Full Text Searchable PDF User Manual

Feel good through warmth from electricity - www.technotherm.de
Types:
• VPS- Design B 1000 - 2000 RF
• VPS- Design W 1000 - 2000 RF
• VPS- Design B/W 1200 H RF
Installation and Operating Instructions
VPS Design
Please read attentively and keep in a safe place!
Subject to alterations!
Id_no. 911 361 911
Issue 04/18

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
1. For your safety
• This appliance is intended for normal household use and not for use for vehicles or on board
ships or aircrafts.
• This appliance can be used by children aged from 8 years and above and persons with re-
duced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without supervision.
•
Children of less than 3 years should be kept away unless continuously supervised.
•
Children aged from 3 years and less than 8 years shall only switch on/off the appliance pro
-
vided that it has been placed or installed in its intended normal operating position and they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children aged from 3 years and less than 8 years shall not
plug in, regulate and clean the appliance or perform user maintenance.
• CAUTION — Some parts of this product can become very hot and cause burns. Particular
attention has to be given where children and vulnerable people are present.
•
Make sure that your supply rating corresponds to what specified on the rating plate: 230V~,
50Hz.
•
During function, place the heater in a safe position:
- at least 1m far from inflammable objects or furnitures;
- leaving not less than 1m of free space in front of the heater;
- not located immediately below a socket-outlet.
•
Do not leave animals or children touch or play with the appliance.
•
Do not use the heater in rooms with explosive gas or while using inflammable solvents or
varnish or glues.
•
If the cordset is damaged and you have to change it, do not do the job yourselves! Take
the product to an after sales authorised repair centre or to a person with similar skill and
knowledge, in order to avoid any risk of danger.
•
The appliance must be positioned so that the plug is always accessible.
•
Do not mount the product on walls made of synthetic material.
• The VPS Design Heaters are only approved for Wallmounting
• Additional you need a extern thermostat (for example the TPF-Eco)
Warning! this device has to be grounded
This device may only be operated using alternating current and the operating voltage indicated on
the power rating plate
•
Nominal Voltage 230V AC, 50 Hz

Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
2.1 User Manuel VPS Design RF Model
2.1.1 Setting the Room Thermostat
Press the
receiver button for more than 3 seconds, until the indicator light begins to flash. Subsequent
-
ly press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indi
-
cator light stops flashing the two products are assigned.
2.1.2 Setting the sender
Press the receiver button for at least 3 seconds until the indicator light starts flashing.
Two modes of operation are possible.
Slow flashing:
On\Off switch
Fast flashing:
instigator
To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see
user manual transmitter). Check that the indicator light is no longer flashing.
Application Example
The use of a room thermostat in combination with a opening detector is ideal, because the opening de
-
tector will detect if a window is open and will automatically switch to frost protection. By pressing the
receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting
is changed as soon as the signal light stops flashing.
2.1.3 Deleting Allocations
To delete the setting simply press the receiver key for approximately 30 seconds until you see the recei
-
ver light flash briefly. All transmitters are now deleted.
2.1.4 Receiver RF- Technical Specifications
•
Power Supply 230 V, 50 Hz +/-10%
•
Protection Class II
•
Expenditure : 0,5 VA
•
Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control
•
Radio Frequency 868 MHz (NormEN 300 220),
•
Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the construction of
the building and the electromagnetic interference
•
Maximal Number of receivers: 8
•
Mode of operation: type 1.C (Micro-disconnection)
•
Operating Temperature: -5°C to +50°C
•
Storage Temperature: -10 °C +70°C
•
Dimensions: 120 x 54 x 25 mm
•
Degree of Protection : IP 44 - IK 04
•
To be installed in average polluted Areas

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove all
protective coverage before turning on the device. When using the device for the first time you
might detect a strong odor. This is no reason for concern; it is caused by residues of production
and will disappear shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other
heating device as well. Only a qualified electrician may open or remove the device from the power
supply.
3. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
3.1 Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this ma
-
nual to any other succeeding owner of the device. The device comes with a power plug that has to be
plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
4.1 Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials
can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible fire hazard the safety distances are observed during assembly:
Side walls of the heater to any masonry:
5 cm
Side walls of the heater to combustible materials: 10 cm
Distance radiator to the floor:
25 cm
arranged spaced upper radiator limit to about components or covers (. Eg window):
flammable 15 cm
nonflammable 10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance
when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore
there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof
slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a
shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration
on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw
the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and
the wall.
Hang the device in the two or three fittings and tighten it down. See also the additional mounting infor
-
mation at the following pages!

Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
4.2 Wall Mounting
Type
Power
[Watt]
With
A
High
B
Deep
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
I
Weight
[kg]
VPS Design
1000 RF
1000
755
454
68
442
140
375
250
115
375
15,0
VPS Design
1200 RF
1200
755
454
68
442
140
375
250
115
375
15,0
VPS Design
1500 RF
1500
1055
454
68
740
140
375
250
115
525
20,0
VPS Design
2000 RF
2000
1055
454
68
740
140
375
250
115
525
20,0
VPS Design H
1200
1200
454
1055
68
210
87
984
250
100
223
17,0

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
4.3 Additional wall mounting information
1. Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall
2. Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed
“automatically”.
Topside of heater
Wallmount:
fixing with 3 screw!
mount locked!
Underside detailview
Press a screwdriver
into the groove to
unlock the mount.
mount is unlocked
switch of the Heater from the
Wallmounting
1. Press the screwdriver into the
groove.
2. Remove the Heater from the
Wall
Wall

Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
5. Installation of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC)
50 Hz. The electrical installation may only be performed according to the user manual and only by a
qualified Electrician. The device was designed to be used with termination and the connection cable
has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connection line may
not touch the device at any time.

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
8. Regulation
From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the
Ecodesign requirements 2015/1188.
The installation and commissioning of the devices is only permitted in conjunction with external room
temperature controllers that fulfill the following functions:
• electronic room temperature control
and has at least one of the following properties:
•
room temperature control, with presence detection
•
room temperature control, with open window detection
•
with distance control option
•
with adaptive start control
The following room temperature controller systems
•
RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface
(Art.Nr.750 000 640) or
from Technotherm meet the following requirements and therefore the ErP Directive:
•
electronic room temperature control plus week timer
•
room temperature control, with open window detection (optional)
•
with distance control option
Installation of the receiver and the interfaces see separate instructions. For customer service - see last
page.
Failure to comply with these requirements will result in the loss of the CE mark.

Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
Type: VPS Design RF (additional TPF Thermostat and Eco-Interface otionally necessary)
Item
Symbol
Value
Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
05
1,0
1,5
2,0
kW
manual heat charge control, with integrated thermostat
NO
Minimum heat
output (indicative)
P
min
0,5
1,0
1,5
2,0
kW
manual heat charge control with room and/or outdoor tempera
-
ture feedback
NO
Maximum conti
-
nuous heat output
P
max,c
0,5
1,0
1,5
12,0
kW
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumption
fan assisted heat output
NO
At nominal heat
output
el
max
0,5
1,0
1,5
2,0
kW
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
<0,5
<0,5
<0,5
<0,5
kW
single stage heat output and no room temperature control
NO
In standby mode
el
SB
<0,5
<0,5
<0,5
<0,5
kW
Two or more manual stages, no room temperature control
NO
with mechanic thermostat room temperature control
NO
with electronic room temperature control
NO
electronic room temperature control plus day timer
NO
electronic room temperature control plus week timer
YES
Other control options (multiple selections possible)
room temperature control, with presence detection
NO
room temperature control, with open window detection
YES
with distance control option
YES
with adaptive start control
NO
with working time limitation
NO
with black bulb sensor
NO

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB

Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB

Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
Technotherm is a label from Lucht LHZ GmbH & Co. KG
Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany
Phone: +49 3724 66869 0
Telefax: +49 3724 66869 20
info@technotherm.de | www.technotherm.de
Technical alternations, errors, omissions and errata reserved. Dimensions
are stated without warranty!
Updated: April 18
TECHNOTHERM After-sales service:
Ph. +49 (0) 911 937 83 210