PDF User Manual

  1. Home
  2. Manuals
  3. NUWEIGH KCA 1100 Full Manual

NUWEIGH KCA 1100 Full Manual

Made by: NUWEIGH
Type: Full Manual
Category: Monitor
Pages: 16
Size: 1.01 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

Full Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NUWEIGH 

Large Remote Display 

KCA 1100 

Version 1.23.0

 

 

Full  

Manual

 

 

 


background image

 

 

Full Manual 

 

VERSION ISSUED 

 

Date Issued 

Version 
No. 

Description 

Revised 
By 

Approved 
By 

3

rd

 April 2008 

1.8.0.0 

 

 

 

7

th

 April 2008 

1.10.0 

Add Toledo 
Remove Avery, JAD 

NW 

 

8

th

 April 2008 

1.10.1 

Updated section 5. 
Removed switch 
0,4,5,6 and updated 
6  

DW 

DW 

8

th

 May 2008 

1.10.2 

Updated section 5.  
add switch 6 

– 

Mettler Toledo 

DW 

DW 

2

nd

 June 2008 

1.10.3 

Updated section 5 

DW 

DW 

26

th

 August 2008 

1.11.0 

Updated Section 5. 
Added 14 (E) 
JAC320 FV Format 

DW 

DW 

30

th

 Oct 2008 

1.12.0 

Update Section 5. 
to add Scale 
formats 17 & 18 

DW 

DW 

24

th

 June 2009 

1.15.0 

Update Section 5 to 
add Scale format 19 

DW 

DW 

25

th

 March 2010 

1.19.0 

Updated Rinstrum 
5230 Format 

DW 

DW 

9

th

 August 2010 

1.21.0 

Added Format 20 
for JAC350 Axle 
Weighing 

DW 

DW 

 

13

th

 August 2010 

1.22.0 

Power up without 
going through 
parameters etc 
(Configurable) 

DW 

DW 

8

th

 March 2011 

1.23.0 

Added Format 21 
for Command Batch 
System 

DW 

DW 

 


background image

 

 

Full Manual 

INDEX 

 

 

VERSION ISSUED 

2

 

1

GENERAL INSTRUCTIONS 

4

 

1.1

 

Working Environment 

4

 

1.2 The front plate 

4

 

2

INSTALLATIONS 

5

 

2.1 Configuration of data communication 

5

 

2.2 Connection Cables 

6

 

2.3 On-Site Installation 

8

 

3

WORKING MODE 

9

 

4. MULTIPLE DISPLAY COMMUNICATIONS 

12

 

5. CONFIGURATION 

13

 

6. SERIAL COMMUNICATIONS PARAMETERS 

14

 

7. UNITS OF MEASURE 

14

 

8. EXPLANATION OF PC MODE 1 

15

 

9. POWERUP WITH NO PARAMETERS DISPLAYED 

15

 

 

 

 


background image

 

 

Full Manual 

1

GENERAL INSTRUCTIONS

 

The  KCA1100  Series  LED  remote  displays  provide  high-visibility,  six-digit  display  capability  for 
use in  a  wide  variety of applications. This manual provides general installation and configuration 
instructions for the KCA1100. 
The waterproof enclosure of stainless steel enables the KCA1100 to work in rug environment. The 
detachable sunlight shelter makes the display suitable for both indoor and outdoor uses. 
The  specially  designed  brackets  make  it  possible  and  easy  to  install  the  KCA1100  on  different 
places such as the ceiling, the wall and a pole etc. 
   

W a r n i n g :   So m e   p ro c e d u r e s   d e s c ri b e d   i n   t h i s   m a n u a l   r e q u i re   w o rk   i n s i d e  
t h e   d i s p l a y  e n c l o s u r e .   T h e s e   p ro c e d u r e s   a r e   t o   b e   p e rf o rm e d   b y  q u a l i f i e d  
s e rv i c e   p e r s o n   o n l y .  

  

1.1  WORKING ENVIRONMENT 

1 . T e m p e r a t u r e  

- 1 0 ~ 4 0

 

2 . H u m i d it y     

9 5 % R . H  

3 . P o w e r   s u p p l y

A C 1 1 0 V ~2 4 0 V( + - 1 0 % )     5 0 - 6 0 H z  

4 . D a t a   i n p u t    

R S 2 3 2 / 4 8 5 , 0 - 2 0 m Ac u r r e n t   l o o p ,   a n d  

S yn c h r o n o u s   s e r i a l  d a t a   in p u t .  

