PDF User Manual

  1. Home
  2. Manuals
  3. TecSys C329-SPI User Manual

TecSys C329-SPI User Manual

Made by: TecSys
Type: User Manual
Category: Control Unit
Pages: 11
Size: 0.12 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

 

C329-SPI User Manual 

 

Release Note: 

V1.0   27

th

 September 2010 First release 

V1.1   12

th

 January 2012 Second release 

 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

General Description 

The C329 is a colour VGA camera module which performs JPEG compression and can be attached 
to a host via an SPI interface. Users can send a Snapshot command from the host in order to capture 
an image. The image is then compressed by the host and stored in and internal buffer and 
transferred to the host through the SPI port. 

Figure 1 – System Block Diagram 

Features 

 

Small Size, 20x28mm 

 

Adjustable resolution resolution, Max VGA 

 

3.3V operation 

 

Low Power consumption 64mA active 

 

SPI Interface with Hold 

 

Power Saving Mode 

 

Multiple lens options 

 

Multiple interface options (UART version available) 

System Configuration 

Camera Sensor 

The C329 uses a 1/4" OmniVision VGA sensor with an 8-bit YcbCr interface and 3.8 V/(Lux Sec) 
sensitivity. 

OV529 Serial Bridge 

The OV529 Serial bridge contains an Embedded JPEC CODEC and controller chip that can 
compress and transfer image data from the Camera Sensor to an external device. The OV529  
performs all imaging functions like white balance, downsizing and compressed image storage.  

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

Program EEPROM 

A Serial EEPROM provides the program code that gives the OV529 it's interface and command set. 

Board Layout 

Figure 2 – C329-SPI board Layout and Serial Interface 

SPI Interface 

Timing Options and CLK 

The SPI interface consists of MOSI (Master Out Slave In), MISO (Master In Slave Out), CLK and 
CS. In the OV529 there is the addition of HOLD which when H indicates to the Master that the 
OV529 isn't ready and should hold off the next transaction. The CS signal allows multiple devices 
to be attached to the SPI bus. When CS is L the OV529 is selected. Data on MISO will be clocked 
out on the falling edge of CLK and data on MOSI will be clocked in on the rising edge of CLK. (It 
is possible to select both clock edges, this will require a hardware change that must be ordered 
specifically. It is recommended to use the above scenario if at all possible) 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

Figure 3 – SPI Timing 

Command Set 

The C329-SPI module supports the following commands: 

Command 

Cmd Token  Parameter 1  Parameter 2  Parameter 3  Parameter 4 

INITIAL 

FFFFFF01h 

00h 

Colour Type 

Preview Res. 

Compres. Res 

GET PIC 

FFFFFF04h 

Pic. Type 

00h 

00h 

00h 

SNAPSHOT 

FFFFFF05h 

Snapshot Type 

00h 

00h 

00h 

RESET 

FFFFFF08h 

Reset Type 

00h 

00h 

00/FFh 

POWER OFF 

FFFFFF09h 

00h 

00h 

00h 

00h 

DATA 

FFFFFF0Ah 

Data Type 

Length Byte 0  Length Byte 1  Length Byte 2 

SYNC 

FFFFFF0Dh 

00h 

00h 

00h 

00h 

ACK 

FFFFFF0Eh 

Cmd Token 

ACK counter 

00h 

00h 

NAK 

FFFFFF0Fh 

00h 

NAK counter 

Err. Number 

00h 

QUALITY 

FFFFFF10h 

Quality Level 

00h 

00h 

00h 

 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

INITIAL (FFFFFF01h) 

Colour Type 

Colour Type 

Description 

02h 

Y4 

03h 

Y8 

05h 

RGB12 

06h 

RGB16 

08h 

RGB24 

09h 

YUV16 

07h 

Compression 

Preview Resolution 

Preview Resolution 

Description 

01h 

80x60 

02h 

88x72 

03h 

160x120 

04h 

176x144 

05h 

320x240 

06h 

352x288 

07h 

640x480 

08h 

80x64 

09h 

128x96 

0Ah 

128x128 

0Bh 

160x128 

Compression Resolution 

Compression Resolution 

Description 

01h 

80x60 

02h 

88x72 

03h 

160x120 

04h 

176x144 

05h 

320x240 

06h 

352x288 

87h 

640x480 

08h 

80x64 

09h 

128x96 

0Ah 

128x128 

0Bh 

160x128 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

GET PIC (FFFFFF04h) 

Picture Type 

Picture Type 

Description 

01h 

Snapshot Picture 

02h 

Preview Picture 

03h 

Serial Flash Picture 

05h 

Compression Preview Picture 

06h 

Playback Picture 

SNAPSHOT (FFFFFF05h) 

The host sends this command to ask OV529 to capture a still image. Snapshot Type must be 0 in 
order to be compatible with OV528. 

