INTRODUCTION 

 

The IR to USB adapter allows the user to download the stored 
test  data  in  the  B500  into  your  computer.  Once  installed,  the 
test data is stored in a Windows based program for immediate 
printing or saved in a file for future reference.  

                      
                          

 

 

 

Plug into 

Computer USB Port 

IR Receiver 

 

User 

 Instruction Manual

 

Techno Tools 

Model B501 

IR to USB Adapter 

For use with the B500 

 Electrical System Analyzer  

 

Print and Store Test Data from your PC 

 

UTILITY MENU OPTIONS 

 

The  utility  menu  allows  the  user  to  set  up  the 

IR  Printer 

they 

will be using.  When using the B501 IR to USB Adapter always 
select the 22-22566 printer (IrDA protocol). 
 

To Select the IR Printer: 
 

Press  and  HOLD  DOWN  the 

NEXT

 

+

  button  while 

simultaneously  pressing  the  MENU/ON-OFF  button.  Scroll 
through  the  settings  by  continually  pressing  NEXT  +  until 

SETUP PRINTER

 is displayed.   

 
Press 

ENTER

.  The  default  printer  is  the  HHGA-5  (HPIr).  

IMPORTANT:

  The 22-22566 must be selected for the B501 to 

work since the B501 requires IrDA protocol. 
 
Press 

NEXT  +

  to  select  the  22-22566  printer  and  then  press 

ENTER

.

 

 

SPECIFICATIONS  

 

Infra Red Protocol: 

 

 

IrDA  

 
Normal dist. from Tester to Adapter:  

18” 

 
USB Cable: 

 

 

 

Mini USB 

 
USB cable length: 

 

 

36”    

 
Operating Temperature: 

  

 

32°F to 120°F 

   
Weight:     

                   

 

.25 LBS  

 

 

Accessory Parts 

Item 

Part Number 

USB Mini Cable 

 

Instruction Manual 

 

CD Installation Disc 

 

 

NOTE: If you receive an error message on some Vista Ultimate 

systems, follow the instructions below to disable the UAC: 

 

1. Open Administrative Tools in Control Panel  
2. Double-click on System Configuration  
3. Click Continue to accept the UAC prompt

  

4. Select the Tools tab  
5. Scroll down and select Disable UAC  
6. Click Launch  
7. Reboot your machine

 

 

 

RETURN FOR REPAIR POLICY

 

Every  effort  has  been  made  to  provide  reliable,  superior  quality 
products.    However,  in  the  event  your  instrument  requires  repair, 
forward unit to Service Center freight prepaid to the address below with 
return address, phone number and/or email address.  

SERVICE CENTER 

2651 W 81st Street 

Hialeah, FL 33016

 

 

WARRANTY POLICY

 

The B501 Battery Diagnostic Tester is warranted to be free of defects 
in materials and workmanship for a period of two years from the date 
of  purchase.    This  warranty  applies  to  all  repairable  instruments  that 
have  not  been  tampered  with  or  damaged  through  improper  use 
including unauthorized opening of the unit. Please ship warranty units 
that require repair freight prepaid to Service Center along with proof of 
purchase, return address, phone number and/or email address.  

Problems or Questions? 

Call Toll Free: 1-800-222-0956 

Figure 1

 

Align  the 

B500 with IR 

to USB 

Adapter to 

Print or Save 

to Computer 

IR Transmitter

 

 


background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

Downloading Data Using the IR to USB Adapter 

 

IMPORTANT: YOU MUST SELECT THE IRDA PRINTER (2-22566) IN 

THE UTILITY MENU BEFORE PROCEEDING. SEE PAGE 6.

 

Click start>All Programs> Techno Tools> Techno Tools Software to 
open the IR to USB Adapter program.

 

1. 

The following screen will appear: 

 
 
 
 
 

2. 

Turn  on  the  B500  by  pressing  the 

MENU/ON-OFF

  button.  To 

print, press 

NEXT +

 until the display shows 

PRINT LAST TEST

3. 

