Feel good through warmth from electricity - www.technotherm.de

|1

Model

• PH Ultraslim 

Instruction Manual -

      

 PH 

Ultraslim

 

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY 

AND RETAINED FOR FUTURE REFERENCE. BE SURE 

TO OBSERVE ALL LABELS AND WARNINGS ON THE 

APPLIANCE

Id.-Nr. 900 370 411

Edition :01/18

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

2|

1. PRESENTATION

First of all, we would like to thank you for having bought this product; we hope that it will give you ye

-

ars of reliable heating. Before installing the heater, please read the following instructions carefully. The 

company is not responsible for any damage or problems resulting from incorrect installation. Once your 

heater is up and running, please store this booklet in a safe place for future reference.

RECYCLING

When you no longer need this heater, please follow the European Directive 2002/96/CE as regards its 

disposal. This heater cannot be discarded as normal rubbish. It must either be taken to a 

special tip or to a distributor offering to dispose for you. Recycling electrical appliances sepa

-

rately allows component parts to be re-used and limits the damage to the environment that 

would otherwise occur. Recycling saves power and resources. To encourage this, the heater 

bears a symbol showing it cannot be put into a normal bin. For further information, get in touch with 

your local council, or the supplier who you purchased this product.

VERY IMPORTANT!!

It is possible that the radiator may make slight sounds during the first days of operation. This is quite 

normal in dry radiators and can occur when the aluminium elements expand and contract. Please note 

there is no danger to the user. Children under 3 years old should be kept out of the equipment unless 

they are constantly supervised. Children under 8 must only turn on / off the device provided in normal 

position and only if they have received instruction concerning use of the equipment in a safe way and 

understand the risks. All children under 8 years should not plug regulating, cleaning or maintenance 

operations.

Caution: some parts of this product may become very hot and cause burns. Special attention when 

children and vulnerable people are present. The device must not be covered and air circulation must 

be allowed at all times.

2. HOW TO USE YOUR ELECTRIC RADIATOR

Understanding the full programming potential of your radiator will help to reduce energy consumption.

•  DISPLAY

The radiator has an electronic programmable thermostat with LCD screen specially designed to control 

different types of heating options.

 

1.Operating mode menu (all active modes are framed).

 

2.Program number or parameters number.

 

3.Installation parameter menu.

 

4.Type of time display (12H am/pm or 24H)

 

5.Key lock function indicator.

 

6.Current day of the week

 

7.Pictogram for program creation, status in normal mode.

 

8.Display zone for Time, Temperatures and parameters.

 

9.Override function in AUTO mode or ITCS function activated if blinking.

 

10.Room temperature indicator.

 

11.Pictogram for open widows indication

 

12.Heating demand.

 


background image

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

|3

•  KEYBOARD

On/Off

Minus Key 

 

 

-

Plus Key 

 

 

+

Validation Key  

 

OK

Right Navigation key   

 >

3. FIRST INSTALLATION

This section will help guide you to starting your thermostat for the first time.

•  POWER SUPPLY

Connect the electric radiator with the switch installed for this function.

When the thermostat is switched on for the first time, you will be asked to make some necessary selec

-

tions (Clock, etc.). The batteries inside the thermostat will need to be charged for a minimum of 24 hours 

in order to have maximum time saving capacity.

Now your thermostat will require adjustment of the time and date.

•  TIME AND DATE ADJUSTMENT

First move the square cursor on the clock mode, then press the key (-) or (+) to start the adjustment.

Each time a value blinks, you can adjust it with the (-) and (+) keys.

Once the value is chosen, confirm it with the (OK) key. The thermostat will move automatically to the next 

value. List order of the time and date adjustments:

1.Time and day:

 

Adjustment of the hours,

 

Adjustment of the minutes

 

Adjustment of the day (1 = Monday)

2.Date:

 

Adjustment of the day number

 

Adjustment of the Month (01=January, 12=December)

 

Adjustment of the Year

•  STARTING

The thermostat is now ready to work. The default working mode will be comfort    . At any time, when the 

light is off, press the OK, “-“, “+” or      . Press OK and then press the second time to show the fixed tempe

-

rature.

• 

ON/OFF

Press key to turn off or turn on the radiator,

If the period in which the radiant heater is not going to be working, place the main switch in the Off posi

-

tion.

