Pulse Evo 

High Security Lock for Safes & Vaults 

 

 

 

 

 

 

 

 

 

User Operating Instructions 

Standard Specification 

With additional instruction for Dual Mode, Alarm Signals & Dallas Keys 

 

 

 

 

 

 


background image

Available users and default codes 

 

User 

User ID 

Default Code 

Manager 

N/A 

1-2-3-4-5-6 

Users 1-8 

1-8 

Deleted 

–  Must  be  added  by 

the Manager 

User 9 
 

Deleted 

–  Must  be  added  by 

the  Manager.  User  9  is  the 
time delay override user. 

 

Default codes must be changed immediately.  All codes 
contain 6 digits. 

 

Acoustic and visual signals 

 
The lock system will indicate status with beeps and LED 
flashes on the keypad. 

 

Signal 

Indication 

Short beep & LED flash 

Button pressed correctly 

Double beep & LED flash 

Code or function entered 
correctly 

Long beep 

Code or function entered 
incorrectly 
Remote blocking is active 

LED flash every 2 seconds 

The lock is in time delay 

LED flash every second 
and beep every other 
second 

The lock is in the open window 

LED flash every 10 
seconds 

The lock is in penalty 

3 short beeps every 3 
seconds at opening 

Low battery warning 

 

Command Keys 

 

All  of  the  functions  available  to the  manager  and  users 
are  accessible  using  command  keys.  To  use  a 
command  key,  press  and  hold  the  relevant  command 
key until a double beep has sounded and the LED stays 
on,  enter  a  valid  code  then  follow  the  remaining 
instruction. 

 

Key 

Function 

Change Code 

Add a user  

Disable all users / enable all users 

Delete a user 

Test the keypad buttons 

Audit user status / download audit 

Enter time delay values 

 
 

Codes & Users 

 
 

The manager code holder can:

 

  Open the lock 

  Add, enable/disable and 

delete users 

  Change code 

  Audit the lock 

  Set time delay values 

 

There are 8 user codes numbered 1-8. Users can: 

  Open the lock 

  Change code 

 

There is 1 user code numbered 9. User 9 can: 

  Open the lock if time delay 

has been started by another 
user 

  Open the lock if time delay is 

not active 

  Change code 

 

To open the lock 

 

  Enter a valid 6 digit code. Within 4 seconds, turn the 

safe handle and/or turn the keypad. 

 

To close the lock 

 

  Turn the safe handle and/or turn the keypad. 

 

To open the lock when time delay is active 

 

  Enter  a  valid  6  digit  code.  Wait  for  the  time  delay 

period to elapse. 

The  open  window  will  be  indicated  with  an  LED  flash 
every second, and beep every other second. 

  Enter a valid 6 digit code. Within 4 seconds, turn the 

safe handle and/or turn the keypad. 

 

If  user  9  is  installed,  the  user  is  able  to  override  time 
delay started by another user. 

 

To change code 

 

Codes  should  always  be  changed  and  tested  with  the 
safe  or  vault  door  open,  with  the  bolt  in  the  locked 
position. 

  Press and hold 0 until a double beep sounds 

  Enter the old code, a double beep will sound 

  Enter the new code, a double beep will sound 

  Enter the new code again to confirm, a double beep 

will sound 

 

Test that the new code works whilst the door is open. 

 

To test the keypad 

 

If a key does not sound or if correct codes appear to be 
invalid, a keypad test can be undertaken. 

  Press and hold 5 until a double beep sounds 

  Press each number key in turn.  

 

A double beep will sound if a key is operating correctly, 
a long beep will sound if a key is faulty. Contact a safe 
engineer if a key is faulty. 

 

To add a user (Manager only) 

 

If  a  user  is  deleted,  the  user  can  be  activated  with  a 
new code. 

  Press and hold 1 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Enter a user ID number from 1-9. A double beep will 

sound  (If  a  double  beep  sounds  and  the  LED  turns 
off,  that  user  is  already  activated  and  can  be 
deleted) 

  The  user  should  enter  their  6  digit  code,  a  double 

beep will sound. 

  The  user  should  enter  their  6  digit  code  again  to 

confirm, a double beep will sound. 

 

The user should check the code to ensure correct entry 
whilst to door is open. 

 

User  9  can  only  be  activated  if  time  delay  is  not  in 
operation  or  during  the  open  window  if  time  delay  is  in 
operation. 

 


background image

To delete a user (Manager only) 

 

If a user’s code is no longer required it can be deleted 

  Press and hold 3 until a double beep sounds 

  Enter the manager code  

  Enter  the  user  ID  number  from  1-9.  A  double  beep 

will sound to confirm deletion of the user. 

 
To disable all users (Manager only) 

 

All  users  can  be  temporarily  be  disabled  without 
deleting their codes 
Press and hold 2 until a double beep sounds 
Enter the manager code  
A double beep will sound to confirm that all users have 
been disabled. 
 

To enable all users (Manager only) 

 

If  all  users  have  been  disabled,  their  codes  can  be  re-
enabled 

  Press and hold 2 until a double beep sounds 

  Enter the manager code  

A double beep will sound to confirm that all  users have 
been enabled. 
 

To check user status (Manager only) 

 

The  status  of  users,  whether  activated  or  deleted  can 
be checked 

  Press and hold 7 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Press each user ID in turn 

A double beep indicates the user is active 
A single beep indicates the user is deleted 

  Press 0 to leave the menu 

 

Checking  user  status  operates  if  all  users  are  disabled 
or enabled. 

