PDF User Manual

  1. Home
  2. Manuals
  3. Technoline WS9132 Manual

Technoline WS9132 Manual

Made by: Technoline
Type: Manual
Category: Weather Station
Pages: 13
Size: 2.00 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

WS9132 Manual 

Environmental reception effects 

The station obtains the accurate time with wireless technology. Same 

as all wireless devices, the reception is maybe affected by the 

following circumstances: 

 

long transmitting distance   

 

nearby mountains and valleys 

 

near freeway, railway, airports, high voltage cable etc.   

 

near construction site 

 

among tall buildings 

 

inside concrete buildings 

 

near electrical 

appliances (computers, TV’s, etc) and metallic 

structures 

 

inside moving vehicles 

Place the station at a location with optimal signal, i.e. close to a 

window and away from metal surfaces or electrical appliances. 

 

Precautions 

 

This main unit is intended to be used only indoors. 

 

Do not subject the unit to excessive force or shock. 

 

Do not expose the unit to extreme temperatures, direct sunlight, 
dust or humidity. 

 

Do not immerse in water. 

 

Avoid contact with any corrosive materials.     

 

Do not dispose this unit in a fire as it may explode. 

 

Do not open the inner back case or tamper with any components 
of this unit. 

 

Batteries safety warnings 

 

Use only alkaline batteries, not rechargeable batteries. 

 

Install batteries correctly by matching the polarities (+/-). 

 

Always replace a complete set of batteries. 

 

Never mix used and new batteries. 

 

Remove exhausted batteries immediately. 

 

Remove batteries when not in use. 

 

Do not recharge and do not dispose of batteries in fire as the 
batteries may explode. 

 


background image

WS9132 Manual 

 

Ensure batteries are stored away from metal objects as contact 
may cause a short circuit. 

 

Avoid exposing batteries to extreme temperature or humidity or 
direct sunlight. 

 

Keep all batteries out of reach from children. They are a choking 
hazard. 

 

Use the product only for its intended purpose! 

 

Consideration of duty according to the battery law 

Old  batteries  do  not  belong  to  domestic waste  because 
they  could  cause  damages  of  health  and  environment. 
You  can  return  used  batteries  free  of  charge  to  your 

dealer and collection points. As end-user you are committed by 
law  to  bring  back  needed  batteries  to  distributors  and  other 
collecting points! 
 
Consideration of duty according to the law of electrical devices 

This  symbol  means  that  you  must  dispose  of  electrical 
devices  separated  from  the  General  household  waste 
when it reaches the end of its useful life. Take your unit 
to  your  local  waste  collection  point  or  recycling  centre. 

This applies to all countries of the European Union, and to other 
European countries with a separate waste collection system. 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

WS9132 Manual 

Features

 DCF Radio controlled time function 

 12/24 hour format 

 Daily Alarm Function 

 Snooze function (OFF or 1~60min) 

 Low battery indicator 

 Maximum /minimum value record of temperature and humidity 

 Temperature in °C or °F   

 Outdoor thermometer ice alert 

 Humidity measurable range: 20%RH ~ 95%RH 

 Temperature: 

 

— Indoor temperature measurement ranges: -9.9°C (14.2°F) ~ 

50°C (122°F)   

— Outdoor temperature measurement ranges: -25°C (-13°F) ~ 

50°C (122°F) 

 Remote Sensor: 

— Wall Mount or Table Stand   

— 3 Channels selectable 

— 433.92MHz RF transmitting frequency   

— 30 meter transmission range in an open area 

 Weather forecasting function 

 Power Supply:   

Weather Station: 

Battery: 2 x LR03 AAA 

     

Remote Sensor:   

Battery: 2 x LR06 AA

 

 

 

 


background image

WS9132 Manual 

Weather Station Appearance 

 

 

 

 

 

 

 


background image

WS9132 Manual 

Part A 

– Weather station 

 

                    A1: Time 

A2: Indoor temperature and humidity 

A3: Ice alert icon                                                                                                                                       

                    A4: Radio Controlled Icon                                                                           

                    A5: DST icon                                                                                                                               

A6: Weather forecast pattern                                                                                                                     

A7: Outdoor temperature                                                     

A8: Operation buttons 

A9: Stand cover 

A10: Battery door                                                   

Part B 

– Remote sensor 

                   

B1: Transmit indicate LED                               

  B2: Battery door                                                   

  B3: Channel switch                                                     

B4: Reset button 

                       

Initial operation: 

 Open the Weather Station battery compartment cover   

 Insert 2 x A

AA batteries observing polarity [ “+” and “ –“ marks]   

 When you insert the batteries, all icons on the LCD display will light 

up for 3 seconds, you will hear a beep tone and the station detects 

indoor temperature & humidity. 

  The  Weather  Station  will  now  start  to  make  a  connection  to  the 

outdoor remote sensor. This operation takes about 3  minutes and 

is  displayed  by  a  flashing  reception  RF  antenna  symbol  in  the 

“OUTDOOR” display area on the receiver. 

