Full Text Searchable PDF User Manual

Feel good through warmth from electricity - www.technotherm.de
|1
Model
• PH Ultraslim
Instruction Manual -
PH
Ultraslim
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY
AND RETAINED FOR FUTURE REFERENCE. BE SURE
TO OBSERVE ALL LABELS AND WARNINGS ON THE
APPLIANCE
Id.-Nr. 900 370 411
Edition :01/18

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
2|
1. PRESENTATION
First of all, we would like to thank you for having bought this product; we hope that it will give you ye
-
ars of reliable heating. Before installing the heater, please read the following instructions carefully. The
company is not responsible for any damage or problems resulting from incorrect installation. Once your
heater is up and running, please store this booklet in a safe place for future reference.
RECYCLING
When you no longer need this heater, please follow the European Directive 2002/96/CE as regards its
disposal. This heater cannot be discarded as normal rubbish. It must either be taken to a
special tip or to a distributor offering to dispose for you. Recycling electrical appliances sepa
-
rately allows component parts to be re-used and limits the damage to the environment that
would otherwise occur. Recycling saves power and resources. To encourage this, the heater
bears a symbol showing it cannot be put into a normal bin. For further information, get in touch with
your local council, or the supplier who you purchased this product.
VERY IMPORTANT!!
It is possible that the radiator may make slight sounds during the first days of operation. This is quite
normal in dry radiators and can occur when the aluminium elements expand and contract. Please note
there is no danger to the user. Children under 3 years old should be kept out of the equipment unless
they are constantly supervised. Children under 8 must only turn on / off the device provided in normal
position and only if they have received instruction concerning use of the equipment in a safe way and
understand the risks. All children under 8 years should not plug regulating, cleaning or maintenance
operations.
Caution: some parts of this product may become very hot and cause burns. Special attention when
children and vulnerable people are present. The device must not be covered and air circulation must
be allowed at all times.
2. HOW TO USE YOUR ELECTRIC RADIATOR
Understanding the full programming potential of your radiator will help to reduce energy consumption.
• DISPLAY
The radiator has an electronic programmable thermostat with LCD screen specially designed to control
different types of heating options.
1.Operating mode menu (all active modes are framed).
2.Program number or parameters number.
3.Installation parameter menu.
4.Type of time display (12H am/pm or 24H)
5.Key lock function indicator.
6.Current day of the week
7.Pictogram for program creation, status in normal mode.
8.Display zone for Time, Temperatures and parameters.
9.Override function in AUTO mode or ITCS function activated if blinking.
10.Room temperature indicator.
11.Pictogram for open widows indication
12.Heating demand.

Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
|3
• KEYBOARD
On/Off
Minus Key
-
Plus Key
+
Validation Key
OK
Right Navigation key
>
3. FIRST INSTALLATION
This section will help guide you to starting your thermostat for the first time.
• POWER SUPPLY
Connect the electric radiator with the switch installed for this function.
When the thermostat is switched on for the first time, you will be asked to make some necessary selec
-
tions (Clock, etc.). The batteries inside the thermostat will need to be charged for a minimum of 24 hours
in order to have maximum time saving capacity.
Now your thermostat will require adjustment of the time and date.
• TIME AND DATE ADJUSTMENT
First move the square cursor on the clock mode, then press the key (-) or (+) to start the adjustment.
Each time a value blinks, you can adjust it with the (-) and (+) keys.
Once the value is chosen, confirm it with the (OK) key. The thermostat will move automatically to the next
value. List order of the time and date adjustments:
1.Time and day:
Adjustment of the hours,
Adjustment of the minutes
Adjustment of the day (1 = Monday)
2.Date:
Adjustment of the day number
Adjustment of the Month (01=January, 12=December)
Adjustment of the Year
• STARTING
The thermostat is now ready to work. The default working mode will be comfort . At any time, when the
light is off, press the OK, “-“, “+” or . Press OK and then press the second time to show the fixed tempe
-
rature.
•
ON/OFF
Press key to turn off or turn on the radiator,
If the period in which the radiant heater is not going to be working, place the main switch in the Off posi
-
tion.
4. MODES OF OPERATION
How to change the working mode?
Use the navigation key right (>) to display the working mode line.
Move the frame cursor on the desired working mode and press (OK) to enter
in the operating mode you have chosen.

