1MN0046 REV. 0 

 
 
 
 
 
 

 

        operates with ISO9001 certified quality system

 

 

 

 

http: //www .tecsystem.it 

 

 

                                                       R. 1.4 07/11/16 

 
 
 

 

 

                                                         

 

“Translations

 

of

 

the

 

original

 

instructions”

 

TECSYSTEM S.r.l.

 

20094 Corsico (MI) 

Tel.: +39-024581861 

Fax: +39-0248600783 

VRT200

 

INSTRUCTION MANUAL 

 

ENGLISH

 


background image

VRT200

 

 

 

 

 

 

 

First of all we wish to thank you for choosing to use a 

TECSYSTEM

 product and recommend you read this instruction 

manual carefully: You will understand the use of the equipment and therefore be able to take advantage of all its 
functions. 

 

ATTENTION! THIS MANUAL IS VALID AND COMPLETE FOR THE UNIT VRT200  

 
 

 

 

 

 

PAGE 

1)   SAFETY REQUIREMENTS 

………………………………….. 3 

2)   ACCESSORIES 

………………………………….. 4 

3)   TECHNICAL SPECIFICATIONS 

………………………………….. 5 

4)   FRONT PANEL 

………………………………….. 7 

5)   INSTALLATION 

………………………………….. 8 

6)   ELECTRICAL CONNECTIONS 

………………………………….. 9 

 

VRT200 BACK 

………………………………….. — 

 

POWER SUPPLY 

………………………………….. 10 

 

OPERATION 

………………………………….. — 

 

HOW TO CHECK THE ALARM STATUS 

………………………………….. — 

 

HOW TO RESET A MOTOR IN ALARM 

 

 

OPERATION WITH BAR 400 or 600 

 

 

OPERATION WITH FANS NOT TECSYSTEM                
 

………………………………….. 
 
…………………………………... 
 
…………………………………… 

— 

 

          — 
 
          —

 

7)   PROGRAMMING 

………………………………….. 11 

8)  WARRANTY CONDITIONS 

………………………………….. 12 

9)  TROUBLESHOOTING 

………………………………….. — 

10)  EQUIPMENT DISPOSAL 

………………………………….. — 

11)  USEFUL CONTACTS 

………………………………….. 13 

CONTENTS 

 

INTRODUCTION

 

2

 

 


background image

VRT200

 

 
 

 

 

 

 

 

 

 

                     ATTENTION:

 

 

Read the manual carefully before starting to use the control unit. Keep the instructions for future reference. 
 
 

                      Do not open the device, touching any internal components can cause electric shock. Contact with 230 Volts  
            AC  can be fatal. To reduce the risk of electric shock, do not dismantle the back of the device for any reason. Moreover  
           its opening would void the warranty. 
 

Before connecting the device to the power supply, make sure that all the connections are correct. 

Always         

disconnect the unit from the supply before any cabling modification.

 

                Any intervention on the equipment must be entrusted to a qualified repair engineer.

 

         Failure to comply with these instructions can cause damages, fires or electric shock, and possible serious injuries! 

 

POWER SUPPLY

 

 

The VRT200 series can be supplied by 230Vac 50/60Hz . 
Before using it, make sure the power cable is not damaged, kinked or pinched. Do not tamper with the power cable. Never 
disconnect the unit by pulling the cable, avoid touching the pins. Do not carry out any connecting/disconnecting with wet 
hands. To disconnect the device, do not use objects such as levers. Immediately disconnect the device if you smell burning 
or see any smoke: contact technical service.  

 

LIQUIDS

 

Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never touch 
with wet or humid hands during storms. If any liquid penetrates the control unit, disconnect it immediately and contact 
technical service. 

 
CLEANING 

Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, and 
compressed air. 

 
OBJECTS 

Never insert any objects into the cracks of the control unit. If this happens, disconnect the control unit and  
contact an engineer. 