 Open Wireless Outdoor Sensor battery compartment cover, Insert 2 

x AA batteries observing polarity [ “+” and “–“ marks]. 

 


background image

WS9132 Manual 

 After receiver has created a connection to the outdoor remote 

sensor, After 3 minutes it will enter the Radio control time receive 

mode. 

 

Reception of the DCF signal: 

 The clock will automatically search the 

DCF 

(radio controlled time) 

signal  after  3  minutes  of  any  restart  or  changing  of  new  fresh 

batteries. The radio mast icon starts to flash. 

  At  1:00  /2:00  /  3:00  am,  the  clock  automatically  carries  out  the 

synchronization  procedure  with  the 

DCF

  signal  to  correct  any 

deviations  to  the  exact  time.  If  the  synchronization  attempt  is 

unsuccessful (the radio mast icon disappears from the display), the 

system  will  automatically  attempt  another  synchronization  at  the 

next  full  one  hour.  This  procedure  is  repeated  automatically  up  to 

total 5 times. 

 To start manual 

DCF

 signal reception, press and hold 

the “ 

 

” 

button for 3 seconds. If no signals received within 7 minutes, then the 

DCF

  signal  search  stops  (the  radio  mast  icon  disappears)  and  start 

again at the next full one hour.   

 During RC reception

to stop searching radio signal, press the 

” 

button once. 

Please note: 

  A flashing radio mast icon indicates that the 

DCF

 signal reception 

has started 

  A  continuously  displayed  radio  mast  icon  indicates  that  the 

DCF

 

signal was received successfully 

 We recommend a minimum distance of 2.5 meters to all sources of 

 


background image

WS9132 Manual 

interference, such as televisions or computer monitors 

  Radio  reception  is  weaker  in  rooms  with  concrete  walls  (e.g.:  in 

cellars)  and  in  offices.  In  such  extreme  circumstances,  place  the 

system close to the window. 

  During  the  DCF  reception  mode, only the 

” button has  a 

function, other  buttons  are  not  functional,

 

If  you  want  to carry  out 

other  functions of  operation, please  press 

” button to exit  the 

DCF receiving mode. 

 

Manual settings: 

 Press and hold 

the “

”, 12/24HR start to flash. Now use “

+

” and 

-

” buttons to set the set 12 or 24 hour mode. 

 

Press the “

 button to confirm your setting. The time zone start 

to flash. 

Now use “

+

” and “

-

” buttons set a    time zone (-12 to +12). 

For example for UK, the time zone is -01, for Germany it is 00. 

 

Press  the  “

  button  to  confirm  your  setting,  the  Hour  display 

starts to flash. Now use “

+

” and “

-

” buttons to set the hour. 

 

Press the “

 button to confirm your setting, the Minute display 

starts to flash. Now use “

+

” and “

-

” buttons to set the minute. 

 

Press  the  “

  button  to  confirm  your  setting,  the  temperature 

unit  starts  to  flash. 

Now  use  “

+

”  and  “

-

”  buttons  to  choose 

between °C or °F temperature unit. 

 

Press  the  “

  button  to  confirm  your  setting,  the  barometric 

pressure unit starts to flash, Now use “

+

” and “

-

” buttons to set the 

barometric pressure unit in mB/hPa or inHg. 

 

Press  the  “

  button  to  confirm  your  setting,  the  barometric 

pressure data starts to flash. Now use “

+

” and “

-

” buttons to set the 

 


background image

WS9132 Manual 

barometric  pressure  data  according  to  the  local  relative  air 

pressure. 

If not changed, the value corresponds to the absolute air pressure. 

 

Press  the  “

  button  to  confirm  your  setting,  the  weather 

forecast pattern start

s to flash. Now use “

+

” and “

-

” buttons to set 

the weather forecast pattern according to the current weather.. 

 

Press  the  “

  button  to  confirm  your  setting  and  to  end  the 

setting procedures, the display will return to the normal mode. 

Please note: 

  If  there  is  no  valid  operation  within  20  seconds,  the  station  will 

automatically return to normal time mode from the set mode. 

 

Setting the alarm: 

 

Press  “

” 

button  once,  LCD  displays 

the  “

”  icon,  the  alarm 

function  is  ON. 

Then  press  “

” 

button  once

,  the  “

”  icon  will 

disappears from the display, the alarm function is OFF. 

 

Press once “

” button, LCD display alarm time, then press and 

hold “

” button for 3 seconds until the hour of alarm time starts 

to flash

. Use the “+” and “-” buttons to set the hour.   

 

Press “

 button to confirm your setting. The minute of the alarm 

time starts to flash. Use the 

+

” and “

-

” buttons to set the minute.   

