PDF User Manual

  1. Home
  2. Manuals
  3. TECHNOFASE RDM BK43-1A Technical Manual

TECHNOFASE RDM BK43-1A Technical Manual

RDM BK43-3A\ RDM BK43-3B\ RDM BK43-6B\ RDM BK43-9A

Made by: TECHNOFASE
Type: Technical Manual
Category: Radio Modems
Pages: 18
Size: 0.20 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

Technical Manual                                          Page 1 of 17 

www.technofase.com 

 
 
 
 

RDM BK43 

 
 

 

 
 
 

 

 
 
 
 
 
 
Valid for versions  

RDM BK43 - 1A  
RDM BK43 - 3A  

 

 

 

RDM BK43 - 3B  

 

 

 

RDM BK43 – 6B  

 

 

 

RDM BK43 – 9A  

 
 
 

 


background image

 

Technical Manual                                          Page 2 of 17 

www.technofase.com 

GENERAL INDEX 

Foreword

.................................................................................... 4

 

1. Safety instructions for the user and safety measures 
for the RDM BK43 system

....................................................... 5

 

Supplementary notes for RADIO interface appliances

...... 6

 

2. Introduction

.......................................................................... 7

 

2.1 Environmental characteristics

.......................................................................... 7

 

 

3. Compliance with the standard

........................................... 7

 

3.1 Reference Standard .............................................................................................. 8

 

3.2  CEPT 70-03 Recommendation

....................................................................... 9

 

3.3 Identification

...................................................................................................... 9

 

4. Technical data

..................................................................... 10

 

4.1 Models available

.............................................................................................. 10

 

4.2 Standard radio channels

................................................................................. 11

 

4.3 Communication interfaces

.............................................................................. 12

 

4.4 Power supply

................................................................................................... 12

 

4.5 Connections

...................................................................................................... 12

 

5. Assembly specifications

.................................................... 13

 

5.1  External assembly

.......................................................................................... 13

 

5.2  Assembly inside an electrical panel

............................................................. 13

 

6. Button functions

................................................................. 14

 

7. Labelling of the various models

....................................... 15

 

7.1 RDM BK43-3A Label

........................................................................................ 15

 

7.2 RDM BK43-3B Label

........................................................................................ 15

 

7.3 RDM BK43-6B Label

........................................................................................ 15

 

7.4 RDM BK43-9A Label

........................................................................................ 15

 

8. Product guarantee

............................................................. 16

 

 


background image

 

Technical Manual                                          Page 3 of 17 

www.technofase.com 

8.1

 

Terms of the guarantee

.............................................................................. 16

 

9.1

 

Standard concerning disposal

................................... 17

 

Manufacturer

.......................................................................................................... 17

 

 


background image

 

Technical Manual                                          Page 4 of 17 

www.technofase.com 

Foreword 

 

•  This  manual  contains  text,  images  and  explanations  for  the  correct 
installation  and  use  of  the  RDM  BK43  transceiver.  It  should  be  read  and 
understood before the appliance is installed and used.   
 
• This manual has been published subject to alteration. We reserve the right to 
modify this manual without prior notice. 
 
• As the system works by means of radio waves, transmission may, in certain 
cases,  be  influenced  by  the  environment  and  by  the  method  of  use.  The 
manufacturer is not liable for any damage to persons and/or appliances.   
 
• Do not use the system near other appliances operating with radio waves as 
this could cause malfunctioning.  

 

IMPORTANT  

 

• Do not remove or replace any parts of the system.  
 
•  Do  not  remove,  alter  or  modify  the  identification  plate  on  the  back  of  the 
system. It is forbidden to use the system without identification plates.   

 

Hardware Manual 
 
Revision: B.0 
 

Date: 06/2007 
 

 


background image

 

Technical Manual                                          Page 5 of 17 

www.technofase.com 

 

1. Safety instructions for the user and safety measures 
for the RDM BK43 system 

 

This manual has been drawn up for use by trained and competent personnel. 
The  qualification  of  the  personnel  is  defined  in  the  European  Directives  on 
machines,  low  voltage  and  EMV.  All  the  electrical  connections  of  RDM  BK43 
systems must be carried out by a technician who has specific training in local 
and  national  electrical  standards.  Several  symbols  are  used  in  this  manual  to 
highlight  certain  information.  The  purpose  of  these  symbols  is  to  draw  the 
attention  of  personnel  involved  to  warnings  concerning  safety  and  to  safety 
measures. Whenever a symbol appears, the relevant note should be read and 
the information followed carefully.  
 

 
This symbol indicates an imminent danger causing damage to persons 

or property.  
 

