background image

 Feel good through warmth from electricity - www.technotherm.de

Types:

•  VPS- Design B 1000 - 2000 RF

•  VPS- Design W 1000 - 2000 RF

•  VPS- Design B/W 1200 H RF

 

Installation and Operating Instructions

     VPS Design 

 

Please read attentively and keep in a safe place!  

Subject to alterations! 

Id_no.  911 361 911

Issue 04/18

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

1. For your safety

•  This appliance is intended for normal household use and not for use for vehicles or on board 

ships or aircrafts.

•  This appliance can be used by children aged from 8 years and above and persons with re-

duced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children without supervision.

• 

Children of less than 3 years should be kept away unless continuously supervised.

• 

Children aged from 3 years and less than 8 years shall only switch on/off the appliance pro

-

vided that it has been placed or installed in its intended normal operating position and they 

have been given supervision or instruction concerning use of the appliance in a safe way and 

understand the hazards involved. Children aged from 3 years and less than 8 years shall not 

plug in, regulate and clean the appliance or perform user maintenance.

•  CAUTION — Some parts of this product can become very hot and cause burns. Particular 

attention has to be given where children and vulnerable people are present.

• 

Make sure that your supply rating corresponds to what specified on the rating plate: 230V~, 

50Hz.

• 

During function, place the heater in a safe position:

 

- at least 1m far from inflammable objects or furnitures;

 

- leaving not less than 1m of free space in front of the heater;

 

- not located immediately below a socket-outlet.

• 

Do not leave animals or children touch or play with the appliance.

• 

Do not use the heater in rooms with explosive gas or while using inflammable solvents or 

varnish or glues.

• 

If the cordset is damaged and you have to change it, do not do the job yourselves! Take 

the product to an after sales authorised repair centre or to a person with similar skill and 

knowledge, in order to avoid any risk of danger.

• 

The appliance must be positioned so that the plug is always accessible.

• 

Do not mount the product on walls made of synthetic material.

•  The VPS Design Heaters are only approved for Wallmounting

•  Additional you need a extern thermostat (for example the TPF-Eco)

Warning! this device has to be grounded

This device may only be operated using alternating current and the operating voltage indicated on 

the power rating plate

• 

Nominal Voltage            230V AC, 50 Hz

 


background image

Installation and Operating Instructions

 

VPS Design

Feel good through warmth from electricity - www.technotherm.de 

GB

2.1 User Manuel VPS Design RF Model
2.1.1 Setting the Room Thermostat

Press the 

receiver button for more than 3 seconds, until the indicator light begins to flash. Subsequent

-

ly press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indi

-

cator light stops flashing the two products are assigned.

2.1.2 Setting the sender

Press the receiver button for at least 3 seconds until the indicator light starts flashing.

 

Two modes of operation are possible.

Slow flashing:    

On\Off switch

 

Fast flashing:    

instigator

To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see 

user manual transmitter). Check that the indicator light is no longer flashing.

Application Example

The use of a room thermostat in combination with a opening detector is ideal, because the opening de

-

tector will detect if a window is open and will automatically switch to frost protection. By pressing the 

receiver button for approximately 10 seconds, you can change the relay´s setting. You know the setting 

is changed as soon as the signal light stops flashing. 

2.1.3 Deleting Allocations

To delete the setting simply press the receiver key for approximately 30 seconds until you see the recei

-

ver light flash briefly. All transmitters are now deleted.

2.1.4 Receiver RF- Technical Specifications

• 

Power Supply 230 V, 50 Hz +/-10%

• 

Protection Class II

• 

Expenditure : 0,5 VA

• 

Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control

• 

Radio Frequency 868 MHz (NormEN 300 220),

• 

Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the construction of 

the building and the electromagnetic interference

• 

Maximal Number of receivers: 8

• 

Mode of operation: type 1.C (Micro-disconnection)

• 

Operating Temperature: -5°C to +50°C

• 

Storage Temperature: -10 °C +70°C

• 

Dimensions: 120 x 54 x 25 mm

• 

Degree of Protection : IP 44 - IK 04

• 

To be installed in average polluted Areas

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

WARNING

Do not install this device in areas that present an explosion hazard like a garage. Remove all 

protective coverage before turning on the device. When using the device for the first time you 

might detect a strong odor. This is no reason for concern; it is caused by residues of production 

and will disappear shortly.

The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other 

heating device as well. Only a qualified electrician may open or remove the device from the power 

supply.

3. Maintenance

Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.

3.1 Assembly instruction

This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this ma

-

nual to any other succeeding owner of the device. The device comes with a power plug that has to be 

plugged into an outlet.

The device is designed to be connected to 230V (nominal) alternating current (AC).

4.1 Wall Installation

When installing the device, the safety distance must be strictly adhered to, so that flammable materials 

can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.

• Due to possible fire hazard the safety distances are observed during assembly:

Side walls of the heater to any masonry: 

 

 5 cm

Side walls of the heater to combustible materials:   10 cm

Distance radiator to the floor:  

 

 

25 cm

arranged spaced upper radiator limit to about components or covers (. Eg window):

  

 

 

 

 

flammable   15 cm

  

 

 

 

 

nonflammable 10 cm

To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance 

when installing the device. Mount the device to a wall that is fireproof up to 90 °C.

