“Translations of the original instructions”

 

 

ENGLISH 

  

 

TECSYSTEM S.r.l.

 

20094 Corsico (MI) 

Tel.: +39-024581861 

Fax: +39-0248600783 

           T119  

INSTRUCTION MANUAL 

1MN0110 REV. 0 

 

 


background image

T119

 

 

 

 
 
 

 

 

 
 
 
 
 
 
 

 

 
 

 

  

PAGE 

1)   SAFETY REQUIREMENTS 

………....................................... 

2)   ACCESSORIES 

………………………………….. 

3)   TECHNICAL SPECIFICATIONS 

………………………………….. 

4)   INTRODUCTION 

………………………………….. 

5)   FRONT  

………………………………….. 

6)   INSTALLATION 

………………………………….. 

— 

 

POWER SUPPLY 

………………………………….. 

7)   PROGRAMMING  

………………………………….. 

— 

 

ALARM RELAY TEST 

………………………………….. 

 

LED TEST 

………………………………….. 

— 

 

ALARM 1 RELAY OPERATION 

 …………………………………. 

— 

 

ALARM 2 RELAY OPERATION 

………………………………….. 

— 

 

FAN RELAY OPERATION 

 

 (VENTILATION) 

………………………………….. 

— 

 

DELAYED VENTILATION CYCLE (DELAY OFF) 

………………………………….. 

— 

 

SENSOR DIAGNOSTIC DEVICE 

………………………………….. 

10 

 

PTC SENSOR FAULT 

………………………………….. 

— 

 

PTC SENSOR FAULT DIAGNOSIS 

………………………………….. 

— 

 

"PTC" TYPE TEMPERATURE SENSORS 

………………………………….. 

— 

 

PTC TECHNICAL SPECIFICATIONS 

………………………………….. 

11 

 

PTC RESISTANCE VALUES ALLOWED FOR 
CONNECTION TO T119 

………………………………….. 

— 

8)   SENSOR / RELAY ELECTRICAL CONNECTIONS 

………………………………….. 

12 

9)   WARRANTY CONDITIONS 

………………………………….. 

13 

10)   TROUBLESHOOTING 

………………………………….. 

— 

11)   EQUIPMENT DISPOSAL 

………………………………….. 

— 

12)   USEFUL CONTACTS 

………………………………….. 

— 

 
 
 

 

CONTENTS

 

 

INTRODUCTION 

First of all we  wish to thank you for choosing to use a 

TECSYSTEM

 product and recommend you read this instruction 

manual  carefully:  You  will  understand  the  use  of  the  equipment  and  therefore  be  able  to  take  advantage  of  all  its 
functions. 

  

ATTENTION! THIS MANUAL IS VALID AND COMPLETE FOR THE T119 CONTROL UNIT 

 

 


background image

T119

 

 

 
 

 

 

 

 
    

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SAFETY REQUIREMENTS 

                 
    ATTENTION :  

  
  

 
Read the manual carefully before starting to use the control unit. Keep the instructions for future reference.  
  
 
                Do not open the device, touching any internal components can cause electric shock. Contact with 50 Volts can 
be  fatal.  To  reduce  the  risk  of  electric  shock,  do  not  dismantle  the  back  of  the  device  for  any  reason.  Moreover  its 
opening would void the warranty.   
  

Before  connecting  the  device  to  the  power  supply,  make  sure  that  all  the  connections  are  correct. 

Always 

disconnect the unit from the supply before any cabling modification. 
  
                Any work on the equipment must be entrusted to a qualified engineer. 
  

Failure  to  comply  with  these  instructions  can  cause  damages,  fires  or  electric  shock,  and  possible  serious 
injuries! 

  
  

POWER SUPPLY

 

The  T119  control  unit  has  UNIVERSAL  power  supply,  i.e.  it  can  be  supplied  by  24  to  240  Vac-Vdc,  irrespectively  of 
polarity in Vdc. 
Before  using  it,  make  sure  the  power  cable  is  not  damaged,  knotted  or  pinched.  Do  not  tamper  with  the  power  cable. 
Never  disconnect  the  unit  by  pulling  the  cable,  avoid  touching  the  pins.  Do  not  carry  out  any  connecting/disconnecting 
with  wet hands. To disconnect the device, do not use objects such as levers. Immediately disconnect the device if you 
smell burning or see any smoke: contact technical service. 

