PDF User Manual

  1. Home
  2. Manuals
  3. Technotherm VPS 1000 Installation And Technical Manual

Technotherm VPS 1000 Installation And Technical Manual

VPS 1500\ VPS 1200\ VPS DSM 1000\ VPS 2000\ VPS DSM 1500\ VPS DSM 2000\ VPS DSM 1200\ VPS RF 1000\ VPS RF 1200\ VPSRF1500\ VP 1000\ VPS RF 2000\ VP 1500\ VP 1200\ VP 2000\ VPS H 1200

Made by: Technotherm
Type: Installation And Technical Manual
Category: Heater
Pages: 10
Size: 0.92 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

D

 

THESE INSTRUCTIONS SHOULD BE READ

 

CAREFULLY AND RETAINED FOR FUTURE

 

REFERENCE. BE SURE TO OBSERVE ALL

 

LABELS AND WARNINGS ON THE APPLIANCE

 

Edition: 12/17 

Id_Nr. 911 360 870 

Installation and

 

technical manual

 

VP / VPS / VPS H / VPS DSM / VPS RF with feet´s 

GB

 

Eco-Design Directive 2015/1188: 

Feet using: 

This product is only suitable for well-

insulated rooms or for occasional use 

 


background image

 

 

2  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

GB

 

 

1. For your safety 

  This appliance is intended for normal household 

use and not for use for vehicles or on board 

ships or aircrafts. 

  This appliance can be used by children aged 

from 8 years and above and persons with 

reduced physical, sensory or mental capabilities 

or lack of experience and knowledge if they 

have been given supervision or instruction 

concerning use of the appliance in a safe way 

and understand the hazards involved. Children 

shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children 

without supervision. 

  Children of less than 3 years should be kept 

away unless continuously supervised. 

  Children aged from 3 years and less than 8 

years shall only switch on/off the appliance 

provided that it has been placed or installed in 

its intended normal operating position and they 

have been given supervision or instruction 

concerning use of the appliance in a safe way 

and understand the hazards involved. Children 

aged from 3 years and less than 8 years shall 

not plug in, regulate and clean the appliance or 

perform user maintenance. 

 

 

 


background image

 

 

3  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

GB

 

 

CAUTION — Some parts of this product can 

become very hot and cause burns. Particular 

attention has to be given where children and 

vulnerable people are present. 

  Make sure that your supply rating corresponds 

to what specified on the rating plate: 230V~, 

50Hz. 

  During function, place the heater in a safe 

position: 

- at least 1m far from inflammable objects or 

furnitures; 

- leaving not less than 1m of free space in 

front of the heater; 

- not located immediately below a socket-

outlet. 

  Do not leave animals or children touch or play 

with the appliance. 

  Do not use the heater in rooms with explosive 

gas or while using inflammable solvents or 

varnish or glues. 

  If the cordset is damaged and you have to 

change it, do not do the job yourselves! Take the 

product to an after sales authorised repair centre 

or to a person with similar skill and knowledge, 

in order to avoid any risk of danger. 

  The appliance must be positioned so that the 

plug is always accessible. 

  Do not mount the product on walls made of 

synthetic material.

 

 


background image

 

 

4  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

 

 

 

 

Warning! this device has to be grounded 

 

This device may only be operated using alternating current and the operating voltage indicated 

on the power rating plate 

 

 

Nominal Voltage            230V AC, 50 Hz

 

 

Protection Class            I 

 

Degree of Protection     IP 24 

 

Room Thermostat         7°C till 30°C 

 

2.1 User Manual for the VPS / VPS H / VP 

 

 

 

 

The console is segmented into the following parts 

 

(+ )

    key 

(   )

    key 

Mode

 selector key 

          On\ Off switch 

 
 

 

2.1 Selectror key: 

 

The Selector Key has 4 basic Functions: 

“Comfort,” “Setback”, “Frost Protection”, and “Off”

 

 

      

Comfort Mode:

 The heater is in continuous operation.  To change the set temperature press the  + or  

- key

 

 

        Setback Mode:

   Here you can make adjustments for night -time operating 

 

        Frost Protection:  

The heater is working in Frost Protection Array (7°C)  

 

 

OFF:

 The two parallel lines in the display indicate that the heater is still running.

 

 

2.2 Normal Operation: 

To turn the heating device on, press the On\Off key and select between the Comfort and Setback mode. 