RESET (FFFFFF08h) 

Reset All means a reset of the whole system, including registers and state machines. uC will be 
rebooted. Reset State Machine means a reset of some state machines only. When the last byte of 
Reset command is FFh, the OV529 must stop the current job and perform this Reset command 
immediately. 

Reset Type 

Reset Type 

Description 

00h 

Reset All 

01h 

Reset State Machine 

POWER OFF (FFFFFF09h) 

The host sends this command to suspend OV529. 

DATA (FFFFFF0Ah) 

The C329 sends this command to pass the length of the stored image. The following kinds of data  
must be preceded by Data command to provide the data length information. Length byte 0 is Least 
Significant Byte (LSB), and Length byte 2 is Most Significant byte (MSB

). 

Data Type 

Data Type 

Description 

00h 

Register Data 

01h 

Snapshot Picture 

02h 

RGB/YUV/Preview Picture 

04h 

Compression Preview Picture 

05h 

Playback Picture 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

Length 

Image Length = len 0 + Len 1 * 100h + Len 2 * 10000h 

SYNC (FFFFFF0Dh) 

The host sends this command to start a synchronization sequence. 

ACK (FFFFFF0Eh) 

This command is a handshake command to indicate that previous transaction was succeeded. 

Command ID 

The received command ID. 

ACK Counter 

The host and OV529 maintain their own ACK counters. After transmitting an ACK command, this 
counter will be increased by 1. 

NAK (FFFFFF0Fh) 

This command is a handshake command, which indicates corrupted transmissions or unsupported 
features. 

NAK Counter 

The host and OV529 maintain their own NAK counters. After transmitting an NAK command, this counter will be 
increased by 1. 

Error Number 

The error condition number 

QUALITY (FFFFFF10h) 

The host sends this command to select image quality level. Image quality level only effects 
Compression related images. No influence on image of bypass mode. 

Quality Level 

Quality Level 

Description 

00h 

Best 

01h 

Better 

02h 

Normal 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

Command Implementation 

Power On & Power Off 

OV529 camera system requires around 1 second from power off to next power on. After power on, 
the camera requires around 1.2 second for firmware load from EEPROM and system wake up. 

SYNC 

The Remote System sends a SYNC command and awaits and ACK, the C329 then sends out it's 
own SYNC and the Remote system is expected to respond with an ACK as shown below. 

 

Commands 

The Following commands respond with ACK: INITIAL, RESET, SNAPSHOT, POWER OFF and 
SELECT IMAGE QUALITY as shown below. 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

GET PICTURE 

 

 


background image

 

 

C329-SPI-CO_UM_EN_20141014_RH 

 

TecSys GmbH  

  Karl-Theodor-Str. 55  

  D– 80803 München 

 Tel +49 89 321 990-0 

  www.tecsys.de 

 

Code Implementation 

Here is an example of how to SYNC with the C329: 

  Send Get SYNC command. (FFFFFF0D00000000h) 

  Wait 25ms 

  Did we get ACK (FFFFFF0E0Dnn0000h)? If NO repeat above command up to 60 times. 

  Did we get SYNC? If NO repeat above. 

  Send ACK command. 

Here is an example of how to establish communication with the C329 for the first time: 

  Set Remote Baud Rate to 14,400 bps 

  Get SYNC 

  Change C329 Baud Rate with command (FFFFFF0100870107h) 

  Set Remote Baud Rate to new BAUD (921,600) in this example. 

  Get SYNC 

Here is an example of the commands required to quickly capture and transfer an image 
form the C329 to an embedded system: 

  Establish communication as above. 

  Send command INIT ( FFFFFF0100870107h) 

  GET ACK (FFFFFF0E01nn0000h) 

  Send command SELECT IMAGE QUALITY (FFFFFF1000000000h) 

  GET ACK (FFFFFF0E10nn0000h) 

  Send command GET PICTURE (FFFFFF0405000000h) 

  GET ACK (FFFFFF0E04nn0000h) 

  GET ACK (FFFFFF0AnnL0L1L2h) 

  GET Image Data