6 . I n s t a l l a t i o n   D im e n s i o n s

 

9 2 2 m m ×2 4 0 m m ×6 1 m m ( wi t h o u t   s u n l i g h t   s h e lt e r )  
9 2 6 m m ×2 4 2 m m ×2 0 0 m m ( wi t h   s u n l i g h t   s h e lt e r )  

1.2 THE FRONT PLATE 

 

T h e   f r o n t   p la t e   ( T h e   d a r k   b la c k   p a r t   c o n s is t s   o f   L ED s

)  

GROSS:

 

When the LED’s above light, the following six digits show gross weight. 

N ET :  

When enabled, the following six digits show net weight. 

MOTION: 

When this indicator lights, it means the current load is not s t a b l e .  

U n i t s   i n d i c a t o r s :  

t

   

—— Meas ur ing in tonnes .  

k g

   

—— Meas uring in k ilogr am s.

 

 

8. 8. 8. 8 .8 .8 

 


background image

 

 

Full Manual 

 2

INSTALLATIONS 

2.1 CONFIGURATION OF DATA COMMUNICATION 

K C A1 1 0 0  

h a s   t h r e e   k in d s   o f   c o m m u n ic a t i o n :    

R S 2 3 2 / 4 8 5 ,   0

2 0 m A   c u rr e n t   l o o p   a n d   s e r i a l  

s y n c h r o n o u s   p r o t o c o l s .  

 

O p e n   t h e   c o v e r   p l a t e   a t   t h e   le f t   b o t t o m   o f  

K C A1 1 0 0

a n d   p u l l  d o w n   t h e   b o a r d   s h o w n   a s   l e f t  

f ig u r e .   Yo u   c a n   c o n f i g u r e   t h e   c o m m u n ic a t i o n  
p r o t o c o ls   b y  c h a n g in g   d i p   s w i t c h e s   SW 1 ,  J P 1  
a n d   J P 2 .  

 

1 .     R S2 3 2   P ro t o c o l :

f a c t o r y  d e f a u lt   p r o t o c o l

 

S e t  

SW 1 ( r e d ) ,   J P1   a n d   J P 2  

a s   f o r   R S 2 3 2  

c o m m u n ic a t i o n .  

   

2 .     R S4 8 5

Pr o t o c o l :    

S e t  

SW 1 ( r e d )   J P 1   a n d   J P 2  

a s   f o r   R S4 8 5  

c o m m u n ic a t i o n .    

   

3 .     0

2 0 m AC u r re n t   L o o p :

 

S e t   t h e   SW 1   a s   f o r  

0

2 0 m A  C u r r e n t   L o o p

 

c o m m u n ic a t i o n .  

 

Pl e a s e   n o t e   t h a t   w h e n   u s i n g   0 - 2 0 m A  c u r r e n t   l o o p   c o m m u n i c a t i o n   p ro t o c o l ,  
y o u   n e e d   t o   p o w e r  o n   t h e   K C A1 1 0 0   f i r s t   a n d   t h e n   p o w e r  o n   t h e   i n d i c a t o r  

c o n n e c t e d   t o   t h e   d i s p l a y .  

 

4 .     S y n c h ro n o u s   Se r i a l   C o m m u n i c a t i o n :  

S e t   t h e   SW 1

B l u e

a s   f o r   S yn c h r o n o u s   Se r i a l  

c o m m u n ic a t i o n .  
 

N o t e :   P l e a s e   r e s e t   t h e   re m o t e   d i s p l a y   b y   p o w e r  o f f   a n d   o n   w h e n e v e r  t h e  
c o m m u n i c a t i o n   p r o t o c o l   o r  b a u d   r a t e   w a s   c h a n g e d   t o   m a k e   yo u r   n e w  
c o n f i g u r a t i o n   e n a b l e d .  

