background image

State: 2010-03-01 

 

Vers. no.: 1.10                          

 

m. dudde hochfrequenz-technik     Rottland 5a    D-51429   Bergisch Gladbach/ Germany    Tel. +49 2207-96890    Fax  +49 2207 968920 

 
 
 
 
 
 

Annex no. 5 

 

Functional Description / 

User Manual 

 


background image

 

 

 

SAFE-O-TRONIC

®

 

access 

Electronic Identification and Locking System 

DS 200, DS 300, DS 400 

MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Schulte-Schlagbaum AG 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC DS 

Page 2 of 5 

SOT_DS_5020x_Manual.doc 

 

Note 

 Copyright 2011 by 

Schulte-Schlagbaum AG 
Nevigeser Straße 100-110 

 

Postfach 101240 

D-42512 Velbert 
Tel.: +49 2051 2086 / 0 
FAX: +49 2051 2086 / 918 

 

www.sag-schlagbaum.com

 

 

Edition: 04/2011 V1.0 -  Document number:    

SOT_DS_5020x_Manual.Doc

 

 

 

This edition replaces all earlier editions. 
The information in this document may be changed without notice. 

 

Relaying  and  duplication  of  this  document  and  the  exploitation  and  communication of  its  contents 
are  not  permitted  unless  expressly  allowed.  Violations  shall  obligate  to  provide  compensation  for 
damages. All rights reserved in the event of patent grant or registration of a utility model or design. 

 

The  information  in  this  manual  has  been  put  together  to  the  best  of  our  knowledge.  
Schulte-Schlagbaum AG does not issue a guarantee for the correctness and completeness of the details in 
this manual. In particular, Schulte-Schlagbaum AG cannot be made liable for consequential damages due to 
incorrect or incomplete details. As errors can never be completely avoided in spite of all efforts, we would be 
grateful for your feedback at any time. 

 

The  installation  recommendations  in  this  document  pre-suppose  the  most  favourable  general  conditions. 
Schulte-Schlagbaum AG shall not issue a guarantee for the proper function in environments alien to the sys-
tem. 

 

Schulte-Schlagbaum AG shall not issue a guarantee that the information contained in this document is free 
from  third-party  industrial  property  rights. With  this  document  Schulte-Schlagbaum  AG  does  not  issue  any 
licences for its own or third-party patents or other industrial property rights. 

 

Subject to alterations. 

 

 

SAFE-O-TRONIC    is a registered trademark of Schulte-Schlagbaum AG 

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC DS 

Page 3 of 5 

SOT_DS_5020x_Manual.doc 

 

1. Description 

Electronic PIN-Code / RFID door locking system, with MIFARE-technology and other RFID-
technologies according ISO 14443 A,  with wide possibilities to individualize e. g. room, labelling or 
logo by exchangeable cover plates. Adaptable for right and left handed doors. The lock will be re-
leased after entering a 4-6 digit code or using the RFID data medium.  

 

 

Touchless read and write of the RFID data medium 

 

Time zone  to set up limited locking authorizations 

 

Automatically change of authorisation by using a new RFID data medium in case of theft of the 
previous RFID data medium 

 

Automatically daily organisation of limited authorisations in combination with online terminals 
(CyberSpots) 

 

Locking authorisations can be changed at any time 

 

Quick programming of the lock with help of RFID data medium or communicator 

 

Individual release and blocking of RFID data medium with 254 locking sequences each 

 

RFID data medium with MasterKey-Function to open and close  

 

Emergency Opening with help of RFID data medium in case the user has lost his RFID data 
medium 

 

RFID data medium with MasterKey-Function, with limited locking authorizations for the whole  
locking system and for defined areas within a locking system  

 

Audit trail for 500 operations 

 

Automatic wake-up of the electronic by approaching with RFID data medium 

 

Easy integration in existing systems (e.g. RFID door locking systems, guest management sys-
tems, parking, wellness etc.) or other data systems (time and attendant systems, member soft-
ware, access control, hotel front office systems or cashless payment) 

 

Battery at the outside of the locker door 

 

Battery life time: approx. 3 years (by 30 cycles per day) 

 

Intelligent battery management system: permanent battery control ensures to open the locker 
door at any time   

 

robust metal housing  

 

Certified security against break-up 

 

Suitable for all kind of door materials 

 

No cabling required  

 

Suitable for wet areas, protected against spray water (IP 43) 

 

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC DS 

Page 4 of 5 

SOT_DS_5020x_Manual.doc 

 

