background image

 


background image

You’re about to enter an exciting new labor saving world of elevation mea-

surement and leveling. The 

ZIP

LEVEL

®

 PRO-2000

 High Precision Altimeter 

lets you focus on your work rather than the tedious task of measuring your 

work. 

ZIP

LEVEL

®

 is the first instrument of its kind to let you truly work alone, 

set-up  instantly  and  measure  without  line-of-sight,  distance  error,  factory 

calibration or math. 

Unlike  conventional  builder’s  and  laser  levels, 

ZIP

LEVEL

®

  displays  verti-

cal measurements directly in large, easy to read digits. Select one of six 

scales and cover up to 40’ (12m) vertically with 0.050” (1mm) precision over 

a 200’ (60m) circle on a single set-up – equivalent to owning five 40’ (12m) 

rods and an imaginary 20’ (6m) tripod. The High Precision function provides 

paper-thin precise vertical readings within 0.005” (0.1mm) over 4’ (1.2m). A 

built-in Carry Function retains your original benchmark Zero over unlimited 

ranges without the differential leveling tabulation, tedious calculations and 

endless errors.

INTRODUCTION

ZIPLEVEL SYSTEM CONCEPT

200’ (60m) CIRCLE

SINGLE SET-UP RANGES

+20’ (6m)

Unipod

Measurement

Module*

Cord

Base Unit

*Zero at any reference 

within range

-20’ (6m)

 


background image

Use any of 

ZIP

LEVEL

’s 16 powerful built-in functions to master tough ele-

vation measuring and leveling tasks from estimating, planning, excavation, 

construction and landscaping to fabrication, checking and analysis. Attach 

the  optional  PC  Serial  Link  to 

ZIP

LEVEL

’s  built-in  Serial  Port  and  make 

ZIP

LEVEL

®

 a powerful data gathering instrument capable of downloading 

stored measurements to a Personal Computer for analysis and tabulation or 

plots of profiles, sections and topographical maps.

Carefully review this User Guide and with a little practice you’ll soon cut 

time, cost and frustration from your work.

INTRODUCTION

 

ZIP

LEVEL

®

 Basics ..............................  1-6

 

Quick Start .......................................  7

 

On/Off, Hold & Zero...........................  9

 

Scale & Resolution ............................  11

 

Calibration ........................................  13

 

Record .............................................  15

 

Mark  ................................................  17

 

Temperature & High Precision ............  19

 

Carry ................................................  21

 

Record Data .....................................  23

 

Inspect/Dump & Initialize ...................  25

 

Elevation ..........................................  27

 

Monitor .............................................  29

 

Display Alarm Indicators ....................  30

 

Use Tips ...........................................  31

 

How to Measure Accurately ................  32

 

ZIP

LEVEL

®

 Care .................................  34

 

Troubleshooting ................................  36

 

Maintenance/Product Assistance ........  37

 

ZIP

LEVEL

®

 Specifications ...................  38

LABELED

FUNCTIONS

HIDDEN

FUNCTIONS

TABLE OF CONTENTS

 


background image

ZIP

LEVEL

®

 consists of a Base Unit (BU) and hand-held Measurement Mod-

ule (MM) joined by a rugged wireless Cord that communicates elevation data 

from the BU to the MM. Stakes secure the Base Unit on unstable terrain. A 

Unipod eliminates constant bending for multiple readings and doubles as a 

vertical calibration standard when fully extended. All components are stored 

in the Base Unit when not in use. To use 

ZIP

LEVEL

:

1)  Secure the Base Unit on its back at any convenient location and pull 

enough Cord from the reel to cover the area to be measured. If desired, 

attach the Unipod to the Measure Module. Although it is not necessary 

for the Base Unit to be level, it must be secure.

2)  Momentarily press the ON/OFF key to turn on the 

ZIP

LEVEL

®

.

3)  Press the ZERO key for 2 seconds to set a level zero plane at any refer-

ence or benchmark within 

ZIP

LEVEL

’s 200’ (60m) horizontal, and +/- 20’ 

(6m) vertical range. 

Note: If the Base Unit moves, you must re-zero the Measurement Module at 

the benchmark before continuing.

1  ▪  ZIPLEVEL BASICS

ZIPLEVEL PARTS  ▪  2

To remove the boot:

1.  Place against chest

2.  Pull back 1” with 4 fingernails each side.

3.  Grip Measurement Module and Boot

  and pull Boot off.

