supply.
3. User Manuel for the VPS DSM
Please see additional manual at www.lucht-lhz.de/lhz-app-gb.html and download the manual
4. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
5. Details for operation of Types VPS plus /VPS H plus/VPS TDI
Digital control display
TDI
–
“
plus
”
Thermostat
Mounting
Mounted on the side of the radiator using
screws.
Connection
Connection on the radiator’s power card.
Adjustment
buttons
part to connect to
the power card
réf : 7709936
On / Off
/
mode
Configuration
Menu 3: Backlight time out setting
The time out can be adjusted between 0
and 225 seconds, in steps of 15 seconds
(set on 90 seconds by default).
To modify, press on the + or - buttons then
press OK to confirm and go to the next setting.
When in Off mode,
press and hold down the On/Off button
for 10 seconds to access the first configuration
menu.
>10 sec.
Menu 4: AUTO mode temperature display option
Menu 1:ECO set-point adjustment
By default, Economy setting = Comfort setting - 3.5°C.
0 = Continuous display of room temperature.
1 = Continuous display of set-point temperature.
To modify, press on the + or - buttons then
press OK to confirm and go to the next setting.
This reduction can be set between
0 to -10°C, in steps of 0.5°C.
Menu number
To adjust the reduction, press on
the + or - buttons then press OK to confirm
and go to the next setting.
Menu 5: Product number
This menu allows you to view the product
number.
To allow the user to modify the set-point, press
on the + button in Economy mode until “----” is
displayed on the screen.
To exit the configuration mode, press OK.
Menu 2: Correction of the measured temperature
If there is a difference between the temperature noted
(thermometer) and the temperature measured and displayed by
the unit, menu 2 acts on the measurement of the probe so as to
compensate for this difference (from -5°C to +5°C in steps of
0.1°C).
To modify, press on the + or - buttons then press
OK to confirm and go to the next setting.

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
Time Setting
Use
Continuous Frost Protection
Day
In Off mode, press the
The days flash.
mode
button.
Hours
Pressing and holding the + or - buttons lets you
change the current set-point (+5 to +15°C) in
steps of 0.5°C.
Press + or - to set the day, then press OK
to confirm and go on to set the hour and then
the minutes.
Minutes
Press the
mode
button once to access the pro-
gramming, and press the On/Off button once to exit the
setting mode.
AUTOMATIC mode
In this mode the device follows the programming
set.
To modify the programming, press the
PROG
button once.
Programming
When starting up, the “Comfort mode from 8am
to 10pm” program is applied to all the days of
the week.
Timer mode
To set a set-point temperature for a certain
To change the programming, press the
PROG
button in Off or AUTO mode.
The 1
st
time slot flashes on and off.
period of time, press on the button once.
To set the temperature you want (+5°C to
+30°C), use the + and - buttons, then press OK
to confirm and go on to set the duration.
To set the duration you want (30 min
to 72 hours, in steps of 30 min), use
Day
the + and – buttons (e.g. 1 hr 30 min), then press OK.
To cancel the timer mode, press on the OK button.
Program
profile
Confirm
and go to
the next day
Frost protection
mode for 1 hour
1
st
time
slot
Comfort
mode for 1 hour
Absence mode
You can set your device to Frost protection
mode for a period between 1 and 365 days,
Economy
mode for 1 hour
by pressing on the
button.
Quick programming:
To apply the same program to the following day, press and hold
the OK button for approximately 3 seconds until the program of
the following day is displayed.
To exit the programming mode, press on the On/Off button.
To set the number of days of absence,
press on the + or – buttons, then confirm by
pressing OK.
To cancel this mode, press on the OK button
again.
Use
The Mode button allows you to select the different operating
Locking the keypad
If you press and hold the central buttons
simultaneously during 5 seconds, it enables
you to lock the keypad. A key symbol appears
briefly on the display.
To unlock the keypad, press simultaneously on
the central buttons.
modes:
Comfort,
Economy,
Frost protection,
programming
AUTO
mode.
Pressing the
i
button gives you the temperature of the room
or the set-point temperature, according to your configuration
settings in menu 5.
If the
ON
icon is displayed, this means that the device is in
heating demand mode.
Once the keypad is locked, the key symbol
appears briefly if you press on a button.
Continuous Comfort
Pressing and holding the + or - buttons lets you
change the current set-point (+5 to +30°C) in
steps of 0.5°C.
Continuous Economy mode
The Economy set-point is indexed according to
the Comfort set-point. The reduction can be
modified in the configuration settings for menu 1.
Modifying the Economy set-point
The set-point can be modified if it was authorized
in the configuration settings in menu 1 (“----”).
Pressing and holding the + or - buttons lets you
change the current set-point (+5 to +30°C) in
steps of 0.5°C.
Menu 5: Open Window detection
The detection of an open window occurs
when the room temperature falls rapidly.
In this case, the display shows a flashing
pictogram, as well as the frost
protection set-point temperature.
0 = Open window detection is deactivated
1 = Open window detection is activated
To modify, press on the + or – buttons,
then press OK to confirm and to go to the
next setting.
Please note: an open window cannot be
detected in OFF-Mode.
This feature can be temporarily interrupted
by pressing on .

