VPS DSM series\ VPS H series\ VPS plus series\ VPS 1000\ VPS 1500\ VPS 1200\ VPS RF Wall series\ VPS 2000\ VPS H 1000\ VPS H 1200\ VPS DSM 1000\ VPS DSM 1200\ VPS DSM 1500\ VPS DSM 2000\ VPS RF 1200\ VPS RF 1500\ VPS RF 1000\ VPS plus 1000\ VPS RF 2000\ VPS plus 1500\ VPS plus 1200\ VPS plus 2000\ TDI-Plus

Made by: Technotherm
Type: Operating Instructions
Category: Heater
Pages: 16
Size: 1.73 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

     VPS  / VPS H / VPS DSM / VPS plus / VPS RF  Wall

 

Please read attentively and keep in a safe place!  

Subject to alterations! 

Id_no. 911 360 870

Issue 08/18

Types:

•  VPS 1000

•  VPS 1200

•  VPS 1500

•  VPS 2000

•  VPS H 1000

•  VPS H 1200

•  VPS DSM 1000

•  VPS DSM 1200

•  VPS DSM 1500

•  VPS DSM 2000

 

•  VPS RF 1000

•  VPS RF 1200

•  VPS RF 1500

•  VPS RF 2000

•  VPS plus 1000

•  VPS plus 1200

•  VPS plus 1500

•  VPS plus 2000

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

1. General information about our surface storage heaters

With our variety of electric surface storage heaters, you can find the right solution 

for your needs in any spatial situation. The TECHNOTHERM partial thermal-stor-

age heaters are available as additional or transitional heating for all rooms in 

the living area, with the exception of the special cases stated in the safety in-

structions. They are designed for continuous operation. Prior to dispatch, all our 

products undergo an extensive function, safety and quality test. We guarantee 

a constructive design complying with all currently applicable international, Eu-

ropean and German safety standards and rules. You can see this in the labelling 

of our products with the well-known certification marks: “TÜV-GS”, “SLG-GS”, 

“Keymark” and “CE”. Our heaters are evaluated in accordance with the interna-

tionally applicable lEC-regulations. The manufacture of our heaters is constantly 

supervised by a state-accredited test centre.

This heater can be used by children aged from 8 years and above and by phys-

ically, sensory or mentally restricted persons if they are supervised or given in-

structions on safe use and understand the hazards involved as it does not require 

any experience or knowledge. This device is not a toy for children to play with! 

Cleaning and user maintenance shall not be carried out by children without su-

pervision. The use of heat radiators is to be given a particular duty of care by su-

pervisors. Children under the age of 3 are to be kept away unless they are contin-

ually supervised. Children between the age of 3 and 8 are only allowed to switch 

the heater on or off if they are supervised or given instructions on safe use and 

understand the hazards involved, provided that it has been placed or installed in 

its intended normal operating position. Children between the age of 3 and 8 shall 

not plug in, regulate and clean the heater or perform user maintenance.

Caution: Some parts of the product can become very hot and cause burns. Pay 

particular attention when children and vulnerable people are present

Warning! this device has to be grounded

This device may only be operated using alternating current and the operating voltage indicated on 

the power rating plate

• 

Nominal Voltage            230V AC, 50 Hz

• 

Protection Class            I

• 

Degree of Protection     IP 24

• 

Room Thermostat         7°C till 30°C

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

2.1 User Manuel VPS RF Model
2.1.1 Setting the Room Thermostat

Press the 

receiver button

 for more than 3 seconds, until the indicator light begins to flash. Subsequent-

ly press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indi-

cator light stops flashing the two products are assigned.

2.1.2 Setting the sender

Press  the  receiver  button  for  at  least  3  seconds  until  the  indicator  light  starts  flashing.

 

Two modes of operation are possible.

Slow flashing:    

On\Off switch

 

Fast flashing:    

instigator

To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see 

user manual transmitter). Check that the indicator light is no longer flashing.