Serial Port

Boot

Battery

Unipod Port

(This is easier when warmed.)

Cord 

Reel

Storage

Measurement

Module Docking

      Area

Display

Keypad

Cord

Staking

Locations*

MEASUREMENT 

MODULE

BASE UNIT

*Stake through handle area

if Unipod remains in Base Unit

Unipod

Two Stakes

Three Feet

Quick

Reference

Guide

BASE UNIT 

REAR VIEW

Reel 

Retaining 

Screw

Typically on 

back side

during use

 


background image

Use the Measurement Module to level and take readings. The bottom and 

back of the Module are the only sides that may be used interchangeably for 

measurements. You may use other sides only if you first zero on that side. 

Hold the Module level and measure near the center of the side in use. Do not 

zero the Module and then invert it without correcting the reading as shown in 

the illustration on the next page.

Example: To measure the distance between the floor and ceiling: First, zero 

the Measurement Module on its back or bottom on the floor. Then place its 

top, bottom, or back against the ceiling to take a reading. Finally, add the 

appropriate correction factor shown in the illustration.

3  ▪  MEASUREMENT MODULE

H = Display

+

3.5” or 3.75” with Boot

MEASUREMENT MODULE  ▪  4

Display reading is equivalent for measurements 

taken from back or bottom.

To avoid adding values, use the same side for

start and finish, without rotating or inverting.

H = Display

Measurement

Module Rotated

H

RIGHT

WRONG

Typical Use

Must add value to reading in these three examples.

For Measurement Module Inverted

H = Display

+

2.0” or 2.25” with Boot

H = Display

OR

OR

OR

OR

H

H

H

 


background image

Use the keypad on the Measurement Module to control the 

ZIP

LEVEL

®

 and 

take readings. The most frequently used functions, called labeled functions, 

are printed on the eight keys below the display.

ZIP

LEVEL

’s more advanced or less frequently used functions, called hidden 

functions, may be accessed by logical combinations of two or more keys. All 

keys except the HOLD and ON/OFF keys must be pressed and held for two 

seconds to activate. This minimizes accidental operation of the functions.

Distinctive audible and display indicators ease use – you will soon learn to 

recognize them. For example, when a measurement is nearly stable enough 

to read, you will hear two short ‘read ready’ beeps. When storing a reading, 

ZIP

LEVEL

®

 emits short, regular beeps while the display flashes. When the 

reading is stable enough to store, the unit then emits a single long tone.

Note: All stored measurements and settings are retained indefinitely once 

power is shut off and even without a battery installed.

5 ▪ KEYPAD

KEYPAD & DISPLAY  ▪  6

Flashes when 

battery is low.

Flashes when calibration is 

required due to temperature.

Main Display Digits

Flashes when re-zero required

due to temperature.

Scale 

indicators

Fraction bar flashes 

in MARK mode.

Every key clicks 

and beeps when 

pressed.

Hand grip area

Press 2 seconds 

for these 6 keys

to enter function.

Record indicators

REC flashes in RECORD DATA function.
On when display value is frozen.

 


background image

Most 

ZIP

LEVEL

®

 users will use only those functions routinely necessary in 

their work. We suggest that you try all 

ZIP

LEVEL

®

 functions at least once 

to become familiar with its capabilities. This Quick Start will help you gain 

confidence by using a few frequently used functions:

1.

 Raise the lower door of the Base Unit, remove the Measurement Module 

and lay the Base Unit on its back on the floor or ground. The Base Unit 

should be secure but need not be level.

2.

 Pull enough Cord from the reel to cover the area to be measured and 

momentarily press the ON/OFF key to turn the unit on.

3. 

Place the Measurement Module on a nearby surface and press the ZERO 

key for 2 seconds and hold steady until zeroed. You have now created an 

imaginary infinite size level reference plane.

4.

 Move the Measurement Module to a different elevation. It will display the 

difference in elevation with negative readings below and positive above the 

reference plane. 

5.

 Momentarily press ON/OFF key to shut off unit. Reel in the entire Cord 

letting twists near MM spin out, put Module in its docking area and lock door.

WARNING: READ & UNDERSTAND ENTIRE USER’S GUIDE BEFORE USE.