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
4|
• TIMER MODE
The Timer mode allows you to adjust the temperature and the duration for a specific time.
- This function can be used when you stay at home for several days, or if you want to override
the programfor some time.
- You can first adjust the duration in hours “H” if below 24H, then in days “d” with (-) or (+),
press (OK) toconfirm. (Adjustable from 1 hour up to 44 days)
- You can also adjust the desired setting temperature to start the function. (Default value 24°C).
The logo shines. By pressing the button “OK” the number of hours /days remaining is displayed until
the end of the period.
If you want to stop the timer function before the end, set the duration period to “no” with (-) key.
• MANUAL MODE COMFORT
Manual working mode, the comfort temperature setting will be followed 24 hours a day / 7 days a
week. By pressing (-) or (+) keys, the temperature can be adjusted accordingly.
• AUTOMATIC MODE
With this mode the thermostat will follow the chosen program (Built-in or customised) according to the
actual time and the Comfort and Reduced temperature settings.
You can easily override the current program temperature by changing the value with (-) or (+). The
current setting temperature will blink. The small hand logo will be displayed when the override
function is active. The original temperature settings will return when the timer reaches the next change
in the programme.
If hand logo blinks then ITCS is active (See the user menu for more explanation on this function).
• MANUAL MODE REDUCED
During manual working mode the reduced temperature setting will be followed 24 hours
a day / 7 days a week. By pressing (-) or (+) keys, the temperature starts to blink and can
be adjusted.
• ANTIFREEZE MODE
Use this mode if you want to protect your radiator against freezing when going on holiday...
The anti-freeze setting temperature is fixed and can be adjusted in the parameter menu number 05 ‘AF’,
see chapter 6 (default value 5°C).
• TIME AND DATE ADJUSTMENT
See the paragraph of “TIME AND DATE ADJUSTMENT” described above.
5. PROGRAMMING WEEKLY
Select the mode with the keys of displacement
When you enter in the Program mode, the first operation is to choose the program number using the
(-) or (+) keys you can choose between a built-in program P1 to P9 or a user program U1 to U4. Select a
program and press (OK) to validate.
Programm number
Day

Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
|5
If you select a built-in program P1 to P9, you can view and select only one of the following pre-set program
options.
•
P1, Comfort mode in:
Days working: from 07:00 to 09:00 h and from 17:00 to 11:00 h.
Weekend:
from 08:00 to 23:00 h.
•
P2, Comfort mode in:
Days working: from 07:00 to 9:00 h, from 12:00 to 14:00 h and from 17:00 to 23:00 h.
Weekend:
from 08:00 to 23:00 h.
•
P3, Comfort mode in:
Days working: from 06:00 to 23:00 h.
Saturday:
from 07:00 to 24:00 h.
Sunday:
from 00:00 to 00:01 h and from 07:00 to 23:00 h.
•
P4, Comfort mode in:
Days working: from 15:00 to 23:00 h.
Saturday:
from 07:00 to 24:00 h.
Sunday:
from 00:00 to 00:01 h and from 07:00 to 23:00 h.
•
P5, Comfort mode in:
Days working: from 06:00 to 08:00 h and from 21:00 to 23:00 h.
Saturday:
from 18:00 to 24:00 h.
Sunday:
from 18:00 to 23:00 h.
•
P6, Comfort mode in:
Days working: from 06:00 to 08:00 and from 14:00 to 20:30 h.
Weekend:
from 07:00 to 20:30 h.
•
P7, Comfort mode in:
Days working: from 07:00 to 19:00 h.
Weekend:
Inactive.
•
P8, Comfort mode in:
Days working: from 08:00 to 19:00 h.
Saturday:
from 08:00 to 18:00 h.
Sunday:
Inactive.
•
P9, Comfort mode in:
Monday:
from 00:00 to 7:00 h.
Tuesday – Friday:
Inactive.
Weekend:
from 00:00 to 24:00 h.
If you select a user program U1 to U4 as mentioned above you can choose the program, view it and also
amend it.
Default setting:
•
U1, U2, U3, U4 = x4 bespoke programme options (7 days a week)
•
Press and hold the confirmation key (OK) to customise a user program
How to create a user program:
•
The program creation will always start with day 1 (Monday).
•
The (>) Button switches between the ECO temperature and the COMFORT temperature mode
in the time displayed on the screen.