4. MODES OF OPERATION

How to change the working mode?

 

Use the navigation key right (>) to display the working mode line.

 

Move the frame cursor on the desired working mode and press (OK) to enter  

 

in the operating mode you have chosen.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

4|

•  TIMER MODE

The Timer mode allows you to adjust the temperature and the duration for a specific time.

 

- This function can be used when you stay at home for several days, or if you want to override  

 

   the programfor some time.

 

- You can first adjust the duration in hours “H” if below 24H, then in days “d” with (-) or (+),  

 

   press (OK) toconfirm. (Adjustable from 1 hour up to 44 days)

 

- You can also adjust the desired setting temperature to start the function. (Default value 24°C).

The     logo shines. By pressing the button “OK” the number of hours /days remaining is displayed until 

the end of the period.

If you want to stop the timer function before the end, set the duration period to “no” with (-) key.

•  MANUAL MODE COMFORT

Manual working mode, the comfort temperature setting will be followed 24 hours a day / 7 days a 

week. By pressing (-) or (+) keys, the temperature can be adjusted accordingly.

•  AUTOMATIC MODE

With this mode the thermostat will follow the chosen program (Built-in or customised) according to the 

actual time and the Comfort and Reduced temperature settings.

You can easily override the current program temperature by changing the value with (-) or (+). The 

current setting temperature will blink. The small hand         logo will be displayed when the override 

function is active. The original temperature settings will return when the timer reaches the next change 

in the programme.

If hand logo blinks then ITCS is active (See the user menu for more explanation on this function).

•  MANUAL MODE REDUCED

During manual working mode the reduced temperature setting will be followed 24 hours 

a day / 7 days a week. By pressing (-) or (+) keys, the temperature starts to blink and can 

be adjusted.

•  ANTIFREEZE MODE

Use this mode if you want to protect your radiator against freezing when going on holiday...

The anti-freeze setting temperature is fixed and can be adjusted in the parameter menu number 05 ‘AF’, 

see chapter 6 (default value 5°C).

•  TIME AND DATE ADJUSTMENT

See the paragraph of “TIME AND DATE ADJUSTMENT” described above.

5. PROGRAMMING WEEKLY

Select the mode      with the keys of displacement

When you enter in the Program mode, the first operation is to choose the program number using the 

(-) or (+) keys you can choose between a built-in program P1 to P9 or a user program U1 to U4. Select a 

program and press (OK) to validate.

Programm number

Day

 


background image

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

|5

If you select a built-in program P1 to P9, you can view and select only one of the following pre-set program 

options.

• 

P1, Comfort mode in:

 

Days working: from 07:00 to 09:00 h and from 17:00 to 11:00 h.

 

Weekend: 

from 08:00 to 23:00 h.

• 

P2, Comfort mode in:

 

Days working: from 07:00 to 9:00 h, from 12:00 to 14:00 h and from 17:00 to 23:00 h.

 

Weekend: 

from 08:00 to 23:00 h.

• 

P3, Comfort mode in:

 

Days working: from 06:00 to 23:00 h.

 

Saturday: 

from 07:00 to 24:00 h.

 

Sunday: 

from 00:00 to 00:01 h and from 07:00 to 23:00 h.

• 

P4, Comfort mode in:

 

Days working: from 15:00 to 23:00 h.

 

Saturday: 

from 07:00 to 24:00 h.

 

Sunday: 

from 00:00 to 00:01 h and from 07:00 to 23:00 h.

• 

P5, Comfort mode in:

 

Days working: from 06:00 to 08:00 h and from 21:00 to 23:00 h.

 

Saturday: 

from 18:00 to 24:00 h.

 

Sunday: 

from 18:00 to 23:00 h.

• 

P6, Comfort mode in:

 

Days working: from 06:00 to 08:00 and from 14:00 to 20:30 h.

 

Weekend: 

from 07:00 to 20:30 h.

• 

P7, Comfort mode in:

 

Days working: from 07:00 to 19:00 h.

 

Weekend: 

Inactive.

• 

P8, Comfort mode in:

 

Days working: from 08:00 to 19:00 h.

 

Saturday: 

from 08:00 to 18:00 h.

 

Sunday: 

Inactive.

• 

P9, Comfort mode in:

 

Monday: 

from 00:00 to 7:00 h.

 

Tuesday – Friday: 

Inactive.

 

Weekend: 

from 00:00 to 24:00 h.

If you select a user program U1 to U4 as mentioned above you can choose the program, view it and also 

amend it.

Default setting:

• 

U1, U2, U3, U4 = x4 bespoke programme options (7 days a week)

• 

Press and hold the confirmation key (OK) to customise a user program

How to create a user program:

• 

The program creation will always start with day 1 (Monday).

• 

The (>) Button switches between the ECO temperature and the COMFORT temperature mode

       in the time displayed on the screen.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

6|

• 

The (+) key increased time in intervals of 30 minutes keeping the selected mode. Once you reach 

the time you want to change the temperature mode press the (>)key.

• 

Configure your programme using the instructions above until you reach midnight and the word 

‘COPY’ will be displayed. Press the (+) button to select the days you want to copy the program. Press 

the (OK) key and using the (+) key select „YES“ if you wish them to copy or ‚NO‘ if you do not wish 

to copy.

• 

If not is selected for any of the days then please configure using the instructions above until the last 

day of the week.

After validating the seventh day, the system automatically returns to AUTO mode and your programme 

mode will appear in the top right corner. For extra assistance, please contact the seller for a step by 

step guide.

6. SPECIAL FUNCTIONS

•  FUNCTION WINDOWS OPEN

This function will stop the radiator automatically when it detects a window open if the 

radiator is running. When this feature is enabled, the     icon appears at the top left of 

the screen. If the system detects a fall of approximately 3 °C, it stops the heating for a 

period of 1 hour. The icon will blink and the temperature will be measured by the ra

-

diator. Pressing any button at this stage will stop the detection of open windows. The 

radiator will begin to function normally again and will restarts the detection of open 

windows.

•  POWER CONSUMPTION

Select the mode        with the keys of displacement

In this screen you will see the power consumption (KWh) by pressing the button (+) in 

the last 24 h (1 d), in the last 7 days (7 d) and in the last month (30).

The control of the electric radiator, computes the time in which the team has State 

heating with the power of the radiator. The value of power of the radiator (default 900 

W) must be correct to do so, if this value is not on your radiator you must replace it 

with the correct. You can see how this value is changed in „Menu parameters“, 10 (Pow) 

„Power setting“ menu.

•  MENU PARAMETERS

Your thermostat has a parameter’s menu. To enter this menu, press and maintain the 

validation key (OK) for 5 seconds. Then the parameter menu will appear and the first 

menu screen will be displayed.

Now you can select the parameters which must be adjusted with the navigation keys

( ). Press the (OK) key to edit the parameter that you wish to modify and change its 

value with (+) or (-), then confirm with (OK).

Program number

Time

Day

Actual mode

Day

 


background image

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

|7

Nº         Default value & other possibilities

1      

ProG

: Display type: simple and complete 

 

No: Simple

 

Yes: Complete, all functions are available

2          

dEG

: Type of degrees displayed

 

°C Celsius

 

°F Fahrenheit

3     

24h

: Selection of the clock 

 

24H (24:00)

 

12H (12:00 AM /PM)

4           

dSt

: Daylight summer time.

 

Yes  the automatic change over time between Summer and Winter is activated according to date

 

No no daylight summer time automatic change.

5           

AF

: Anti Freeze temperature:

 

This Anti-freeze temperature used in Holiday mode.

 

Adjustable 0.5 to 10.0°C with default value 5.0°C.

6           

_ ._

: Calibration of the internal probe

 

The  calibration  must  be  done  after  1  day  working  with  the  same  setting  temperature  in

 

accordance with the following description:

 

Put a thermometer in the room at 1.5M distance from the floor (like the thermostat) and check   

 

the real temperature in the room after 1 hour.

 

When you enter on the calibration parameter the actual value is displayed.

 

To enter the value shown on the thermometer, use the (-) or (+) keys to enter the real value. Then, 

 

press (Ok) to confirm. The logo     should be displayed, to inform that a calibration is now made

  

and saved in the  memory. If you need to erase a calibration already made press on the 

 

navigation key left (      ). Then the logo must disappear.

 

* Pay attention: Only the heating element managed by the thermostat must be used during the   

 

complete step of the calibration.