7  ▪  QUICK START

MECHANICS OF USE  ▪  8

Slowly move 

from side to side 

to make Cord 

uniform on reel

Typical Handling 

Suggested Reeling Technique

Cord Removal

Manage Cord with left hand, gently ‘whip’ 

over small objects.

Thumb can reach 

the 3 most used

keys

For consistent readings, 

balance with Unipod 

between middle fingers like 

a plumb-bob before

contacting surface.

Easiest Cord 

removal

direction

Docking area

Avoid pulling or winding 

Cord in docking area

Quick jerks may cause 

reel over-spin and 

Cord jams

Rest ‘round’ 

against thigh

Dock

Measurement 

Module face-up

 


background image

This  section  describes  how  to  operate 

ZIP

LEVEL

’s  labeled  functions. 

Glance through all the functions and illustrations then try each function on 

the 

ZIP

LEVEL

®

.

ON/OFF

Momentarily  press  to  turn 

ZIP

LEVEL

®

  on  or  off.  Without  a  key  press  or 

movement within 3 minutes, two long warning beeps will sound followed by 

automatic turn off at 4 minutes. All settings and data are retained.

HOLD

Momentarily press to freeze an elevation on the display. Press again to re-

lease. Use when the display is not visible, when measuring ceiling sag with 

the Unipod, in dimly lit areas, etc.

ZERO

Press for 2 seconds to make the current elevation a reference or benchmark 

plane. Re-zero at new elevations like large level steps, pool bottoms or block 

courses to let 

ZIP

LEVEL

®

 do the high/low math.

9  ▪  LABELED FUNCTIONS

When zeroed 

above…

Will read 

-10.00’ below

HOLD & ZERO  ▪  10

Press HOLD before the Module is in position - the reading 

will lock on the display when movement stops.

Display not visible

ZERO 

here first

Deep, dark trench

Framing

-10.00’

New reference plane

Original reference plane 

(set during calibration)

HOLD

ZERO

 


background image

SCALE

Press for 2 seconds and continue to press or press and release to select 

fractional  inches  (”),  decimal  inches  (IN),  engineer’s  feet  (FT),  builder’s 

feet-inches (FT-IN), centimeters (CM) or meters (M). Fractional scales and 

meters are not available in the High Precision function (Pages 19 & 20). If 

you HOLD a reading on the display then SCALE can be used as a scale 

converter.

RES

Press 2 seconds to enter and continue to press or press and release to se-

lect the desired measurement RESolution (measurement precision). Lower 

resolution (larger values or increments) provides faster readings for rough 

grade or estimates.

11  ▪  SCALE & RESOLUTION

SCALE & RESOLUTION  ▪  12

Shorter

Time for reading to 

stabilise

Fractional inches
Decimal inches
Feet
Feet - Inches
Centimetres

Meters

EQUIVALENT

DISPLAY READINGS

Right end of display

TYPICAL DISPLAY

(Decimal Inches Scale )

Use for highest precision

Use for intermediate precision

Use for rough measurements

Longer

RES

SCALE

Se

lec

tio

Se

qu

en

ce

 


background image

Unlike rotary lasers and optical levels, the 

ZIP

LEVEL

®

 is not tilt sensitive, 

its level plane does not develop tilt error and it does not amplify error with 

distance or require factory calibration. The CAL function lets you calibrate 

vertical measurement accuracy much like calibrating the vertical sight rod 

of a rotary laser. Calibration may be needed for accurate vertical measure-

ments but is not required for leveling operations. 
Always  check  calibration  before  doing  accurate  vertical  measurements, 

particularly if the temperature has changed 36°F (20°C) or more since the 

last calibration causing CAL to flash on the display or if you have never 

calibrated a new or newly serviced 

ZIP

LEVEL

®

. You can easily check cali-

bration in two steps: 1) Zero the Measurement Module on bottom or back 

on a flat surface beside the Base Unit. 2) Raise the Measurement Module 

4’ (121.9 cm) above the zero point (still on bottom or back) to be sure the 

display closely matches the height raised. The fully extended and calibrated 

Unipod,  a  sheet  of  plywood  or  a  tape  rule  can  be  used  as  a  calibration 

standard. If calibration is necessary then follow the easy 3 steps in the il-

lustration. You can exit from calibration at any time by pressing the CAL key 

for two seconds.

13  ▪  CALIBRATION

Step 1  Press CAL 2 seconds to start 3 beep tone.

Step 2  Lay bottom or back down close to

 

Base Unit and press CAL again

 

[   ] 

0 display*

 

Then [48] or [121.9] flashes and 2 beep tone

Step 3  Raise to 48”(121.9cm), press CAL again and hold steady

 

[   ] 

48” or 121.9cm  display*

 

Then normal display resumes as 48” or 121.9cm

 

*a single beep sounds until value is locked in.

CALIBRATION  ▪  14

To adjust length, loosen jam nut,

turn foot in or out and re-tighten nut.

To reverse foot for pointed end,

remove foot and rubber tip, place

jam nut in opposite end of foot,

reassemble foot, blunt end first,

back into Unipod, adjust and

tighten jam nut.

Same spot

Occasionally check 

Unipod for 4’ with a 

tape rule.

To collapse,

loosen/tighten from 

bottom up (3, 2, 1)

To extend, 

loosen/tighten 

bushings top 

down (1, 2, 3)

Rubber 

tip

Adjustable and reversible foot

Unipod

Jam nut

Step 3

Step 2

CAL

48.00”

(121.9cm)

 


background image

The RECord function eliminates extensive tabulation and computation re-

quired to average large numbers of readings. Now you can easily estimate 

the slurry necessary to level an uneven concrete surface, the fill needed 

below concrete or predict the graded level of a hilly lot (see illustrations). 

You can also estimate the volume of a pile of dirt or the volume to fill a hole 

by first finding the difference between the average of readings every pace 

around the edge of the pile or hole and the average of readings at every 

pace criss-crossing the pile or hole. Volume = (difference of the two aver-

ages) X (estimated cross-sectional area of the pile or hole). 

To enter the record function, press REC 2 seconds causing REC to appear 

on the display. Momentarily press REC to display current reading, AVG (av-

erage), MIN (minimum) or MAX (maximum). Press HOLD momentarily to 

include each of an unlimited number of readings in the computations.

Press REC 2 seconds to exit the Record function. Previously computed data 

will be replaced with new data if you press the HOLD button after re-entry.  

15  ▪  RECORD

RECORD  ▪  16

Bench mark

Predicted 

level lot

Existing lot

Predicting lot elevations

Average = final elevation relative to 

benchmark after cut and fill.

5’, 10’ or any measurement intervals

Calculates fill needed below concrete.

ZERO at bottom level for concrete, take as many measurements as needed.

Volume = Average x Area

Can compute average, minimum and 

maximum error from level around forms.

REC

 


background image

The MARK function lets you create audible tones: 1) at a selected elevation, 

2) for elevations within a selected band, or 3) elevations outside a selected 

band. Tones may be set over 

ZIP

LEVEL

’s full vertical single setup range.

To set tones, place the Measurement Module at the desired elevation, press 

MARK 2 seconds and hold steady until double band lines flash on the dis-

play then press MARK momentarily: 1) without moving the Module for a tone 

at the elevation or 2) after moving the Module below for a tone within the 

band or 3) after moving the Module above for a tone above the band, beeps 

below and silence within. The fraction bar to the right flashes while in the 

Mark function.

 

Press the MARK key 2 seconds to exit – settings will be lost. To exit and re-

tain settings, momentary press ON/OFF while pressing MARK. Press MARK 

2 seconds to re-enter.

17  ▪  MARK

MARK  ▪  18

Tones can supplement display to level or alarm

at height limits.

STEP 1
DISPLAY
TONES
TONE

AT

MARK
TONE

INSIDE

OF

BAND
TONE

OUTSIDE

OF

BAND

STEP 2

Enter at elevation

Set band

Double beep

Single beep

USE FOR PRECISE LEVELING

Mark

Tone

USE FOR LESS

PRECISE LEVELING

Band

Band
Tone

No Tone

Steady
No Tone

Beeping Tone

FOR ROUGH LEVELLING OR

ELEVATION LIMIT INDICATION

MARK

 


background image

TEMPERATURE

To display ambient temperature, continue to press ON/OFF for 2 seconds 

when turning ON. Momentarily press any other key to exit temperature.
HIGH PRECISION

The High Precision function lets you measure with an unprecedented paper 

thin  0.005”  (0.1mm)  internal  precision  over  a  vertical  range  of  4’  (1.2m). 

