PDF User Manual

  1. Home
  2. Manuals
  3. Technotherm TT-KS 500 S Installation And Technical Manual

Technotherm TT-KS 500 S Installation And Technical Manual

TT-KS 1000 S\ TT-KS 1200 S\ TT-KS 1500 S\ TT-KS 2000 S\ TT-KS 1800 S\ TT-KS 2400 S\ TT-KS 700 S LT*\ TT-KS 2800 S\ TT-KS 1200 S LT*\ TT-KS 1500 S LT*\ TT-KS 1800 S LT*\ TT-KS 500 S X4\ TT-KS 1000 S X4\ TT-KS 1200 S X4\ TT-KS 1500 S X4\ TT-KS 1200 N\ TT-KS 800 N\ TT-KS 1600 N\ TT-KS 800 N X4\ TT-KS 2000 N\ TT-KS 1200 N X4\ TT-KS 1200 H\ TT-KS 2200 H\ TT-KS 1800 H\ HR 1200 deluxe\ TT-KS 1200 H X4\ HR 1200 KSB

Made by: Technotherm
Type: Installation And Technical Manual
Category: Heater
Pages: 12
Size: 0.94 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

TT-KS  S 

TT-KS  N 

TT-KS  H 

 

 

 

 

 

 

 

 

 

 Installation and

 

technical manual

 

Electric Combination Heaters TT-KS  mobile /castors 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

GB

 

2

 

 

3

 

THESE INSTRUCTIONS SHOULD BE READ

 

CAREFULLY AND RETAINED FOR FUTURE

 

REFERENCE. 

BE SURE TO OBSERVE ALL

 

LABELS AND WARNINGS ON THE APPLIANCE

.

 

 

Edition:12/17 

Id_Nr. 911 360 950 

Eco-Design Directive 2015/1188: 

Feet using: 

This product is only suitable for well-

insulated rooms or for occasional use 

 


background image

 

 

2  

 

 

 

 

 

Manual TT-KS 

GB

 

 

1. For your safety 

  This appliance is intended for normal household 

use and not for use for vehicles or on board 

ships or aircrafts. 

  This appliance can be used by children aged 

from 8 years and above and persons with 

reduced physical, sensory or mental capabilities 

or lack of experience and knowledge if they 

have been given supervision or instruction 

concerning use of the appliance in a safe way 

and understand the hazards involved. Children 

shall not play with the appliance. Cleaning and 

user maintenance shall not be made by children 

without supervision. 

  Children of less than 3 years should be kept 

away unless continuously supervised. 

  Children aged from 3 years and less than 8 

years shall only switch on/off the appliance 

provided that it has been placed or installed in 

its intended normal operating position and they 

have been given supervision or instruction 

concerning use of the appliance in a safe way 

and understand the hazards involved. Children 

aged from 3 years and less than 8 years shall 

not plug in, regulate and clean the appliance or 

perform user maintenance. 

 

 


background image

 

 

3  

 

 

 

 

 

Manual TT-KS 

GB

 

 

CAUTION — Some parts of this product can 

become very hot and cause burns. Particular 

attention has to be given where children and 

vulnerable people are present. 

  Make sure that your supply rating corresponds 

to what specified on the rating plate: 230V~, 

50Hz. 

  During function, place the heater in a safe 

position: 

- at least 1m far from inflammable objects or 

furnitures; 

- leaving not less than 1m of free space in 

front of the heater; 

- not located immediately below a socket-

outlet. 

  Do not leave animals or children touch or play 

with the appliance. 

  Do not use the heater in rooms with explosive 

gas or while using inflammable solvents or 

varnish or glues. 

  If the cordset is damaged and you have to 

change it, do not do the job yourselves! Take the 

product to an after sales authorised repair centre 

or to a person with similar skill and knowledge, 

in order to avoid any risk of danger. 

  The appliance must be positioned so that the 

plug is always accessible. 

• Do not mount the product on walls made of 

synthetic material.

 

 

 


background image

 

 

4  

 

 

 

 

 

Manual TT-KS 

GB

 

Electrical Connections: 

 

The wires in the mains leads are colored in accordance with the following code:

 

 

GREEN & YELLOW:

 

EARTH

 

 

BLUE:

 

NEUTRAL

 

 

BROWN:

 

LIVE

 

 

WARNING – THIS APPLIANCE MUST BE EARTHED

 

The installation of this appliance should be carried out by  a  competent electrician in

 

accordance with I.E.E. Regulations for Electrical Equipment.