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
6|
•
The (+) key increased time in intervals of 30 minutes keeping the selected mode. Once you reach
the time you want to change the temperature mode press the (>)key.
•
Configure your programme using the instructions above until you reach midnight and the word
‘COPY’ will be displayed. Press the (+) button to select the days you want to copy the program. Press
the (OK) key and using the (+) key select „YES“ if you wish them to copy or ‚NO‘ if you do not wish
to copy.
•
If not is selected for any of the days then please configure using the instructions above until the last
day of the week.
After validating the seventh day, the system automatically returns to AUTO mode and your programme
mode will appear in the top right corner. For extra assistance, please contact the seller for a step by
step guide.
6. SPECIAL FUNCTIONS
• FUNCTION WINDOWS OPEN
This function will stop the radiator automatically when it detects a window open if the
radiator is running. When this feature is enabled, the icon appears at the top left of
the screen. If the system detects a fall of approximately 3 °C, it stops the heating for a
period of 1 hour. The icon will blink and the temperature will be measured by the ra
-
diator. Pressing any button at this stage will stop the detection of open windows. The
radiator will begin to function normally again and will restarts the detection of open
windows.
• POWER CONSUMPTION
Select the mode with the keys of displacement
In this screen you will see the power consumption (KWh) by pressing the button (+) in
the last 24 h (1 d), in the last 7 days (7 d) and in the last month (30).
The control of the electric radiator, computes the time in which the team has State
heating with the power of the radiator. The value of power of the radiator (default 900
W) must be correct to do so, if this value is not on your radiator you must replace it
with the correct. You can see how this value is changed in „Menu parameters“, 10 (Pow)
„Power setting“ menu.
• MENU PARAMETERS
Your thermostat has a parameter’s menu. To enter this menu, press and maintain the
validation key (OK) for 5 seconds. Then the parameter menu will appear and the first
menu screen will be displayed.
Now you can select the parameters which must be adjusted with the navigation keys
( ). Press the (OK) key to edit the parameter that you wish to modify and change its
value with (+) or (-), then confirm with (OK).
Program number
Time
Day
Actual mode
Day

Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
|7
Nº Default value & other possibilities
1
ProG
: Display type: simple and complete
No: Simple
Yes: Complete, all functions are available
2
dEG
: Type of degrees displayed
°C Celsius
°F Fahrenheit
3
24h
: Selection of the clock
24H (24:00)
12H (12:00 AM /PM)
4
dSt
: Daylight summer time.
Yes the automatic change over time between Summer and Winter is activated according to date
No no daylight summer time automatic change.
5
AF
: Anti Freeze temperature:
This Anti-freeze temperature used in Holiday mode.
Adjustable 0.5 to 10.0°C with default value 5.0°C.
6
_ ._
: Calibration of the internal probe
The calibration must be done after 1 day working with the same setting temperature in
accordance with the following description:
Put a thermometer in the room at 1.5M distance from the floor (like the thermostat) and check
the real temperature in the room after 1 hour.
When you enter on the calibration parameter the actual value is displayed.
To enter the value shown on the thermometer, use the (-) or (+) keys to enter the real value. Then,
press (Ok) to confirm. The logo should be displayed, to inform that a calibration is now made
and saved in the memory. If you need to erase a calibration already made press on the
navigation key left ( ). Then the logo must disappear.
* Pay attention: Only the heating element managed by the thermostat must be used during the
complete step of the calibration.
7
ITCS
: Intelligent Temperature Control System
The Intelligent Temperature Control System will activate your installation in advance (2 hours
maximum) to assure the desired temperature at the hour programmed following your weekly pro
gram. This automatic control system works in the following way:
When you start your thermostat for the first time, it will measure the time taken by your
installation to reach the set temperature. The thermostat will re-measure this time at each pro
gram change to compensate external temperature change & influence. You can now program
your thermostat without the need to adjust the temperature in advance because your
thermosat does it automatically for you.
8
WIN
: Automatic detection of open windows.
This feature allows detect automatically if you open a window.
No: deactivation of the function.
Yes: Activate the function
9
Chil
: Adjustment % of the power of the radiator electric. 25, 50, 75 and 100% power
10
POW
: Adjustment of the power of the radiator electric.
In this menu you can choose the value of the power of your radiator electric to adjust
the calculation of the consumption of your radiator. Default: 900 W
11
Clr
: Factory setting
Press and maintain (Ok) key during 10s to reset Set points temperatures and user parameters in
this menu to factory default settings. User programs will also be resetted.