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
Technical characteristics
• Power supplied by the power card
• Dimensions in mm (without mounting lugs):
H = 71.7, W = 53, D= 14.4
• Screw-mounted
• Install in an environment with normal pollution levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
Menu 6: Adaptive start control
This feature enables to reach the set-point
temperature at a set time.
When this feature is activated, the display shows a
flashing .
0 = Adaptive start control deactivated
1 = Adaptive start control activated
To modify, press on the + or – buttons, then press
OK to confirm and to go to the next setting.
Adjusting the time-temperature-slope (when
adaptive start control is activated)
From 1°C to 6°C, in steps of 0.5°C.
If the set-point temperature is reached too early,
then a lower value should be set.
If the set-point temperature is reached too late,
then a higher value should be set.
Menu 7: Productnumber
This menu allows you to view the product
number.
To exit the configuration mode, press OK.

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
6.1 Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this ma-
nual to any other succeeding owner of the device. The device comes with a power plug that has to be
plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
7.1 Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials
can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible fire hazard the safety distances are observed during assembly:
Side walls of the heater to any masonry:
5 cm
Side walls of the heater to combustible materials: 10 cm
Distance radiator to the floor:
25 cm
arranged spaced upper radiator limit to about components or covers (. Eg window):
flammable 15 cm
nonflammable 10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance
when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore
there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof
slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a
shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration
on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw
the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and
the wall.
Hang the device in the two or three fittings and tighten it down. See also the additional mounting infor-
mation at the following pages!

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
8.2 Wall Mounting
Type
Power
[Watt]
With
A
High
B
Deep
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
I
Weight
[kg]
VPS
1000
1000
750
450
85
442
140
375
250
115
375
11,5
VPS
1200
1200
750
450
85
442
140
375
250
115
375
11,5
VPS
1500
1500
1050
450
85
740
140
375
250
115
525
15,0
VPS
2000
2000
1050
450
85
740
140
375
250
115
525
15,0

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
9. Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC)
50 Hz. The electrical installation may only be performed according to the user manual and only by a
qualified Electrician. The device was designed to be used with termination and the connection cable
has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connection line may
not touch the device at any time.
10. Regulation
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the
Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room
temperature controllers that fulfill the following functions:
•
electronic room temperature control
and has at least one of the following properties:
•
room temperature control, with presence detection
•
room temperature control, with open window detection
•
with distance control option
•
with adaptive start control
The following room temperature controller systems
•
RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface
(Art.Nr.750 000 640) or
•
DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)
•
TDI- Thermostat / plus-Thermostat
from Technotherm meet the following requirements and therefore the ErP Directive:
•
electronic room temperature control plus week timer (RF/DSM/TDI)
•
room temperature control, with open window detection (DSM/plus/TDI)
•
with distance control option (DSM/RF)
•
with adaptive start control (DSM/plus/TDI)
Use of the VPS / VP Standard range (without external/internal thermostat control) is only permit-
ted on feet.
Installation of the receiver and the interfaces see separate instructions. For customer service - see last
page.
Failure to comply with these requirements will result in the loss of the CE mark.