 

 


background image

 

 

Full Manual 

 

 

2.2 CONNECTION CABLES 

K C A1 1 0 0  

h a s   t w o   c o n n e c t io n   c a b le s   a s   s h o w n   b e l o w .   T h e   l e f t   o n e   ( 4 P   t e r m in a l)  

is   f o r   d a t a   i n p u t   a n d   t h e   r ig h t   o n e   ( 2 P   t e r m i n a l)   is   f o r   p o w e r   s u p p l y.    
A ls o ,   i n   t h e   p o w e r ,   yo u   m u s t   p a y  a t t e n t i o n   t o   t h e   c o n n e c t io n s   o f   A C - I N   ( 3 P 
t e r m i n a l)   a n d   D C - O U T   ( 2 P   t e r m in a l)   w h ic h   c o n n e c t s   w i t h   D C - I N   ( 2 P  t e r m in a l )   o f  
t h e   m a in b o a r d .   T h e   p i c t u r e   is   a s   f o l l o ws .    

 

Warning

  

When connecting to KCA1100 system, please be caution with power 

polarity. We are not responsible for any damage caused by incorrect power polarity 
connection. 

 

 

T h e r e   a re   t w o   p l a c e m e n t   m o d e s :  

( 1 )  Y o u   c a n   f i x   t h e   p o w e r  o n   t h i s   d i s p l a y   a n d   w e   h a v e   t r e p a n n e d   t w o  

h o l e s   u n d e r  i t .   J u s t   s c r e w   d o w n   b y   s c re w d ri v e r .   P i c t u re  

 

i s   a s   f o l l o w s .    

( 2 )  Y o u   c a n   a l s o   p l a c e   t h e   p o w e r  w h e r e   y o u   w a n t .   P i c t u r e  

  i s   a s  

f o l l o w s .  

 
 
 
 
 

 
 
 
 
 
 

 

 


background image

 

 

Full Manual 

 
D a t a   I n p u t   C a b l e :  

T h is   is   a   4 - w ir e   c a b l e ,   a n d   t h e   c o n n e c t i o n   is   d if f e r e n t   f o r   d if f e r e n t  

c o m m u n ic a t i o n   p r o t o c o ls  

 

1

F o r   R S 2 3 2   ,  

t h e   c o n n e c t i o n   b e t w e e n   t h e   d is p l a y  a n d   a n   i n d ic a t o r   o r   P C   is  

a s   d e p ic t e d   a s   b e l o w

 

 

   

2

F o r  R S4 8 5 ,   t h e   c o n n e c t i o n   b e t w e e n   t h e   d i s p l a y   a n d   a n   i n d i c a t o r  i s   a s  

d e p i c t e d   a s   b e l o w

 

 

 
   

3

F o r   0

2 0 m AC u r r e n t   L o o p ,  

t h e   c o n n e c t i o n   is   a s   b e lo w .  

   

 

   
 
 
 

4

F o r   S yn c h ro n o u s   S e r i a l ,  

t h e   c o n n e c t i o n   is   a s :  

 

 

 

DB9 connection for 
PC connection 

5  4  3  2  1 
  9  8  7  6

 

   

 TX

   

 G

N

   

 R

XD

 

   

+5V

 

 


background image

 

 

Full Manual 

2.3 ON-SITE INSTALLATION 

K C A1 1 0 0  

r e m o t e   d is p la y  c a n   b e   in s t a l l e d   o n   a   w a l l,   a   p o l e   a n d   h a n g   f r om  

c e il i n g .   T h e   in s t a l l a t i o n   d im e n s io n s   a r e   a s :  

 

   

K C A1 1 0 0   I

n s t a l l a t i o n   D im e n s i o n s  

 

T h e   M

6  dilatant’s  scr ews  are  suggested  if  you  want  to  ins tall  the  KCA1100  to 

t h e   w a l l .   P l e a s e   r e f e r   t o   t h e   s u g g e s t e d   i n s t a l la t io n   e x a m p l e   a s   f o ll o ws .  

 

   
   

 


background image

 

 

Full Manual 

3

WORKING MODE 

W he n   t h e  

K C A1 1 0 0  

is   p o w e r e d   o n ,   it   e n t e r s   s e lf   t e s t   m o d e .    

 

   

 
 
 
 
T h is   is   t h e   S o f t w a r e   v e r s io n .  
 
 

 
 
 
T h is   is   t h e   b a n d   r a t e   ( 1 2 0 0 / 2 4 0 0 / 4 8 0 0 / 9 6 0 0 / 1 7 2 0 0 ) .  
 