With this revolutionary capability you can detect minute surface errors, set 

precise pool negative edges, precisely fixture shop fabrications or set plant 

equipment and do real time beam deflection measurements. The possibili-

ties are endless.
To enter or exit, momentarily press ON/OFF while pressing the RES key. 

You must re-zero when changing in or out of High Precision. When in High 

Precision, HP will appear with readings in decimal inches, feet and centime-

ters. For a lower precision, press the RES key for at least 2 seconds and 

release at the desired precision. Vertical calibration (CAL) is still done at 4’ 

(121.9cm). With the highly precise HP measurements it is particularly impor-

tant to comply with the How to Measure Accurately Guidelines on Page 32. 

Avoid interchanging Module bottom and back in the HP function.

19  ▪  HIDDEN FUNCTIONS

HIGH PRECISION  ▪  20

Feet Format

1) Press

REC

ON

OFF

2) Momentarily

  Press

Optional

Unipod Adapter

High

Precision

Floor

Survey

HIGH PRECISION RANGES

Decimal

Units

200’

(60m)

Base Unit 

Elevation

*

24.00”

24.00”

HIGH

PRECISION

*Base Unit May Be Offset +/- 5.0” (13cm)

From Vertical Range Limits.

48.00”

121.7cm

 


background image

21  ▪  CARRY

The CARRY function lets you leap-frog the Measurement Module and Base 

Unit to measure elevations (differential level) over any distance or elevation 

on earth without tabulation, computations or loss of your original benchmark 

plane. Two people working together can traverse terrain at a 2 mph (3 kph) 

rate.

To use the CARRY function follow the steps in the illustration. Repeat the 

HOLD and ZERO sequence over any distance or elevation. You may keep 

the Base Unit vertical for ease of leap-frogging if it was vertical when setting 

the benchmark.

To exit CARRY within any set-up, press and hold the ZERO key for two 

seconds without the HOLD indicator showing. You can then do a new set-up 

zero without loss of the CARRY benchmark and later re-enter CARRY by 

pressing HOLD and then ZERO for 2 seconds without moving the Module. 

You can preset the CARRY reference to any elevation such as at a survey-

ors benchmark using the ELEV function. 

CARRY  ▪  22

Can measure the height of a mountain or locate

an elevation across town – no pencil, paper or

calculator needed.

*Clear CARRY to zero

or set ELEVATION

(see ELEV) here.

Before  Base  Unit  is  moved  to  set-up  2,  be  sure  to 

‘hold’ Measurement Module securely in position

HOLD

Press

(Press 2 seconds to enter CARRY) once

Base Unit is secured at set-up 2

ZERO

Press

STEP 1
STEP 2

STEP 3

Set-up 1

Starting benchmark

Set-up 2

Set-up 3

BU

MM

BU

MM

MM

To clear

MARK

*Press 2 seconds

ZERO

CARRY

 


background image

ZIP

LEVEL

®

 can be used to record measurement data for creating tables, 

profiles, sections, contour or 3D maps. Press REC and MARK together for 

2 seconds to enter or exit. REC will be flashing on the display while in the 

Record Data function. Press REC and ZERO together for 2 seconds to clear 

all data. Press HOLD momentarily to record each measurement. Press the 

ZERO key for 2 seconds to back step and clear a previous measurement, 

then momentarily press and release to clear additional measurements.
With each measurement, the display shows that measurement’s position 

within a sequence (PXXX) and the sequence number (fraction digits). Press 

MARK 2 seconds to start a new sequence. The display will flash ‘FULL’ with 

each measurement when memory is within 20 measurements of being filled. 

The number of remaining measurements will show in the fraction digits. A 

PC  can  be  connected  to  the  serial  port  to  store,  graph  or  tabulate  each 

measurement as it is taken for an unlimited number of measurements. The 

position display will show (FXXX) after the 

ZIP

LEVEL

®

 memory is full. 

The REC DATA function can be used while in the CARRY function to record 

data with each press of the HOLD key. CARRY data and normal data won’t 

mix – storing one will delete all other data.

23  ▪  RECORD DATA

RECORD DATA  ▪  24

Press 2 seconds

to clear all data

Saves up to 137 measurements, or an unlimited number with a PC.