  

LIQUIDS   

 

Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never 
touch  with  wet  or  humid  hands  during  storms.  If  any  liquid  penetrates  the  control  unit,  disconnect  it  immediately  and 
contact technical service.   

  

CLEANING

 

Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, 
and compressed air. 

  

OBJECTS

 

Never  insert  any  objects  into  the  cracks  of  the  control  unit.  If  this  happens,  disconnect  the  control  unit  and  contact  an 
engineer.  

  

USE RESERVED TO QUALIFIED PERSONNEL

 

The  purchased  goods  are  a  sophisticated  electronic  device  that  is  totally  unsuitable  to  be  used  by  non-qualified 
personnel. Any work must be carried out by a specialist engineer.  

  

ACCESSORIES

 

The  use  of  non-original  accessories  or  spare  parts  can  damage  the  unit  and  endanger  users'  safety.    In  the  event  of 
faults, contact technical service. 

  

LOCATION 

Install the control unit indoors, in a place protected from water splashes and sun rays. Do not place near heat sources 
exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations. Position 
the unit as far as possible from any intense magnetic fields. 

  

REPAIRS

 

Do  not  open  the  control  unit.  For  any  fault,  always  use  qualified  personnel.  The  opening  of  the  control  unit  and/or  the 
removal of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all 
devices,  any  attempt  to  open  the  unit  would  break  the  seal  and  cause  the  consequent  automatic  forfeiture  of  the 
warranty. 

  
 

TECHNICAL INFORMATION 

  

Mail: ufficiotecnico@tecsystem.it 

— tel: 02/4581861  

 

 


background image

T119

 

 

 

 

 

 

 

       The following objects are present inside the box: 

 
 

Control unit 

 

Start guide and QR code                                                                      

 

1 supply terminal 3 poles pitch 5  
   Code: 2PL0367 - Screws tightening torque 0.5Nm 

 

1 PTC sensor terminal 4 poles pitch 5 
   Code: 2PL0369 - Screws tightening torque 0.5Nm 

 

1 relay terminal 8 poles pitch 5  
   Code: 2PL0374 - Screws tightening torque 0.5Nm 

 

 
 

 
 

ACCESSORIES 

  

 

ATTENTION: always install the device using the terminals included in the pack.                
The use of terminals other than those included with the control unit might cause malfunctions. 

 

1MN0030 REV. 0 

 


background image

T119

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TECHNICAL SPECIFICATIONS  

 

T119

 

POWER SUPPLY  

 

  

Supply rated values  

24 -240Vac-dc 

50/60HZ 

Maximum ratings 20-270 Vac-dc

 

 

● 

 

Vdc with reversible polarities 

 

● 

INPUTS  

 
 

3 series of PTC inputs 

 

            

 

1 series for L1 (ALARM) 

 

● 

1 series for L2 (TRIP) 

 

● 

1 series for FAN 

 

● 

Connections on removable terminal strips

 

 

● 

Input channels protected against electromagnetic interference 

 

● 

OUTPUTS  

 
 

 

2 alarm relay (ALL1 / FAULT AND ALL2) SPDT

 

 

● 

1 ventilation management relay (FAN) with timed latch (5-10-20-40 min.) delay OFF SPST 

 

● 

Output relays with 5A-250Vac-res 

COSФ=1 contacts.

 

 

● 

DIMENSIONS

 

 
 

48x96mm

– DIN43700-depth 150mm (terminal block included) 

 

panel cut-out   

44 x 92 mm 

TESTS AND PERFORMANCE

 

 

● 

Assembly in compliance with EC rules

 

 

● 

Protection from electrical interference EN 61000-4-4  

 

● 

Dielectric strength 1500 Vac for a min. between output relays and sensors, relays and power supply, 
power supply and sensors 

 

● 

Ambient operating temperature from -20°C to + 60°C  

 

● 

 

Humidity 90% non-condensing

 

 

● 

Self-extinguishing PPO UL94VO 

 

● 

 

 


background image

T119

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

INTRODUCTION 

  

 

TECHNICAL SPECIFICATIONS  

 

T119

 

Absorption 2VA 

 

● 

Self-diagnostic circuit 

 

● 

Protection treatment of the electronic part

 

 

Option 

DATA DISPLAY AND MANAGEMENT 

 
 

LED indicating alarm channel, trip or fan 

 

● 

LED indicating FAULT 

 

● 

2 alarm thresholds 

 

● 

1 ventilation ON control threshold 

 

● 

Access to programming through keyboard 

 

● 

Automatic exit from programming after 1 minute's inactivity 

 

● 

 

The T119 is the most advanced unit on the market as regards temperature monitoring units for MV cast resin transformers 
which utilize PTC sensors.  
 