Application Example

The use of a room thermostat in combination with a opening detector is ideal, because the opening de-

tector will detect if a window is open and will automatically switch to frost protection. By pressing the 

receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting 

is changed as soon as the signal light stops flashing. 

2.1.3 Deleting Allocations

To delete the setting simply press the receiver key for approximately 30 seconds until you see the recei-

ver light flash briefly. All transmitters are now deleted.

2.1.4 Receiver RF- Technical Specifications

• 

Power Supply 230 V, 50 Hz +/-10%

• 

Protection Class II

• 

Expenditure : 0,5 VA

• 

Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control

• 

Radio Frequency 868 MHz (NormEN 300 220),

• 

Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the construction of 

the building and the electromagnetic interference

• 

Maximal Number of receivers: 8

• 

Mode of operation: type 1.C (Micro-disconnection)

• 

Operating Temperature: -5°C to +50°C

• 

Storage Temperature: -10 °C +70°C

• 

Dimensions: 120 x 54 x 25 mm

• 

Degree of Protection : IP 44 - IK 04

• 

To be installed in average polluted Areas4. Installation DSM Thermoastat / DAS Schnittstelle.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

WARNING

Do not install this device in areas that present an explosion hazard like a garage. Remove all 

protective coverage before turning on the device. When using the device for the first time you 

might detect a strong odor. This is no reason for concern; it is caused by residues of production 

and will disappear shortly.

The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other 

heating device as well. Only a qualified electrician may open or remove the device from the power 

supply.

3. User Manuel for the VPS DSM

Please see additional manual at www.lucht-lhz.de/lhz-app-gb.html and download the manual

4. Maintenance

Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

5. Details for operation of Types VPS plus /VPS H plus/VPS TDI

Digital control display  

TDI 

 

plus

 Thermostat 

 Mounting 

Mounted on the side of the radiator using 

screws. 

 Connection 

Connection on the radiator’s power card. 

Adjustment 

buttons

 

part to connect to 

the power card 

réf : 7709936

 

On / Off

 

mode

 

 Configuration 

Menu 3: Backlight time out setting 

The time out can be adjusted between 0 

and 225 seconds, in steps of 15 seconds 

(set on 90 seconds by default). 

To modify, press on the + or - buttons then 

press OK to confirm and go to the next setting. 

When in Off mode, 

press and hold down the On/Off button 

for 10 seconds to access the first configuration 

menu. 

>10 sec.

Menu 4: AUTO mode temperature display option 

Menu 1:ECO set-point adjustment 

By default, Economy setting = Comfort setting - 3.5°C. 

0 = Continuous display of room temperature. 
1 = Continuous display of set-point temperature. 
To modify, press on the + or - buttons then 

press OK to confirm and go to the next setting. 

This reduction can be set between 

0 to -10°C, in steps of 0.5°C. 

Menu number

 

To adjust the reduction, press on 

the + or - buttons then press OK to confirm 

and go to the next setting. 

Menu 5: Product number 

This menu allows you to view the product 

number. 

To allow the user to modify the set-point, press 

on the + button in Economy mode until “----” is 

displayed on the screen. 

To exit the configuration mode, press OK. 

Menu 2: Correction  of  the measured temperature 

If there is a difference between the temperature noted 

(thermometer) and the temperature measured and displayed by 

the unit, menu 2 acts on the measurement of the probe so as to 

compensate for this difference (from -5°C to +5°C in steps of 

0.1°C). 

To modify, press on the + or - buttons then press 

OK to confirm and go to the next setting. 

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

 Time  Setting 

 Use 

Continuous Frost Protection 

Day

 

In Off mode, press the 

The days flash. 

mode 

button. 

Hours

 

Pressing and holding the + or - buttons lets you 

change the current set-point (+5 to +15°C) in 

steps of 0.5°C. 

Press + or - to set the day, then press OK 

to confirm and go on to set the hour and then 

the minutes. 

Minutes

 

Press the

 mode 

button once to access the pro- 

gramming, and press the On/Off button once to exit the 

setting mode. 