 
This symbol indicates a danger that could cause damage to persons or 

property.  

 
 
This symbol indicates the need to check the harmonization for the use 

of radio frequency.  
 
 
 
 
 
 
 

 


background image

 

Technical Manual                                          Page 6 of 17 

www.technofase.com 

 
• TECHNOFASE cannot be held responsible for damage due to inappropriate 
installation or operation of the appliances.  
 
• Do not replace the electrical components or attempt to repair products of the 
RDM BK43 series in any way.  
 
• The products of the RDM BK43 series must be used in accordance with the 
relevant local and national standards in force.  
 

 

 
 
 

 
 
 
 
 

 
 
 

Supplementary notes for RADIO interface appliances  

 
 
The products with radio interface have been designed to operate on UHF radio 
frequencies (433 – 436MHz) that vary from one country to another. The user 
must  take  care  to  check  the  standards  in  force  in  the  country  in  which  the 
appliance is being used before putting it into use.  
 

Contact the local Ofcom (Office of Communications) agency to obtain a licence 
or further information concerning the limitations on the free, unrestricted use 
(SRD) of the appliance.   

 
 

 


background image

 

Technical Manual                                          Page 7 of 17 

www.technofase.com 

 

2. Introduction 

 

 
The RDM BK43 system has been developed for transmitting and receiving data 
via radio.  
 
The special features of the RDM BK43 system are the following:  
 
•  Considerable immunity to disturbances 
 
•  Compact size 
 
•  IP65 die-cast aluminium casing  
 
•  Easily accessible RS232 communication port 
 
•  Up to 16 programmable channels that can be set using the buttons 
 
•  Power supply ranging from 10 to 15V   
 
•  Built-in flexible antenna ¼   
 
 

2.1 Environmental characteristics 

 
•  Operating temperature -20 / 50 °C 

 

•  Storage temperature -25 / 50 °C 

 

•  Relative humidity 5-85%, without condensation 

 

•  Vibration resistance  

 


background image

 

Technical Manual                                          Page 8 of 17 

www.technofase.com 

 

3. Compliance with the                Standard   

 

 

 
 
The system complies with the following harmonised standards:  
 
• EN 61000-6-1 Immunity to disturbances 
 
• EN 61000-6-3 Immunity to disturbances 
 
• EN 50082-2 Conducted emissions 
 
• EN 60950 Electrical safety 
 
• EN 301-489-1 + EN 301-489-3 Radio appliances 
 
• EN 300-220-1 + EN 300-220-3 ISM Band SRD 
 
• EN 300-296-2  
 

 

3.1 Reference Standard 

 

The RDM BK43 transceiver complies with the following European standards:   

EN 300 220

EN 301 489, EN 300 296

.  

Furthermore, the product has been tested according to standard 

EN 60950

.  

 

 


background image

 

Technical Manual                                          Page 9 of 17 

www.technofase.com 

 

3.2  CEPT 70-03 Recommendation 

 
The  RDM  BK43  product  operates  on  a  harmonised  frequency  band  and 
therefore, to comply with the standard in force, it must be used, on the time 
scale,  for  10%  max.  of  an  hourly  duty  cycle  (corresponding  to  6  minutes  of 
use per hour).   

NOTE: In view of the construction system, the user is responsible for 
compliance with this parameter. 

 

 
 

3.3 Identification 

 
The product is identified by the product identification number and a seven-
digit number (representing the series number and year of manufacture) on the 
casing.  

 
 

 


background image

 

Technical Manual                                          Page 10 of 17 

www.technofase.com 

 

4. Technical data 
 

Make 

TECHNOFASE 

Model 

BK43-XX 

Channels 

Selectable, up to 24 

Max. RF power 

500mW ERP 

Frequency stability 

+/- 1 KHz 

Power supply 

10-15V DC 

Operating temperature 

-20  / 50 °C 

Sizes excluding  
antenna 

150 x 64 x 36 mm 

 

4.1 Models available 

 
The models vary according to the frequency band and the antenna power 
 

RDM BK43 Mod. 3A 

433.175 - 434.675MHz    500mW ERP 

1

 

RDM BK43 Mod. 3C 

433.050 - 439.420MHz 

500mW ERP 

1

 

RDM BK43 Mod. 3B 

433.050 - 434.790MHz 

10mW ERP 

2

 

RDM BK43 Mod. 6B 

436.000 - 436.100MHz 

500mW ERP 

3

 

RDM BK43 Mod. 9A 

439.700 - 439.975MHz 

500mW ERP 

4

 

RDM BK43 Mod. 1A 

441.025 - 441.775MHz 

500mW ERP 

5

 

 

1) 

 This model can only be used in Austria and Switzerland after payment of the local licence fee. 