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
8|
* Pay attention:
Ensure that you have all necessary elements to re-setup your installation before to use this
function.
12 Software version
_._
13
End
: Exit the parameter’s menu
Press (OK) key to exit installation parameter menu and return to normal operation.
7. TECHNICAL CHARACTERISTIC
Measured temperature precision
0.1°C
Environmental:
•
Operating temperature
•
Shipping and storage temperature
0°C - 35°C
-10°C to +50°C
Setting temperature range
•
Comfort, Reduced
•
Timer
5°C to 30°C by 0,5°C step
5°C to 19°C by 0,5°C step
Regulation characteristics
Proportional band (PWM)
Power Supply
230Vac +/- 10% 50Hz
Output
•
Maximum Load (Resistive only)
TRIAC 230Vac
10 Amps (2000W)
Software Version
Displayed in the user menu.
Norms and directives:
Your thermostat was designed in accordance with the follo
-
wing Europeans norms and directives:
EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
EN 61000-4-2 : 2001
Low voltage 2006/95/EC
EMC 2004/108/EC
8. TROUBLESHOOTING & SOLUTION
My Thermostat doesn’t work
Power supply
- Check the power supply
My Thermostat show an Error message “
Err
” blink on the display
“
Error
” on sensor
Note:
For safety if there is a problem on the regulation sensor the
regulation will be replaced by a rate of 5 % functioning.
The logo and the text “
Err
” blinks. Error detected on
the internal sensor
- Contact your installer or seller.
My
Thermostat
seems work correctly but the heating doesn’t work correctly
Output
- Check the connections.
- Check the power supply of the heating element.
- Contact your installer.
My
Thermostat
seems work correctly but the temperature in the room was never in accordance with the program.
Program
- Check the Clock.
-The difference between Comfort & Reduced temperature
is too high?
- The step in the program is too short?
- Check the pilot wire function.

Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
|9
9. INSTALLATION
• BEFORE INSTALLING
Whilst the installation of this heater is straightforward, please ensure you read the following carefully as
the manufacturer will not be liable for any damage or problems arising from incorrect installation.
Unwrap your heater and clear the packaging away. The packaging has been specifically chosen to allow
you to recycle it. If on unpacking, you discover any damage whatsoever, please get in touch with your sup
-
plier within 24 hours and prior to installation.
For assembly and installation, please follow the instructions as set out in this booklet. For safety reasons,
this heater should never be installed in close proximity to a bath or shower i.e. that you could touch the
controls whilst in the bath or shower. The radiator should not be placed below a socket. If the cable has
been damaged, it can only be replaced by the manufacturer, through its aftersales team, or by a qualified
person. This ensures the user will not be in any danger. At the end of the manual, you will find a Guarantee,
please check that this has been completed correctly, dated and stamped
Very important:
- Read installation manual prior to installation of this unit!
- Read user manual before putting this unit in operation!
- Observe the warnings in the manuals!
- The installation room must fulfil the ventilation requirements!
- Installation by an authorised person only!
• CONNECTING ELECTRICITY SUPPLY
- If the Thermal Emitter that you have acquired does not have a plug on the supply cord, installati
on shouldbe carried out by a qualified electrician.
- Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring
rules of thecountry where it is to be installed.
- Before connecting, check the supply is switched off.
- Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the
ratedvalues indicated in the marking plate 220 - 240V.
- The appliance must be connected to the fused system of fixed wiring.
- Any problem arising from not following the instructions above will invalidate your guarantee
- When wiring up, please follow the colours of wires.
• HANGING THE HEATER
The radiator comes complete with an installation kit, comprising the following:
- Screws
- Brackets
Cardboard guide, (remove from the top of the box the radiator comes in).
Please follow the illustrated steps below to hang and install your radiator:
1.
Take the radiator out of its packaging and choose whereto hang it.
Please note the minimum distances requiredaround the heater.
2.
Remove the cardboard guide from the lid of the box andplace it at the
right height. We suggest you use a levelto ensure the radiator is hung
square. Using the holesas your guide, mark where the brackets need
to go.
3.
Drill and plug the holes.
4.
Screw the brackets to hold the radiator into place, usingthe screws and washers provided.
5.
Hang the radiator using the brackets.
6.
Mark the position of the hooks drill and plug holes andscrew in place.

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
10|
7.
Use a hole drill for holes with appropriate stoppers for the type of wall.
8.
Place the radiator brackets in place using the supplied screws, stoppers and washers.
9.
Approach the radiator to the brackets so that the grooves match with the ones on the bracket.
10.
Hang the radiator and secure it with the screws.

Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
|11
10. GUARANTEE.
The manufacturer produces high quality products for international markets. The company provides a
technical guarantee for the period of 2 years maximum. For this warranty to be valid you must present
the original invoice, delivery note or ticket.
Prerequisites:
•
The guarantee only covers manufacturing defects and/or any problem occurring from such defects.
Allproblems arising from installing and undersized heater (not enough heat, improper installation,
etc) are notcovered by this guarantee.
•
This heater is for domestic & light commercial use only, installation in any other environment voids
thisguarantee
•
Technotherm reserves the right to decide whether to repair or replace any defective part or to
replace the entire heater.
•
All costs arising from any damage caused by incorrect usage, transport, electrical supply are not
coveredby this guarantee, nor is any malicious damage.
This guarantee does provide compensation for incidental or consequential damage or injuries.

Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
12|
TECHNOTHERM Support
+49 (0) 911 937 83 210
TECHNOTHERM a brand of Lucht LHZ GmbH & Co. KG
Reinhard-Schmidt-Str. 1 | 09217 Burgstädt | Germany
Telefon: +49 (0) 3724 66869 0
Telefax: +49 (0) 3724 66869 20
info@technotherm.de | www.technotherm.de
Subject to errors and technical amendments. Dimensions without guarantee! Edition 10/17
Information requirements for electric local space heaters
Model: PH Ultraslim
Item
Symbol
Value
Value
Item
Value
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
P
nom
0,9
1,5
2,0
kW
manual heat charge control, with integrated thermostat
NO
Minimum heat
output (indicative)
P
min
0,5
1,0
1,2
kW
manual heat charge control with room and/or outdoor temperature
feedback
NO
Maximum continuo-
us heat output
P
max,c
0,5
1,0
1,2
kW
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electrici-
ty consumption
fan assisted heat output
NO
At nominal heat
output
el
max
0,9
1,5
2,0
kW
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
1,2
1,2
1,2
kW
single stage heat output and no room temperature control
No
1,2
1,2
1,2
Two or more manual stages, no room temperature control
No
In standby mode
el
SB
1,2
1,2
1,2
kW
with mechanic thermostat room temperature control
N0
1,2
1,2
1,2
with electronic room temperature control
No
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
Yes
Other control options (multiple selections possible)
room temperature control, with presence detection
No
room temperature control, with open window detection
Yes
with distance control option
No
with adaptive start control
Yes
with working time limitation
No
with black bulb sensor
No
Contact Information:
Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt