PDF User Manual

  1. Home
  2. Manuals
  3. Teba therm TP-12 Installation & Manuals

Teba therm TP-12 Installation & Manuals

Made by: Teba therm
Type: Installation & Manuals
Category: Pellet stove
Pages: 19
Size: 1.54 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

İMALATCI: 
ARAL MAKINA LTD  

T +90-352 321 28 12 

www.teba.com.tr

 

TR-38070 KAYSERI/TÜRKEI                      F +90-352 321 28 14                         info@teba.com.tr 

 

 

 

Installation & Manuals

 

 

Pellet Stove With Central Heating  
 System

 

Model TP-12 

 

 

 

 

 

 

 

 

 

Tested according to 

DIN EN 13240  

 

 

 

 

 

Tip BA 1 

 

 

Please, see enclosed declaration of conformity for    
efficiency and emission

 

 

 

TR

 

 


background image

 

 

 

 

Contents 

 

1.0

 

Introduction 

 

 

 

 

 

 

 

 

 

 

2.0

 

General Information   

 

 

 

 

 

 

 

2.1

 

Safety 

 

 

 

 

 

 

 

 

 

6

 

2.2

 

Safety Distances(minimum distance) 

 

 

 

 

6-7-8 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

 

Installation and Connections  

 

 

 

 

 

 

3.1

 

Electricity   

 

 

 

 

 

 

 

 

9

 

3.2

 

Plumbing   

 

 

 

 

 

 

 

 

3.3

 

Chimney Connection   

 

 

 

 

 

 

 

4.0

 

Control Panel 

 

 

 

 

 

 

 

 

 

10 

4.1

 

Buttons   

 

 

 

 

 

 

 

 

10

 

4.2

 

Leds 

 

 

 

 

 

 

 

 

 

10

 

4.3

 

Display   

 

 

 

 

 

 

 

 

11

 

4.4

 

Errors   

 

 

 

 

 

 

 

 

11

 

4.5

 

Menu   

 

 

 

 

 

 

 

 

12

 

4.5.1

 

Combustion Power Menu 

 

 

 

 

12

 

4.5.2

 

Heating Power Menu 

 

 

 

 

 

12

 

4.5.3

 

Boiler Thermostat Menu   

 

 

 

 

12

 

4.5.4

 

Buffer Thermostat Menu  

 

 

 

 

12

 

4.5.5

 

Room Thermostat Menu  

 

 

 

 

13

 

4.5.6

 

Remote Keyboard Menu   

 

 

 

 

13

 

4.5.7

 

Chrono Menu 

 

 

 

 

 

 

13

 

4.5.8

 

Modality 

 

 

 

 

 

 

 

13

 

4.5.9

 

Programming 

 

 

 

 

 

 

13

 

4.5.9.1

 

Daily   

 

 

 

 

 

 

13

 

4.5.9.2

 

Weekly 

 

 

 

 

 

 

13

 

4.5.9.3

 

Week-end   

 

 

 

 

 

14

 

4.5.10

 

Time and Date Menu 

 

 

 

 

 

14

 

4.5.11

 

Remote Control Menu   

 

 

 

 

14

 

4.5.12

 

Calibration Menu   

 

 

 

 

 

14-15

 

4.5.13

 

Load Menu   

 

 

 

 

 

 

15

 

4.5.14

 

Summer-Winter Menu   

 

 

 

 

15

 

4.5.15

 

Language Menu 

 

 

 

 

 

 

15

 

4.5.16

 

Keyboard Menu 

 

 

 

 

 

 

15

 

4.5.16.1

 

Set Contrast  

 

 

 

 

 

16

 

4.5.16.2

 

Set Minimum Light  

 

 

 

 

16

 

4.5.17

 

System Menu 

 

 

 

 

 

 

16

 

 


background image

 

 

 

 
 
 

5.0

 

Stove Work Principles   

 

 

 

 

 

 

 

16 

5.1

 

Suitable Fuel 

 

 

 

 

 

 

 

 

16-17

 

5.2

 

Cleaning and Maintenance 

 