Take measurements over a grid of regular surface intervals for a contour or 3D map.

One sequence can define a profile or section.

momentarily to record

HOLD

Press

2 seconds, back space (erase)

ZERO

Press

Sample position display

To

start

2 seconds to start

a new sequence

MARK

Press

POSIT

ION

S

Press 2 seconds to enter

REC

MARK

ZERO

REC

DATA

 


background image

25 ▪ INSPECT/DUMP & INITIALIZE

INSPECT or DUMP

These  functions  allow  inspection  of  Record  Data  registers  and/or  data 

transfer to a PC. To use this function: Press and hold CAL and REC keys 

together for two seconds to INSPECT data. Momentarily press the MARK 

key to sequence up through positions. Momentarily press the REC key to se-

quence down through positions. To sequence up or down in multiples of ten 

positions, momentarily press the HOLD key for up and CAL key for down. 

Momentarily press the CAL and REC keys together to DUMP data to a PC.

INITIALIZE

This function resets all user settings to default values providing an easy way 

to escape from an unwanted function. It will be necessary to re-calibrate 

after you initialize. Place the Measurement Module back down on a flat sur-

face and press the entire top row of keys for two seconds with two fingers 

from each hand. 

INSPECT/DUMP  ▪  26

RECORDING DATA ‘ON THE FLY’

When ZIPLEVEL registers fill, ‘FULL’ will display

but record data to PC can continue indefinitely.

CAL

REC

MARK

HOLD

Press

 CAL and REC two seconds to enter or exit INSPECT

Press

 CAL and REC momentarily and release to DUMP data to PC

Sequence 

down

Sequence 

up

TENS

ONES

ONES

TENS

INSPECT POSITION CONTROL KEYS

PC Serial Link

Compact PC mounted to Unipod in left hand

or in pocket with display visible to operator

INSPECT

/DUMP

 


background image

Elevation lets you preset the display and Carry reference plane to a bench-

mark elevation in engineers (FT) or metric scales for use in the CARRY 

function. You may preset the ELEV function to zero by pressing MARK and 

ZERO together for 2 seconds before entering the ELEV function. To enter or 

exit the ELEV function, press and hold the SCALE and RES keys together 

for 2 seconds.

It’s best to set digits starting with the least significant—momentarily press 

the HOLD key to set the hundredths digit, press the MARK key to set tenths, 

the REC key for ones, the CAL key for tens, the SCALE key for hundreds 

and the RES key for thousands. Press the ZERO key to select up or down.

To use your preset elevation, exit ELEVATION and enter CARRY (see page 

21).

27  ▪  ELEVATION

ELEVATION  ▪  28

Allows preset of elevation in CARRY function.

First place measurement module at benchmark.

Press two seconds                                      to enter or exit

RES

SCALE

Example reading: 17,469.80 (a very high elevation!)

E for Elevation

Upper Display

Alternates

Lower Display

Start Set Here

10′

1′

0.1′

0.01′

1000′

100′

UP

DOWN

ON

OFF

End Set Here

ELEV

Display looks similar to CARRY function:

 


background image

The Monitor function can be used to keep the 

ZIP

LEVEL

®

 from shutting off 

during periods of inactivity. It also can be used with the optional PC Serial 

Link for remote monitoring or data logging. For example, place the Base Unit 

on a Styrofoam

®

 float to log water tank or river levels.

To enter the MONITOR function, press and hold the ON/OFF and CAL keys 

together for two seconds when turning on 

ZIP

LEVEL

®

. To exit, turn the unit 

off. The MONITOR function disables the AUTO-OFF feature and enables 

continuous data from the Serial Port.

CAUTION: MONITOR reduces battery life by at least 40%. Remember to 

shut off when finished to avoid loss of battery.

29  ▪  MONITOR

DISPLAY ALARM INDICATORS  ▪  30

CAL  Flashes if unit needs to be re-calibrated due to a 36F (20C) tempera-

ture change since last calibration. CAL is on constantly when unit is 

outside of the -22°F to +158°F (-30C to +70C) operating temperature 

range. CAUTION: Vertical measurements may be in error.

--0--  Periodic flash on the display indicates re-zero may be necessary 

due to a temperature change of 18F (10C) since the last zero.