 

The radiator is fitted with a standard UK 3 pin plug or EURO plug that can be directly connected 

to  an

 

electrical socket.  Care  must  be  taken  when  connecting  radiators  in  this  way  not

 

to 

overload the ring main circuit. If you are unsure contact a qualified

 

electrician.

 

Alternatively the mains cable can be cut to length and connected to a suitable fused 20

 

amp 

double-pole switched spur adjacent to the radiator. Please ensure that the

 

electricity supply is 

disconnected prior to using this installation method.

 

Each supply circuit to the radiator must incorporate a Fused 20 Amp double pole

 

switched 

spur having a contact separation of at least 3mm.

 

 

1.2 Handling 

 

This radiator is very heavy. Take adequate precautions when lifting and maneuvering it.

 

Always 

assess  the  load,  and  seek  assistance  with  heavy  or  awkward  loads  that  are

 

beyond  your 

capabilities.

 

 

1.3  

Positioning

 

 

This radiator is very heavy.  Please refer to Technical Data information contained within

 

this 

document. In order to fulfil the ErP-Guideline, you need to use castors. 

Wall mounting is not 

allowed.

 

 

It is important that the following instructions are strictly followed.

 

Keep the following minimum safety distances to avoid fire risk due to high surface

 

temperatures of the appliance during heating cycles:

 

Lateral heating walls – masonry  .................................................      50 mm 

Lateral heating walls – combustible matter ................................     100 mm

  

Cover plate – combustible covering installed on top of it ..........   150 mm

  

Cover plate – non-combustible covering installed on top of it ..   100 mm 

 

 

 

Please note that our IPX4 rated models should be used in bathrooms.

 

 

Portable radiators must not be fitted in bathrooms or wet areas.

 

 

CAUTION

 – This radiator must not be located below or in front of

 

a fixed socket outlet.

 

 

DO NOT POSITION

 under windows where curtains may contact the radiator.

 

 

DO NOT PLACE THE APPLIANCE

 in the vicinity of a swimming pool.

 

 

 

 

 


background image

 

 

5  

 

 

 

 

 

Manual TT-KS 

GB

 

 

CAUTION 

– If during any reassembly of the radiator, a part of the thermal insulation

 

shows damage or deterioration which may impair safety; it should be replaced with an

 

identical part.

 

 

CAUTION

 – In order to avoid overheating, do not cover the radiator.

 

 

DO NOT COVER OR OBSTRUCT

 the surfaces of the appliance.

 

 

DO NOT PLACE OBJECTS

 in contact with the radiator

 

 

2.0 

General Information 

 

TECHNOTHERM  Combination Electric radiators  have  been  designed  using  the  latest 

technology to

 

create an elegant solution for all hard to heat situations. They can be installed in 

almost

 

any location apart from the safety restrictions noted in this manual.

 

The range has been developed to provide a flexible solution for electric heating in

 

Domestic 

properties, Conservatories, Holiday homes, Offices and any other temporary

 

heating situation.

 

Our unique patented ’Magmatic’ heating tablets provide the heat source for your new

 

radiator. 

Whilst the radiator is classed as a 100% efficient Direct Acting appliance, the

 

heating tablets 

provide  partial  storage to  prolong  your  heating comfort  and  to reduce

 

running  costs. The 

radiator has a robust body which incorporates a spot welded high fin

 

surface area to ensure 

that there are no contraction noises during the heating cycle.

 

The high fin design boasts 6 

times the normal radiator surface area to provide a

 

balance of Convection and Radiant heat 

for your added comfort.

 

The radiators can be simply plugged in to a “standard” socket or “hard” wired to an

 

existing 

spur connection. 

 

For added versatility we can supply Conservatory radiators which are also ideal for use

 

below 

windows with low sills.

 

All our standard model sizes are supplied with 

a E4

 

manual room thermostat. In addition to 

the  above  we  also  supply  Radio  Frequency  controlled  radiators  which  provide  all  the 

benefits of the standard version however the control wiring is eliminated. These

 

models can 

be 

controlled by our digital transmitter TBF or TPF.

 

All TECHNOTHERM radiators are manufactured to the highest safety and quality Standards. 

