REVISED 16. JUNE. 2017 

 

 

SKIPIO 

Commercial Refrigerators & Freezers 

User Manual 

REACH-IN (UPRIGHT) 

SRT, SFT & SRFT series 

Chiller, Freezer & Dual Temperature 

 

      

       

 

 

       

      

 

 


background image

 
 

Turbo Air Warranty 

 

WARRANTY CLAIMS

 

– The user must report to its dealership, hence the dealer 

can accumulate all  pertinent  information  supporting the existence of the alleged 
defect.  

 

 

TWO YEARS PARTS & LABOUR WARRANTY 

Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet 
and all parts thereof, to be free from defects in material or workmanship, under normal use and 
service, for a period of two (2) year from the date of original installation. 

 

Any parts covered by this warranty that are examined and determined by Turbo Air to have been 
defective within two (2) year of original installation shall be repaired or replaced as stated below. 
Turbo Air shall be deemed to have full complied with its obligation under the foregoing warranties 
by electing either one of the following procedures, at the sole discretion of Turbo Air: 

(a)  Furnishing  a  replacement  part,  freight  collect,  in  even  exchange  for  the  returned  part, 

freight collect; 
 

(b)  Receiving the defective part, freight collect; repairing it, freight collect. 

 

What is NOT covered by this warranty? 

Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, 
subject  to  the  additional  limitations  below.  This  warranty  neither  assumes  nor  authorizes  any 
person to assume obligations other than expressly covered by this warranty. 

 

1.  Warranty is NOT TRANSFERABLE. This warranty is not assignable and applies only in 

favour of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR 
TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL 
WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING  ANY  WARRANTY  OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
 
 

 


background image

REVISED 16. JUNE. 2017 

 

 

2.  NO  CONSEQUENTIAL  DAMAGES,  TURBO  AIR  IS  NOT  RESPONSIBLE  FOR 

ECONOMIC  LOSS;  PROFIT  LOSS  OR  SPECIAL,  INDIRECT,  OR  CONSEQUENTIAL 
DAMAGES,  INCLUDING  WITHOUT  LIMITATION,  LOSSES  OR  DAMAGES  ARISING 
FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT 
OF REFRIGERATION FAILURE. 
 

3.  ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT 

OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD, TURBO AIR is not responsible for 
the repair or replacement of any parts that Turbo Air determines have been subjected after 
the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during 
transit or installation, fire, flood, or an Act of God.  
 

4.  TRANSPORTANTION COSTS 

– Turbo Air will accept parts covered under this warranty 

freight  collect,  provided  that  shipment  has  received  prior  approval.  Turbo  Air  is  not 
responsible  for  any  other  transportation  costs,  but  will  ship  freight  collect  parts  either 
repaired or replaced under this warranty. 
 

5.  Any  services  from  an  unauthorized  person  including  owner 

–  Turbo  Air  will  not  accept 

misuse of display controller which is not mentioned on user manual.  
 

6.  Warranty does not cover any services from any unauthorized technician including owner. 

 

7.  Consumable  parts  such  as  door  gaskets,  castors,  legs,  etc.  are  excluded  from  the 

warranty.  
 
 
 

 
 
 

 

 

 

 

 

 

 

 

 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

Contents 

 

1.  MODELS ........................................................................ 5 
2.  INSTALLATION ............................................................. 6 

Warning & Safety Instructions

 ................................................................................................. 6 

Installing the Unit

 ........................................................................................................................... 7 

1. Avoid heat source

 ....................................................................................................................... 7 

2. Levelling

 ......................................................................................................................................... 7 

3. Ventilation

 ...................................................................................................................................... 8 

Shelving

 ................................................................................................................................................ 8 

Loading Product

 ............................................................................................................................... 9 

3.  OPERATION

 ......................................................................................................................... 10 

Start Up

 .............................................................................................................................................. 10 

Electronic Controller

 ................................................................................................................... 10 

Power On/Off

 .................................................................................................................................... 11 

Lock/Unlock the display controller

 ...................................................................................... 11 

Controller Alarms for users

 ...................................................................................................... 12 

4.  SERVICING

 ........................................................................................................................... 13 

Cleaning Cabinet

 ........................................................................................................................... 13 

Cleaning Condenser

 ..................................................................................................................... 13 

Troubleshooting

 ............................................................................................................................. 14 

 

 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

1.MODELS 

 

UPRIGHT SOLID DOOR 

Model 

Type 

Config. 