You can switch between the different modes by pressing the selector key until the desired token appears 

on the display. In addition the digital visual display will show the amount of electricity used and the room 

temperature. By pressing the + or  –  key, you can adjust the different settings. The display will flash 

approximately 4 times in two intervals. If the current room temperature is different to the desired room 

temperature you can make adjustments by pressing the   + or – key. Almost instantly you will feel the warm 

air coming out of the heater .The + or- keys allow you to set the heater to your desired defaults at any time. 

  

GB 

 


background image

 

 

5  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

Note: On your display you will also see a clock.    . However this function is unavailable and can 

therefore be ignored.

 

 

 

2.3 User Manuel for the VPS DSM 

Please see additional manual at 

http://www.lucht-lhz.de/lhz-app-gb.html

 and download the manual 

 

 

3.1 User Manuel VPS RF Model 

 

3.1.1 Setting the Room Thermostat

 

Press the 

receiver

 

button

 for more than 3 seconds, until the indicator light begins to flash. Subsequently 

press the transmitter key in the configuration mode. (see User Manual Receiver) As soon as the indicator 

light stops flashing the two products are assigned. 

 

 

3.1.2 Setting the sender 

 

Press the receiver button for at least 3 seconds until the indicator light starts flashing. 

Two modes of operation are possible. 

Slow flashing: 

  

On\Off switch 

Fast flashing:

   

instigator 

To switch the mode again, press the key briefly. Take the transmitter into the Configuration mode (see 

user manual transmitter). Check that the indicator light is no longer flashing. 

 

Application Example 

The use of a room thermostat in combination with a opening detector is ideal, because the opening detector 

will detect if a window is open and will automatically switch to frost protection. By pressing the receiver 

button for approximately 10 seconds, you can change the relay´s setting. You know the setting is changed 

as soon as the signal light stops flashing. 

 

3.1.3 Deleting Allocations 

To delete the setting simply press the receiver key for approximately 30 seconds until you see the 

receiver light flash briefly. All transmitters are now deleted. 

 

 

3.1.4 Receiver RF- Technical Specifications 

 

 

Power Supply 230 V, 50 Hz +/-10% 

 

Protection Class II 

 

Expenditure : 0,5 VA 

 

Switching capacity max.: 16 A 230 Veff Cos j =1 or max. 300 W with lighting control 

 

Radio Frequency 868 MHz (NormEN 300 220), 

 

Radio Range up to 300 m in an open field, indoors up to ca. 30m, depending on the  

construction of the building and the electromagnetic interference 

 

Maximal Number of receivers: 8 

GB 

GB 

GB 

 


background image

 

 

6  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

 

Mode of operation: type 1.C (Micro-disconnection) 

 

Operating Temperature: -5°C to +50°C 

 

Storage Temperature: -10 °C +70°C 

 

Dimensions: 120 x 54 x 25 mm 

 

Degree of Protection : IP 44 - IK 04 

 

To be installed in average polluted Areas 

 

 

WARNING 

Do not install this device in areas that present an explosion hazard like a garage. Remove 

all protective coverage before turning on the device. When using the device for the first time 

you might detect a strong odor. This is no reason for concern; it is caused by residues of 

production and will disappear shortly. 

The rising heat may cause stains on the ceiling, however this phenomena can be caused by 

any other heating device as well. Only a qualified electrician may open or remove the device from the power 

supply. 

 

 

4. Maintenance 

 

Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent. 

 

5. Assembly instruction 

This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual 

to any other succeeding owner of the device. The device comes with a power plug that has to be plugged 

into an outlet. 

The device is designed to be connected to 230V (nominal) alternating current (AC). 

5.2 Assembling the Feed 

 

Do not put the device near any inflammable items. 

1. Put the convector on a table or any other work surface. 

2. Align the holes you find on the bottom of the convector to the  

 holes implemented on the feet. 

3. Attach the feet to the device using the screws in your accessories kid. 

Attention: The model VPS H 1200 is only used by wall mounting! 

 

 

5.3 

Installation of Electricity 

 

The device was developed for an electrical voltage of 230 V(nominal) and an alternating current of (AC) 

50 Hz. 

The electrical installation may only be performed according to the user manual and only by 

a qualified Electrician.