 

 

2) 

  This  model  can  only  be  used  in  countries  in  which this  power  limit  is  applied.  Check  with  the 

competent Office of Communications for possible use. 

 

 

3) 

This  model  can  only  be  used  in  Italy  according  to  the  frequency  assignment  plan,  point  101A, 

after filing a 

general authorisation application

 as set out in Presidential Decree no. 447 of 5 

October  2001,  Art.  5,  Para.  1,  Point  2,  and  after  payment  of  the  relevant  fee.  Contact  the  local  
department of the Office of Communications for further information concerning its use.  

 

4) 

 This model can only be used in Sweden in compliance with the country’s regulations.   

 

5) 

 This model can only be used in Norway in compliance with the country’s regulations.  

 


background image

 

Technical Manual                                          Page 11 of 17 

www.technofase.com 

 

4.2 Standard radio channels 

 

 

BK43-3A 

25KHz 

BK43-3C 

25KHz 

BK43-6B 

12.5KHz 

BK43-9A 

25KHz

 

BK43-1A 

12.5KHz

 

 

CH 1 

433.825 

433.825 

436.00625 

439.700 

441.0250 

 

CH 2 

433.875 

433.875 

436.01875 

439.725 

441.0750 

 

CH 3 

433.925 

433.925 

436.03125 

439.750 

441.1250 

 

CH 4 

433.975 

433.975 

436.04375 

439.775 

441.1750 

 

CH 5 

434.025 

434.025 

436.05625 

439.800 

441.2250 

 

CH 6 

434.075 

434.075 

436.06875 

439.825 

441.2750 

 

CH 7 

434.125 

434.125 

436.08125 

439.850 

441.3250 

 

CH 8 

434.175 

434.175 

436.09375 

439.875 

441.3750 

 

CH 9 

433.825

 123

 

433.825

 123

 

436.00625

 123

 

439.900 

441.4250 

 

CH 10 

433.875

 123

 

433.875

 123

 

436.01875

 123

 

439.925 

441.4750 

 

CH 11 

433.925

 123

 

433.925

 123

 

436.03125

 123

 

439.950 

441.5250 

 

CH 12 

433.975

 123

 

433.975

 123

 

436.04375

 123

 

439.975 

441.5750 

 

CH 13 

434.025

 123

 

434.025

 123

 

436.05625

 123

 

 

441.6250 

 

CH 14 

434.075

 123

 

434.075

 123

 

436.06875

 123

 

 

441.6750 

 

CH 15 

434.125

 123

 

434.125

 123

 

436.08125

 123

 

 

441.7250 

 

CH 16 

434.175

 123

 

434.175

 123

 

436.09375

 123

 

 

441.7750 

 

CH 17 

433.900 

433.900 

436.00625 

 

 

 

CH 18 

433.950 

433.950 

436.01875 

 

 

 

CH 19 

434.100 

434.100 

436.03125 

 

 

 

CH 20 

434.150 

434.150 

436.04375 

 

 

 

CH 21 

434.200 

434.200 

436.05625 

 

 

 

CH 22 

434.400 

439.390 

436.06875 

 

 

 

CH 23 

 

439.410 

436.08125 

 

 

 

CH 24 

 

439.430 

436.09375 

 

 

 

 
 
 

 


background image

 

Technical Manual                                          Page 12 of 17 

www.technofase.com 

4.3 Communication interfaces  

 
 

RS232   

RS232 standard interface 

 

 

 

Mini DIN 6 F type connection 

 

4.4 Power supply  

 

The RDM BK43 transceiver must be run on a very low safety voltage 
supply protected against short circuits.  
 
Supply voltage:  

 

 

10-15V  

Maximum absorption in Tx: 

 

400 mA 

Protection against short circuits: 

Polyswitch  

Type: 

 

 

Resettable RXE040 

 

 
 

4.5 Connections 

 

For external connections, a screened cable with a MINIDIN 6 type 
connector has been provided both for data and for the power supply. 
All electrical connections are designed for lengths up to a max. of 3m.   

 

 

 


background image

 

Technical Manual                                          Page 13 of 17 

www.technofase.com 

 

5. Assembly specifications 
 

5.1  External assembly 

 

External assembly can be carried out using a support plate with a 24 
mm hole in the centre. This plate must then be fixed to a suitable 
means of support.  

 

 

5.2  Assembly inside an electrical panel 

 

For assembly inside an electrical panel, a hole 24 mm in diameter must 
be drilled to allow the antenna to transmit and receive outside. The 
earthing surface must be at least 20cm x 20cm in size.  

