PDF User Manual

  1. Home
  2. Manuals
  3. Technosystem SAU125 Operational Manual

Technosystem SAU125 Operational Manual

Made by: Technosystem
Type: Operational Manual
Category: Amplifier
Pages: 12
Size: 0.36 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

SAU125 

 

 

 

 

 

SAU125 

250W SOLID STATE UHF  

TV AMPLIFIER 

 

P/N A.002526.01.04

 

OPERATIONAL   MANUAL 

 

 

Copia n°  

 
________ 

Copy  n° 

 

Emessa il 
 
Delivered 

 
________ 

.

 

 

 

 PLANT: VIA B. PONTECORVO 10 
 SETTEVILLE DI GUIDONIA 00012 (ROMA) 
 PHONE (+39) 07743521 
 FAX (+39) 0774356136 
 E-Mail : 

technosystem@technosystem.it

 

 E-Mail 

c.service@technosystem.it

 

 WEB : http: 

www.technosystem.it

 

 

 


background image

 

 

 

SAU125 

 

 

INDEX 

 

  Description 

       

 

 

 

 

 

 

Page 

 

1.     INSTALLATION AND SET-UP …………………………………1 

        1.1       Mounting Procedure

 

…..…………………………………….1

 

        1.2       Set-up Procedure

 

…………..………………………………..2 

                    

1.2.1        Initial Tests………………………………..…………..2 

2.     OPERATION…..…………………………………………………..4 

                    

2.1       Front Panel…………………………………………………..4 

                                

2.1.1       SAU125  Display Menu…….…………………………6 

                    2.2        Rear Panel…………………………………………………..9 

                    

 

 

 

 

 


background image

 

 

 

SAU125 

 

LIST OF FIGURE 

 

Description 

       Page 

 

FIG. 1.1-1  -  SAU125 UHF TV AMPLIFIER – REAR PANEL …………………………….1 
 
FIG. 1.2.1-1  INITIAL TEST SET-UP…………………………………………………………3

 

 
FIG. 2.1-1  SAU125 – FRONT PANEL CONTROLS & DISPLAYS……………….……….4 
 
FIG. 2.1.1-1  SAU125 250W UHF AMPLIFIER OPERATION DISPLAY…………………6 
 
FIG. 2.2-1  SAU125 – REAR PANEL CONTROLS & DISPLAYS………………………....9

 

 

 

 

 

 

 


background image

 

 

 

SAU125 

 

1. 

INSTALLATION AND SET-UP 

The SAU125 250W Solid State UHF TV Amplifier is composed of a 3U drawer 
which can be mounted on a 19” standard rack. 

1.1  

Mounting Procedure 

-

 

Insert the drawer in its place on the rack and fix it with four rack screws. 

-

 

Connect the 220V (110V), 50/60Hz supply to the power plug located on the rear panel (Fig. 
7.1, ref. 1). 

-

 

Connect the RF Input connector located on the rear panel ( Fig. 7.1 ref. 2) to the RF cable 
coming from 5W RF Amplifier (exciter). 

-

 

Connect the RF OUT connector located on the rear panel (Fig. 7.1 ref. 3) to the successive 
High Power RF Amplifier input, or the antenna system. 

 

 

 

 

 

 

FIG. 1.1-1  -  SAU125 UHF TV AMPLIFIER – REAR PANEL  

 

 

 

 


background image

 

 

 

SAU125 

 

1.2                  Set-up Procedure 

In this paragraph are described the tests and alignments to be performed on the 
SAU125. For this purpose, the following instruments are necessary: 

-

 

Spectrum analyzer, 0.1 to 1000 MHz with tracking generator TEK 2712 or 
equivalent.  

-

 

30dB –300W attenuator, BIRD 300A FFN 30 or equivalent. 

Should any malfunction be detected, refer to chapter 6 for the specific 
troubleshooting procedures. 

 

1.2.1   Initial Tests 

Once the procedure described in paragraph 7.1 has been carried out, perform the 
following operations: 

a)

 

Perform set-up as shown in Fig. 3.2 and turn-on the SAU125 by moving 
the ON/OFF switch of the front panel (Fig. 4.1 ref. 1) to ON position and 
verify that the display goes ON (Fig. 4.1 ref. 6). 

b)

 

Preset the spectrum analyzer to the frequency band in accordance to the 
selected TV channel. 

c)

 

Check that the SAU125 GAIN is  

 13dB. (Small signal) 

d)

 

Turn OFF the equipment, and remove the measurement set-up. 

 


background image

 

 

 

SAU125 

 

 

 

 

 

 

 

 

FIG. 1.2.1-1  INITIAL TEST SET-UP 

SAU125 

 


background image

 

 

SAU125 

 

2.                   OPERATION 

This chapter contains the description of the Controls and Indicators of the front 
and rear panels of the SAU125 250W UHF TV Amplifier and their instruction for 
use. 

 

2.1  

 

Front Panel 

 

 

 

 

 

 

 

 

 

 

FIG. 2.1-1  SAU125 – FRONT PANEL CONTROLS & DISPLAYS 

 

 

 

 


background image

 

 

SAU125 

 

 

 

CONTROLS & 

DISPLAYS 

DESCRIPTION 

FIG. 2-1 

 

SWITCH ON/OFF 

 

Two position switch when in 
ON enables the a.c. voltage to 
P.S. input. 