8888  Alternates with displayed elevation when the Measurement Module 

is more than 20’ (6m) above or below the Base Unit. CAUTION: 

Overrange  measurements  may  be  in  error.  If  8888  flashes  well 

within range, check troubleshooting chart; check for Cord damage 

or leakage and if necessary, return for service.

BAT  Flashes when only a few hours of battery life remain. A fresh 9V 

alkaline battery can allow up to 60 hours of active use.

CORD  Flashes to indicate need for routine factory Cord recharge required 

about every 3 years or possible Cord damage. CAUTION: Measure-

ments may be in error.

*See page 6 for illustration of alarm indicators.

 


background image

1) Secure the Base Unit after removing the Measurement Module.
2) Extend the Unipod from the top down and retract from the bottom up (see 

page 14). Always gently tighten bushings (avoid over-tightening).

3) Hold the Measurement Module in the handgrip areas to the right and be-

neath the keypad. For single handed operation, use the thumb to press 

the most frequently used buttons: ON/OFF, HOLD and ZERO. The left 

hand can manipulate the Cord. Release or hold steady while reading (see 

page 8).

4) In muddy conditions use a rag to wipe down the Cord before reeling in. 

This can also remove Cord twists.

5) Place Module on ground beside Base Unit then pick up Base Unit and reel 

Cord through Cord entry area by holding the Base Unit handle with Base 

Unit tilted backward at about 45° (for example, resting against thigh). This 

will ease reeling, reduce wear and keep docking area clean (see page 8).

6) Use a coin, screwdriver or thumbnail to loosen battery door screw to re-

place 9V alkaline battery. Lift the terminal end of battery with thumbnail 

or simply thump Measurement Module against your hand and catch the 

battery. Note: The protective Boot is more easily removed when warmed.

31  ▪  USE TIPS

HOW TO MEASURE ACCURATELY  ▪  32

ZIP

LEVEL

®

 isothermal readings are typically precise to within 0.2% of mea-

surements 10’ (6m) or less and 0.35% of measurements beyond 10’ (6m). 

It can typically level to within 0.1” (2mm) or 0.01” (0.2mm) in High Precision 

over a single set-up.

1) For critical levelling frequently re-check or re-zero at the benchmark (CAL 

is not necessary for leveling). When possible minimize height differences 

between Cord, Base Unit and Measurement Module.

2) For critical elevation measurements, frequently re-check calibration and 

benchmark zero. Whenever possible avoid temperature differences be-

tween the Cord and Measurement Module (eg. sun vs. shade).

3) When moving the 

ZIP

LEVEL

®

 from one temperature to a much different 

temperature, such as from indoors to outdoors on a cold day, pull out as 

much Cord as needed and allow 10-15 minutes for 

ZIP

LEVEL

®

 to adapt 

to the change.

4) Avoid violent tugging, whipping or stomping on the cord without re-check 

or re-zero at the benchmark.

5) Promptly zero or calibrate 

ZIP

LEVEL

®

 when its display flashes –0– or CAL.

 


background image

6) Always secure the Base Unit to prevent movement during measurements 

– it does not need to be level.

7) Avoid using 

ZIP

LEVEL

®

 beyond the specified ranges of elevation or tem-

perature. The display will flash 8888 when beyond the +/-20’ (6m) vertical 

range and the CAL will be on steady for temperatures below -22°F (-30C) 

or above +158°F (+70C).

8) Occasionally check the 4’ (121.9cm) length of the fully extended Unipod 

for changes in length caused by wear. Adjust its length if necessary.

9) As with conventional instruments, additional errors may be caused dur-

ing use outdoors on sunny or windy days. In such conditions pull out only 

as much Cord as is needed and avoid unnecessary loops over objects. 

Measurements are less affected by sun/shade in early morning, late af-

ternoon, when overcast, in full shade or indoors. If a measurement varies 

when breezy, take the average reading.

33  ▪  HOW TO MEASURE ACCURATELY

ZIP

LEVEL

®

  is  rugged,  durable  and  designed  to  provide  years  of  reliable 

performance when properly used. Here are some guidelines:
1)  Avoid excessive strain on the Measurement Module by guiding the Cord 

with the left hand during use (see page 8).

2)  Whenever possible use the protective boot on the Measurement Module. 

Avoid dropping the Measurement Module and never use as a hammer.

3)  Do not immerse the Measurement Module in water or any other liquid or 

gas and avoid contact with solvents.