 
 

 


background image

 

Technical Manual                                          Page 14 of 17 

www.technofase.com 

 

6. Button functions 
 

 
 

Three rubber buttons are located in the lower part to set the channel and to 
switch the appliance on/off.  
The  display  shows  the  number  of  the  channel  currently  set.  To  change 
channels,  press  the  CHANNEL  button  until  the  number  shown  on  the  display 
starts  flashing  (ACTUAL  CHANNEL):  then  press  the  INCREMENT  button  to 
increase  the  channel  number.  To  lower  the  number  continue  pressing  the 
button until the last channel (24) is reached and the system starts again from 
1. After setting the channel, press the CHANNEL button again until the flashing 
stops. The TX/RX LED indicates reception when green and transmission when 
red.  

 


background image

 

Technical Manual                                          Page 15 of 17 

www.technofase.com 

 

7. Labelling of the various models 
 
7.1 RDM BK43-3A label  

 
 
 
 
 
 
 

7.2 RDM BK43-3B label 

 

 

 
 
 
 

7.3 RDM BK43-6B label 

 
 

 
 
 
 

 

7.4 RDM BK43-9A label 

 
 

 
 
 

 
 

 


background image

 

Technical Manual                                          Page 16 of 17 

www.technofase.com 

 

8. Product guarantee 
 
8.1

 

Terms of the guarantee 

 

8.2.1 GUARANTEE AND CONDITIONS

  

 
Technofase  products  are  covered  by  a  2  (TWO)  YEAR  guarantee  from  the  date  of 
purchase  with  the  exception  of  the  batteries  which  are  covered  by  a  6  (SIX)  MONTH 
guarantee. During this period Technofase undertakes, at its sole discretion, to repair or 
replace  faulty  components  with  similar  or  equivalent  products  or  to  refund  the 
Customer  for  the  amount  paid  for  the  component  in  the  case  of  faulty  material  or 
manufacturing  defects.  If  the  label  with  the  series  number  of  a  product  has  been 
cancelled,  tampered  with,  or  partially  or  completely  covered,  Technofase  reserves  the 
right  not  to  consider  such  a  product  under  guarantee.  The  guarantee  covers 
manufacturing  faults  in  the  components  at  the  time  of  purchase  and  the  labour 
necessary to repair them.     
The guarantee is null and void in the event of: improper use of the product, negligence, 
intentional  damage  or  any  problem  due  to  incorrect  installation  after  purchase.  The 
guarantee is of the “on-centre” type, i.e. the customer is only liable for paying the cost 
of dispatching the faulty product to the repair shop.  
 
8.2.2 

 DURATION OF THE GUARANTEE FOLLOWING SERVICES UNDER THE 

GUARANTEE

  

 
Any service carried out under the guarantee will not prolong the duration of the 
guarantee.  
 
 
8.2.3 

 RESPONSIBILITY TOWARDS THIRD PARTIES

  

 
The  buyer  will  not  hold  Technofase  responsible  with  regard  to  any  controversy  that 
may  arise  with  the  final  user  as  the  buyer  undertakes  to  check  in  advance  the 
appropriateness  of  the  system  configuration  and  of  every  single  component  he  has 
purchased. It is  expressly understood that Technofase is responsible only towards the 
first buyer and exclusively within the terms provided for by the guarantee clause.   
 
 

 


background image

 

Technical Manual                                          Page 17 of 17 

www.technofase.com 

 
9.1 

Standard concerning disposal  

 
 
 

EC-Directive  2002/96  Waste  electrical  and  electronic  appliances  – 
RAEE. 
This product complies with EU Directive 2002/96/EC.  
The  symbol  of  the  crossed  litter  bin  appearing  on  the  appliance 
indicates  that  at  the  end  of  its  useful  life  the  product  must  be 
disposed of separately from household waste. The user is responsible 
for taking the appliance to a suitable collection point at the end of its 

life.  Separate  waste  collection  and  subsequent  recycling,  processing  and  the  eco-
friendly  disposal  of  exhausted  appliances  contribute  towards  preventing  negative 
effects on the environment and on health and help to recycle the materials of which the 
product  is  made.  Contact  the  local  waste  disposal  service  or  the  shop  in  which  the 
product was purchased for more detailed information concerning the collection systems 
available.   

 
 
 
 

 
 
Manufacturer 

 

RDM BK43 is made by: 

 

TECHNOFASE 
Via GALVANI 23 
39100 BOLZANO 
Tel 0471500450 
Fax 0471513944 

info@technofase.com

 

 
 
 
 
 

THE TERMS AND CONDITIONS IN THIS DOCUMENT MAY BE CHANGED WITHOUT PRIOR NOTICE.