Full Text Searchable PDF User Manual

TIMER
VOLUME
Speaker
Speaker
OUTPUT
OUTPUT
CHIME
OFF
ALARM
CHIME
OFF
ALARM
DC 9~15V
DC 9~15V
Twin Plugs
Shelter Cable Wire
Front View
Infrared Beam
To Sensor
Photoelectric
Beam Sensor
Reflector
Max 6m
Siren Back View
SPK-200
Slide Switch: Chime / Off / Alarm
Timer Adjuster: 30 Seconds, Max.
Volume Adjuster: 0 ~Max
Adapter DC12V
INPUT
INPUT
Master Speaker(A)
Extending Speaker(B)
Optional
Manual of Door Entry Alarm & Counting System
P1
Item No.: DES-700 / DC-500
Applications
Specification
Connection Diagram 1
Features
Garage Door
Overhead Door
Entrance
Super Market, Restaurant, Warehouse
Retro-Reflection Type
Sensing Range: 0.5~6 meters (18 feet)
Volume Of Speaker: adjustable
Sounding Time: 3~30 seconds adjustable
DES-700 Including
: Sensor / Reflector / Speaker / Adapter / Mounting bracket / screw / Manual and
Mini screwdriver for speaker
Sensing Type
Response time of Speaker
Mounting Bracket and Screw
Sensing Range
Input Voltage
Consumption Current
Standby Current
Light Source
Ambient Temperature
Volume of Speaker
Alarm Time
External Chime Output
Speaker Output
Retro-Reflection Type Door Entry Alarm System
0.5~6 meters ( 18 feet)
DC 9~15V
130mA
25 mA max.
IR LED
-20
~50
(-4
~122
)
Chime: 1 sec. Alarm: 30 sec.
0~max. (Adjustable)
30 sec max. (Adjustable)
NPN Output
Chime / Off / Alarm (Selected by Slide Switch)
Included

P2
Connection Diagram 2
Connection Diagram 3
Standard Installation
TIMER
VOLUME
Speaker
OUTPUT
CHIME
OFF
ALARM
DC 9~15V
Twin Plugs
Shelter Cable Wire
Front View
Infrared Beam
To Sensor
Photoelectric
Beam Sensor
Reflector
Max 6m
Siren Back View
SPK-200
Slide Switch: Chime / Off / Alarm
Timer Adjuster: 30 Seconds, Max.
Volume Adjuster: 0 ~Max
Counter
(
Optional
)
Adapter DC12V
INPUT
WALL
1
2
3
INPUT
OUTPUT
CHIME
OFF
ALARM
DC 9~15V
INPUT
4 Digits Counter
Front Vew
(Optional)
Master Speaker
Front Vew
POWER LED
INDICATOR
Manual of Door Entry Alarm & Counting System
DC-500
DC-500

1. Please check that the speaker is switched to the
"Chime" or "Alarm" position. (Off=Silent)
2. Please check that the timer and volume
potentiometers are NOT in their min. Position.
3. The red LED will illuminate when the beam is
properly aligned, if the LED is not on please realign
the beam.
4. The reflector should be mounted a minimum of 50
cm from the sensor otherwise it will be impossible to
align the beam properly.
5. Make sure the plug of AC/DC adaptor is inserted
into the DC9~15V socket of the speaker
6. Make sure the infrared sensor is plugged into the
"INPUT"of the speaker and not the "OUTPUT"
7. If you have purchased the 4 digits counter
(optional), it should be connected to the "OUTPUT"
of the speaker via the included 10 m cable
8. Please use the attached screwdriver in the inner
box, Don't use any other size.
TIMER
TIMER
VOLUME
VOLUME
CHIME
CHIME
OFF
OFF
ALARM
ALARM
OUTPUT
OFF
Silent
OFF
Silent
CHIME
ALARM
CHIME
OFF
ALARM
OUTPUT
OUTPUT
Photoelectric
Beam Sensor
Reflector
50cm(20") Min
(
)
(
)
DC 9~15V
INPUT
DC 9~15V
INPUT
DC 9~15V
INPUT
DC 9~15V
INPUT
1
2
3
4
5
6
7
8
Trouble Shooting Guide