www.ta.co.at

 

Manual Version 1.08.1 

 

English 

 

C.M.I. 

Control and Monitoring Interface 

Software Version 1.30.2 

 
 
 
 

 

 

Quick Guide: 

Mounting and connection 

Commissioning 

 

 


background image

 

 

 

 

 

 

 


background image

 

 

Table of contents 

Manual version 1.08.1 EN 

1. Delivery scope ............................................................................................................. 4

 

2. Mounting and connection ............................................................................................ 4

 

2.1. Connections ..................................................................................................................... 4

 

2.2. Making the connections .................................................................................................. 5

 

3. IP-Address .................................................................................................................. 5

 

3.1 Network with DHCP server (standard) ............................................................................ 5

 

3.2. Network without DHCP server ........................................................................................ 5

 

3.3. Fixed IP address ............................................................................................................... 5

 

4. Access via browser ..................................................................................................... 5

 

4.1. Access via LAN or port forwarding ................................................................................. 5

 

4.2. Access via C.M.I. web portal https://cmi.ta.co.at ......................................................... 6

 

5. Resetting and loading of factory settings .................................................................... 9

 

 
 
 
 
 
 

UVR1611 compatibility information 

In order to be able to access the full range of functions, the controller must have at least 
operating system version A3.25. 

 
 
 

 

 

 


background image

 

1. Delivery scope 

The delivery scope of the device includes the following parts: 
1 pc. Control and Monitoring Interface C.M.I. 
1 pc. SD card 
1 pc. 4-pole plug for the CAN bus 
1 pc. 3-pole plug for the DL bus 
1 pc. Brief guide 
1 pc. 12V power unit (only with model: 01/CMI-NT) 
 

2. Mounting and connection 

The C.M.I. can be assembled either with 2 screws on an even surface or with the enclosed 
rapid mounting to a TS35 DIN rail according to the EN 50022 Standard. 

Dimensions:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.1. Connections 

Connections are labelled and must not be confused.  
The following Figure also shows termination on the left (CAN bus).

 

 

 
 
 
 
 
 
 
 
 
Power consumption: typically 1.5 W

Reset button on the 

rear side 

Rapid mounting to a TS35 

 

SD Card 

 


background image

 

2.2. Making the connections 

Connections must be made in the following sequence 

1. 

Connection LAN cable 

2. 

Connection CAN bus or DL bus cable 

3. 

Optional: power supply with power unit 
(positive pole on the internal conductor, earth outside) 

The 

POWER

 LED now has to be 

green permanently

 

3. IP-Address 

Access requires an IP address.

 

3.1 Network with DHCP server (standard) 

The network settings are determined 

automatically

3.2. Network without DHCP server 

Direct C.M.I. connection

 Windows PC 

DHCP must be activated on the PC.PC and C.M.I. automatically gets an IP address this way. 
This process can take more than 1 minute. 

3.3. Fixed IP address 

1. 

Create a 

Text file

 called 

fix_ip.txt

 with the required IP address and UTF-8 encoding in 

the root directory of the SD card. The content of this file must be only an IP address 
(example: 192.168.0.10) and "Enter". 

2. 

Insert 

the SD card in the C.M.I. 

3. 

During the next start,

 the C.M.I. adopts this IP address and deletes the txt file on the 

SD card. 

The network settings must then be configured locally (C.M.I. menu Settings/Ethernet). 

The 

LAN

 LED now has to 

flash green or be green permanently

 

4. Access via browser 

4.1. Access via LAN or port forwarding 

1. 

Browser 

start 

2. 

Entry in the address field

 of the browser: 

cmi

 (factory setting, only under Windows) or 

IP address

 

 
 
 
 
 

                 

Entry "cmi“

                           Entry IP address (example) 

The language in this window depends on the language setting in the PC operating system. 

 

 


background image

 

3. 

 Authentication

: Entry user name and password 

 

The 

factory-set

  predefined 

user  name  is 

admin

,  the 

password also 

admin

.  

Confirmation with "

OK

".  

The  language  in  this  win-
dow  depends  on  the  lan-
guage  setting  in  the  PC 
operating system. 

 

4. 

Now the 

menu

 of the C.M.I. appears already. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
The  additional  operation  is  described  in  the  online  help     

(

help.ta.co.at

).

 

 

 

4.2. Access via C.M.I. web portal 

https://cmi.ta.co.at

 

If you want access via

 Internet

, then 

the C.M.I can be connected via “„

C.M.I. web portal

“. The 

C.M.I. web portal is a server that was set up by Technische Alternative. 

1. 

Select the address 

https://cmi.ta.co.at

 and click 

Log in

” and “

Registration

“.

 

 

 
 
 
 
 
 
 
 
 
 

 

 

 


background image

 

2. 

Completing

 the registration form and accepting the terms of use 

3. 

After completing registration, an e-mail with an activation link will be sent to the e-mail 
address used for registration. This process can take up to 30 minutes. 

4. 

After clicking the link, the 

start page

 of the web portal is displayed already. 

 
 
 
 
 
 
 
 
 
 
 
 
 

5. 

Adding 

the C.M.I. in the Web portal 

Selection of the tab “

C.M.I.s

 

6. 

Selection “

Add C.M.I.

 

 
 
 
 
 
 
 
 
 
 

 

 

 


background image

 

7. 

Entry of C.M.I. data 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

On the rear of the device is the 

serial number

 on the rating plate and the 

key

 on the 

key label. The key must be entered 

without spaces

 
 
 
 
 

Caution

 All warranty and guarantee claims become void if the rating plate or key label 

is removed! 
 