AUTOMATIC mode 

In this mode the device follows the programming 

set. 

To modify the programming, press the 

PROG 

button once. 

 Programming 

When starting up, the “Comfort mode from 8am 

to 10pm” program is applied to all the days of 

the week. 

Timer mode 

To set a set-point temperature for a certain 

To change the programming, press the 

PROG 

button in Off or AUTO mode. 

The 1

st 

time slot flashes on and off. 

period of time, press on the  button once. 

To set the temperature you want (+5°C to 

+30°C), use the + and - buttons, then press OK

to confirm and go on to set the duration.

To set the duration you want (30 min

to 72 hours, in steps of 30 min), use

Day

 

the + and – buttons (e.g. 1 hr 30 min), then press OK.

To cancel the timer mode, press on the OK button.

Program 

profile

 

Confirm 

and go to 

the next day

 

Frost protection 

mode for 1 hour

 

1

st 

time

 

slot

 

Comfort 

mode for 1 hour

 

Absence mode 

You can set your device to Frost protection 

mode for a period between 1 and 365 days, 

Economy 

mode for 1 hour

 

by pressing on the 

button. 

Quick programming: 

To apply the same program to the following day, press and hold 

the OK button for approximately 3 seconds until the program of 

the following day is displayed. 

To exit the programming mode, press on the On/Off button. 

To set the number of days of absence, 

press on the + or – buttons, then confirm by 

pressing OK. 
To cancel this mode, press on the OK button 

again. 

 Use 

The Mode button allows you to select the different operating 

Locking the keypad 

If you press and hold the central buttons 

simultaneously during 5 seconds, it enables 

you to lock the keypad. A key symbol appears 

briefly on the display. 

To unlock the keypad, press simultaneously on 

the central buttons. 

modes: 

Comfort, 

Economy, 

Frost protection, 

programming 

AUTO 

mode. 

Pressing the 

button gives you the temperature of the room 

or the set-point temperature, according to your configuration 

settings in menu 5. 
If the 

ON 

icon is displayed, this means that the device is in 

heating demand mode. 

Once the keypad is locked, the key symbol 

appears briefly if you press on a button. 

Continuous Comfort 

Pressing and holding the + or - buttons lets you 

change the current set-point (+5 to +30°C) in 

steps of 0.5°C. 

Continuous Economy mode 

The Economy set-point is indexed according to 

the Comfort set-point. The reduction can be 

modified in the configuration settings for menu 1. 

Modifying the Economy set-point 

The set-point can be modified if it was authorized 

in the configuration settings in menu 1 (“----”). 
Pressing and holding the + or - buttons lets you 

change the current set-point (+5 to +30°C) in 

steps of 0.5°C. 

                                                              

Menu 5: Open Window detection 

The detection of an open window occurs 

when the room temperature falls rapidly.  

In this case, the display shows a flashing 

 pictogram, as well as the frost 

protection set-point temperature.   

0 = Open window detection is deactivated 

1 = Open window detection is activated  

To modify, press on the + or – buttons, 

then press OK to confirm and to go to the 

next setting.  

Please note: an open window cannot be 

detected in OFF-Mode.  

This feature can be temporarily interrupted 

by pressing on  . 

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

 Technical characteristics 

• Power supplied by the power card
• Dimensions in mm (without mounting lugs):

H = 71.7, W = 53, D= 14.4

• Screw-mounted
• Install in an environment with normal pollution levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C

Menu 6: Adaptive start control 

This feature enables to reach the set-point 

temperature at a set time.  

When this feature is activated, the display shows a 

flashing  .  

0 = Adaptive start control deactivated 

1 = Adaptive start control activated 

To modify, press on the + or – buttons, then press 

OK to confirm and to go to the next setting.  

Adjusting the time-temperature-slope (when 

adaptive start control is activated) 

From 1°C to 6°C, in steps of 0.5°C. 

If the set-point temperature is reached too early, 

then a lower value should be set. 