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
9. Additional wall mounting information
1. Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall
2. Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed
“automatically”.
Topside of heater
Wallmount:
fixing with 3 screw!
mount locked!
Underside detailview
Press a screwdriver
into the groove to
unlock the mount.
mount is unlocked
Switch of the Heater from the
Wallmounting
1.
Press the screwdriver into
the groove.
2. Remove the Heater from the
Wall
Wall

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
11.Information requirements for electrical local space heaters
Type: VPS RF (additional TPF Thermostat and Eco-Interface otionally necessary) / VPS plus RF
plus
Item
Symbol
Value
Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000
1200
1500
2000
Watt
manual heat charge control, with integrated thermostat
NO
NO
Minimum heat
output (indicative)
P
min
1000
1200
1500
2000
Watt
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
NO
Maximum conti-
nuous heat output
P
max,c
1000
1200
1500
2000
Watt
electronic heat charge control with room and/or outdoor
temperature feedback
NO
NO
Auxiliary electricity
consumption
fan assisted heat output
NO
NO
At nominal heat
output
el
max
1000
1200
1500
2000
Watt
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
2.0
2.0
2.0
2.0
Watt
single stage heat output and no room temperature control
NO
NO
In standby mode
el
SB
<0,5
<0,5
<0,5
<0,5
Watt
Two or more manual stages, no room temperature control
NO
NO
with mechanic thermostat room temperature control
NO
NO
with electronic room temperature control
NO
NO
electronic room temperature control plus day timer
NO
NO
electronic room temperature control plus week timer
YES
YES
Other control options (multiple selections possible)
room temperature control, with presence detection
NO
NO
room temperature control, with open window detection
NO
YES
with distance control option
YES
YES
with adaptive start control
NO
YES
with working time limitation
NO
NO
with black bulb sensor
NO
NO

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
Type: VPS
Item
Symbol
Value
Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000
1200
1500
2000
Watt
manual heat charge control, with integrated thermostat
NO
Minimum heat
output (indicative)
P
min
1000
1200
1500
2000
Watt
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum conti-
nuous heat output
P
max,c
1000
1200
1500
2000
Watt
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumption
fan assisted heat output
NO
At nominal heat
output
el
max
1000
1200
1500
2000
Watt
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
<0,5
<0,5
<0,5
<0,5
Watt
single stage heat output and no room temperature control
NO
In standby mode
el
SB
<0,5
<0,5
<0,5
<0,5
Watt
Two or more manual stages, no room temperature control
NO
with mechanic thermostat room temperature control
NO
with electronic room temperature control
YES
electronic room temperature control plus day timer
NO
electronic room temperature control plus week timer
NO
Other control options (multiple selections possible)
room temperature control, with presence detection
NO
room temperature control, with open window detection
NO
with distance control option
NO
with adaptive start control
NO
with working time limitation
NO
with black bulb sensor
NO
Type: VPS DSM (additional DSM interface optionally necessary)
Item
Symbol
Value
Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000
1200
1500
2000
Watt
manual heat charge control, with integrated thermostat
NO
Minimum heat
output (indicative)
P
min
1000
1200
1500
2000
Watt
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum conti-
nuous heat output
P
max,c
1000
1200
1500
2000
Watt
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumption
fan assisted heat output
NO
At nominal heat
output
el
max
1000
1200
1500
2000
Watt
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
0,8
0,8
0,8
0,8
Watt
single stage heat output and no room temperature control
NO
In standby mode
el
SB
0,8
0,8
0,8
0,8
Watt
Two or more manual stages, no room temperature control
NO
with mechanic thermostat room temperature control
NO
with electronic room temperature control
NO
electronic room temperature control plus day timer
NO
electronic room temperature control plus week timer
YES
Other control options (multiple selections possible)
room temperature control, with presence detection
NO
room temperature control, with open window detection
YES
with distance control option
YES
with adaptive start control
YES
with working time limitation
NO
with black bulb sensor
NO

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB

Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
Technotherm is a label from Lucht LHZ GmbH & Co. KG
Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany
Phone: +49 3724 66869 0
Telefax: +49 3724 66869 20
info@technotherm.de | www.technotherm.de
Technical alternations, errors, omissions and errata reserved. Dimensions
are stated without warranty!
Updated: august 18
TECHNOTHERM After-sales service:
Ph. +49 (0) 911 937 83 210