The unit gives the ALL1 pre-alarm and TRIP signals when the temperature limits detected by the PTCs in the windings are 
reached. 
 
The T119 is arranged to control the cooling ventilation of the transformer. The unit controls continuously the efficiency of 
the PTC sensors and when one of these is defective, you have immediately a faulty sensor warning. 
 
The FAN relay is energized so long as the temperature T° is higher than the 

NAT value; when T° gets below this value, 

the relay is still energized for the set ventilation time (5-10-20-

40’) (DELAY OFF function). 

 
As the PTCs currently produced by the various European manufacturers have different specifications, Tecsystem Srl is not 
responsible for the control system malfunctioning due to PTCs with resistance values other than those indicated in 

table 1 

(page 11). 

  
 

LED SIGNAL:   
 
LED ON

"ON" 

The device is powered correctly,  

"OFF" 

The device is not powered correctly 

L1 LED: 
 "ON" 

L1

 

trip threshold exceeded,

 "OFF" 

temperature below the L1 trip threshold. 

 

L2 LED:  
 "ON"

 L2 trip threshold exceeded,

 "OFF" 

temperature below the L2 trip threshold.

 

FAN LED:  
 "ON"

 FAN trip threshold exceeded,

 "OFF" 

temperature below the FAN trip threshold.

 

 
FAULT LED - L1 LED - L2 LED - FAN LED

 flashing, see

 

PTC SENSOR FAULT DIAGNOSIS on page 10. 

 

 


background image

T119

 

 

 

 

 FRONT  
  
  

1)  

Control unit series  

5) 

FAN (ventilation) LED (red) 

2) 

Power ON LED (green)  

6) 

FAULT LED (yellow) 

3) 

ALL1 (alarm) LED (red) 

7) 

PRG (programming) LED (red) 

4) 

ALL2 (trip) LED (red) 

8) 

TEST button 

 

1MN0110 REV. 0 

 MOUNTING 
  
  

1) 

Control unit  

3) 

Fixing screw 

2) 

Fixing block 

4) 

Crosshead screwdriver #1X100mm 

 

Make a 92 x 44mm hole (tolerance +0.8mm) in the 
panel metal sheet.  

  
 

1MN0111 REV. 0 

1MN0064 REV. 0 

 


background image

T119

 

 

 

 

 
 

 
 

 

POWER SUPPLY 

  

 
The T119 control unit has UNIVERSAL power supply, i.e. it can be supplied by 24 to 240 Vac-Vdc, 50/60Hz irrespectively of 
polarity in Vdc (terminals 40-42).  

  

This  is  obtained  thanks  to  the  use  of  a  tested  power  supply  unit,  newly  designed  and  manufactured,  that  frees  installers 
from worrying about the correct Vac and Vdc supply. 

 
 
 

 

The ground must always be connected to terminal 41. 

  

When  the  unit  is  supplied  directly  by  the  secondary  of  the  transformer  to  protect,  it  can  be  burnt  out  by  strong 
overvoltages. 
This happens if the main switch is closed and the transformer has no load (blank test). 
The  above-mentioned  problems  are  much  more  evident  when  the  220  Vac  voltage  is  taken  directly  from  the  transformer 
secondary bars and there is a fixed capacitor battery to phase the transformer itself. 

  
 

If  an  existing  control  unit  must  be  replaced  with  a  new  one,  to  guarantee  its  correct  and  safe  operation,  the 
sensor/relay/supply connecting terminals must be replaced with the new terminals supplied. 

  

 

To  protect  the  control  unit  from  line  overvoltages,  we  suggest  using  the  PT-73-220  electronic  discharger,  designed  by 
TECSYSTEM S.r.l. for this specific purpose.  As an alternative we suggest using 110 Vac or, even better, 110 Vdc supply 
voltages. 