 

 

 

 

 

17

 

5.2.1

 

Cleaning Fire Transition Pipes   

 

 

 

17

 

5.2.2

 

Cleaning Combustion Box 

 

 

 

 

18

 

  

 

 

 

 

 

 

 

 

 

6.0

 

General Warranty 

 

 

 

 

 

 

 

 

18 

6.1

 

Warranty Policies 

 

 

 

 

 

 

 

18

 

6.2

 

Complaints 

 

 

 

 

 

 

 

 

18

 

 

7.0

 

Informations to Order Spare Parts   

 

 

 

 

 

19 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 

 

 

Pellet stoves which is environment friendly and provide comfortable and easy-to-use interior aqueous 
and dry system, have taken place of dry stoves which used in Turkey and over the World. 
 
Pellet stoves is used to heat some areas like homes, work places…etc. These are heating units that 
combine pleasure with fireplace view, comfort with its efficiency and fuel save; which provide equal 
heat distribution through radiators. 
 
In this context, as a result, on all test in our manufacturing plant since 2011, first air and hydro pellet 
stoves (which are automatical, and work with pellet fuel that is renewable energy source) are 
produced. And we got %90 efficiency. In 2014, we started to sell in Turkey and abroad by producing 
all capacity. 
 
You have a central heating pellet stove with European Standarts Quality Certificate. 
Please Read Carefully the user manual. Product functions and easy-to-use informations are described 
in the manual. 
 
Use of these informations increases product quality and extend its life. Also fuel saves can be made 
with a correct combustion thus protect the environment.  
 
Warranty of the product depends on the right use of installation and instructions as described in the 
guide. 
 
We advice you to hide the guide in order to reach to necessary descriptions of the stove every winter.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

 

 

 

1.0

 

Introduction 

Consumption of Pellet (environmental fuel) that is preferred by all European countries 
It has no risk for poisoning since it doesn’t contain carbon monoxide 
Electronical control system 
Automatical ignition 
To set-up of combusti on speed at 5 stage 
To keep the boiler water temperature at a requested temperature 
Remote Control system 
To blow air 
To connect to radiators 
To control by room thermostat 
It provides easy and comfortable using with these features 
Pump, fan, expansion tank and thermostat are keeped inside the stoves 

 

 

 

 

 

 
 
 
 
 
 
 

 


background image

 

 

 

2.0

 

General Informations 

 

All required standart examinations have been made for your product. Predicted parameters 
associated with combustion efficiency and exhaust gas emissions are observed. The conformity of the 
product described in this manual was tested in IMQ Primacontrol Laboratory 
Pellet stoves provide comfortable and easy use through heating radiators, blowing hot air to ambient 
and fireplace view. 
Pellet stove is a full automatic device. Expansion tank, circulation pump, thermostat, safety valve, 
switch,  sensor and similar parts are located inside the stove safely. 
Pellet stove provides to ignition through resistance, loading fuel through auger and reductor, also 
blowing and emission of chimney through fans.  

 

2.1

 

Safety  

 

Product assembly and plumbing connection must be installed also by authorized person. 
Before installing stove, lifting capacity of the installation ground should be checked whether it is 
resistant for stove. In case of low resistance or low lifting capacity, suitable precautions must be 
taken.(for example a stove lifting plate must be put) If the floor stove installed is flammable or heat-
sensitive, you should place the product on a protection plate floor (marble or glass substrate). 

You should care about air condition for the area stove is installed and take measures against freezing 
The stove can be used with multiple chimney system. 
Chimney can be given outside directly according to place of stove. Or can be connected to available 
chimney in short distance. 
Our company is not responsible for the problems that can occur because of this. 
Prefer quality pellet to obtain heat efficiency and to make life of device long. Don’t use wet or moist 
pellet, shavings, wood or coal…etc. 
Pellet stove shouldn’t be installed in an area like bathroom, cellar, coal-hole since the stove designed 
for indoors. 

Attention! Before using stove and radiators please control water level. 