Doors 

Operating temperature range 

SRT25-1 

Refrigerator

 

Solid Door 

+1°C to +8°C up to 38°C ambient 

SRT25-2 

Refrigerator

 

Solid Door

 

2

 

SRT45-2 

Refrigerator

 

Solid Door

 

2

 

SRT45-4 

Refrigerator

 

Solid Door

 

4

 

SRT65-3 

Refrigerator

 

Solid Door

 

3

 

SRT65-6 

Refrigerator

 

Solid Door

 

6

 

SFT25-1 

Freezer

 

Solid Door

 

-21°C to -12°C up to 38°C ambient 

SFT25-2 

Freezer

 

Solid Door

 

SFT45-2 

Freezer

 

Solid Door

 

SFT45-4 

Freezer

 

Solid Door

 

SFT65-3 

Freezer

 

Solid Door

 

SFT65-6

 

Freezer

 

Solid Door

 

 

UPRIGHT SOLID DOOR – Dual Temperature  

Model 

Type 

Config. 

Doors 

Operating temperature range 

SRFT25-2 

Dual Temp 

Solid Door

 

R-Compartment 

+1°C to +8°C up to 38°C ambient 

 

F-Compartment 

-21°C to -12°C up to 38°C ambient 

SRFT45-2 

Dual Temp

 

Solid Door

 

SRFT45-4 

Dual Temp

 

Solid Door

 

SRFT65-3 

Dual Temp

 

Solid Door

 

SRFT65-6 

Dual Temp

 

Solid Door

 

 

 

UPRIGHT GLASS DOOR 

Model 

Type 

Config. 

Doors 

Operating temperature range 

SRT25-1G 

Refrigerator 

Glass Door 

+1°C to +8°C up to 38°C ambient 

SRT45-2G 

Refrigerator

 

Glass Door 

SRT65-3G 

Refrigerator

 

Glass Door 

SRT25-2G 

Refrigerator

 

Glass Door 

SRT45-4G 

Refrigerator 

Glass Door 

SRT65-6G 

Refrigerator 

Glass Door 

SFT25-1G 

Freezer 

Glass Door 

-21°C to -12°C up to 38°C ambient 

SFT25-2G 

Freezer 

Glass Door 

SFT45-2G 

Freezer 

Glass Door 

SFT45-4G 

Freezer 

Glass Door 

4  

SFT65-3G 

Freezer 

Glass Door 

 


background image

REVISED 16. JUNE. 2017 

 

 

2.

 

INSTALLATION 

 

Warning & Safety Instructions 

This appliance conforms to current safety requirements. However, inappropriate use can cause 
injury and damage to property. 

 

  Do not cover the grilles or block the entry of airflow (condenser) or exhaust of airflow by 

placing objects up against the refrigeration unit; 
 

  Ensure adequate ventilation provided for the appliance as this is essential to 

performance, at least 50 mm from the wall;

 

 

  Ensure the safe power supply and current draw for the appliance as overload of the 

power supply can damage the entire unit; 
 

  Ensure to install the appliance indoor; 

 

  Avoid damp and dusty environment which may cause electric shock; 

 

  Use casters or legs for the unit; 

 

  Must disconnect the unit from the power supply prior to cleaning or maintenance; 

 

  Ensure not to put hot food in the unit; 

 

  Preferred to use the leakage protector to prevent the short circuit; 

 

  Ensure not to store volatiles and combustibles inside cabinet. 

 

 
 

 

 

 

 

 

 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

 
Installing the Unit 

 

1. Avoid heat source 

Avoid  direct  sunlight,  uneven  surface,  hot  environment  beyond  recommended  ambient 
temperature of the cabinet. 

 

The unit must NOT be situated where it is affected by hot air from adjacent equipment as this will 
compromise the airflow and performance of the cabinet. 

 

2. Levelling 

If  the  cabinet  is  installed  on  an  even  surface  or  not  levelled,  water  from  condensate  tray  may 
overflow.   

 

Once, water leakage occurs by inappropriate levelling, the unit has to be re-levelled. Turbo Air is 
not obligated to provide warranty service in case of operator error. 

A spanner and four spacers are included in a package. A scissor jack (car jack) is required to lift 
up the cabinet for easy placement of the spacers. 

 

 

Loosen the screw to provide enough gap for spacers and fasten it. 

 


background image

REVISED 16. JUNE. 2017 

 

 

 

3. Ventilation 

Providing an environment with good ventilation prolongs the life of compressor and performance. 
Air flows into condenser (front) and the outflow of the used air is exhausted via outlets. For efficient 
operation of the cabinet, providing adequate ventilation and ambient temperature (below 38°) is 
essential.  

 

 

Prior to installation of the unit, a gap of at least 50 mm must be left from the walls as outlets of 
the used air are located at the back of the unit. 

 

Shelving 

Inside the cabinet, there is a shelf package. Remove all packaging material. Each shelf is paired 
with 4 support brackets (shelf clips).  

 

 

 

The shelves can be positioned at different heights for customer’s preference. Always ensure that 
the support brackets are securely engaged in each of the shelf support rail.  

It is recommended that the cabinet operates for 30 minutes prior to loading product. 