  
 

 PROGRAMMING  
  
  

STEP 

ACTION 

 

EFFECT

 

 

1

 

Turn on the unit 

 

the green LED lights up

 

 

2

 

Push TEST twice in sequence

 

 

the PRG LED flashes

 

 

3

 

Push  TEST  within  5"  until  the  PRG  LED  is  steady 
ON 

 

 

the PRG LED is ON continuously

 

 

4

 

Push TEST within 5" to select the desired FAN time

 

 

the red LED switches from T1-T2-T3-
T4 
(FAN time 

5’-10’-20’-40’)

 

 

5

 

Stop  pressing  TEST  when  the  LED  is  on  the  Tx 
corresponding  to  the  desired  time.  Wait  for  all  the 
LEDs to go OFF.

 

 

  

 

6

 

End of programming

 

 

all the LEDs are OFF

 

 

Turn the unit OFF and then back ON 

 

 

  

 

VENTILATION CYCLE PROGRAMMING  

  
  
 

To choose the FAN time (point 4): 
  
Press TEST once to select 

5'

 (T1 ON) 

Press TEST twice to select 

10'

 (T2 ON) 

Press TEST three times to select 

20'

 (T3 ON) 

Press TEST four times to select 

40'

 (T4 ON) 

If  no  ventilation  cycle  is  required, 

press  TEST  5  times  (all  LEDs  are  OFF).  The  control  unit  is  programmed  only  for 

ALL1 and All2 (alarm and tripping) 

  
 

 


background image

T119

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

               IMPORTANT WARNING

 

  

Before carrying out the isolation test of the electrical panel the control unit is installed on, disconnect it together 
with the sensors from the power supply, to prevent it from being seriously damaged.

 

  
 

ALARM RELAY TEST 

 

STEP 

ACTION 

 

EFFECT

 

 

1

 

 
push TEST three times in sequence 
 

 

the  T1,2,3,4  LEDs  light  up  in 
sequence

 

 

2

 

 
Within 

5” push TEST without releasing it until the 

LEDs light up all together 

 

 

LEDs T1,2,3,4 flash all together

 

 

3

 

 
after 

5” the FAN  relay lights up, followed by the 

ALL1 and ALL2 relays 

 

 

FAN-ALL1-ALL2  LEDs and relays 
are ON

 

 

4

 

 
END OF THE TEST CYCLE 

 

 

all the red LEDs go OFF

 

 

 

DELAYED VENTILATION CYCLE (DELAY OFF)

 

  
   

 
STEP

 

 

ACTION

 

 

EFFECT 

 

 

1

 

the FAN PTC sensor is ON 

the FAN relay is ON and the red LED is lit

 

 

2

 

the  temperature  goes  below  the  PTC 
value

 

the FAN relay remains ON for the set time and 
the red LED flashes

 

 

3

 

the  temperature  raises  again  above  the 
PTC set threshold

 

the LED is ON all the time

 

 

 

 
 
LED TEST  

  

We suggest carrying out the control unit LED test regularly. 
For this operation, press the TEST key briefly; all the LEDs light up for 2 seconds.

 

If one of the LEDs does not work, please return the control unit to TECSYSTEM for repair.  
 
ALARM 1 RELAY OPERATION 

  
The ALL1 (L1) relay operates normally when the unit is powered, therefore the N.O. contact is closed. In case of an alarm 
on the ALL1 (L1) PTC or a fault in the control unit itself, the relay gets de-energised with consequent closing of the N.C. 
contact. 
 
The ALL1 (L1) relay also has the same function as the PTC sensor FAULT. If this relay is triggered when the PTC sensor 
FAULT LED is FLASHING, it means that there is an error in the reading of a PTC sensor. It is possible to find it, thanks to 
a second LED flashing which corresponds to the fault channel.  

  

ALARM 2 RELAY OPERATION 
  

The ALL2 (L2) relay is normally de-energized and energizes when there is an alarm on the L2 PTC. 
  

FAN RELAY OPERATION (VENTILATION) 
  

During programming, it is possible to set the cooling time or to exclude the FAN option. If the FAN is excluded, the relay 
doesn’t energize and for this reason it is possible not to install the corresponding PTC. 
 