 The device was designed to be used with termination and the connection cable 

has to be plugged into an appropriate socket at all times. (Notice Permanent cables may not be used)The 

distance between the receptacle and the device hast to be at least 10cm. The connection line may not 

touch the device at any time  

 

 


background image

 

 

7  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

 

 

 

 

 

 

 

 

 

 

Technical data´s 

 

 

 

 

 

 

Model 

 

Power 

[Watt] 

With 

High 

Deep 

[mm] 

[mm] 

[mm] 

[mm] 

[mm} 

[mm] 

Weight 

[kg] 

VPS 1000 

1000 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS 1200 

1200 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS 1500 

1500 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VPS 2000 

2000 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VPS DSM 

1000 

1000 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS DSM 

1200 

1200 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS DSM 

1500 

1500 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VPS DSM 

2000 

2000 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VPS RF 

1000 

1000 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS RF 

1200 

1200 

750 

450 

85 

442 

140 

375 

250 

115 

375 

11.5 

VPS 

RF1500 

1500 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VPS RF 

2000 

2000 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

15.0 

VP 1000 

1000 

750 

450 

85 

442 

140 

375 

250 

115 

375 

8.2 

VP 1200 

1200 

750 

450 

85 

442 

140 

375 

250 

115 

375 

8.2 

VP 1500 

1500 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

10.3 

VP 2000 

2000 

1050 

450 

85 

740 

140 

375 

250 

115 

525 

10.3 

VPS H 1200 

1200 

450 

1054 

85 

210 

87 

984 

250 

100 

223 

15,0 

 

 


background image

 

 

8  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

 

6. Regulation 

 

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of 

the Ecodesign requirements 2015/1188. 

The installation and commissioning of the devices is only permitted in conjunction with external 

room temperature controllers that fulfill the following functions: 

 

  electronic room temperature control 

 

and has at least one of the following properties: 

 

  room temperature control, with presence detection 

  room temperature control, with open window detection 

  with distance control option 

  with adaptive start control 

  with working time limitation 

  with black bulb sensor 

 

The following room temperature controller systems 

 

  RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-

Interface (Art.Nr.750 000 640) or 

  DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101) 

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

 

  electronic room temperature control plus week timer (RF/DSM) 

  room temperature control, with open window detection (DSM) 

  with distance control option (DSM) 

  with adaptive start control (DSM) 

 

Use of the VPS / VP Standard range (without external thermostat control) is only permitted on feet. 

 

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page. 

 

Failure to comply with these requirements will result in the loss of the CE mark. 

 

 

 

 


background image

 

 

9  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

Model: VPS DSM  (additional DSM interface necessary) 

Item 

Symbol 

Value 

 

 

 

 

 

 

 

Value 

 

Item

 

Value 

Heat output 

Type of heat input, for electric storage local space heaters only (select one) 

Nominal heat 

output 

Pnom

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control, with integrated thermostat 

No 

Minimum heat 

output 

(indicative) 

Pmin

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control with room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous heat 

output 

Pmax,c

 

1000 

1200 

1500 

2000 

Watt 

 

electronic heat charge control with room and/or outdoor 
temperature feedback 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

fan assisted heat output 

No 

At nominal heat 

output 

elmax

 

1000 

1200 

1500 

2000 

Watt 

 

Type of heat output/room temperature control (select 
one) 

At minimum heat 

output 

elmin

 

0,87 

0,87 

0,87 

0,87 

Watt 

 

single stage heat output and no room temperature control 

No 

In standby mode 

elSB

 

0,87 

0,87 

0,87 

0,87 

Watt 

 

Two or more manual stages, no room temperature control 

No 

 

 

 

 

 

 

 

 

with mechanic thermostat room temperature control 

No 

 

 

 

 

 

 

 

 

with electronic room temperature control 

No 

 

 

 

 

 

 

 

 

electronic room temperature control plus day timer 

No 

 

 

 

 

 

 

 

 

electronic room temperature control plus week timer 

Yes 

 

 

 

 

 

 

 

 

Other control options (multiple selections possible) 

 

 

 

 

 

 

 

 

room temperature control, with presence detection 

No 

 

 

 

 

 

 

 

 

room temperature control, with open window detection 

Yes 

 

 

 

 

 

 

 

 

with distance control option 

Yes 

 

 

 

 

 

 

 

 

with adaptive start control 

Yes 

 

 

 

 

 

 

 

 

with working time limitation 

No 

 

 

 

 

 

 

 

 

with black bulb sensor 

No 

Model: VPS RF  (additional TPF Thermostat and Eco-Interface necessary) 