Press

  ENTER 

.  The  display  will  show  the  message 

ALIGN 

THE PRINTER.

  Align the B500 Ir transceiver located at the top 

of the tester with the adapter’s IR receiver (see figure 1). 

Note: 

The  B500  must  be  approximately  18-24  in.  or  closer  to  the

 

adapter

.  

4. 

Press  the 

ENTER

 

  button.    The  last  data  stored  in  the 

memory will begin downloading to the computer.   

 

Note:  The  alignment  between  the  tester  and  the  IR  printer  must  be 
proper for data to download to the computer. 

 

Using the IR to USB Program 

To  set  up  shop  name,  address,  and  phone  number  on  the  print  out, 
click on 

Setup. 

The following screen will appear:  

 

This information will show at the top of the print out page each time the 
data is printed and only needs to be entered once. 

 

 

 

Using the IR to USB Program Cont. 

 

When  the  data  is  recognized  by  the  IR  to  USB  program,  the 
following screen will appear: 

 

Enter the customer, technician name, car make/model, etc. Click on 
OK.  The data will automatically display in the appropriate columns.  
Note:  If  it  is  not  necessary  to  track  the  customer,  technician,  or 
other  information  on  this screen, leave  blank  and  click  OK  without 
entering their names. 

 

The data will appear as below:   

 

 
To  view  all  columns  scroll  to  the  right  using  arrow  keys  or  mouse 
wheel.

 

To  save the  data, click  on 

Save As

.    The  data  will  be saved  as  a 

.btd file.  To view the file at a later date, click on 

Load

 and select 

the file name desired.  Note: to save and view 

all

 test data stored, 

keep all test data in the same file. Each new data downloaded will 
always be added to the next row. 

Note:

 To delete any row of data- 

Click mouse to highlight and press delete key on keyboard.  
 
Otherwise, individual data can be saved as a separate file as long 
as no new data is added and saved to that file.

 

Printing the Data on your PC Printer 

 

To print the data using your PC printer, click on the row or rows 
containing  the  Data  you  wish  to print.  The  row  or  rows  will  be 
highlighted. 
Click on the PRINT button.  The data on the highlighted row(s) 
will print out on standard 81/2 x 11 size computer paper.

  

 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
NOTE

: To properly test the Electrical System (Full Test) the test 

sequence should be Battery Test, Starter Test, and then 
Charging System Test. The battery must be in good condition 
to properly test the Starter and Charging system. Therefore, the 
Starter Test Data and/or Charging Test Data may not show on 
the printout if either test is skipped.  

Installing the B501 CD  

System Requirements: 

Windows XP Service Pack 2 Minimum (Home or Ultimate) or 

Vista (Home or Ultimate) 

 

1. 

Insert the CD into your CD-Rom 

 

2. 

Follow the simple onscreen instructions.  The software will 
prompt you through each step of the installation. 

 

 

3. 

If the software does not start automatically:  

 

Click START on the Windows Taskbar 

 

Chose RUN 

 

Type  D:\setup.exe  (where  D  is  your  CD-ROM 
drive

 

 

Click OK.

 

 

Note: 

The 

software 

installation 

requires 

Microsoft 

Framework  3.5.  This  will  be  automatically  installed  if 
required.  In  this  case  installation  may  take  about  10  to  12 
minutes to install although older systems may take longer

.   

 

4. 

When  the  installation  finishes,  connect  the  IR  to  USB 
adapter  to  one  of  the  USB  ports  on  your  computer.  The 
computer  will  show  the  prompt  “Found  New  Hardware”. 
Follow  the  directions  in  the  new  hardware  Wizard  to 
complete the driver installation.

 

 

5. 

When  the  new  hardware  installation  is  complete,  double 
click  on  the  Techno  Tools  Software  program  to  open  the 
IR to USB Adapter program

.

 

 
 
 

Header information is 
entered in

 

Setup

 (see 

page 3)

 

Date and Technician  
(see page 4) 

Car information entered 
(see page 4) 

Data from battery 
tester