Full Text Searchable PDF User Manual
State: 2010-03-01
Vers. no.: 1.10
m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
Annex no. 5
Functional Description /
User Manual
SAFE-O-TRONIC
®
access
Electronic Identification and Locking System
DS 200, DS 300, DS 400
MANUAL
Schulte-Schlagbaum AG
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC DS
Page 2 of 5
SOT_DS_5020x_Manual.doc
Note
Copyright 2011 by
Schulte-Schlagbaum AG
Nevigeser Straße 100-110
Postfach 101240
D-42512 Velbert
Tel.: +49 2051 2086 / 0
FAX: +49 2051 2086 / 918
www.sag-schlagbaum.com
Edition: 04/2011 V1.0 - Document number:
SOT_DS_5020x_Manual.Doc
This edition replaces all earlier editions.
The information in this document may be changed without notice.
Relaying and duplication of this document and the exploitation and communication of its contents
are not permitted unless expressly allowed. Violations shall obligate to provide compensation for
damages. All rights reserved in the event of patent grant or registration of a utility model or design.
The information in this manual has been put together to the best of our knowledge.
Schulte-Schlagbaum AG does not issue a guarantee for the correctness and completeness of the details in
this manual. In particular, Schulte-Schlagbaum AG cannot be made liable for consequential damages due to
incorrect or incomplete details. As errors can never be completely avoided in spite of all efforts, we would be
grateful for your feedback at any time.
The installation recommendations in this document pre-suppose the most favourable general conditions.
Schulte-Schlagbaum AG shall not issue a guarantee for the proper function in environments alien to the sys-
tem.
Schulte-Schlagbaum AG shall not issue a guarantee that the information contained in this document is free
from third-party industrial property rights. With this document Schulte-Schlagbaum AG does not issue any
licences for its own or third-party patents or other industrial property rights.
Subject to alterations.
SAFE-O-TRONIC is a registered trademark of Schulte-Schlagbaum AG
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC DS
Page 3 of 5
SOT_DS_5020x_Manual.doc
1. Description
Electronic PIN-Code / RFID door locking system, with MIFARE-technology and other RFID-
technologies according ISO 14443 A, with wide possibilities to individualize e. g. room, labelling or
logo by exchangeable cover plates. Adaptable for right and left handed doors. The lock will be re-
leased after entering a 4-6 digit code or using the RFID data medium.
Touchless read and write of the RFID data medium
Time zone to set up limited locking authorizations
Automatically change of authorisation by using a new RFID data medium in case of theft of the
previous RFID data medium
Automatically daily organisation of limited authorisations in combination with online terminals
(CyberSpots)
Locking authorisations can be changed at any time
Quick programming of the lock with help of RFID data medium or communicator
Individual release and blocking of RFID data medium with 254 locking sequences each
RFID data medium with MasterKey-Function to open and close
Emergency Opening with help of RFID data medium in case the user has lost his RFID data
medium
RFID data medium with MasterKey-Function, with limited locking authorizations for the whole
locking system and for defined areas within a locking system
Audit trail for 500 operations
Automatic wake-up of the electronic by approaching with RFID data medium
Easy integration in existing systems (e.g. RFID door locking systems, guest management sys-
tems, parking, wellness etc.) or other data systems (time and attendant systems, member soft-
ware, access control, hotel front office systems or cashless payment)
Battery at the outside of the locker door
Battery life time: approx. 3 years (by 30 cycles per day)
Intelligent battery management system: permanent battery control ensures to open the locker
door at any time
robust metal housing
Certified security against break-up
Suitable for all kind of door materials
No cabling required
Suitable for wet areas, protected against spray water (IP 43)
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC DS
Page 4 of 5
SOT_DS_5020x_Manual.doc
2. Technical data
Protection class according to
DIN EN 60529
IP 43
Weight
approx. 750 g
Temperature range
in use
in storage
0 °C
-15 °C
to
to
60 °C
60 °C
Relative air humidity
10 %
(to)
90 % (without condensation)
Battery
Battery pack: 3 x alkaline cells (AAA)
Battery life
Approx. 3 years at 30 lockings per
Transponder type used
Mifare, ISO 14443 A
Buzzer
integrated
Signal alerts
2 red LED
2 green LED
Colour of housing frame
stainless steel
Colour of the control panel
Black
Dimensions (W x H x D)
204 x 55 x 21 mm
3. Approval
Radio
- Europa
- USA
EN 300 330
FCC 47 CFR Part 15
EMC
EN 300 489
Safety
- Low-Voltage
- Human Exposure
EN 60950
EN 50364
Waste and Hazardous
Substances
RoHS - 2002/95/EC
WEEE - 2002/96/EC
4. Declaration of Conformity for USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired op-
eration. Usually this is followed by the following FCC caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC DS
Page 5 of 5
SOT_DS_5020x_Manual.doc
5. Dimensions
Housing dimensions
Fixing dimensions
SAFE-O-TRONIC
®
access
Electronic Identification and Locking System
LS100, LS 200, LS 300, LS 400
MANUAL
Schulte-Schlagbaum AG
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC LS
Page 2 of 6
SOT_LS_30084x_Manual.doc
Note
Copyright 2011 by
Schulte-Schlagbaum AG
Nevigeser Straße 100-110
Postfach 101240
D-42512 Velbert
Tel.: +49 2051 2086 / 0
FAX: +49 2051 2086 / 918
www.sag-schlagbaum.com
Edition: 04/2011 V1.0 - Document number:
SOT_LS_30084x_Manual.Doc
This edition replaces all earlier editions.