 
USE RESERVED TO QUALIFIED PERSONNEL 

The purchased goods are a sophisticated electronic device that is totally unsuitable to be used by non-qualified personnel. 
Any intervention must be carried out by a specialist engineer. 

 
ACCESSORIES 

The use of non-original accessories or spare parts might damage the unit and endanger users' safety.  In the event of faults, 
contact technical service. 

 
LOCATION 

Install the control unit indoors, in a place protected from water splashes and sun rays. Do not place near heat sources 
exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations. Position the 
unit as far as possible from any intense magnetic fields. 

 
REPAIRS 

Do not open the control unit. For any fault, always use qualified personnel. The opening of the control unit and/or the removal 
of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all devices, any 
attempt to open the unit would break the seal and cause the consequent automatic forfeiture of the warranty. 

 
 

TECHNICAL INFORMATION  

 

Mail: ufficiotecnico@tecsystem.it — tel: 02/4581861

 

 SAFETY REQUIREMENTS 

3

 

 


background image

VRT200

 

 

 

 

 

 

The following objects are present inside the box: 

Control unit 

 
 
 
 
 
 
 
 

 

 

 

Start guide and QR CODE   

                                                                                                                                                     
 
 
 
 
 
 
 
 

2 blocks for panel mounting 

 
 
 

1

 

ENABLE contact terminal 2 poles pitch 5                      
Code: 2PL0363 - Screws tightening torque 0.5Nm 

 
 

 

2 Supply and relay terminal 3 poles pitch 5                          
Code: 2PL0367 - Screws tightening torque 0.5Nm 

 

1 PTC line connection terminal 3 poles  

 

 

1 motor line terminal 4 poles pitch 5                              

Code: 2PL0369 - Screws tightening torque 0.5Nm 

 
 
 

 
 

 

1MN0030 REV. 2 

ATTENTION: 

always install the device using the terminals included in the pack. The use of terminals other 

than those included with the control unit might cause malfunctions. 

ACCESSORIES 

 

4

 

 


background image

VRT200

 

 
 

 

 

 
 
 

 

 

TECHNICAL SPECIFICATIONS

 

VRT200

 

 

POWER SUPPLY

 

 

 

Supply rated values 

230 Vac ±10% 

(10 A max) 50/60 Hz 

 

INPUTS

 

 

 

1 contact enabling remote control (ENABLE) 

 

 

2 inputs for temperature control with PTC or AUX contact 

 

 

1 motor line supply input 250Vac max (10 A max) 50/60 Hz  

NO 

 

Connections on removable terminal strips 

 

 

OUTPUTS

 

 

 

1 fault sensor or operating failure (FAULT) relay 

SPDT

 

 

 

Output relay with 5A-250Vac-res COS

Ф

=1 contacts. 

 

 

2 M1-M2 outputs: 250Vac max ±10% 5A max 50/60Hz. 

SPST

 

 

 

DIMENSIONS

 

 

 

100x100 mm– din43700-depth 131mm (terminal block included) 

Hole 92 x 92 mm 

 

TEST AND PERFORMANCE

 

 

 

Construction in compliance with CE regulations 

 

 

Protection from electrical interference EN 61000-4-4 

 

5

 

 


background image

VRT200

 

 

 

 
 
 

 

 

TECHNICAL SPECIFICATIONS

 

           VRT200

 

 

 

TEST AND PERFORMANCE

 

 

 

 

Dielectric strength 1500 Vac for 1 minute: supply - relay fault, supply - remote. 

 

 

 

Ambient operating temperature from –20°C to +60°C 

 

 

 

Humidity 90% non-condensing 

 

 

 

Housing NORYL 94 _V0 

 

 

 

Absorption 5VA (max) 

 

 

 

Protection treatment of the electronic part 

Option 

 

 

Front polycarbonate IP65 

 

 

 

DISPLAY AND DATA MANAGEMENT

 

 

 

 

LED’s alarm: undercurrent, overcurrent, (overtemp-aux stop only on VRT200). 

 

 

 

LED’s running: remote, local 

 

 

 

LED’s prg setting, cal. 