2. Technical data 

 

 

Protection class according to 
DIN EN 60529 

IP 43

 

 

Weight

 

approx. 750 g 

 

Temperature range 

     in use 
     in storage

 

 
   0 °C 
-15 °C

 

 
to 
to

 

 
60 °C 
60 °C

 

 

Relative air humidity 

 

10 % 

 

(to) 

 

 
90 % (without condensation)

 

 

Battery 

Battery pack: 3 x alkaline cells (AAA) 

 

Battery life

 

Approx. 3 years at 30 lockings per  

 

 

Transponder type used

 

Mifare, ISO 14443 A 

 

 

Buzzer 

integrated 

 

Signal alerts 

 

2 red LED 
2 green LED 

 

Colour of housing frame 

stainless steel 

 

Colour of the control panel 

Black 

 

Dimensions (W x H x D)

 

204 x 55 x 21 mm

 

 

3. Approval 

 

Radio 
- Europa 
- USA 

 
EN 300 330 
FCC 47 CFR Part 15 

EMC 

EN 300 489 

Safety 
- Low-Voltage 
- Human Exposure 

 
EN 60950 
EN 50364 

Waste and Hazardous  
Substances 

RoHS - 2002/95/EC 
WEEE - 2002/96/EC 

 

4. Declaration of Conformity for USA 

 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and  
(2) this device must accept any interference received, including interference that may cause undesired op-
eration. Usually this is followed by the following FCC caution: 
Any changes or modifications not expressly approved by the party responsible for compliance could void the 
user's authority to operate this equipment.

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC DS 

Page 5 of 5 

SOT_DS_5020x_Manual.doc 

 

5. Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Housing dimensions

 

Fixing dimensions

 

 


background image

 

SAFE-O-TRONIC

®

 

access 

Electronic Identification and Locking System 

LS100, LS 200, LS 300, LS 400

 

MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Schulte-Schlagbaum AG 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC LS 

Page 2 of 6 

SOT_LS_30084x_Manual.doc 

 

Note 

 Copyright 2011 by 

Schulte-Schlagbaum AG 
Nevigeser Straße 100-110 

 

Postfach 101240 

D-42512 Velbert 
Tel.: +49 2051 2086 / 0 
FAX: +49 2051 2086 / 918 

 

www.sag-schlagbaum.com

 

 

Edition: 04/2011 V1.0 -  Document number:    

SOT_LS_30084x_Manual.Doc

 

 

 

This edition replaces all earlier editions. 
The information in this document may be changed without notice. 

 

Relaying  and  duplication  of  this  document  and  the  exploitation  and  communication of  its  contents 
are  not  permitted  unless  expressly  allowed.  Violations  shall  obligate  to  provide  compensation  for 
damages. All rights reserved in the event of patent grant or registration of a utility model or design. 

 

The  information  in  this  manual  has  been  put  together  to  the  best  of  our  knowledge.  
Schulte-Schlagbaum AG does not issue a guarantee for the correctness and completeness of the details in 
this manual. In particular, Schulte-Schlagbaum AG cannot be made liable for consequential damages due to 
incorrect or incomplete details. As errors can never be completely avoided in spite of all efforts, we would be 
grateful for your feedback at any time. 

 

The  installation  recommendations  in  this  document  pre-suppose  the  most  favourable  general  conditions. 
Schulte-Schlagbaum AG shall not issue a guarantee for the proper function in environments alien to the sys-
tem. 

 

Schulte-Schlagbaum AG shall not issue a guarantee that the information contained in this document is free 
from  third-party  industrial  property  rights. With  this  document  Schulte-Schlagbaum  AG  does  not  issue  any 
licences for its own or third-party patents or other industrial property rights. 

 

Subject to alterations. 

 

 

SAFE-O-TRONIC    is a registered trademark of Schulte-Schlagbaum AG 

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC LS 

Page 3 of 6 

SOT_LS_30084x_Manual.doc 

 

1. Description 

Electronic PIN-Code / RFID locking system for lockers, safe-deposit boxes and functional furniture, 
with MIFARE-technology and other RFID-technologies according ISO 14443 A,  round rotary knob 
to operate the locking cam and wide possibilities to individualize e. g. locker numbers, writing or 
logo by exchangeable plates. Suitable for locker doors, which are originally prepared for cylinder 

lever locks. Adaptable for right and left handed locker doors in four different mounting directions. 
The lock will be released after entering a 4-6 digit code or using the RFID data medium.  