The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore 

there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof 

slopes and ceilings.

If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a 

shower or a bath.

When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration 

on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw 

the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and 

the wall.

Hang the device in the two or three fittings and tighten it down. See also the additional mounting infor

-

mation at the following pages!

 


background image

Installation and Operating Instructions

 

VPS Design

Feel good through warmth from electricity - www.technotherm.de 

GB

4.2 Wall Mounting

Type

Power

[Watt]

With

A

High

B

Deep

C

[mm]

D

[mm]

E

[mm]

F

[mm]

G

[mm]

H

[mm]

I

Weight

[kg]

VPS Design 

1000 RF

1000

755

454

68

442

140

375

250

115

375

15,0

VPS Design 

1200 RF

1200

755

454

68

442

140

375

250

115

375

15,0

VPS Design 

1500 RF

1500

1055

454

68

740

140

375

250

115

525

20,0

VPS Design 

2000 RF

2000

1055

454

68

740

140

375

250

115

525

20,0

VPS Design H 

1200

1200

454

1055

68

210

87

984

250

100

223

17,0

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

4.3 Additional wall mounting information

1. Drill three holes of 7mm and fix the wall bracket. Screw in the three 4 x 25 mm screws into the wall 

2. Click the heater first at the top into the wall bracket and then at the bottom. The heater will be fixed 

“automatically”.

Topside of heater

Wallmount:

fixing with 3 screw!

mount locked!

Underside detailview

Press a screwdriver 

into the groove to 

unlock the mount.

mount is unlocked

switch  of  the  Heater  from  the 

Wallmounting

1. Press the screwdriver into the 

groove.

2.  Remove  the  Heater  from  the 

Wall

Wall

 


background image

Installation and Operating Instructions

 

VPS Design

Feel good through warmth from electricity - www.technotherm.de 

GB

5. Installation of Electricity

The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC) 

50 Hz. The electrical installation may only be performed according to the user manual and only by a 

qualified Electrician. The device was designed to be used with termination and the connection cable 

has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)

The distance between the receptacle and the device hast to be at least 10cm. The connection line may 

not touch the device at any time.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

8. Regulation

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of the 

Ecodesign requirements 2015/1188.

 

The installation and commissioning of the devices is only permitted in conjunction with external room 

temperature controllers that fulfill the following functions:

 

•  electronic room temperature control

 

and has at least one of the following properties:

 

• 

room temperature control, with presence detection

• 

room temperature control, with open window detection

• 

with distance control option

• 

with adaptive start control

The following room temperature controller systems

• 

RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface 

(Art.Nr.750 000 640) or

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

• 

electronic room temperature control plus week timer 

• 

room temperature control, with open window detection (optional)

• 

with distance control option 

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page.

 

Failure to comply with these requirements will result in the loss of the CE mark.

 


background image

Installation and Operating Instructions

 

VPS Design

Feel good through warmth from electricity - www.technotherm.de 

GB

Type: VPS Design RF (additional TPF Thermostat and Eco-Interface otionally necessary)

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat 

output

P

nom

05

1,0

1,5

2,0

kW

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

0,5

1,0

1,5

2,0

kW

manual heat charge control with room and/or outdoor tempera

-

ture feedback

NO

Maximum conti

-

nuous heat output

P

max,c

0,5

1,0

1,5

12,0

kW

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electricity 

consumption

fan assisted heat output

NO

At nominal heat

output

el

max

0,5

1,0

1,5

2,0

kW

Type of heat output/room temperature control (select

one)

At minimum heat 

output

el

min

<0,5

<0,5

<0,5

<0,5

kW

single stage heat output and no room temperature control

NO

In standby mode

el

SB

<0,5

<0,5

<0,5

<0,5

kW

Two or more manual stages, no room temperature control

NO

with mechanic thermostat room temperature control

NO

with electronic room temperature control

NO

electronic room temperature control plus day timer

NO

electronic room temperature control plus week timer

YES

Other control options (multiple selections possible)

room temperature control, with presence detection

NO

room temperature control, with open window detection

YES

with distance control option

YES

with adaptive start control

NO

with working time limitation

NO

with black bulb sensor

NO

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

 


background image

Installation and Operating Instructions

 

VPS Design

Feel good through warmth from electricity - www.technotherm.de 

GB

 


background image

Feel good through warmth from electricity - www.technotherm.de

Installation and Operating Instructions

 

VPS Design 

Feel good through warmth from electricity - www.technotherm.de 

GB 

Technotherm is a label from Lucht LHZ GmbH & Co. KG

Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany

Phone:  +49 3724 66869 0

Telefax:   +49 3724 66869 20

info@technotherm.de | www.technotherm.de

Technical alternations, errors, omissions and errata reserved. Dimensions

are stated without warranty! 

Updated: April 18

TECHNOTHERM After-sales service:

Ph. +49 (0) 911 937 83 210