Each

 

radiator is CE Marked and carries all the necessary European Approvals.  

Each radiator is

 

fully checked and tested prior to leaving the factory and as such is packed 

with full

 

Quality certification.

 

 

 

 

We hope you enjoy the comfort provided by this superior product and we look forward

 

to 

being of assistance to you in the future.

 

 

 

 

 


background image

 

 

6  

 

 

 

 

 

Manual TT-KS 

GB

 

 

3.0 Preparation 

 

1.

 

Before beginning, remove the radiator

 

and parts from the box and check

 

everything is 

present and correct 

Model 

Power 

[Watt] 

Dimensions 

[cm] 

 

Protection 

class 

 

TT-KS 500 S 

500 

  38 x 63 x 7 

 

IP 20 

TT-KS 1000 S 

1000 

  68 x 63 x 7 

 

IP 20 

TT-KS 1200 S 

1200 

  68 x 63 x 7 

 

IP 20 

TT-KS 1500 S 

1500 

  98 x 63 x 7 

 

IP 20 

TT-KS 1800 S 

1800 

  98 x 63 x 7 

 

IP 20 

TT-KS 2000 S 

2000 

128 x 63 x 7 

 

IP 20 

TT-KS 2400 S 

2400 

128 x 63 x 7 

 

IP 20 

TT-KS 2800 S 

2800 

158 x 63 x 7 

 

IP 20 

 

 

 

 

 

TT-KS   700 S LT* 

700 

  68 x 63 x 7 

 

IP 20 

ca.60°C ST  

TT-KS 1200 S LT* 

1200 

 98 x 63 x 7 

 

IP 20 

ca.60°C ST 

TT-KS 1500 S LT* 

1500 

128 x 63 x 7 

 

IP 20 

ca.60°C ST 

TT-KS 1800 S LT* 

1800 

158 x 63 x 7 

 

IP 20 

ca.60°C ST 

 

 

 

 

 

TT-KS 500 S X4 

500 

38 x 63 x 7 

 

IP 24 

TT-KS 1000 S X4 

1000 

68 x 63 x 7 

 

IP 24 

TT-KS 1200 S X4 

1200 

68 x 63 x 7 

 

IP 24 

TT-KS 1500 S X4 

1500 

98 x 63 x 7 

 

IP 24 

 

 

 

 

 

TT-KS 800 N 

800 

  68 x 34 x 7 

 

IP 20 

TT-KS 1200 N 

1200 

   98 x 34 x 7 

 

IP 20 

TT-KS 1600 N 

1600 

128 x 34 x 7 

 

IP 20 

TT-KS 2000 N 

2000 

158 x 34 x 7 

 

IP 20 

 

 

 

 

 

TT-KS 800 N X4 

800 

  68 x 34 x 7 

 

IP 24 

TT-KS 1200 N X4 

1200 

  98 x 34 x 7 

 

IP 24 

 

 

 

 

 

TT-KS 1200 H 

1200 

   38 x 124 x 7 

 

IP 20 

TT-KS 1800 H 

1800 

   55 x 124 x 7 

 

IP 20 

TT-KS 2200 H 

2200 

   68 x 124 x 7 

 

IP 20 

 

 

 

 

 

TT-KS 1200 H X4 

1200 

   38 x 124 x 7 

 

IP 24 

HR 1200 KSB 

1200 

   38 x 124 x 7 

 

IP 24 

HR 1200 deluxe 

1200 

52 (64) x 102 x 8,5 (14)

*

 

 

IP 24 

ST = “surface temperature” - Surface temperature via the internal controller is set only by an electrical expert 

The top grille of the radiator can then be

 

fitted and secured with the securing

 

screws at each 

end.

 

At the bottom of the radiator, next to the

 

mains connection there is a small

 

temperature sensor. 

Loosen the gland and

 

pull the sensor down by 50 - 70 millimeters,

 

then re-tighten the gland. This 

enables the

 

radiator to gauge the room’s temperature

 

more accurately

 

 

 

3.2 

Electrical connection 

 

All  TECHNOTHERM TT-KS  radiators  come  with  a 

standard UK 3 pin plug that can be directly connected to

 

an electrical socket.

 

Alternatively the mains cable can be 

cut to length and connected to a suitable 

Fused 20 Amp 

double-pole  switched  spur  adjacent  to  the  radiator. 