Ref. 1 

REGULAR (Green Led)  Regular LED 

Ref. 2 

ENABLE (Yellow Led) 

Enable Contact 

Ref. 3 

FAILURE (Red Led) 

General Failure 

Ref. 4 

DISPLAY 

Seven segment display for the 
display of the measured 
parameters and Error codes 

Ref. 6 

UP 

Push button for the selection of 
the parameter to be measured 
and  displayed 

Ref. 6 

ENTER 

Push button for the selection of 
the parameter to be measured 
and  displayed 

 

Ref. 7 

 

DOWN 

Push button for the selection of 
the parameter to be measured 
and  displayed 

Ref. 8 

 

 

 

 

 

 

 

 

 


background image

 

 

SAU125 

 

2.1.1

 

  SAU125  DISPLAY   MENU 

 

AFTER 3 SEC.

LD MOS POWER AMPLIFIER

OPERATING DISPLAY

SWITCH ON

FAILURE

ENABLE

REGULAR

FIRMWARE   REVXXX

250W POWER UNIT

DOWN

ENTER

UP

DD MM YY     TYPE

UP

FAILURE

REGULAR

ENABLE

DOWN

ENTER

UP

V1: 0.0V  

08/11/07 14:57 250W

Temp. (^C) :25

08/11/07 14:57 250W

STATUS  :[OFF] 

ACTIVE ALARMS

UP

ENABLE

OPERATING DISPLAY

FAILURE

OPERATING DISPLAY

REGULAR

UP

UP

OPERATING DISPLAY

ENABLE

FAILURE

REGULAR

REGULAR

FAILURE

ENABLE

ENTER

DOWN

UP

[OK]

ENTER

DOWN

UP

DOWN

ENTER

ENTER

ENABLE

UP

REFPWR  0W  AMP1

STATUS  :[OFF] 

PA1: 0.0A  

08/11/07 14:57 250W

UP

OPERATING DISPLAY

UP

ENABLE

FAILURE

REGULAR

OPERATING DISPLAY

FAILURE

UP

[OK]

ENTER

DOWN

UP

DOWN

08/11/07 14:57 250W
STATUS  :[OFF] 

ON AIR TIMER: 999999

08/11/07 14:57 250W
FWDPWR  0W  AMP1

OPERATING DISPLAY

REGULAR

OPERATING DISPLAY

ENABLE

FAILURE

REGULAR

[OK]

UP

ENTER

DOWN

UP

 

 
 
 

FIG. 2.1.1-1  SAU125 250W UHF AMPLIFIER 

OPERATION DISPLAY 

 
 

 
 
 
 

 


background image

 

 

SAU125 

 

 

 
The upper part of the display shows always the date, 
the hour and the direct power. The status line shows the 
condition of the amplifier “OFF” or “ON” and “OK” or 
“NOT” for the indication of enable. Last line shows the 
time of operation. 

 
 
 

Second line for direct power of the indicated amplifier. 
Third line for reflected power. 
 
 
 

 
 
 

Second line for the control of the current of the RF 
pallet. 
 
 
 

 
 
 

 
Second line shows the voltage of the P.S. 
 
 
 
 

 
 

 
Second line we have the indication of the temperature 
of the heat synk. 
 
 
 

 

08/11/07 14:57 250W
STATUS  :[OFF] 

ON AIR TIMER: 999999

OPERATING DISPLAY

ENABLE

FAILURE

REGULAR

[OK]

ENTER

DOWN

UP

ENTER

ENABLE

REFPWR  0W  AMP1

STATUS  :[OFF] 

FAILURE

[OK]

DOWN

08/11/07 14:57 250W
FWDPWR  0W  AMP1

OPERATING DISPLAY

REGULAR

UP

PA1: 0.0A  

08/11/07 14:57 250W

ENABLE

FAILURE

REGULAR

OPERATING DISPLAY

ENTER

DOWN

UP

V1: 0.0V  

08/11/07 14:57 250W

REGULAR

FAILURE

ENABLE

DOWN

ENTER

OPERATING DISPLAY

UP

Temp. (^C) :25

08/11/07 14:57 250W

STATUS  :[OFF] 

OPERATING DISPLAY

ENABLE

FAILURE

REGULAR

[OK]

ENTER

DOWN

UP

 


background image

 

 

SAU125 

 

 
 

 
3 Alarms in 1 minute will cause blocking of the 
machine. 
This display shows the different active alarms. 
Reset active alarms, press UP and DOWN for 5 sec. 
 

 
 
 

 
This display shows the data logger alarms 
DD= Day  MM= Mounth  YY= Year 
Reset alarms, press UP, DOWN and ENTER  
For 5 sec. 
 

 
 
 
 
 
 
 

 

 

ACTIVE ALARMS

ENABLE

FAILURE

OPERATING DISPLAY

REGULAR

ENTER

DOWN

UP

DD MM YY     TYPE

FAILURE

REGULAR

ENABLE

DOWN

ENTER

UP

OPERATING DISPLAY

 


background image

 

 

SAU125 

 

2.2  

REAR 

PANEL 

 

 

 

 

 

 

 

 

 

 

FIG. 2.2-1  SAU125 – REAR PANEL CONTROLS & DISPLAYS 

 
 

  

 

 

 

 

 

 

 

 

 

 

CONTROLS  

DESCRIPTION 

FIG. 4.1 

 

RF IN  

N Type connector used for 
connection of RF input signal 

 

Ref. 1 

 

RF OUT 

N Type connector used for 
connection of RF output signal 

 

Ref. 2 

CONNECTOR 

INTERFACE 

Parallel I/O Vac Line and 
RS232/422 connectors 

 

Ref. 3 

 

POWER INLET, FUSE 

Connector for 110/220V  
60/50Hz main supply line input 
and main supply fuse 

 

Ref. 4