PDF User Manual

  1. Home
  2. Manuals
  3. Technotherm ISP-W 450 Installation And Technical Manual

Technotherm ISP-W 450 Installation And Technical Manual

ISP-W 350\ ISP-W 600\ SP-W 750\ ISP-W 950\ ISP-W 1200\ ISP-R 450\ ISP-R 350\ ISP-R 600\ ISP-R 950\ ISP-R 750\ ISP-R 1200\ ISP-B 350\ ISP-B 450\ ISP-B 600\ ISP-B 950\ ISP-B 750\ ISP-Motiv 450\ ISP-Motiv 750\ ISP-Motiv 950\ ISP-W 351\ ISP-W 651\ ISP-W 501\ SP-W 851\ SP-R 501\ SP-R 651\ ISP-B 351\ SP-R 851\ ISP-R 351\ ISP-B 501\ SP-B 851\ ISP-B 651

Made by: Technotherm
Type: Installation And Technical Manual
Category: Heater
Pages: 10
Size: 1.25 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

 

 

 

 

 

Installation and

 

technical manual

 

 ISP-W / R / B / Motifs frameless – with receiver RF

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

GB

 

13

 

 

14

 

ISP-W 350 - 1200 

ISP-R  350  - 1200 

ISP-B  350  - 1200 

 

ISP-Motif 350 – 1200 
 

ISP-W 351 - 851 

ISP-R  351 - 851 

ISP-B  351 - 851 

 

ISP-Motif 351 till 851 

 

with receiver RF 

 

 

Edition: 12/17 

No. 911 360 671 

 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

1. Important Safety instructions 

 

People (including children) who are limited in their physical, 

sensory, or mental capacities should not use this device at any 

time. Furthermore do not handle this instrument if you do not 

possess the necessary experience and knowledge to do so. This 

device should only be handled under the supervision of a qualified 

person and after a thorough introduction. 

 

Do not leave children alone with the device, and supervise them at 

all times to keep them from getting harmed. 

 

WARNING: Do not cover! Otherwise this instrument will 

overheat. 

 

Do not place the heater underneath a socket, drainage or the like. 

 

To keep from getting burned, do not touch heater´s surface 

whenever it is turned on. 

 

Please use the handle whenever you have to move the heater. 

 

Do not put the cord underneath the carpet or a rug and make sure 

that it is not a tripping hazard 

 

Plug the heater into properly grounded sockets only. 

 

Do not use the heater in any other way than described in the user 

manual. Any other way of use may lead to fire, electrocution, and 

may cause serious harm to the person. 

 

Do not use this device near bathtubs, showers or swimming pools. 

 

In case the connection cable is damaged it has to be replaced by 

the manufacturer or someone commissioned by the manufacturer. 

WARNING: Do not use a switching-oriented device, like a timekeeper, 

when operating this heater. This could cause a change in the thermal 

adjustment which is potentially hazardous! 

 

 

To keep the device from overheating do not put towels or clothing 

on top. 

 

When using the heater, make sure it is in an upright position and 

positioned on an even and dry place. 

 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

 

Do not put any foreign objects into the vent. This may cause 

electrocution, fire or damage to the heater. 

 

Do not use an extension cord unless approved by an electrician. 

 

This device is for private use only, do not use in any other way than 

intended by the manufacturer. 

 

Do not use the device near curtains, highly combustible, extremely 

explosive or malleable materials. 

 

Keep a distance of a at least 1.0 m between combustible materials- 

like furniture, cushions, bedding, paper, clothing, curtains-and the 

heating device. 

 

Do not use the device in rooms were petrol, paint or any other 

flammable liquids are stored. 

 

Do not use the device outside. 

 

Warning! This device has to be grounded 

 

This device may only be operated using alternating current and 

the operating voltage indicated on the power rating plate 

 

 

Nominal Voltage            230V AC, 50 Hz 

 

Protection class  I 

ISP-W (white front panel, powder-coated) 
ISP-R (red front panel, powder-coated) 
ISP-B (black front plate, powder coated) 
ISP-Motif (front plate with motifs) 

Prior to commissioning, please inform yourself about proper installation, commissioning, operation and 

maintenance. 

Below we give the necessary information: 

The installation and electrical connection must be carried out by a qualified electrician. The panels are 

designed for wall and ceiling mounting. 

 

Wall mounting model ISP W / R / B / Motif 

 

The plate can be mounted horizontally or vertically.  Drill mounting holes as indicated in Fig.1 

(horizontally) or as in Fig.2 (vertically). The pack contains 4 (6 for the Models ISP 1200 and ISP 851) fixing 

screws 6 x 70 mm. 

 

To mounting the unit using all 4 (6 anchors for the Models ISP 1200 and ISP 851. The recommended 

dowel size is 10 mm (not included). 