Please ensure that the electricity supply is disconnected

 

prior to using this installation method. The mains plug

 

should be discarded safely and not re-used. 

 


background image

 

 

7  

 

 

 

 

 

Manual TT-KS 

GB

 

3.3 Radio frequency – wired versions model E4 

 
The regulation of the  desired 

room temperature implements a 

built-in  temperature control 

device. 

 

position 0 : OFF 

 
position 1 : approx. 5°C (frost             

protection) 

 

 

position 4 : approx. 20°C 

 

 
position 6 : approx  30°C 

 

 

An illuminated display indicates 

the heating process of the 

radiator. 

 

CAUTION 

- After completion of works all electrical connections should be

 

tested for tightness. 

Additionally an electrical safety check should be carried

 

out ie: short circuit, earth continuity, 

resistance to earth and polarity check

 

and all the relevant test certificates produced.

 

 

3.4 Radio frequency – RF models 

 

All  Radio  Frequency  radiators  come  complete  with  a  pre-wired TRF  Receiver which is 

controlled by  the TPF Eco control. 

 

TPF transmitter installation

 

a

 

Follow the instructions outlined on page 27 for single radiator installations according 

to the instructions included in the TPF transmitter packaging.

 

b

 

Locate the TPF programmer on a suitable wall in the same room as the   radiator.

  

 

 

CAUTION

 – After completion of works all electrical connections should be

 

tested for tightness. 

Additionally an electrical safety check should be carried

 

out ie: short circuit, earth continuity, 

resistance to earth and polarity check

 

and all the relevant test certificates produced. 

 

3.5 Installing castors and feet

 

All radiators are supplied with feet’s or castors however with the exception of

 

the Towel Rail. 

Consult the leaflet which

 

comes with them for fixing instructions. The official feet or castors

 

must be used.

 

 

 

 


background image

 

 

8  

 

 

 

 

 

Manual TT-KS 

GB

 

 

4.0 Operating safety 
 

This  appliance  complies  with the  European Standards  EN  60 335-1,  EN  60  335-2-61,  EN

 

61000-3-2,  EN  61000-3-3,  EN  55014  and  EN55104  for  Safety  &  Electromagnetic

 

Compatibility. These standards cover the requirement of the EMC Directives 89/336 &

 

73/23

 

 

RADIATOR POSITIONING

 -  A minimum clearance of 150mm to the front of the

 

radiator is 

essential for safety, however to enable the radiator to attain its maximum

 

performance ensure 

that any furniture or other obstruction is not placed closer than

 

250mm.

 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE

 

REFERENCE

 

 

CAUTION - THE SURFACE OF THIS RADIATOR CAN BE HOT.

 

The  surface  temperatures  of  this  radiator  are  within  the  requirements  of  EN60-335  the

 

European  Standard  covering  the  safety  requirements of electric heating appliances, and

 

momentary contact with any part of the radiator should not cause injury.

 

However, in order to be effective, radiators of any type do get hot, especially around

 

the air 

outlet grille.

 

 

Therefore, if aged or infirm persons, or young children, are likely to be left

 

unsupervised in 

the vicinity of a radiator precautions should be taken to ensure that

 

prolonged contact with 

the radiator cannot occur. We recommend that a guard is fitted

 

around the radiator, as is 

normal with some types of heating appliances in similar

 

circumstances.

 

CAUTION - IN ORDER TO AVOID OVERHEATING, DO NOT COVER THE SURFACES

 

OF 

THE RADIATOR AND DO NOT OBSTRUCT AIR OUTLET GRILLES

.  

Surfaces of the

 

radiator should not be covered or obstructed as this can cause excessive 

temperatures

 

that can be hazardous and may cause safety cut-outs to operate. For example, 

do not

 

put clothes, fabrics or any combustible materials on the radiator or allow curtains to

 

come within 75mm (3”) of the top and ends of the radiator. Do not allow furniture to

 

be pushed 

up against the radiator. A minimum clearance of 150mm is critical for safety,

 

however to 

ensure radiator performance is not affected a clearance of 250mm is

 

recommended.

 

 

DO NOT PLACE OBJECTS IN CONTACT WITH THE RADIATOR

 

 

CAUTION

 – The radiator must not be located below

 or of in front of 

a socket outlet.