If the FAN is set up, the relay activates when the relative PTC sends the first signal and the FAN LED is steady ON: the 
relay is active for as long as the PTC senses the temperature is normal, the T119 unit keeps the relay ON for the time set 
during programming and the FAN LED flashes.  
 
 When the time expires and if the temperature is still normal, the relay de-energizes and the LED switches OFF. 
  

  
  
 

 


background image

10 

T119

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

"PTC" TYPE TEMPERATURE SENSORS 
 

The PTCs can be compared to bimetallic thermostats where the contact opens and closes at the approximate temperature, 
defined as their operating characteristic (

NAT=operating temperature). 

 
The  sensor  is  calibrated  for  one  temperature  only  that  can  vary  from  60°C to  190°C,  in  10°C  (In  relation  to  the  acquired 
probe), in 10°C steps (60-70-80-90-100-110-120-130-140-145-150-155-160-170-180-190). 
 
The PTCs are electronic thermometric sensors made with a chemical mixture that vary their electrical resistance according 
to the recorded temperature. 
 
There is a 

NAT (operating temperature) for the PTCs as well as for the bimetallic thermostats. 

The  PTCs  do  not  allow  precision  adjustments  since  the  characteristic  resistance  values  are  fixed  at 

–5°C  and  +5°K  of 

NAT. 

 
The PTC characteristic resistance values are set by the DIN 44081 and 44082 standards. 
 
Since the PTC resistance curve is very rapid, in the section between 

NAT -5°C and

NAT +5°K

it is quite difficult to make 

adjustments in a temperature span of less than +/- 5°K.  

  
  
 

PTC SENSOR FAULT  

 

 

ACTION

 

 

EFFECT

 

 

one of the PTCs is short-circuited

 

the FLT yellow LED and the corresponding LED 
(ALL1-ALL2-FAN) are flashing

 

 

replace or repair the PTC

 

the LEDs go OFF

 

 

 

            ATTENTION  
 

If the right model of PTC is not connected to the T119 control unit, the LEDs flash. 
The PTC temperature is 

nat + T = 1300

 

ohm.

 

  
 

This new function allows enabling or disabling the PTC diagnostic device (Foc and Fcc): 
  

Diagnostics disabling method: 

power the instrument keeping the TEST button pressed until the FAULT LED comes ON 
 
With the diagnostics 

disabled

, the FAULT yellow LED will be ON all the time.

 

 

  

Diagnostics re-enabling method 

Power the instrument keeping the TEST button pressed until all LEDs go OFF. With the diagnostics 

enabled

, the FAULT 

yellow LED will be OFF and flash in case of sensor faults. 
  
The T119 control units will be supplied with the sensor diagnostics 

ENABLED. 

  

  
 

SENSOR DIAGNOSTIC DEVICE 

 

  
 

PTC SENSOR FAULT DIAGNOSIS 
  

If one of the PTCs is short-circuited or interrupted, you have the following indications: 
 
alarm PTC 

ALL1(L1)   

the FAULT + ALL1 LED is flashing 

TRIP PTC 

ALL2(L2)   

the FAULT + ALL2 LED is flashing 

FAN PTC  

FAN 

 

the FAULT +FAN LED is flashing 

 

 


background image

11 

T119

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

Table 1 

TEMPERATURE

 

RESISTANCE 

 

MEASURED VDC VOLTAGE

 

From 

–20 to dNAT-20°K 

From 20 to 250 

  

 2,5

 

From dNAT 

–5°K 

 

 550 

  

 2,5

 

From dNAT +5°K 

  

1330 

  

 2,5

 

From dNAT +15°K 

  

4000 

 

 7.5 pulsed 

Electric stiffness 

 

2500 Vac 

Maximum operating voltage 

 

30 

 

PTC TECHNICAL SPECIFICATIONS 

 

PTC RESISTANCE VALUES ALLOWED FOR CONNECTION TO T119 

 

The resistance value shown in table 1 refers to a single or multiple series of PTCs. 
 
The device operates correctly if the stated resistance values are complied with. If the PTCs, either single or multiple in 
series, have resistance values other than the stated, please notify TECSYSTEM Srl.  
 