 

 

Operation mode: „free locker mode“ and „fixed locker mode“ 

 

Touchless read and write of the RFID data medium 

 

Time zone  to set up limited locking authorizations 

 

Automatically change of authorisation by using a new RFID data medium in case of theft of the 
previous RFID data medium 

 

Automatically daily organisation of limited authorisations in combination with online terminals 
(CyberSpots) 

 

Set up for automatically blocking in case of exceeding the programmed time  

 

Set up for automatically opening in case of exceeding the programmed time 

 

Locking authorisations can be changed at any time 

 

Quick programming of the lock with help of RFID data medium or communicator 

 

Individual release and blocking of RFID data medium with 254 locking sequences each 

 

RFID data medium with MasterKey-Function to open and close  

 

Emergency Opening (only opening) with help of RFID data medium in case the user has lost his 
RFID data medium 

 

RFID data medium with MasterKey-Function, with limited locking authorizations for the whole  
locking system and for defined areas within a locking system  

 

Audit trail for 500 operations 

 

Automatic wake-up of the electronic by approaching with RFID data medium 

 

Manual possibility to unlock ensures functional safety also in case of jammed locker doors  

 

Convenient user guidance  by Free- / -- Occupied display as well as optical and acoustic signal 

 

Easy integration in existing systems (e.g. RFID door locking systems, guest management sys-
tems, parking, wellness etc.) or other data systems (time and attendant systems, member soft-
ware, access control, hotel front office systems or cashless payment) 

 

Battery at the outside of the locker door 

 

Battery life time: approx. 3 years (by 30 cycles per day) 

 

Intelligent battery management system: permanent battery control ensures to open the locker 
door at any time   

 

robust metal housing  

 

Certified security against break-up 

 

Suitable for all kind of door materials 

 

No cabling required  

 

Suitable for wet areas, protected against spray water (IP 43) 

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC LS 

Page 4 of 6 

SOT_LS_30084x_Manual.doc 

 

2. Technical data 

 

 

Protection class according to 
DIN EN 60529 

IP 43

 

 

Weight

 

approx. 300 g 

 

Temperature range 

     in use 
     in storage

 

 

   0 °C 
-15 °C

 

 

to 
to

 

 

60 °C 
60 °C

 

 

Relative air humidity 

10 % 

(to) 

 

90 % (without condensation)

 

 

Battery 

Battery pack: 3 x alkaline cells (AAA) 

 

Battery life

 

Approx. 3 years at 30 lockings per 

 

 

Transponder type used

 

Mifare, ISO 14443 A

 

 

Buzzer 

integrated 

 

Signal alerts 

2 red LED 2 green LED 

 

Colour of housing frame 

Similar to RAL 9006 (white aluminium) 

 

Colour of the control panel 

Black 

 

Dimensions (W x H x D)

 

151 x 38 x 33 mm

 

 

3. Approval 

 

Radio 
- Europa 
- USA 

 
EN 300 330 
FCC 47 CFR Part 15 

EMC 

EN 300 489 

Safety 
- Low-Voltage 
- Human Exposure 

 
EN 60950 
EN 50364 

Waste and Hazardous  
Substances 

RoHS - 2002/95/EC 
WEEE - 2002/96/EC 

 

4. Declaration of Conformity for USA 

 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference re-
ceived, including interference that may cause undesired operation. 
Usually this is followed by the following FCC caution: 
Any changes or modifications not expressly approved by the party responsible for compliance could void the 
user's authority to operate this equipment.

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC LS 

Page 5 of 6 

SOT_LS_30084x_Manual.doc 

 

5. Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preparation of the door  

 

 

 

 

 

 

 

 

 

 

 


background image

SAFE-O-TRONIC

 access

 

Manual 

 

 

SAFE-O-TRONIC LS 

Page 6 of 6 

SOT_LS_30084x_Manual.doc 

 

 

6. System Delivery Contents 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

  

Lock 

 

2

  

Nut

 for mounting the lock on the door  

3

  

Grommet

 for setting the rotational direction of the rotary knob in order to lock 

4

  

Locking lever 

(a cropped or hook-shaped locking lever can also be used depending on the  

properties and condition of the cabinet) 

5

  

Fastening screw

 for locking lever 

6

  

Bush fo

r fastening the lock to the door for door thicknesses of 

10mm to 18mm

 

7

  

Bush fo

r fastening the lock to the door for door thicknesses of 

1mm to 9mm 

8

  

Screw

 for fastening the lock to the door  

9  Rotary knob