The information in this document may be changed without notice.
Relaying and duplication of this document and the exploitation and communication of its contents
are not permitted unless expressly allowed. Violations shall obligate to provide compensation for
damages. All rights reserved in the event of patent grant or registration of a utility model or design.
The information in this manual has been put together to the best of our knowledge.
Schulte-Schlagbaum AG does not issue a guarantee for the correctness and completeness of the details in
this manual. In particular, Schulte-Schlagbaum AG cannot be made liable for consequential damages due to
incorrect or incomplete details. As errors can never be completely avoided in spite of all efforts, we would be
grateful for your feedback at any time.
The installation recommendations in this document pre-suppose the most favourable general conditions.
Schulte-Schlagbaum AG shall not issue a guarantee for the proper function in environments alien to the sys-
tem.
Schulte-Schlagbaum AG shall not issue a guarantee that the information contained in this document is free
from third-party industrial property rights. With this document Schulte-Schlagbaum AG does not issue any
licences for its own or third-party patents or other industrial property rights.
Subject to alterations.
SAFE-O-TRONIC is a registered trademark of Schulte-Schlagbaum AG
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC LS
Page 3 of 6
SOT_LS_30084x_Manual.doc
1. Description
Electronic PIN-Code / RFID locking system for lockers, safe-deposit boxes and functional furniture,
with MIFARE-technology and other RFID-technologies according ISO 14443 A, round rotary knob
to operate the locking cam and wide possibilities to individualize e. g. locker numbers, writing or
logo by exchangeable plates. Suitable for locker doors, which are originally prepared for cylinder
lever locks. Adaptable for right and left handed locker doors in four different mounting directions.
The lock will be released after entering a 4-6 digit code or using the RFID data medium.
Operation mode: „free locker mode“ and „fixed locker mode“
Touchless read and write of the RFID data medium
Time zone to set up limited locking authorizations
Automatically change of authorisation by using a new RFID data medium in case of theft of the
previous RFID data medium
Automatically daily organisation of limited authorisations in combination with online terminals
(CyberSpots)
Set up for automatically blocking in case of exceeding the programmed time
Set up for automatically opening in case of exceeding the programmed time
Locking authorisations can be changed at any time
Quick programming of the lock with help of RFID data medium or communicator
Individual release and blocking of RFID data medium with 254 locking sequences each
RFID data medium with MasterKey-Function to open and close
Emergency Opening (only opening) with help of RFID data medium in case the user has lost his
RFID data medium
RFID data medium with MasterKey-Function, with limited locking authorizations for the whole
locking system and for defined areas within a locking system
Audit trail for 500 operations
Automatic wake-up of the electronic by approaching with RFID data medium
Manual possibility to unlock ensures functional safety also in case of jammed locker doors
Convenient user guidance by Free- / -- Occupied display as well as optical and acoustic signal
Easy integration in existing systems (e.g. RFID door locking systems, guest management sys-
tems, parking, wellness etc.) or other data systems (time and attendant systems, member soft-
ware, access control, hotel front office systems or cashless payment)
Battery at the outside of the locker door
Battery life time: approx. 3 years (by 30 cycles per day)
Intelligent battery management system: permanent battery control ensures to open the locker
door at any time
robust metal housing
Certified security against break-up
Suitable for all kind of door materials
No cabling required
Suitable for wet areas, protected against spray water (IP 43)
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC LS
Page 4 of 6
SOT_LS_30084x_Manual.doc
2. Technical data
Protection class according to
DIN EN 60529
IP 43
Weight
approx. 300 g
Temperature range
in use
in storage
0 °C
-15 °C
to
to
60 °C
60 °C
Relative air humidity
10 %
(to)
90 % (without condensation)
Battery
Battery pack: 3 x alkaline cells (AAA)
Battery life
Approx. 3 years at 30 lockings per
Transponder type used
Mifare, ISO 14443 A
Buzzer
integrated
Signal alerts
2 red LED 2 green LED
Colour of housing frame
Similar to RAL 9006 (white aluminium)
Colour of the control panel
Black
Dimensions (W x H x D)
151 x 38 x 33 mm
3. Approval
Radio
- Europa
- USA
EN 300 330
FCC 47 CFR Part 15
EMC
EN 300 489
Safety
- Low-Voltage
- Human Exposure
EN 60950
EN 50364
Waste and Hazardous
Substances
RoHS - 2002/95/EC
WEEE - 2002/96/EC
4. Declaration of Conformity for USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference re-
ceived, including interference that may cause undesired operation.
Usually this is followed by the following FCC caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate this equipment.
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC LS
Page 5 of 6
SOT_LS_30084x_Manual.doc
5. Dimensions
Preparation of the door
SAFE-O-TRONIC
access
Manual
SAFE-O-TRONIC LS
Page 6 of 6
SOT_LS_30084x_Manual.doc
6. System Delivery Contents
1
Lock
2
Nut
for mounting the lock on the door
3
Grommet
for setting the rotational direction of the rotary knob in order to lock
4
Locking lever
(a cropped or hook-shaped locking lever can also be used depending on the
properties and condition of the cabinet)
5
Fastening screw
for locking lever
6
Bush fo
r fastening the lock to the door for door thicknesses of
10mm to 18mm
7
Bush fo
r fastening the lock to the door for door thicknesses of
1mm to 9mm
8
Screw
for fastening the lock to the door
9 Rotary knob