*** Stove should not be used without water.*** 

Our company is not responsible for the problems that can occur because of this. 

 

 

2.2

 

Safety  Distances(minimum distance) 

 

While installing the stove, fire regulations and chimney’s instructions must be complied. For any 
related questions please ask chimney provider. Flammable or heat-sensitive materials (furniture, 
wallpaper, wood paneling) minimum distances must be complied with (see diagram below): 

 


background image

 

 

 

A

 

20 cm from back wall 

B

 

20 cm from lateral Wall and  

80cm from radiation area

 

In the radiation field of the flame monitor cover (C), at 80 cm distance, combustible materials and 
furniture should notbe placed. 

This distance can be reduced to 40cm when the protection panel which inhibits the passage of heat is 
put between stove and combustible materials. 

Minimum distance combustible materials and furnitureis stated on the product label and must not be 
exceeded.If the floor stove installed is flammable or heat-sensitive, you should place the product on a 
protection plate floor (marble or glass substrate).   

 

In this case minimum dimensions of stove bottom plate( look at drawing) 

 

D  

50cm ( front lenght)

 

30cm (lateral lenght of inner egde of fire chamber cover) 

 


background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK WALL 

LA

TERAL

 WALL

 

FLO

OR

 PRO

TEC

TI

O

N

 P

LATE

 

RADIATION AREA 

 

You can order floor protection plate from seller when you require.  

 

 

 


background image

 

 

 

3.0

 

Installation and Connection 

Product assembly and plumbing connection must be installed also by authorized person. 
Pellet stove is a full automatic device. Expansion tank, circulation pump, thermostat, safety valve, 
switch,  sensor and similar parts are located inside the stove safely. 
 

3.1.

 

  Electricity  

Electricity system should be 220V-230V/50Hz. Our company is not responsible for any problem which  
occur in case sudden low or high volt. 

Note: Keep plug of device on outlet during summer-winter. Protection freezing Works under +8 °C. 
It makes pump work 15-20 seconds for per 24 hours automatically to avoid lock pump. 
 

3.2.

 

Plumbing 

Technically, stove radiator plumbing connections should be made by an expert or qualified person to 
guarantee a correct operation. Our company is not responsible for any mistakes that will occur while 
installing and assemblying 
After taking all safety measures, main line pipes can be connected until last a few radiators with 
1”pipe(PVC or metal) without more elbow. Thus hot water can circulate easily, and so you feel heat in 
the shortest time. Later ¾ pipes(PVC or metal)can be used. 
Plumbing main line pipes should be connected to radiators safely with connection apparatus like 
assembly diagram.(record, valve, nipple). After connection, water is added with help of valve from 
point that is determined by expert. And later tightness must be controlled and taken air on radiators 
and valves. 
You should put antifreeze on plumbing against freezing and corrosion, according to climate 
conditions. 

 

3.3.

 

Chimney Connection

 

We advice steel chimney pipe for chimney connections. Pellet stove can be connected to multiple 
chimney. Chimney can be given outside directly according to place of stove. Or can be connected 
available chimney in short distance. 

 

 


background image

 

 

10 

 

 

4.0

 

Control Panel 

 

 

4.1

 

Buttons 

 

 

4.2

 

Leds 

 

 

*Only for plumbing with Flow Switch

 


background image

 

 

 

 

4.3

 

Dısplay 

 

 

4.4

 

Errors 

 

 

 

 

 


background image

 

12 

 

4.5

 

Menu 

 

Push P3 button to enter in the User Menu 

 

Using P4 and P6 buttons it is possible to select the desired Menu or Submenu. Push P3 button to 
enter in desired Menu or Submenu. 

 

To decrease or increase value push the buttons P4 or P6; to save the new vale push the button P3; to 
cancel the modifies and restore the old parameter’s value push the button P1. 
If a parameter value is changed, the new value is sent to the control board; if the transmission 
failures appears the message “Transfer not successful”: in this case modify again the parameter’s 
value. 

 

4.5.1

 

Combustion Power Menu  

This Menu allows to set the system’s combustion in automatic or manual mode (in this case it is 
possible to set the combustion power). 