If the set-point temperature is reached too late, 

then a higher value should be set.  

Menu 7: Productnumber 

This menu allows you to view the product 

number. 

To exit the configuration mode, press OK. 

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

6.1 Assembly instruction

This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this ma-

nual to any other succeeding owner of the device. The device comes with a power plug that has to be 

plugged into an outlet.

The device is designed to be connected to 230V (nominal) alternating current (AC).

7.1 Wall Installation

When installing the device, the safety distance must be strictly adhered to, so that flammable materials 

can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.

• Due to possible fire hazard the safety distances are observed during assembly:

Side walls of the heater to any masonry: 

 

 5 cm

Side walls of the heater to combustible materials:   10 cm

Distance radiator to the floor:  

 

 

25 cm

arranged spaced upper radiator limit to about components or covers (. Eg window):

  

 

 

 

 

flammable   15 cm

  

 

 

 

 

nonflammable 10 cm

To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance 

when installing the device. Mount the device to a wall that is fireproof up to 90 °C.

The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore 

there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof 

slopes and ceilings.

If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a 

shower or a bath.

When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration 

on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw 

the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and 

the wall.

Hang the device in the two or three fittings and tighten it down. See also the additional mounting infor-

mation at the following pages!

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

8.2 Wall Mounting

Type

Power
[Watt]

With

A

High

B

Deep

C

[mm]

D

[mm]

E

[mm]

F

[mm]

G

[mm]

H

[mm]

I

Weight

[kg]

VPS 

1000

1000

750

450

85

442

140

375

250

115

375

11,5

VPS

1200

1200

750

450

85

442

140

375

250

115

375

11,5

VPS

1500

1500

1050

450

85

740

140

375

250

115

525

15,0

VPS

2000

2000

1050

450

85

740

140

375

250

115

525

15,0

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

9. Installation of Electricity

The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC) 

50 Hz. The electrical installation may only be performed according to the user manual and only by a 

qualified Electrician. The device was designed to be used with termination and the connection cable 

has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)

The distance between the receptacle and the device hast to be at least 10cm. The connection line may 

not touch the device at any time.

10. Regulation

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the 

Ecodesign requirements 2015/1188.

 

The installation and commissioning of the devices is only permitted in conjunction with external room 

temperature controllers that fulfill the following functions:

 

• 

electronic room temperature control

 

and has at least one of the following properties:

 

• 

room temperature control, with presence detection

• 

room temperature control, with open window detection

• 

with distance control option

• 

with adaptive start control

The following room temperature controller systems

• 

RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface 

(Art.Nr.750 000 640) or

• 

DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)

• 

TDI- Thermostat / plus-Thermostat

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

• 

electronic room temperature control plus week timer (RF/DSM/TDI)

• 

room temperature control, with open window detection (DSM/plus/TDI) 

• 

with distance control option (DSM/RF)

• 

with adaptive start control (DSM/plus/TDI)

Use of the VPS / VP Standard range (without external/internal thermostat control) is only permit-

ted on feet.

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page.

 

Failure to comply with these requirements will result in the loss of the CE mark.

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

9. Additional wall mounting information

1. Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall 

2. Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed 

“automatically”.

Topside of heater

Wallmount:

fixing with 3 screw!

mount locked!

Underside detailview

Press a screwdriver 

into the groove to 

unlock the mount.

mount is unlocked

Switch  of  the  Heater  from  the 

Wallmounting

1. 

Press  the  screwdriver  into 

the groove.