 

Press “

 button to confirm your setting. The snooze time starts 

to  flash.  Use  the  “

+

”  and  “

-

”  buttons  to  set  the  snooze  time.  The 

snooze time can be set from OFF to 60 minutes. 

 

Press “

 button to confirm your setting and to end the setting 

procedure. 

 

 


background image

WS9132 Manual 

Please note:   

  If  there  is  no  valid  operation  within  20  seconds,  the  station  will 

automatically  return  to  normal  time mode  from  the  alarm  time  set 

mode. 

  The  alarm  will  sound  for  2  minutes  if  you  do  not  deactivate  it  by 

pressing  any  button.  In  this  case  the  alarm  will  be  repeated 

automatically after 24 hours. 

  Rising  alarm  sound  (crescendo,  duration:  2  minutes)  changes  the 

volume 4 times whilst the alarm signal is heard. 

 

Switching off the alarm signal 

 

Press any button except the “SNOOZE/LIGHT” button to stop the 

alarm signal. It is  not  necessary  to reactivate the  alarm. It switches 

itself automatically to the alarm time which has already been set. 

 

Snooze function 

 When the alarm is ringing, press 

the “

SNZ

” button the alarm mode 

to get to snooze mode. The alarm signal sounds again after already 

been  set.  If  OFF  was  selected  in  the  SNOOZE  time  setting,  the 

alarm will not repeat. 

 

RF Transmission Procedure: 

 The weather station automatically starts receiving transmission 

from outdoor thermo sensor after batteries inserted.   

 The remote sensor will automatically transmit temperature signal to 

the Weather Station after batteries inserted.   

 


background image

WS9132 Manual 

 If the Weather Station failed to receive transmission from outdoor 

sensor (“

- -.-

”display on the LCD), press and hold the

 

“CH”

 button 

for 3 seconds to receive transmission manually. RF icon “

” 

flashes on the LCDof the Weather Station to receive the remote 

sensor.   

 

If the weather station is used with 2 or 3 transmitters, press “+/CH” 

button shortly to display CH2, CH3 or cyclic display. 

P re ss "+ /C H "

P re ss "+ /C H "

P re ss "+ /C H "

P re ss "+ /C H "

A u to m a tic

A u to m a tic

A u to m a tic

5 S

5 S

 

Maximum/minimum temperature/humidity   

 Press 

MEM

” button once, the LCD will display maximum value of 

temperature/  humidity.  If  the 

“MEM”  button  is  pressed  again  the 

minimum value is displayed.

 

 

While displaying MAX or MIN values, there is “MAX” or “MIN” on the 

LCD. 

 

Press  and  hold  “MEM”  button  for  3  seconds.  The 

temperature/humidity  maximum/minimum  value  will  reset  to  the 

current values

 

 

Please note: 

 


background image

WS9132 Manual 

  If  the  temperature  reading  is  below  ranges,  the 

LL.L

  will  be 

displayed. If the temperature reading is above ranges, the 

HH.H

 will 

be displayed. 

 

Trend displaying 

 

The current temperature/humidity/barometric pressure and the 

temperature/humidity/barometric pressure trend are shown in the 

LCD display. 

 

After successfully connecting with the outdoor sensor, the weather 

station can display the outdoor temperature and the indoor 

temperature/humidity trend.     

 

You may see the following displays: 

    The temperature/humidity/ barometric 

pressure is rising. 

    The temperature/humidity/ barometric 

pressure is steady. 

    The temperature/humidity/ barometric 

pressure is falling. 

 

Ice alert 

  The  ice  alert  symbol  appears  and  flashing  next  to  the  outdoor 

temperature  when  the  outdoor  temperature  at 

–1

  to  +  2.9 

  or 

+30.2

 to + 37.2

 

Weather forecasting function 

 The weather forecast is calculated from evaluation of fluctuations in 

the  barometric  pressure  and  may  deviate  from  the  actual  weather 

conditions. 

 


background image

WS9132 Manual 

 The weather station displays the following weather symbols: 

S u n n y

S lig h tly   c lo u d y

C lo u d y

R a in y

S n o w

 

 The weather symbols indicate the weather fluctuation over the next 

eight hours and not the current weather. 

 

Technical details 

Supply voltage:      2.5~3.3V 

Time zone:      -12~12Hr 

IN Temperature measuring range:      -9.9~50

/14.2~122

 

OUT Temperature measuring range:      -25~50

/-13~122

 

Temperature resolution:      0.1

/

 

Temperature accuracy: 

0

℃~

40

:    ±1

 

–25

℃~

-0

, 40

℃~

50

℃:

  ±2

 

Humidity measuring range

20-95% 

Humidity resolution

1% 

Humidity accuracy

 

40-80%:      ±5% 

20~39%,81-95%:      ±8% 

 


background image

WS9132 Manual 

RF receiving distance

      30meter (free field) 

Air pressure measuring range:      850-1100hpa 

Air pressure change accuracy:      ±5hpa