 
 
 
 
T h is   is   t h e   p a r i t y.  
 
 
 

 
 
T h is   t h e   d a t a   b i t s .  
 
 
 
 
 
 
T h is   is   t h e   c o n f ig u r e d   f o r m a t .   R e f e r   t o   T a b l e   # 1  
 
 
 
 

 

F  

–  I . 5 . O . O 

  

 

b    a    u    d 

  

 

1    2    0   0 

  

 

P  A  r  -  n 

  

 d   b    -    8 

Par-N = no parity 
Par-E = even parity 
Par-0 = odd parity 

Db-8 = 8 data bits 
Db-7 = 7 data bits 

  

 S   c    -    9 

 

  

8 . 8 . 8 . 8 . 8 

.8 

 


background image

 

 

Full Manual 

10 

I f

 

t h e  

K C A1 1 0 0

  is   c o n n e c t e d   a n d   c o n f i g u r e d   c o r r e c t l y,   i t   w il l  d i s p la y  t h e   d a t a  

c o m in g   f r o m   t h e   i n d ic a t o r   a b o u t   5 ~ 1 5   s e c o n d s   a f t e r   s e lf   t e s t .    

   

 

   

I f   t h e r e   is   a n yt h in g   w r o n g   w i t h   c o n n e c t io n   t o   t h e   i n d ic a t o r   o r   wr o n g   d a t a   f r o m  
the indic ator , the dis pla y will dis pla y ― Err  - to  ‖  . 

 

If the data is negative, the left m ost digit will be ―

‖. 

 

 

I f   t h e   d is p l a y 

s how― Err -Ur‖, that m eans  data  under r ange . 

 

   

I f   t h e   d is p l a y  s h o w s   E r r - O r ,   t h a t   m e a n s   d a t a   o v e r   r a n g e .

 

 
 
 
 
 
 

kg 

   E r   r   -   t 0    

kg 

E r r    -   U r 

E r r    -   0 r 

 

  

6 4  1 2 . 5 

 

  

8 8 9 . 5 

 


background image

 

 

Full Manual 

11 

E x a m p l e s   o f   d i s p l a y i n g   d a t a :  
   

1 )   G r o s s   w e ig h t ,   U n s t a b l e ,   I n p u t   D a t a   =

6 4 1 2 . 5  

k g

 

   

 

2   )   N e t   w e i g h ,   S t a b l e ,   I n p u t   d a t a   = 

3 6 4

  k g

 

   

 

3

N e t  W e ig h t ,   S t a b l e ,   I n p u t   D a t a   = 

1 9 8 0   k g

 

   

 

   

4

N e t  W e ig h t ,   U n s t a b l e ,   I n p u t   d a t a   =  

- 7 . 3   k g

 

   

 

   

kg 

kg 

 

  

6 4 1 2 . 5 

 

  

3 6 4 

 

 

1 9 8 0 

 

 

7  . 3 

 


background image

 

 

Full Manual 

12 

 
 

4. MULTIPLE DISPLAY COMMUNICATIONS 

This feature is an optional function of KCA1100 Remote Display. Please note that if you need this 
function, you need to inform our company you’re your purchase order to make sure this optional 
function is installed in the factory. 

With  this  function,  you  can  send  and  display  different  message  onto  multiple  KCA1100  Remote 
Displays that are linked with one cable.  

4.1 Settings of SW2 

 

For multiple displaying, please set the SW2 as: 

SW2 

I D  

1  

2  

3  

4  

5  

6  

O F F   O F F   O F F   O F F   O F F   O F F  

* **  

O F F   O F F   O F F   O F F   O F F  

O N  

0 1  

O F F   O F F   O F F   O F F  

O N  

O F F  

0 2  

O F F   O F F   O F F   O F F  

O N  

O N  

0 3  

……  ……  ……  ……  ……  …… 

…… 

O N  

O N  

O N  

O N  

O N  

O F F  

6 2  

O N  

O N  

O N  

O N  

O N  

O N  

* **  

Here, the ID can be coded from 01 to 62. When set to ―***‖ (all ON or all OFF), it disables Multiple 

Display function and returns to normal working mode.  

 

 

 

 

 

 

 


background image

 

 

Full Manual 

13 

5. CONFIGURATION 

Scale selection is performed by selecting various positions on the rotary switch (S2). 