 

 

 

Initial AUTO-TUNING to set up motors' operation 

 

 

 

Front button to START/STOP motors locally 

 

 

 

Front alarm RESET button 

 

 

 

Access to programming through front button 

 

 

 
 
 
 
 
 
 
 
 

6

 

 


background image

VRT200

 

 
 

 

 

 

 

 

 

 

 

 

1) 

Control unit series 

11) 

PRG/SET button: entering programming 
and going on to the following step 

2) 

Active (running) ventilation LED (green) 

12) 

Programming phase ON PRG LED (yellow) 

3) 

Overtemperature stop LED (red) (only 
VRT200) 

13) 

M1 motor in under-current LED (yellow) 

4) 

M2 motor in over-current LED (red) 

14) 

M1 motor in over-current LED (red) 

5) 

M2 motor in under-current LED (yellow) 

15) 

Current variation LED (yellow) 

6) 

Fixing block 

16) 

Fans' local management LED (red) 

7) 

Fans' local START/STOP button 

17) 

Fans' remote control LED (green) 

8) 

Fans' control mode REM/LOC button 
(REMOTE or LOCAL) 

18) 

Programming selection LED (yellow) 
(% In, d.start, d.trip) 

9) 

ENT/RESET button: alarm reset and 
programming data selection 

19) 

Monitoring delay LED (yellow) at start up 
d.start 

10)  Motors' auto-tuning phase LED (yellow) 

20) 

Trip delay LED (yellow) d.trip 

 

 

 

 

FRONT PANEL 

 

7

 

 


background image

VRT200

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Drill a 92 x 92 mm hole in the panel sheet. 

 
 

 
 
 
 
 
 
 
 
 
 

 
 

 

 
 
 
 
 
 
 
 

 

1MN0063 REV. 0 

 

1) Control 

unit 

2) 

Panel hole dimensions (+0.8mm tolerance) 

3) Identification 

label 

 

 

 

Fix the unit securely with the blocks supplied. 

 
 
 
 
 
 
 
 
 
 

1 2 

4  

 

1MN0008 REV. 0 

 

1) Control 

unit 

3)  Fixing 

screw 

2) 

Fixing block 

4) 

Crosshead screwdriver #1X100mm 

MOUNTING 

8

 

 


background image

VRT200

 

 
 

 

 

 

 

 

 

VRT200 

 

 
 
 
 
 
 
 
 

 

 
 

 

 
 
 
 
 

 

 
 
 
 
 
 

1MN0046 REV. 0 

 

 

1) 

AUX 1 - AUX 2 (COM) inputs fan 
temperature control PTC sensor connection 

4) 

Control unit and fan line supply 230V±10%
 50-60 Hz 10 Amp.max 

2) 

Remote enabling contact ENABLE 

5) 

FAULT relay (fault signal) 

3) 

M1-M2 motor line connection (5A max) 

 

 

 
 

Note: with the power to the unit ON, the FAULT relay switches, contacts 8-9 open (NO) and 7-9 closed (NC).

 

 
 
 
 

 

 

 

 

 
FAULT  8-9 NC: ALARM FAULT OR POWER OFF 

FAULT  7-9: NC POWER ON

 

 
 

ELECTRICAL CONNECTIONS 

7

   

8

   

9

 

7

   

8

   

9

 

9

 

 


background image

VRT200

 

 

 

POWER SUPPLY

 

 

The VRT200 control unit must be supplied with 230Vac 

±

10% 50/60Hz, check the connection diagrams on pages 9 

and 10. 

A variation in the network voltage of over 10% might cause alarms because of the current variation in the load. 

 

If the electrical system is affected by harmonic frequencies, alarm warnings might be triggered because of the 
consequent variation in the current absorbed by the motors. 

 

It is good practice to make sure that the level of system harmonics is not such as to cause malfunction or damages to 
all the connected electrical and electronic instruments, in compliance with the regulations in force for the type of 
system. 