 

FUNCTION 

 

RESISTANCE W 

 

NO ALARM 

Temperature of the machine below the alarm 

thresholds 

 

HIGHER THAN 50 

Ω 

 

ALARM 

FAN-ALL-TRIP set alarm thresholds reached 

 

HIGHER THAN 1800 

Ω 

 

FOC 

Sensor diagnostics interrupted 

 

HIGHER THAN 10 

KΩ 

 

 

FCC 

Sensor diagnostics short-circuited 

 

LOWER THAN 30 

Ω 

 

 

 


background image

12 

T119

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SENSOR / RELAY ELECTRICAL CONNECTIONS

 

PTC SENSORS  

 

RELAYS  

 

The L1/ FAULT relay operates normally when the unit is powered, therefore contact 5-7 is closed. The above picture 
shows the state of the relays in non-alarm condition.  
 

 

AL

ARM / FAULT  

AUDIO AND  
VISUAL INDICATION   

1)  

Universal unit supply 24-240 Vac-dc 50/60Hz   

3) 

L1 - L2 - FAN PTC sensor lines 

2) 

Relays (L1/FAULT-L2-FAN) 

 

 

 

1MN0110 REV. 0 

CH1 
  
CH2 
  
CH3 
  

L1      L2     FAN     COM 

1MN0095 REV. 0 

STOP  
SYSTEM 

L1                         L2                  FAN 

 

 


background image

13 

T119

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
         
 
 
 
 
                                                                                                      
 
 
 
                                                                                                       
 

              
       

 

TROUBLESHOOTING 

 

CAUSES AND 

SOLUTIONS

 

The  control  unit  does  not  switch  on,  the 
corresponding LED is OFF. 

Switch  the  unit  off  and  check  that:  the  connecting  wires  are 
tightened and there are no obvious burns on the connectors. 

One of the two PTC lines is in FAULT alarm 

Check  the  continuity  and  connection  of  the  relative  PTC  line.  
Replace the faulty sensor, see PTC sensor fault diagnosis on page 
10. 

FCD FUNCTION 

 

The Product purchased is covered by the manufacturer's or seller's warranty at the terms and conditions set forth in the 

"Tecsystem s.r.l's General Conditions of Sale", available at www.tecsystem.it, and / or in the purchase agreement. 

 

The  warranty  is  considered  valid only  when  the  product  is  damaged  by  causes  attributable  to TECSYSTEM  srl, such  as 
manufacturing or components defects.  
The warranty is invalid if the Product proves to have been tampered with / modified or incorrectly connected and causing 
voltages  outside  the  set  limits  and  does  not  comply  with  the  technical  data  for  use  and  assembly,  as  described  in  this 
instruction manual.  
The warranty is always ex Corsico as stated in the "General Conditions of Sale". 

Tecsystem  Srl  is  not  responsible  for  damages  caused  by  the  monitoring  unit  due  to  PTC  sensors  which  do  not 

have the resistance features DIN44081 and 44082 standards. 

N.B.

 To verify the correct operation of the monitoring unit in all its functions, we suggest you use the SIM-PTC simulator. 

 
 

European  directives  2012/19/EC  (WEEE)  and  2011/65/EC  (RoHS)  have  been  approved  to  reduce  electrical  and 
electronic waste and promote the recycling and reuse of the materials and components of said equipment, cutting down 
on the disposal of the residues and harmful components of electrical and electronic materials. 
   

All the electrical and electronic equipment supplied after 13 August 2005 is marked with this symbol, pursuant to 
European  directive  2002/96/EEC  on  electrical  and  electronic  waste  (WEEE).  Any  electrical  or  electronic 
equipment marked with this symbol must be disposed of separately from normal domestic waste. 

  
Returning  used  electrical  devices:  contact  TECSYSTEM  or  your  TECSYSTEM  agent  for  information  on  the  correct 
disposal of the devices. 
  
TECSYSTEM is aware of the impact its products have on the environment and asks its customers active support in the 
correct and environmentally-friendly disposal of its devices. 

  
 

TECHNICAL INFORMATION 

:  ufficiotecnico@tecsystem.it 

  

COMMERCIAL INFORMATION 

: info@tecsystem.it   

  

  
  
  
 

WARRANTY CONDITIONS 

EQUIPMENT DISPOSAL 

USEFUL CONTACTS