 

PLEASE NOTE: THIS RADIATOR IS HEAVY 

 

 

 

 


background image

 

 

9  

 

 

 

 

 

Manual TT-KS 

GB

 

 

No attempt should be made to move the radiator without first seeking

 

specialist advice. If you 

are not happy that the radiator has been securely fixed, please

 

inform your installer.

 

 

DO NOT SIT OR STAND ON THE RADIATOR. 

 

DO NOT SPILL LIQUIDS ONTO THE APPLIANCE. IF YOU DO, SWITCH THE RADIATOR

 

OFF AND GET A QUALIFIED ELECTRICIAN TO CHECK IT.

 

 

 

DO NOT POKE OBJECTS THROUGH THE GRILLE.

 

 

 

DO NOT USE POLISHES ON THE RADIATOR OR ON FURNITURE NEAR TO IT.

  

 

 

The hot

 

interior of the radiator can produce paraffin smells from polish vapors which may last

 

for a number of hours.

 

In case of breakdown or other failure, switch off the radiator at both wall 

switches and

 

contact your supplier or the LHZ Help Desk on +49 (0) 3724 66869 0

 

Always 

ensure that the radiator is switched off and fuse is removed before

 

any repair is carried out.

 

 

IMPORTANT 

- Due to the newness of the materials the radiator will produce a slight

 

smell for 

the first few days of operation. 

 

ROOMS  MUST  BE  WELL  VENTILATED  AND  YOUNG  CHILDREN,  CAGED  BIRDS  OR

 

PERSONS  WITH  RESPIRATORY  COMPLAINTS  MUST  NOT  REMAIN  IN  CLOSE

 

PROXIMITY  TO  THE  RADIATOR  DURING  THE  FIRST  48  HOURS  OF  THE

 

COMMISSIONING PERIOD

.  

 

Running the radiator at maximum temperature for the

 

first few days will help to dispel any smells 

more quickly.

 

Please note that at high setting the room temperature will be warmer with a

 

corresponding 

increase in running costs.

 

 

Safety - Overheat Protection 

 

For your safety, this appliance is fitted with thermal cut-outs. In the event that the

 

product 

overheats, the cut-outs switch the radiator off automatically. In the event of

 

these safety cut-

outs activating please inform the installer or the LHZ Help Desk.

 

 

 

 


background image

 

 

10  

 

 

 

 

 

Manual TT-KS 

GB

 

 

 

Cleaning 

 

To maintain the external appearance of the radiator it need only be wiped over

 

occasionally 

with a dry duster. During the summer months, or at other times when the

 

appliance is not is  

use and is completely cold, the opportunity should be taken to wipe

 

over with a damp cloth.

 

Do not use abrasive cleaning powders or furniture polish.

 

Discoloration of wall finishes can 

sometimes occur immediately above a radiator due to

 

the properties of some paints and 

decorating materials or the presence of

 

environmental impurities in the air (such as soot or 

incense generated from the burning

 

of candles etc.). 

 

6. Regulation 

 

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of 

the Ecodesign requirements 2015/1188. 

The installation and commissioning of the devices is only permitted in conjunction with external 

room temperature controllers that fulfill the following functions: 

 

  electronic room temperature control plus week timer 

 

And has at least one of the following properties: 

 

  room temperature control, with presence detection 

  room temperature control, with open window detection 

  with distance control option 

  with adaptive start control 

  with working time limitation 

  with black bulb sensor 

   

The following room temperature controller systems 

 

  RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-

Interface (Art.Nr.750 000 640) or 

  DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101) 

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

 

  electronic room temperature control plus week timer (RF/DSM) 

  room temperature control, with open window detection (DSM) 

  with distance control option (DSM) 

  with adaptive start control (DSM) 

 

Use of the TT-KS Standard range (without external thermostat control) is only permitted with castors 

or on feet. 

 

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page. 

 

Failure to comply with these requirements will result in the loss of the CE mark. 