 
 

OPERATION

 

 

When switched on, the device carries out a LAMP TEST and is set either in REMOTE or LOCAL mode, according to 
how it was set before being switched off. 

 

In REMOTE mode the fans are activated when contact 52-53 closes, which must be connected to the FAN contact of 
the temperature control unit. 

 

In LOCAL mode the fans are activated by pressing the <START-STOP> button. The status of operation is stored in 

case of power failure. 

 

HOW TO CHECK THE ALARM STATUS

 

 

 

Running LED OFF: 

no ventilation activation control 

 

Running LED ON: 

REMOTE or LOCAL ventilation activation 

 

Over- and under-current LEDs OFF: 

motor operating correctly 

 

Over-current LED ON: 

motor stopped due to over-current 

 

Under-current LED ON: 

motor working + under-current alarm signal 

 

Over- and under-current LEDs ON + overtemp aux stop: 

overtemperature alarm  

 

Under-current LED flashing: 

motor disconnected while auto-tuning 

 

Over-current LED ON: 

motor consumption >5.5A (immediate trip without any delay) 

 

All LEDs flashing: 

corrupted memory error (ech); press reset and repeat the programming procedure 

 

 

N.B.: 

A motor in a state of alarm or the interruption of supply to the device make contacts 8-9 of the FAULT relay close. 

 

 

HOW TO RESET A MOTOR IN ALARM

 

 

To reset an alarm due to under-current, over-current, overtemp-aux, press the RESET button after carrying out the 
necessary checks and any repairs might be required. 

 

             OPERATION WITH BAR 400 OR 600 

 

 

The 400 and 600 bars are fitted with low current variation motors in case of a motor block. 

To optimise the operation 

of the VRT200 control unit with these bars, we recommend the alarm threshold is programmed at 5%. 
 
 

             OPERATION WITH FANS NOT TECSYSTEM 

  

           The proper functioning of the VRT unit is guaranteed only for: fans with current absorption between 250mA  
           (IN MAX 20%) or 300mA (IN MAX 30%) and 5A , single phase, single speed and power variation is not  
           greater than ± 10%. 

 
 
 

                           IMPORTANT NOTE: if an existing control unit must be replaced with a new one, to guarantee  
           its correct and safe operation, all the connecting terminals must be replaced with the new terminals supplied, 
          on condition the brand of the new terminals is different from the one of the previously installed ones. 

10

 

 


background image

 


background image

VRT200

 

 

 

 

VRT200 

 

 

 

STEP

 

 

PRESS

 

 

EFFECT

 

 

PRESS

 

 

NOTES

 

 

 

 
 

 

 

 
 

Programming start

 

 

 
 

Keep pressing for 5 seconds until the ON PRG 

LED switches ON. 

 

 

 
 

 

 

 
 

Programming 

“%In”

 

 

 

Set the maximum current variation allowed as a 

percentage (5-10-20-30%) of the In. rated value. 

 

Default 5% 

 

 

 

 

Going to the 

"d.start"

 programming 

step 

 

          Start delay: fan start time during which no  

alarm is generated 

 

 

 
 

 

 

 

Selection of the time in 
seconds 

"d.start"

 

 

 

Select the desired time (5-10-20-

30 sec.) 

 

Default 5 

 

 

 

 

 

 

Going to the 

"d.trip"

 programming 

step 

 

 

Trip delay: time during which the 

alarm persists, necessary for signalling 

 

 

 
 

 

 

 

Selection of the time in seconds  

“d.trip”

 

 

 

Select the desired time (5-10-20-

30 sec.) 

 

Default 5 

 

 

 
 
 

 

 

VRT200

 

Going to the 

“OVERTEMP-AUX 

STOP”

 programming step 

 

 

 

By enabling this function it is possible to connect 

a PTC (or series of PTCs) to control the motor 

temperature. AUX1 for the M1 line 

and AUX2 for the M2 line 

 

 

 
 
 

 

 

 

VRT200

 

Enabling or disabling 

PTC

 inputs. 