The "

Designation

“ helps with the selection of several individual C.M.I.s and is visible in 

the list of individual C.M.I.s. If service by the 

super user

 (e.g. Technische Alternative) 

is to be allowed at 

all times

, the appropriate field will be checked. 

 

 

 


background image

 

8. 

After u

pdating the page, the C.M.I. appears in the list “

My C.M.I.s

“.

 

 
 
 
 
 
 
 
 
 
 
 
 

    Clicking on the serial number takes you to the C.M.I. menu. 

The  additional  operation  is  described  in  the  online  help         (

help.ta.co.at

). 

 

5. Resetting and loading of factory settings 

Briefly

 pressing the reset key on the rear of the C.M.I. restarts the C.M.I. (reset). 

The C.M.I. can also be restarted (reset) by unplugging the CAN bus connection and plugging 
it back in. 
If the reset button is pressed and released while the red LEDs are still illuminated, resets the 
C.M.I. to factory settings.  

Caution: 

Pressing the reset button until the red LEDs stop being illuminated starts a firmware 

update  with  the  C.M.I.  operation  system  saved  to  the  SD  card.  Up  to  boot  sector  1.04,  the 
current firmware in the "UPDATE" folder of the SD card must be called "

CMI.BIN

". From boot 

sector 1.05 onwards, it must be called "

FIRMWARE.cmi

". You can identify whether the boot 

sector is 1.05 or above by 4 red LEDs, which begin to glow faintly when the device is started. 
 
 
 
 
We reserve the right to make technical changes.                            

  © 

2018 

 

 


background image

 

 

EU Declaration of conformity

 

Document- Nr. / Date: 

TA17021 / 02/02/2017 

Company / Manufacturer:  Technische Alternative RT GmbH 
Address: 

A- 3872 Amaliendorf, Langestraße 124 

This declaration of conformity is issued under the sole responsibility of the manufacturer. 

Product name: 

C.M.I. 

Product brand: 

Technische Alternative RT GmbH 

Product description: 

Control and Monitoring Interface 

The object of the declaration described above is in conformity with Directives: 

2014/35/EU 

Low voltage standard 

2014/30/EU 

Electromagnetic compatibility 

2011/65/EU 

RoHS Restriction of the use of certain hazardous substances 

Employed standards: 

 

EN 60730-1: 2011 

Automatic electrical controls for household and similar use 

  

Part 1: General requirements 

EN 61000-6-3: 2007 
                +A1: 2011 
                + AC2012 

Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - 
Emission standard for residential, commercial and light-industrial 
environments 

EN 61000-6-2: 2005 
                + AC2005 

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - 
Immunity for industrial environments 

EN 50581: 2012 

Technical documentation for the assessment of electrical and electron-
ic  
products with respect to the restriction of hazardous substances 

Position of CE - label:

  On packaging, manual and type label 

 

 
 
 

Issuer: 

Technische Alternative RT GmbH 
A- 3872 Amaliendorf, Langestraße 124 

This declaration is submitted by

 

 

 

Dipl.-Ing. Andreas Schneider, General manager,  
02/02/2017 

 

This declaration certifies the agreement with the named standards, contains however no warranty of 
characteristics. 
The security advices of included product documents are to be considered. 

 

 

 


background image

 

 

 

 

 


background image

 

 

Guarantee conditions 

 

Note: 

The following guarantee conditions do not in any way limit the legal right to a guaran-

tee; rather expand your rights as a consumer. 

 

1.

 

The company Technische Alternative RT GmbH provides a two-year guarantee from the date 
of purchase by the end consumer for all the devices and parts which it sells. Defects must be 
reported immediately upon detection and within the guarantee period. Technical support 
knows the correct solution for nearly all problems. In this respect, contacting us immediately 
will help to avoid unnecessary expense or effort in troubleshooting.  

 

2.

 

The guarantee includes the free of charge repair (but not the cost of on site fault-finding, re-
moval, refitting and shipping) of operational and material defects which impair operation. In 
the event that a repair is not, for reasons of cost, worthwhile according to the assessment of 
Technische Alternative, the goods will be replaced.  

 

3.

 

Not included is damage resulting from the effects of overvoltage or abnormal ambient condi-
tions. Likewise, no guarantee liability can be accepted if the device defect is due to: transport 
damage for which we are not responsible, incorrect installation and assembly, incorrect use, 
non-observance of operating and installation instructions or incorrect maintenance.  
 

4.

 

The guarantee claim will expire if repairs or actions are carried out by persons who are not au-
thorised to do so or have not been so authorised by us or if our devices are operated with 
spare, supplementary or accessory parts which are not considered to be original parts. 

 

5.

 

The defective parts must be sent to our factory with an enclosed copy of the proof of pur-
chase and a precise description of the defect. Processing is accelerated if an RMA number is 
applied for via our home page 

www.ta.co.at

. A prior clarification of the defect with our tech-

nical support is necessary. 

 

6.

 

Services provided under guarantee result neither in an extension of the guarantee period nor in 
a resetting of the guarantee period. The guarantee period for fitted parts ends with the guaran-
tee period of the whole device.  

 

7.

 

Extended or other claims, especially those for compensation for damage other than to the de-
vice itself are, insofar as a liability is not legally required, excluded. 
 

 

Legal notice 

These assembly and operating instructions are protected by copyright.  
Use  outside  the  copyright  requires  the  consent  of  the  company  Technische  Alternative  RT  GmbH. 
This applies in particular to reproductions, translations and electronic media. 

 

Technische Alternative RT GmbH 

A-3872 Amaliendorf Langestraße 124 
Tel ++43 (0)2862 53635                     Fax ++43 (0)2862 53635 7 

 

E-Mail: 

mail@ta.co.at

                      --- 

www.ta.co.at

  ---                                © 2018