 

4.5.2

 

Heating Power Menu  

This Menu allows to manage the system’s heating in automatic or manual mode (in this case it is 
possible to set the heating power). 
If the user chooses the automatic mode, the heating is proportional to the exhaust temperature or to 
the room temperature or equal to the combustion power. 

 

4.5.3

 

Boiler Thermostat Menu  

Menu which allows to modify the Boiler Thermostat’s value. It is possible to program the minimum 
and the maximum value of the Boiler Thermostat setting the 

Th26 

and 

Th27 

Thermostats. 

 

4.5.4

 

Buffer Thermostat Menu  

Menu which allows to modify the Buffer Thermostat’s value. This Menu is visible only setting 
a plumbing plant with a Buffer probe. 
 
 

 


background image

 

13 

 

4.5.5

 

Room Thermostat Menu 

 

Menu which allows to modify the Room Thermostat’s value. 

4.5.6

 

Remote Keyboard Menu  

Menu which allows to enable the Room Thermostat of the Remote Keyboard. 

 

4.5.7

 

Chrono Menu  

Menu to set the time to switch on and off the stove or the boiler. It has 2 Submenu: Modality and 
Program. 

4.5.8

 

Modality  

This Menu allows to:  
 disable the ignition/extinguishing of the system by chrono  
 choice the modality (Daily, Weekly or Week-End) to switch on and off the stove or boiler. If a 
chrono modality is set, on main frame appears the relating symbol (D=Daily, W=Weekly, We= Week-
End)  

 

 

4.5.9

 

Programming 

 

This Menu allow to set the time slot the favourite modality (Daily, Weekly, Week-End). If it is selected 
the modality:  

4.5.9.1

 

Daily 

 

 

Select the day of week and program the times to switch on and off the system; for each day there 
are3 time slots 

 

 

 

 

4.5.9.2

 

Weekly 

 

Program the times to switch on and off the system: there are 3 time slots. 

 

 


background image

 

14 

 

 

4.5.9.3

 

Week-End  

Choice between "Monday-Friday" and "Saturday-Sunday". There are 3 time slots for each period. 

 

 

 

The 3 programs modality are saved separately: for example, if it is set the daily mode, the others 
mode aren’t modified.  

IMPORTANT: after the Chrono programming to switch on the system by Chrono it is necessary to 
enable the desired mode (Daily, Weekly or Week-End) from Modality Menu. 
 

4.5.10

 

Time and Date Menu  

This Menu allows to set time and date. Push the button 

P4 

and 

P6 

to select hours, minutes, year, 

month and day. Push 

P3 

to enter editing, 

P4 

and 

P6 

button to change the value. Push 

P3 

to save and 

P1 

to exit. 

 

4.5.11

 

Remote Control Menu 

 

This Menu allows to enable or disable the Remote Control SYTX.

 

 

 
 

4.5.12

 

Calibration Menu 

 

This Menu allows to modify the Combustion Fan’s speed and the Auger’s work time set by factory. It 
has two Submenu. 

 


background image

 

15 

 

 

The system has 10 calibration’s steps (the 0 value is set by the factory). For each step the value is 
increased or decreased of a per cent value (the per cent value is set in the Step Calibration Menu of 
System Menu).  
The calibration’s effect is valid only in Run Mode and in Modulation for the current recipe. 
 

4.5.13

 

Load Menu  

This menu allows load manually the Auger or the brazier. 

 

The loading stops automatically after 600 seconds. 

The system has to be in Off State to do the 

loading. 

 

NOTE

: when the auger is manually started the Exhaust Fan switches on in order to close pins 

13-14 

(HV2) for the power supply of the auger. 
 

4.5.14

 

Summer - Winter Menu  

Menu to modify the plumbing plant functioning according to the season. On display appears one of 
these symbols:

 , .  

 

4.5.15

 

Language Menu  

This Menu allows to change the language of LCD panel. 

 

 

4.5.16

 

Keyboard Menu  

Menu to set the contrast and light of LCD panel. 