 

To audit the lock (Manager only) 

 

Full  technical  instructions  for  taking  an  audit  are 
available  with  the  audit  software.  The  command 
required on the lock is: 

  Press and hold 7 until a double beep sounds 

  Enter the manager code 

  Firmly  hold  a  DS1996  Dallas  iButton  to  the  Dallas 

reader until a double beep sounds. 

 
To add time delay values (Manager only) 

 

  Press and hold 9 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Enter 2 digits to indicate the time delay period 01-99 

minutes.  Enter  2  digits  to  indicate  the  open  window 
period 01-19 minutes. A double beep will sound  

  Re-enter the 4 digits to confirm 

 

A  double  beep  will  sound  to  confirm  that  the  values 
have been set. 

To change time delay values (Manager only) 

 

To  increase  time  delay  values  follow  the  steps  in  “To 
enter time delay values”. 

 

To decrease or remove time delay values, the operation 
must  be  performed  during  the  open  window  before  the 
user  or  manager  code  is  entered.  To  decrease,  follow 
the steps in “To enter time delay values” 
To remove: 

  Press and hold 9 until a double beep sounds 

  Enter the manager code, a double beep will sound 

  Enter 00 to indicate the time delay period should be 

0  minutes.  Enter  01  to  indicate  the  open  window 
should not be operational. A double beep will sound. 

  Re-enter 0001 to confirm.  

 

A  double  beep  will  sound  to  confirm  that  values  have 
been set. The open window will continue. 

 

Optional Feature 

– Dual Mode 

 

If  the  lock  has  been  supplied  in  dual  mode,  user  1  is 
installed with the default code 1-1-1-1-1-1. 

 

To open the lock 

Two valid codes must be entered to open the lock, one 
of which can be a manager code. 

 

To open the lock when time delay is active 

One code is required to start time delay, and two codes 
are  required  to  open  the  lock  during  the  open  window. 
User 9 may override time delay with a single code. 

 

To perform a manager function 

A valid  user code must be entered before following the 
standard manager function procedure. 

 

Optional Feature 

– Alarm signals 

 

To enter a duress code 

If  the  feature  has  been  enabled,  a  duress  code  can  be 
entered  which  will open the lock and also send a silent 
signal to the alarm system to notify others that the lock 
is being opened under duress. 
The duress code is the user’s normal code, but the last 
digit should be increased by 1, for example: 

 

 

Normal code: 1-2-3-4-5-6 

 

Duress code: 1-2-3-4-5-7 

 

If the last digit is a 9, it should be changed to 0 

 

If time delay is active, either the first code to initiate time 
delay, or the code entered during the open window can 
be duress codes. 

 

If the lock is supplied in dual mode, either or both codes 
can be duress codes.  

 

Signals if remote block is active 

If the lock system is connected to an alarm and an input 
signal is received, the lock will  sound a long beep after 
entry  of  a  valid  code  to  indicate  that  it  is  disabled  from 
opening. 

 


background image

Optional Feature 

– Dallas keys 

 
If  Dallas  keys  are  in  use,  the  associated  Dallas  key 
must be touched to the reader after entry of a valid code 
for  opening  or  performing  any  function.  A  double  beep 
will sound to confirm acceptance. 
 
To associate a Dallas key to a user, follow the add user 
procedure  and  after  each  entry  of  the  new  code, touch 
the Dallas key to the reader until a double beep sounds. 
 
Once  a  user  is  associated  to  a  Dallas  key,  that  user 
must  always  use  a  Dallas  key.  If  a  key  has  been  lost, 
the user can be deleted and then added with a new key. 
 
To  associate  the  manager  to  a  Dallas  key,  follow  the 
change code procedure and after each entry of the new 
code, touch  the  Dallas  key  to the  reader  until  a  double 
beep  sounds.  If  a  manager  Dallas  key  is  lost,  the  lock 
must be reset. 
 
To  use  a  new  Dallas  key,  follow  the  change  code 
procedure using the old key with the old code, and use 
a new key with the new code. 
 

Troubleshooting  

 

Any key press results in a long beep 

The lock is in penalty caused by 4 consecutive incorrect 
code entries. The LED will flash every 10 seconds. Wait 
for  the  5-minutes  penalty  period  to  elapse  to  enter  a 
valid  code.  After  the  penalty  has  elapsed,  2  further 
wrong codes will again initiate a penalty. The trigger will 
reset  to  4  wrong  codes  after  a  correct  code  has  been 
entered. 

 

A long beep sounds 

The  code  or  function  has  not  been  entered  correctly, 
attempt to re-enter. If the problem persists, undertake a 
keypad test. 

 

If a mistake is made during code or function entry 

Wait 30 seconds and repeat the function 

 

3 short beeps during opening 

The  battery  is  running  low.  Consult  the  safe  or  vault 
supplier for information on changing batteries. 

 

Keys do not beep when pressed 

The  battery  may  be  depleted,  consult  the  safe  or  vault 
supplier 

for 

information 

on 

changing 

batteries. 

Alternatively,  keys  may  be  faulty,  undertake  a  keypad 
test. 

 

The safe or vault door does not open 

If the lock system is otherwise operating normally, there 
may be a mechanical fault with the safe. Contact a safe 
engineer. 

 

 