2.  Remove the Heater from the 

Wall

Wall

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

11.Information requirements for electrical local space heaters

Type: VPS RF (additional TPF Thermostat and Eco-Interface otionally necessary) / VPS plus                                                                                                                                    RF

plus

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat 

output

P

nom

1000

1200

1500

2000

Watt

manual heat charge control, with integrated thermostat

NO

NO

Minimum heat

output (indicative)

P

min

1000

1200

1500

2000

Watt

manual heat charge control with room and/or outdoor tempera-

ture feedback

NO

NO

Maximum conti-

nuous heat output

P

max,c

1000

1200

1500

2000

Watt

electronic heat charge control with room and/or outdoor

temperature feedback

NO

NO

Auxiliary electricity 

consumption

fan assisted heat output

NO

NO

At nominal heat

output

el

max

1000

1200

1500

2000

Watt

Type of heat output/room temperature control (select

one)

At minimum heat 

output

el

min

2.0

2.0

2.0

2.0

Watt

single stage heat output and no room temperature control

NO

NO

In standby mode

el

SB

<0,5

<0,5

<0,5

<0,5

Watt

Two or more manual stages, no room temperature control

NO

NO

with mechanic thermostat room temperature control

NO

NO

with electronic room temperature control

NO

NO

electronic room temperature control plus day timer

NO

NO

electronic room temperature control plus week timer

YES

YES

Other control options (multiple selections possible)

room temperature control, with presence detection

NO

NO

room temperature control, with open window detection

NO

YES

with distance control option

YES

YES

with adaptive start control

NO

YES

with working time limitation

NO

NO

with black bulb sensor

NO

NO

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

Type: VPS

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat 

output

P

nom

1000

1200

1500

2000

Watt

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

1000

1200

1500

2000

Watt

manual heat charge control with room and/or outdoor tempera-

ture feedback

NO

Maximum conti-

nuous heat output

P

max,c

1000

1200

1500

2000

Watt

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electricity 

consumption

fan assisted heat output

NO

At nominal heat

output

el

max

1000

1200

1500

2000

Watt

Type of heat output/room temperature control (select

one)

At minimum heat 

output

el

min

<0,5

<0,5

<0,5

<0,5

Watt

single stage heat output and no room temperature control

NO

In standby mode

el

SB

<0,5

<0,5

<0,5

<0,5

Watt

Two or more manual stages, no room temperature control

NO

with mechanic thermostat room temperature control

NO

with electronic room temperature control

YES

electronic room temperature control plus day timer

NO

electronic room temperature control plus week timer

NO

Other control options (multiple selections possible)

room temperature control, with presence detection

NO

room temperature control, with open window detection

NO

with distance control option

NO

with adaptive start control

NO

with working time limitation

NO

with black bulb sensor

NO

Type: VPS DSM  (additional DSM interface optionally necessary)

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat 

output

P

nom

1000

1200

1500

2000

Watt

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

1000

1200

1500

2000

Watt

manual heat charge control with room and/or outdoor tempera-

ture feedback

NO

Maximum conti-

nuous heat output

P

max,c

1000

1200

1500

2000

Watt

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electricity 

consumption

fan assisted heat output

NO

At nominal heat

output

el

max

1000

1200

1500

2000

Watt

Type of heat output/room temperature control (select

one)

At minimum heat 

output

el

min

0,8

0,8

0,8

0,8

Watt

single stage heat output and no room temperature control

NO

In standby mode

el

SB

0,8

0,8

0,8

0,8

Watt

Two or more manual stages, no room temperature control

NO

with mechanic thermostat room temperature control

NO

with electronic room temperature control

NO

electronic room temperature control plus day timer

NO

electronic room temperature control plus week timer

YES

Other control options (multiple selections possible)

room temperature control, with presence detection

NO

room temperature control, with open window detection

YES

with distance control option

YES

with adaptive start control

YES

with working time limitation

NO

with black bulb sensor

NO

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

 


background image

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS devices

Feel good through warmth from electricity - www.technotherm.de 

GB 

Technotherm is a label from Lucht LHZ GmbH & Co. KG

Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany

Phone:  +49 3724 66869 0

Telefax:   +49 3724 66869 20

info@technotherm.de | www.technotherm.de

Technical alternations, errors, omissions and errata reserved. Dimensions

are stated without warranty! 

Updated: august 18

TECHNOTHERM After-sales service:

Ph. +49 (0) 911 937 83 210