 

 
 

 


background image

 

16 

 

4.5.16.1

 

Set Contrast 

 

This Menu allows to set the display contrast.

 

 

Push the buttons 

P4 

and 

P6 

to increase or decrease the contrast; 

P3 

to save and exit, 

P1 

to exit 

without save. 

4.5.16.2

 

Set Minimum Light  

This Menu allows to set the display light when you don’t push any button. 

 

 

4.5.17

 

System Menu 

THIS MENU IS FOR AUTORIZED PERSON. 

5.0

 

Stove Work Principles 

Only adults should use stoves. Children should not stay alone and close to stove. Stoves should only 
be used according to this manual. Safety instructions described in section 2.1 should be followed. 

5.1

 

Suitable Fuels 

Pellet is a solid fuel which is obtained by  compressing wood wastes at high pressure after drying, 
grinding and making shavings and diameter of pellet 6-8 mm. 
Wood pellet contains approximately 7-12% moisture. Its calorie higher than wood since its moisture 
rate is low. 
There are at least 3 steps while producing pellet. Firstly, wood wastes are made shavings by grinding, 
after that they are dried with minimum moisture, later compressed, made cold and packaged. After 
these process,, combustion and energy efficiency of trees increases 300% and so contribute 
economy, environment and nature. It means that fuel amount decrease at rate 1/3, in addition lower 
damage on forest and lower cost. 

Advantages

 

It is a sustainable source. It contributes to economy and decreases imports of fossil fuel 
It is acceptable for environment and health. After using ash is very low. 
It is less dangerous than the other fossil fuels 
It is used for producing electricity 
It is under acceptable CO oscillation threshold values according to Kyoto Protokol 
The cleanest of solid fuel is pellet 
It is easily provided over the World 
Transpotation of wood pellet is very easy 

 


background image

 

17 

 

It is not necessary to cut trees for commercial pellet. Wood wastes are used and so it can be burned 
easily. Also, it contributes to avoid forest fire since wastes are collected 
It needs smaller area compared to wood 
During using other solid fuels, creosote occurs on chimney and for pellet there is almost no creosote. 
Thus it is not neccessary to connect to a chimney, smoke can be given outside directly from its 
chimney output 

 

 

 

5.2

 

Cleaning And Maintenance 

 

 

 

 

 

 

 

 

5.2.1

 

Cleaning Fire Transition Pipes 

Fire transition pipes can be cleaned easily by help of the parts number 1 and 3. To clean pipes on the 
top you can use the part number 6. After openning the fire chamber cover, put the part 6 inside the 
hole(2), and later move it to right and left. 
To clean pipes on the top you can use the part number 5. Put the part 5 inside the hole(4), and later 
push back and forth.

 

 

 


background image

 

18 

 

5.2.2

 

Cleaning Combustion Box

 

The time of combustion box cleaning frequency depands on quality of pellet fuel. This part should be 
cleaned Daily or weekly. 

 

 

 

6.0

 

General Warranty 

6.1

 

Warranty Policies 

TEBA THERM provide guarantees to the buyer within the framework of legal provisions. Two-year 
warranty periode which starts from the date of delivery, to benefit from warranty legal policies 
please keep your bill. 

Pump, glass, faults on control board because of low or high voltaj, wrong use are out of warranty. 

If your product damages within warranty period our company will tries to resolve the dammage or 
will replace dammaged part. Only submitted and approved spare parts provided by manufacturer 
should be used.  

Upon the end of the warranty period, we wish to emphasize our customer service is at your disposal 
in the current conditions. 

6.2

 

Complaints 

 

We ask you to direct your complaints to your dealer. You definitely need to specify your stove model. 
This information is stated on the back of the product. 

 

 


background image

 

19 

 

7.0

 

Informations to Order Spare Parts 

 

You should contact your spare parts provider. 

 

Attention!!! Stove place should not be changed. Only advised and approved spart parts of 
manufacturer should be used. In case of need please contact your dealer or provider. 

 After the publication of this manuel, the company reserves the right to make changes.