7           

ITCS

: Intelligent Temperature Control System

 

The Intelligent Temperature Control System will activate your installation in advance (2 hours

 

maximum) to assure the desired temperature at the hour programmed following your weekly pro 

 

gram. This automatic control system works in the following way:

 

When you start your thermostat for the first time, it will measure the time taken by your 

 

installation to reach the set temperature. The thermostat will re-measure this time at each pro   

             gram change to compensate external temperature change & influence. You can now program

  

your thermostat without the need to adjust the temperature in advance because your 

 

thermosat does it automatically for you.

8           

WIN

:  Automatic detection of open windows.

 

This feature allows detect automatically if you open a window.

 

No: deactivation of the function.

 

Yes: Activate the function

9       

Chil

:  Adjustment % of the power of the radiator electric. 25, 50, 75 and 100% power

10         

POW

:  Adjustment of the power of the radiator electric.

 

In  this  menu  you  can  choose  the  value  of  the  power of  your radiator  electric  to adjust 

 

the calculation of the consumption of your radiator. Default: 900 W

11         

Clr

: Factory setting

 

Press and maintain (Ok) key during 10s to reset Set points temperatures and user parameters in

 

this menu to factory default settings. User programs will also be resetted.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

8|

 

* Pay attention:

 

Ensure that you have all necessary elements to re-setup your installation before to use this 

 

function.

12         Software version

 

_._

13         

End

: Exit the parameter’s menu

 

Press (OK) key to exit installation parameter menu and return to normal operation.

7. TECHNICAL CHARACTERISTIC

Measured temperature precision

0.1°C

Environmental:

• 

Operating temperature

• 

Shipping and storage temperature

0°C - 35°C

-10°C to +50°C

Setting temperature range

• 

Comfort, Reduced

• 

Timer

5°C to 30°C by 0,5°C step

5°C to 19°C by 0,5°C step

Regulation characteristics

Proportional band (PWM)

Power Supply

230Vac +/- 10% 50Hz

Output

• 

Maximum Load (Resistive only)

TRIAC 230Vac

10 Amps (2000W)

Software Version

Displayed in the user menu.

Norms and directives:

Your thermostat was designed in accordance with the follo

-

wing Europeans norms and directives:

EN 60730-1 : 2003

EN 61000-6-1 : 2002

EN 61000-6-3 : 2004

EN 61000-4-2 : 2001

Low voltage 2006/95/EC

EMC 2004/108/EC

8. TROUBLESHOOTING & SOLUTION

My Thermostat doesn’t work
Power supply

- Check the power supply

My Thermostat show an Error message “

Err

” blink on the display

Error

” on sensor

Note:

For safety if there is a problem on the regulation sensor the 

regulation will be replaced by a rate of 5 % functioning.

          The logo and the text “

Err

” blinks. Error detected on 

the internal sensor

- Contact your installer or seller.

My 

Thermostat

 seems work correctly but the heating doesn’t work correctly

Output

- Check the connections.

- Check the power supply of the heating element.

- Contact your installer.

My 

Thermostat

 seems work correctly but the temperature in the room was never in accordance with the program.

Program

- Check the Clock.

-The difference between Comfort & Reduced temperature      

is too high?

- The step in the program is too short?

- Check the pilot wire function.

 


background image

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

|9

9. INSTALLATION

•  BEFORE INSTALLING

Whilst the installation of this heater is straightforward, please ensure you read the following carefully as 

the manufacturer will not be liable for any damage or problems arising from incorrect installation.

Unwrap your heater and clear the packaging away. The packaging has been specifically chosen to allow 

you to recycle it. If on unpacking, you discover any damage whatsoever, please get in touch with your sup

-

plier within 24 hours and prior to installation.

For assembly and installation, please follow the instructions as set out in this booklet. For safety reasons, 

this heater should never be installed in close proximity to a bath or shower i.e. that you could touch the 

controls whilst in the bath or shower. The radiator should not be placed below a socket. If the cable has 

been damaged, it can only be replaced by the manufacturer, through its aftersales team, or by a qualified 

person. This ensures the user will not be in any danger. At the end of the manual, you will find a Guarantee, 

please check that this has been completed correctly, dated and stamped

Very important:

 

- Read installation manual prior to installation of this unit!

 

- Read user manual before putting this unit in operation!

 

- Observe the warnings in the manuals!

 

- The installation room must fulfil the ventilation requirements!