The dimensions A and B are pitches of the holes to be drilled. 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

 

 

 

 

 

 

 

 

Distances 

The distance between the lower edge of the heater from the floor must be at least 50 mm, 150 mm are 

recommended. 
Side distance, 
for example, to 
furniture must 
be at least 100 
mm and the 
distance up at 
least 100 mm 
(see Abb. 2). In 

bathrooms, the heating plate is in compliance with the 
standard VDE 100 / T701 to install. It can be mounted as shown in Abb. 1 from field 2 (range 1 is not 
allowed!) 
The ISP heater is a product of protection class II, protection IP 44. The plate shall be affixed directly to 
the junction box. 

 

All models with the 

width of 

600 mm

 

incl. RF

 

drill spacing holes 

A1  [mm] 

B1 [mm] 

A2 [mm] 

B2 [mm] 

ISP 350 

324 

360 

360 

324 

ISP 450 

624 

360 

360 

624 

ISP 600 

624 

360 

360 

624 

ISP 750 

924 

360 

360 

924 

ISP 950 

1224 

360 

360 

1224 

ISP 1200 

1524  A1/2 = 762 

360 

360 

1524 

B2/2=762 

All models with 

the width of 

400 

mm

 

incl. RF

 

drill spacing holes 

A1  [mm] 

B1 [mm] 

A2 [mm] 

B2 [mm] 

ISP 351 

624 

240 

240 

624 

ISP 501 

924 

240 

240 

924 

ISP 651 

1224 

240 

240 

1224 

ISP 851 

1524  A1/2=762 

240 

240 

1524 

B2/2=762 

A1 

B1 

A2 

B2 

Fig: 1 

Fig: 2 

Detail view 

A1/2 

 

B2/2 

 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

Electrical Connection

 

The ISP heating panel is equipped with a three-wire cable for 1 / N 230 V / 50 Hz 

Color coding of conductors: 

 

Phase - brown 

Neutral  - blue 

 

Connection is made to a wall socket. 

It is always a residual current circuit breaker for use with an operating current of 30 mA maximum. If the 

supply cord of this appliance consumption is damaged, it must be replaced by the manufacturer or a 

service technician.

 

 

Operation of the ISP heating panels

 

 

It is recommended that the control of the ISP heating panels by an external room thermostat from 

TECHNOTHERM  (eg. radio receiver TPF or with the digital radio transmitter TBF. In addition, the ISP 

heating panels are equipped with a limiting thermostat to ensure their safe usage.

 

 

WARNING 

Do not install this device in areas that present an explosion hazard like a garage. Remove 
all protective coverage before turning on the device. When using the device for the first 
time you might detect a strong odor. This is no reason for concern; it is caused by residues 
of production and will disappear shortly. 

The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other 
heating device as well. Only a qualified electrician may open or remove the device from the power supply. 

 

4. Maintenance 

 

Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent. 

5. Assembly instruction 

This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual 

to any other succeeding owner of the device. 

The device is an electrical heater that was designed and intended to be mounted to walls. The device 

comes with a power plug that has to be plugged into an outlet. 

The device is designed to be connected to 230V (nominal) alternating current (AC). 

WARNING: DO NOT COVER THE HEATER 

 

 

 

 

GB 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

Technical datas of the 600 mm models 

Model 

Power 

[Watt] 

W x H x D [mm]  Weight 

Model 

Power 

[Watt] 

W x H x D [mm] 