 


background image

REVISED 16. JUNE. 2017 

 

 

 

Loading Product 

 

 

Do not overload products: a maximum loading of 20kg per shelf

 

 

 

Do not allow products to overhang the front of the shelf which may prevent the door from 
shutting

 

 

 

Place products with air space for even cooling and efficient operation

 

 
 
 

 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

3.OPERATION 

 

Start Up 

Plug into the main power supply and check operation of the unit, front display and lighting. The 
compressor and the condenser and evaporator fans should all operate within 2 minutes from the 
moment the unit is plugged in. The cabinet light (inside) will go on when a door is opened.  

 

Electronic Controller 

Turbo Air electronic controller controls and displays the internal cabinet temperature. For general 
operation, no initial setup or additional programing is required. When the cabinet is connected to 
the power supply, the current cabinet temperature will be displayed on the electronic controller. 
Generally, the compressor and evaporator fan will operate within 2 minutes after power supply to 
the cabinet. 

 

1. Electronic controller for freezers (SRT/SFT-series) 

 

Factory setup temperature of SFT-series is - 18°C. By pressing either up or down button, setting 
temperature can be adjust

ed according to customer’s preference. 

Factory setup temperature of  SRT-series is 2°C. By pressing either up or down button, setting 
temperature can be adjusted 

according to customer’s preference. 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

 

Power On/Off 

Plugging  into  the  power  automatically  turns  on  the  cabinet.  There  are  several  ways  manually 
power on and off while pugging in.   

 

1. There is a power switch located at the top of the cabinet (near condenser).

 

 

2. Alternatively, the cabinet can be turned on and off by pressing down button on the front 
display for 10 seconds.   

 

 

Lock/Unlock the display controller 

To prevent anyone adjusting setting, press up button for 10 seconds, which will lock the display 
controller.  

 

Pressing up button for 10 seconds will unlock the display controller. 

 


background image

REVISED 16. JUNE. 2017 

 

 

 

 

Controller Alarms for users  

Electric controller When the inside temperature is lower than - 45°C, the panel will display 

‘LO’

and higher than +18°C, 

‘HI’

 will be displayed.  

Defrost starts when the icing on the evaporator occurs: usually 4 ~ 6 times a day.  

 

 

 

It will take 20 ~ 30 minutes to finish defrost. The compressor drops the cabinet temperature down 
to further 

– 7°C on the current setting temperature.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 


background image

REVISED 16. JUNE. 2017 

 

 

4.SERVICING 

 

Cleaning Cabinet 

Using a damp cloth for cleaning both the interior and exterior of the cabinet is recommended when 
it requires. Before cleaning, the cabinet should be disconnected from the power supply.  

 

Cleaning Condenser 

Cleaning  condenser  coils  is  the  most  important  th

ing  a  customer’s  can  do  to  maintain  a 

freezer/refrigerator’s longevity. The condenser coil is located behind the top grile. The condenser 
coil must be maintained clean for reliable and efficient operation. Condenser blockage may cause 
shortening the life of the compressor and, increasing power consumption. 

 

To ensure trouble free performance, the condenser coil should be brushed once a month.  

Easy access to the condenser from the top will allow simple and quick cleaning environment.  

 

As shown the picture above, condenser is located at the top of the unit. A ladder is required to 
access to the top of the unit. On the top of the unit there is a cover which can be removed by a 

 


background image

REVISED 16. JUNE. 2017 

 

 

screw driver or a hand drill. Once, open up the top cover, brush the condenser and reassemble 
the cover. 

Over time, dust may accumulate within the condenser that cannot be removed with a brush. If 
this occurs, contact Turbo Air to arrange for  a Turbo Air authorized service agent to clean the 
condenser with compressed air. 

 

Troubleshooting 

Issue 

Possible cause 

Resolution 

Warm cabinet temperature 

Condenser blockage 
 
Poor ventilation environment  
 

Clean condenser 
 
Provide good ventilation around the side 
and back of the unit 

Power consumption is higher 
than supposed to be 

Dirty Condenser 
 
Unit operating in too high temperature 
 
 
Cabinet doors are opened excessively 
 

Clean condenser 
 
Provide good ventilation around the side 
and back of the unit 
 
Keep door/s open for minimum time 
 

Water leakage inside cabinet 

Unit is not levelled properly 
 

Level the unit 

(Ref: 2 Installation 

– Levelling)

 

No power to unit 

Unplugged 
 
Accidently turned off via display 

(Ref: 3 Operation 

– Power On/Off) 

 
Power switch off in the condensing unit 

(Ref: 3 Operation 

– Power On/Off) 

Plug in 
 
Press down button for 10 seconds  

(Ref: 3 Operation 

– Power On/Off) 

 
Power switch on in the condensing unit 

(Ref: 3 Operation 

– Power On/Off) 

Display controller does not 
work  

Locked 

(Ref: 3 Operation 

– Lock/Unlock 

the Display Controller)

 

 
Press up button for 10 seconds  

(Ref: 3 Operation 

– Lock/Unlock the Display 

Controller)