4)  Minimize 

ZIP

LEVEL

®

 wear by wiping with a damp cloth (avoid scratching 

display window) or rinsing lightly to remove mud and dirt from the Base 

Unit, Cord and Measurement Module. In extreme cases the single screw 

at the back of the reel can be removed to release the reel from the hous-

ing for a thorough hosing.

5)  Keep the Cord, Measurement Module or Base Unit out of the path of 

vehicle  traffic  and  out  of  contact  with  hot  objects  such  as  smoldering 

cigarette butts, fresh asphalt or welding.

ZIPLEVEL CARE  ▪  34

 


background image

6)  Pack up the 

ZIP

LEVEL

®

 when not in use for extended periods of time. 

Never leave out in foul weather or overnight. Avoid storage inside a hot 

closed vehicle or trunk.

7) 

ZIP

LEVEL

®

 contains a non-toxic biodegradable clear liquid. In the un-

likely event that a damaged unit releases liquid or if the Cord is cut, bend 

over Cord and wrap with tape or wire to stop liquid release. Wipe up liquid 

with absorbent towels, remove residue with soap and water and return to 

factory for service.

35  ▪  ZIPLEVEL CARE

TROUBLE SHOOTING  ▪  36

See page 30 for alarm indicators

 

Problem 

Action

Replace battery 

 

Unit  won’t  turn  on  or  shuts  off 

soon after turn on

Display  shows  8888  with  steady 

tone  even  though  elevation  is 

small
Unit is stuck in an undesired func-

tion and you can’t remember how 

to escape

Check for Cord kink or damage.

Initialize (see page 25)

Initialize  and  don’t  forget  to  re-

calibrate

Cord  flashes  on  display  and/or 

readings are not repeatable

Check  Cord  and  Base  Unit  and 

return to factory for 3 year interval 

recharge and/or repair if damaged

ErrX flashes on display when unit 

is switch on

Return to factory – unit may need 

service

 


background image

Technidea Corporation warrants the 

ZIP

LEVEL

®

 PRO-2000

 High Precision 

Altimeter against deficiencies in materials and workmanship for one year 

from the date of purchase. The 

ZIP

LEVEL

®

 hydro-pneumatics are covered 

by a second year pro-rata warranty.

ZIP

LEVEL

®

 never requires factory calibration and normal use should allow 

years of use without repair. Every 2 - 3 years 

ZIP

LEVEL

®

 will flash “CORD” 

on the display indicating a need for a factory recharge of its hydro-pneumat-

ics. For detailed warranty information, the location of your nearest service 

center and shipping information, visit www.ziplevel.com/service.

PRODUCT ASSISTANCE

If  you  have  difficulty  using  your  new 

ZIP

LEVEL

®

  after  reading  this  User 

Guide then please email info@ziplevel.com or call 1.800.805.LEVEL(5383) 

or 1.760.480.4740 outside the USA.

MADE IN THE USA

37  ▪  MAINTENANCE/PRODUCT ASSISTANCE

SPECIFICATIONS  ▪  38

Set-up vertical range: 

40’ (12m) (20’ (6m) above and below Base Unit)

 

48”(122cm) full range in High Precision (HP)

Set-up horizontal range:  200’ (60m) dia. Circle, (150’ (46m) PRO-2000B)

Carry function range: 

No limit

Range of zero or mark: 

Full vertical range

Reading repeatability: 

0.1” (2mm) or 0.01” (0.2mm) HP typical

Leveling accuracy: 

0.1” (2mm) or 0.01” (0.2mm) HP typical

Elevation accuracy: 

Greater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2%

 

reading <10’ (3m) & 0.35% reading >10’ typ.

Record capacity: 

16,384 with no practical limits

Record data capacity: 

137 readings

Settings/data retention:  Indefinitely, even without battery

Operating temp. range:  -22°F to +158°F (-30C to +70C)

Storage temp. range: 

-40°F to +158°F (-40C to +70C)

Shock resistance: 

Measurement Module – 5’ (2m) drop on concrete

 

Base Unit – 3’ (1m) drop on concrete

Water resistance: 

Rain tight; not immersible

9V alkaline battery life: 

60 hours active use (auto shut-off after

 

4 minutes inactive)

U.S. Patents: 4,878,297; 5,517,869; 5,726,365; 5,844,150