Item 

Symbol 

Value 

 

 

 

 

 

 

 

Value 

 

Item

 

Value 

Heat output 

Type of heat input, for electric storage local space heaters only (select one) 

Nominal heat 

output 

P

nom

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control, with integrated thermostat

 

No 

Minimum heat 

output 

(indicative) 

P

min

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control with room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous heat 

output 

P

max,c

 

1000 

1200 

1500 

2000 

Watt 

 

electronic heat charge control with room and/or outdoor 
temperature feedback

 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

fan assisted heat output

 

No 

At nominal heat 

output 

el

max

 

1000 

1200 

1500 

2000 

Watt 

 

Type of heat output/room temperature control (select 
one)

 

At minimum heat 

output 

el

min

 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

single stage heat output and no room temperature control

 

No 

In standby mode 

el

SB

 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

Two or more manual stages, no room temperature control

 

No 

 

 

 

 

 

 

 

 

with mechanic thermostat room temperature control

 

No 

 

 

 

 

 

 

 

 

with electronic room temperature control

 

No 

 

 

 

 

 

 

 

 

electronic room temperature control plus day timer

 

No 

 

 

 

 

 

 

 

 

electronic room temperature control plus week timer

 

Yes 

 

 

 

 

 

 

 

 

Other control options (multiple selections possible)

 

 

 

 

 

 

 

 

 

room temperature control, with presence detection

 

Nein 

 

 

 

 

 

 

 

 

room temperature control, with open window detection

 

No 

 

 

 

 

 

 

 

 

with distance control option

 

Yes 

 

 

 

 

 

 

 

 

with adaptive start control

 

No 

 

 

 

 

 

 

 

 

with working time limitation

 

nein 

 

 

 

 

 

 

 

 

with black bulb sensor

 

nein 

Contact details: 

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

10  

 

Edition: 12/17

 

 

Manual 

VP / VPS / VPS H / VPS DSM / VPS RF

 

Model: VPS   (only use with feet´s – no wall mounting allowed) 

Item 

Symbol 

Value 

 

 

 

 

 

 

 

Value 

 

Item

 

Value 

Heat output 

Type of heat input, for electric storage local space heaters only (select one) 

Nominal heat 

output 

Pnom

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control, with integrated thermostat 

No 

Minimum heat 

output 

(indicative) 

Pmin

 

1000 

1200 

1500 

2000 

Watt 

 

manual heat charge control with room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous heat 

output 

Pmax,c

 

1000 

1200 

1500 

2000 

Watt 

 

electronic heat charge control with room and/or outdoor 
temperature feedback 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

fan assisted heat output 

No 

At nominal heat 

output 

elmax

 

1000 

1200 

1500 

2000 

Watt 

 

Type of heat output/room temperature control (select 
one) 

At minimum heat 

output 

elmin

 

 

 

 

 

Watt 

 

single stage heat output and no room temperature control 

No 

In standby mode 

elSB

 

 

 

 

 

Watt 

 

Two or more manual stages, no room temperature control 

No 

 

 

 

 

 

 

 

 

with mechanic thermostat room temperature control 

No 

 

 

 

 

 

 

 

 

with electronic room temperature control 

yes 

 

 

 

 

 

 

 

 

electronic room temperature control plus day timer 

No 

 

 

 

 

 

 

 

 

electronic room temperature control plus week timer 

No 

 

 

 

 

 

 

 

 

Other control options (multiple selections possible) 

 

 

 

 

 

 

 

 

room temperature control, with presence detection 

No 

 

 

 

 

 

 

 

 

room temperature control, with open window detection 

No 

 

 

 

 

 

 

 

 

with distance control option 

No 

 

 

 

 

 

 

 

 

with adaptive start control 

No 

 

 

 

 

 

 

 

 

with working time limitation 

No 

 

 

 

 

 

 

 

 

with black bulb sensor 

No 

Contact details 

Lucht LHZ Elektroheizung GmbH & Co. KG Reinhard-Schmidt-Str. 1 D 09217 Burgstädt 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lucht LHZ Elektroheizung GmbH & Co. KG

 

Reinhard-Schmidt-Str. 1

 

D 09217 Burgstädt

 

Fon: +49 (0) 3724 66869 0

 

Fax: +49 (0) 3724 66869 20

 

E-mail: 

info@technotherm.de

  

web: www.technotherm.de

 

GB