 

 

 


background image

 

 

11  

 

 

 

 

 

Manual TT-KS 

Model: TT-KS S DSM / TT-KS N DSM / TT-KS H DSM (additional DSM interface necessary) 

Item 

Symbol 

Value 

Value 

Item

 

Value 

Heat output 

Type of heat input, for electric storage local 

space heaters only (select one) 

Nominal heat 

output 

Pnom

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge control, with 

integrated thermostat 

No 

Minimum heat 

output 

(indicative) 

Pmin

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge control with 

room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous heat 

output 

Pmax,c

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

electronic heat charge control with 

room and/or outdoor 
temperature feedback 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

 

 

 

 

fan assisted heat output 

No 

At nominal heat 

output 

elmax

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

Type of heat output/room temperature 

control (select 
one) 

At minimum heat 

output 

elmin

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

single stage heat output and no room 

temperature control 

No 

In standby mode 

elSB

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

Two or more manual stages, no room 

temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with mechanic thermostat room 

temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with electronic room temperature 

control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control 

plus day timer 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control 

plus week timer 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

Other control options (multiple selections 

possible) 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with 

presence detection 

Nein 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with open 

window detection 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

with distance control option 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

with adaptive start control 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

with working time limitation 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with black bulb sensor 

No 

Model: TT-KS S RF / TT-KS N RF / TT-KS H RF (additional TPF Thermostat and Eco-Interface necessary) 

Item 

Symbol 

Value 

Value 

 

Item

 

Value 

Heat output 

Type of heat input, for electric storage local 

space heaters only (select one) 

Nominal heat 

output 

Pnom

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge control, with 

integrated thermostat

 

No 

Minimum heat 

output 

(indicative) 

Pmin

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge control with 

room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous heat 

output 

Pmax,c

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

electronic heat charge control with 

room and/or outdoor 
temperature feedback

 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

 

 

 

 

fan assisted heat output

 

No 

At nominal heat 

output 

elmax

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

Type of heat output/room temperature 

control (select 
one)

 

At minimum heat 

output 

elmin

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

single stage heat output and no room 

temperature control

 

No 

In standby mode 

elSB

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

Two or more manual stages, no room 

temperature control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with mechanic thermostat room 

temperature control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with electronic room temperature 

control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control 

plus day timer

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control 

plus week timer

 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

Other control options (multiple selections 

possible)

 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with 

presence detection

 

Nein 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with open 

window detection

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with distance control option

 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

with adaptive start control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with working time limitation

 

nein 

 

 

 

 

 

 

 

 

 

 

 

 

with black bulb sensor

 

nein 

Contact details: 

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt 

 

 

 


background image

 

 

12  

 

 

 

 

 

Manual TT-KS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lucht LHZ Elektroheizung GmbH & Co. KG 

Reinhard-Schmidt-Str. 1 

D-09217 Burgstädt 

Fon: +49 (0) 3724 66869 0 

Fax: +49 (0) 3724 66869 20 

E-mail: info@technotherm.de 

web: 

www.technotherm.de

 

 

 

 

 

 

 

 

 

 

edition: 12/17

 

Model: TT-KS S E4 / TT-KS N E4 / TT-KS E4  (only additional with castors of feet´s) 

Item 

Symbol 

Value 

 

 

 

 

 

 

 

Value 

 

Item

 

Value 

Heat output 

Type of heat input, for electric 

storage local space heaters only 

(select one) 

Nominal heat 

output 

Pnom

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge 

control, with integrated 

thermostat 

No 

Minimum heat 

output 

(indicative) 

Pmin

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

manual heat charge control 

with room and/or outdoor 

temperature feedback 

No 

Maximum 

continuous heat 

output 

Pmax,c

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

electronic heat charge 

control with room and/or 

outdoor 
temperature feedback 

No 

Auxiliary 

electricity 

consumption 

 

 

 

 

 

 

 

 

 

 

 

fan assisted heat output 

No 

At nominal heat 

output 

elmax

 

500 

1000 

1200 

1500 

1800 

2000 

2400 

2800 

Watt 

 

Type of heat output/room 

temperature control (select 
one) 

At minimum heat 

output 

elmin

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

single stage heat output 

and no room temperature 

control 

No 

In standby mode 

elSB

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

Two or more manual 

stages, no room 

temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with mechanic thermostat 

room temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with electronic room 

temperature control 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room 

temperature control plus 

day timer 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room 

temperature control plus 

week timer 

No 

 

 

 

 

 

 

 

 

 

 

 

 

Other control options (multiple 

selections possible) 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, 

with presence detection 

Nein 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, 

with open window detection 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with distance control option 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with adaptive start control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with working time limitation 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with black bulb sensor 

No 

TECTECHNOTHERM Service: 

Fon: +49 (0)911-93 78 32 10