Weight 

ISP-W 350 

300 

600x600x15 

8,7 

ISP-W 350 RF 

300 

600x600x15 

8,7 

ISP-W 450 

450 

900x600x15 

9,5 

ISP-W 450 RF 

450 

900x600x15 

9,5 

ISP-W 600 

600 

1200x600x15 

12,7 

ISP-W 600 RF 

600 

1200x600x15 

12,7 

ISP-W 750 

750 

1200x600x15 

12,7 

ISP-W 750 RF 

750 

1200x600x15 

12,7 

ISP-W 950 

950 

1500x600x15 

15,8 

ISP-W 950 RF 

950 

1500x600x15 

15,8 

ISP-W 1200 

1200 

1800x600x15 

19,1 

ISP-W 1200 RF 

1200 

1800x600x15 

19,1 

ISP-R 350 

300 

600x600x15 

8,7 

ISP-R 350 RF 

300 

600x600x15 

8,7 

ISP-R 450 

450 

900x600x15 

9,5 

ISP-R 450 RF 

450 

900x600x15 

9,5 

ISP-R 600 

600 

1200x600x15 

12,7 

ISP-R 600 RF 

600 

1200x600x15 

12,7 

ISP-R 750 

750 

1200x600x15 

12,7 

ISP-R 750 RF 

750 

1200x600x15 

12,7 

ISP-R 950 

950 

1500x600x15 

15,8 

ISP-R 950 RF 

950 

1500x600x15 

15,8 

ISP-R 1200 

1200 

1800x600x15 

19,1 

ISP-R 1200 RF 

1200 

1800x600x15 

19,1 

ISP-B 350 

300 

600x600x15 

8,7 

ISP-B 350 RF 

300 

600x600x15 

8,7 

ISP-B 450 

450 

900x600x15 

9,5 

ISP-B 450 RF 

450 

900x600x15 

9,5 

ISP-B 600 

600 

1200x 600x15 

12,7 

ISP-B 600 RF 

600 

1200x600x15 

12,7 

ISP-B 750 

750 

1200x600x15 

12,7 

ISP-B 750 RF 

750 

1200x600x15 

12,7 

ISP-B 950 

950 

1500x600x15 

15,8 

ISP-B 950 RF 

950 

1500x600x15 

15,8 

ISP-W 1200 

1200 

1800x600x15 

19,1 

ISP-W 1200 RF 

1200 

1800c600x15 

19,1 

ISP-Motiv 450 

450 

900x600x15 

9,5 

ISP-Motiv 450 RF 

450 

900x600x15 

9,5 

ISP-Motiv 750 

750 

1200x600x15 

12,7 

ISP-Motiv 750 RF 

750 

1200x600x15 

12,7 

ISP-Motiv 950 

950 

1500x600x15 

15,8 

ISP-Motiv 950 RF 

950 

1500x600x15 

15,8 

RF

“: Units are supplied with preassembled radio receiver 

Model 

Power 

[Watt] 

W x H x D [mm]  Weight 

Model 

Power 

[Watt] 

W x H x D [mm] 

Weight 

ISP-W 351 

350 

900x400x15 

8,7 

ISP-W 351 RF 

350 

900x 400x15 

8,7 

ISP-W 501 

500 

1200x400x15 

11,6 

ISP-W 501 RF 

500 

1200x400x15 

11,6 

ISP-W 651 

650 

1500x400x15 

14,5 

ISP-W 650 RF 

650 

1500x400x15 

14,5 

ISP-W 851 

850 

1800x400x15 

17,4 

ISP-W 851 RF 

850 

1800x400x15 

17,4 

ISP-R 351 

350 

900x400x15 

8,7 

ISP-R 351 RF 

350 

900x 400x15 

8,7 

ISP-R 501 

500 

1200x400x15 

11,6 

ISP-R 501 RF 

500 

1200x400x15 

11,6 

ISP-R 651 

650 

1500x400x15 

14,5 

ISP-R 650 RF 

650 

1500x400x15 

14,5 

ISP-R 851 

850 

1800x400x15 

17,4 

ISP-R 851 RF 

850 

1800x400x15 

17,4 

ISP-B 351 

350 

900x400x15 

8,7 

ISP-B 351 RF 

350 

900x 400x15 

8,7 

ISP-B 501 

500 

1200x400x15 

11,6 

ISP-B 501 RF 

500 

1200x400x15 

11,6 

ISP-B 651 

650 

1500x400x15 

14,5 

ISP-B 650 RF 

650 

1500x400x15 

14,5 

ISP-B 851 

850 

1800x400x15 

17,4 

ISP-B 851 RF 

850 

1800x400x15 

17,4 

 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

Connecting the recipient (only with the "RH" models) 

Press on the  receiver for more  than 3 seconds  the button  until the 

indicator light begins to flash. Then attach the transmitter in configuration 

mode (see manual transmitter). If the indicator light on the receiver stops 

flashing, the two products are assigned. 

Disconnect the receiver 

To delete all associated products you press the receiver button for about 

30 seconds until the indicator light flashes briefly. All channels are now 

deleted! 

Technical data’s oft the receiver „RF“ 

• power supply 230 V, 50 Hz +/-10%  

• protection class II  

• consumption: 0,5 V  

• switching capacity max.: 16 A 230 V

eff

 Cos

 

φ

 = 1  

• radio frequency 868 MHz (Norm EN 300 220),  

• radio range up to 300 m (outdoor), indoor up to 30 m, depending of structural factors and 

electromagnetic interference. 

• maximum number of recipients: 8 units 

• temperature range: -5°C to +50°C  

• dimensions: 120 x 54 x 25 mm  

• IP 44 - IK 04  

 

Switching from X3D to X2D and vice versa: 

X2D for TPF/TBF 
X3D for TPF-Eco 

1)

 

Before the changeover, the assignment to the thermostat must be cleared. 

Press and hold for 30 seconds (1): 

after 3 seconds, the LED flashes slowly. 

after 7 seconds, the LED flashes quickly. Keep the receiver button pressed until both 

LEDs flash.  