 

 

LEDS 

 ON: PTCs enabled 

LEDs 

 ON: PTC disabled 

N.B.: if the PTC sensors are not 

connected, the function must be disabled. 

 

Default disabled 

 

 

 
 
 
 

 

 

 
 
 

 

Motor start 

for automatic calibration CAL LED 

ON 

 

 

To perform the "automatic calibration" all motors 

must be connected as per final configuration. 

At the START the motors are 

switched ON for 60 seconds, the 

CAL LED flashes and LEDs 0-5-10-

20-30 light up in sequence. 

When the calibration is completed, the 

control unit resets and goes  

into REMOTE mode 

 

 

N.B.: any connection or programming errors might cause fan malfunctions. 

 

 
                ATTENTION:  
 

We recommend you check the control unit before starting the device. 
  
The default parameters set by TECSYSTEM might not suit your requirements.    
  
Programming the device is the end user’s responsibility: the set alarm thresholds and the enabled 
functions described in this manual must be checked (by a specialized technician) referring them to the 
application and system characteristics on which the control unit is installed. 

PROGRAMMING  

11

 

 


background image

VRT200

 
 

 

 

 

 

 
            The Product purchased is covered by the manufacturer's or seller's warranty at the terms and conditions set forth in  
             the "Tecsystem s.r.l's General Conditions of Sale", available at www.tecsystem.it and / or in the purchase agreement.  
             The warranty is considered valid only when the product is damaged by causes attributable to TECSYSTEM  
             srl, such as manufacturing or components defects.  
             The warranty is invalid if the Product proves to have been tampered with / modified, incorrectly  connected,  
             because of voltages  outside the limits, non-compliance with the assembly and use technical data, as described in  
             this instruction manual.  
             The warranty is always ex Corsico as stated in the "General Conditions of Sale". 

 

 

TROUBLESHOOTING 

CAUSES AND SOLUTIONS

 

 

 

 

The control unit does not switch on and the 
supply to terminals 40-42 is correct. 

Check that: the connector is correctly inserted into its housing, the 
wires are tightened, there is no evidence of burning on the 
connectors.  Disconnect the power supply, carry out the above and 
reconnect. 

 

 

 

M1 or M2 over-current red LED ON 

 

Check the condition of the fans and replace any faulty ones. Re-
program the device. 

 

 

 

M1 or M2 under-current yellow LED ON 

 

Check the condition of the fans, the cables and the supply. Re-
program the device. 

 

 

 

All the LEDs are flashing 

 

Memory error, press RESET and repeat the programming 
procedure. 

 

 

 

All the LEDs are ON 

 

Likely microcontroller fault, return the device to Tecsystem for repair.

 
 

 

Contact 

TECSYSTEM Technical Department if the problem persists.  

 

 

 

 

 

 

European directives 2012/19/EC (WEEE) and 2011/65/EC (RoHS) have been approved to reduce electrical and 
electronic waste and promote the recycling and reuse of the materials and components of this equipment, cutting down 
on the disposal of the residues and harmful components of electrical and electronic materials. 

 

All the electrical and electronic equipment supplied after 13 August 2005 is marked with this symbol, pursuant 
to the European directive 2002/96/EEC on electrical and electronic waste (WEEE). Any electrical or electronic 
equipment marked with this symbol must be disposed of separately from normal domestic waste. 

 

Returning used electrical devices: contact TECSYSTEM or the TECSYSTEM agent for information on the correct 
disposal of the devices. 

 

TECSYSTEM is aware of the impact its products have on the environment and asks its customers active support in the 
correct and environmentally-friendly disposal of its devices. 

EQUIPMENT DISPOSAL  

WARRANTY CONDITIONS  

12

 

 


background image

VRT200

 

 

 
 

 

 

  

  

 

 

USEFUL CONTACTS  

TECHNICAL INFORMATION 

: ufficiotecnico@tecsystem.it 

  

SALES INFORMATION 

: info@tecsystem.it   

  

  

13