 

- Installation by an authorised person only!

•  CONNECTING ELECTRICITY SUPPLY

 

- If the Thermal Emitter that you have acquired does not have a plug on the supply cord, installati 

 

  on shouldbe carried out by a qualified electrician.

 

- Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring  

 

  rules of thecountry where it is to be installed.

 

- Before connecting, check the supply is switched off.

 

- Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the  

 

  ratedvalues indicated in the marking plate 220 - 240V.

 

- The appliance must be connected to the fused system of fixed wiring.

 

- Any problem arising from not following the instructions above will invalidate your guarantee

 

- When wiring up, please follow the colours of wires.

•  HANGING THE HEATER

The radiator comes complete with an installation kit, comprising the following:

 

- Screws

 

- Brackets

Cardboard guide, (remove from the top of the box the radiator comes in). 

Please follow the illustrated steps below to hang and install your radiator:

1. 

Take the radiator out of its packaging and choose whereto hang it.  

     Please note the minimum distances requiredaround the heater.

2. 

Remove the cardboard guide from the lid of the box andplace it at the     

    right height. We suggest you use a levelto ensure the radiator is hung     

    square. Using the holesas your guide, mark where the brackets need 

    to go.      

3. 

Drill and plug the holes.

4. 

Screw the brackets to hold the radiator into place, usingthe screws and washers provided.

5. 

Hang the radiator using the brackets.

6. 

Mark the position of the hooks drill and plug holes andscrew in place.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

10|

7. 

  Use a hole drill for holes with appropriate stoppers for the type of wall.

8. 

  Place the radiator brackets in place using the supplied screws, stoppers and washers.

9.

   Approach the radiator to the brackets so that the grooves match with the ones on the bracket.

10.

 Hang the radiator and secure it with the screws.

 


background image

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

|11

10. GUARANTEE.

The manufacturer produces high quality products for international markets. The company provides a 

technical guarantee for the period of 2 years maximum. For this warranty to be valid you must present 

the original invoice, delivery note or ticket.

Prerequisites:

• 

The guarantee only covers manufacturing defects and/or any problem occurring from such defects. 

Allproblems arising from installing and undersized heater (not enough heat, improper installation, 

etc) are notcovered by this guarantee.

• 

This heater is for domestic & light commercial use only, installation in any other environment voids 

thisguarantee

• 

Technotherm reserves the right to decide whether to repair or replace any defective part or to 

replace the entire heater.

• 

All costs arising from any damage caused by incorrect usage, transport, electrical supply are not 

coveredby this guarantee, nor is any malicious damage.

This guarantee does provide compensation for incidental or consequential damage or injuries.

 


background image

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

12|

TECHNOTHERM Support

+49 (0) 911 937 83 210

TECHNOTHERM a brand of Lucht LHZ GmbH & Co. KG

Reinhard-Schmidt-Str. 1 | 09217 Burgstädt | Germany

Telefon:  +49 (0) 3724 66869 0

Telefax:   +49 (0) 3724 66869 20

info@technotherm.de | www.technotherm.de

Subject to errors and technical amendments. Dimensions without guarantee! Edition 10/17

Information requirements for electric local space heaters

Model: PH Ultraslim

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

P

nom

0,9

1,5

2,0

kW

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

0,5

1,0

1,2

kW

manual heat charge control with room and/or outdoor temperature 

feedback

NO

Maximum continuo-

us heat output

P

max,c

0,5

1,0

1,2

kW

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electrici-

ty consumption

fan assisted heat output

NO

At nominal heat 

output

el

max

0,9

1,5

2,0

kW

Type of heat output/room temperature control (select

one)

At minimum heat

output

el

min

1,2

1,2

1,2

kW

single stage heat output and no room temperature control

No

1,2

1,2

1,2

Two or more manual stages, no room temperature control

No

In standby mode

el

SB

1,2

1,2

1,2

kW

with mechanic thermostat room temperature control

N0

1,2

1,2

1,2

with electronic room temperature control

No

electronic room temperature control plus day timer

No

electronic room temperature control plus week timer

Yes

Other control options (multiple selections possible)

room temperature control, with presence detection

No

room temperature control, with open window detection

Yes

with distance control option

No

with adaptive start control

Yes

with working time limitation

No

with black bulb sensor

No

Contact Information:

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1  D-09217 Burgstädt