Release the button (2). 

 

 

 

 

 

 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

 

2)

 

Changeover 

When switching on the installation (1), you have 4

 

seconds to press 3 times the receiver 

button (2). The LED flashes (3): 2 times for X2D, 3 times for X3D. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GB 

 


background image

 

 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

6. Regulation 

 

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of 

the Ecodesign requirements 2015/1188. 

The installation and commissioning of the devices is only permitted in conjunction with external 

room temperature controllers that fulfill the following functions: 

 

  electronic room temperature control plus week timer 

 

and has at least one of the following properties: 

 

  room temperature control, with presence detection 

  room temperature control, with open window detection 

  with distance control option 

  with adaptive start control 

  with working time limitation 

  with black bulb sensor 

 

The following room temperature controller systems 

 

  RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-

Interface (Art.Nr.750 000 640) or 

 

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

 

  electronic room temperature control plus week timer (RF) 

  with distance control option (RF) 

 

 

Use of the ISP Standard range (without external thermostat control) is not permitted 

 

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page. 

 

Failure to comply with these requirements will result in the loss of the CE mark. 

 

 

 


background image

 

 

10 

 

Edition: 12/17

 

 

Manual  ISP W / R / B / Motive- frameless 

 

 

Model: ISP RF  (These devices may only be used with a corresponding approved thermostat - e.g. TPF-Eco and the ECO interface) 

Item 

Symbol 

 

 

 

 

Value 

 

 

 

Value 

 

Item

 

Value 

 

Heat output 

Type of heat input, for electric storage local space heaters only (select 

one) 

Nominal heat 

output 

Pnom

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

manual heat charge control, with integrated thermostat 

No 

Minimum 

heat 

output 

(indicative) 

Pmin

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

manual heat charge control with room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous 

heat output 

Pmax,c

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

electronic heat charge control with room and/or outdoor 
temperature feedback 

No 

Auxiliary 

electricity 

consumptio

 

 

 

 

 

 

 

 

 

 

 

fan assisted heat output 

No 

At nominal 

heat 

output 

elmax

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

Type of heat output/room temperature control (select 
one) 

At minimum 

heat 

output 

elmin

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

single stage heat output and no room temperature control 

No 

In standby 

mode 

elSB

 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

<0,5 

Watt 

 

Two or more manual stages, no room temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with mechanic thermostat room temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with electronic room temperature control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control plus day timer 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control plus week timer 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

Other control options (multiple selections possible) 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with presence detection 

No 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with open window detection 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with distance control option 

Yes 

 

 

 

 

 

 

 

 

 

 

 

 

with adaptive start control 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with working time limitation 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with black bulb sensor 

No 

Model: ISP   (These devices may only be used with a corresponding approved thermostat - e.g. TPF-Eco, the RF receiver and the ECO interface) 

Item 

Symbol 

 

 

 

 

Value 

 

 

 

Value 

 

Item

 

Value 

 

Heat output 

Type of heat input, for electric storage local space heaters only (select 

one) 

Nominal heat 

output 

P

nom

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

manual heat charge control, with integrated thermostat

 

No 

Minimum 

heat 

output 

(indicative) 

P

min

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

manual heat charge control with room and/or outdoor temperature 

feedback 

No 

Maximum 

continuous 

heat output 

P

max,c

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

electronic heat charge control with room and/or outdoor 
temperature feedback

 

No 

Auxiliary 

electricity 

consumptio

 

 

 

 

 

 

 

 

 

 

 

fan assisted heat output

 

No 

At nominal 

heat 

output 

el

max

 

350 

450 

500 

600 

650 

750 

950 

1200 

Watt 

 

Type of heat output/room temperature control (select 
one)

 

At minimum 

heat 

output 

el

min

 

<0,5 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

Watt 

 

single stage heat output and no room temperature control

 

No 

In standby 

mode 

el

SB

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

<0,5

 

Watt 

 

Two or more manual stages, no room temperature control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with mechanic thermostat room temperature control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with electronic room temperature control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control plus day timer

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

electronic room temperature control plus week timer

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

Other control options (multiple selections possible)

 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with presence detection

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

room temperature control, with open window detection

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with distance control option

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with adaptive start control

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with working time limitation

 

No 

 

 

 

 

 

 

 

 

 

 

 

 

with black bulb sensor

 

No 

Contact 

details: 

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt 

 

 

Lucht LHZ Elektroheizung GmbH & Co. KG 

 

Reinhard-Schmidt-Str. 1 

 

09217 Burgstädt 

 

Fon: 03724 66869 0 

 

Fax: 03724 66869 20 

 

E-mail: 

info@technotherm.de

 

 

web: www.technotherm.de 

TECHNOTHERM support: 

Fon: +49 (0) 911-93 78 32 10