Table #1 

 

Scale 

Format 

 

Switch 

Position 

 

J3     On/Off 

 

Brand 

 

Format 

 

Notes 

OFF 

PC Format 

 

 

OFF 

Nuweigh 

JAC101 AND 151/301 

 

OFF 

Nuweigh 

JAC320 & Nuweigh 
JAC330 

Requires SB-400 Format 

OFF 

Mettler Toledo 

Standard Continuous 

Disable Checksum 
Character 

OFF 

Gedge  

C2 Format 

Bd = 06 

Be = 06 

PA = 0 

SP = C3n

 

OFF 

Gedge 

C3 Format 

Bg = STX($02) 

En = ETX($03) 

OFF 

Rinstrum/Range 

Format –A 

 

10 

OFF 

Rinstrum/Range 

Format –B 

 

11 

OFF 

Rinstrum/Range 

Format –C 

 

12 

OFF 

PC Mode 1 (Stx,Etx) 

 

See 

Point 8

 in this manual 

13 

OFF 

 

 

 

14 

OFF 

Nuweigh 

JAC320 

AND FV Format 

15 

OFF 

 

 

 

16 

ON 

Rinstrum 5230 Axle 
Weigher 

 

 

17 

ON 

Avery 

r-disp 

NOTE: 

 

The data being transmitted to the 

remote display does not have a 
motion flag. 

 

The data being transmitted to the 

remote display does not have an 
under or over range flag.

 

18 

ON 

Scale Manufacturer 
Association 

 

 

The indicator should be set to 
the “<LF>W<CR>” Serial 
Type 

19 

ON 

Bilanciai D800 

Extended 

 

20 

ON 

Nuweigh JAC350 Axle 
Weighing 

JAC350 SB-400 

For displaying Flashing Total 
when used with JAC350 Axle 
weighing firmware 

21 

ON 

Command Batch Control 
System 

 

Displays weight and product code 
as transmitted by command batch 
system. 

 


background image

 

 

Full Manual 

14 

 

6. SERIAL COMMUNICATIONS PARAMETERS 

Dip switches are used to select the required communications parameters. 

BLUE

 6 Way Dip Switch 

SW1 - OFF= No Parity Check,  ON = Parity Check 

SW2 - OFF= ODD Parity,          ON = Even Parity 

SW3 - OFF= 7 Data Bits,           ON = 8 Data Bits 

Table #2 

Switch 

SW4 

SW5 

SW6 

1200 

OFF 

OFF 

OFF 

2400 

ON 

OFF 

OFF 

4800 

OFF 

ON 

OFF 

9600 

ON 

ON 

OFF 

19200 

OFF 

OFF 

ON 

 

 

 

 

Ethernet 

ON 

ON 

ON 

 

Note: 

If the switch selection is changed with the power 

ON

. The display will show the newly selected 

parameters. 

If the switches are changed too quickly, prior to the display complet

ing it’s update.  The incorrect 

parameters may be selected.  If unsure, please press the reset button or turn the power 

OFF/ON

 

7. UNITS OF MEASURE

  

The KCA1100 has the abi

lity to display ―kg‖ or ―t‖. To display ―t‖ ensure the jumper is installed 

across J2 on the top of PLB.  To display ―kg‖ remove the jumper from pins J2 on the top of PCB. 

 


background image

 

 

Full Manual 

15 

 

8. EXPLANATION OF PC MODE 1 

 

1.  Pc Mode 1 allows alpha and numeric messages to be sent from a PC to the KCA1100 

2.  If a message is sent to the KCA1100 that is Six Characters or less this message will be 

displayed statically. 

3.  If a message is sent to the KCA1100 that is Seven Characters or more this message will 

be scrolled. 

4.  The message to be displayed is to begin with a STX character (02 Hex [$02]), and end 

with an ETX character (03Hex [$03]). 

5.  A typical message being sent to the display would be [$02] 12.34[$03] 

6.  This would result in 12.34 being displayed on the KCA1100 

7.  To clear the display you can send either of the following: 

a. [$02][$03] 

 

i.e No characters just a STX and ETX. 

b. [$02]^^^^^^[$03]  

Where ^^^^^^ = spaces. 

8.  Due to limitations of using seven segment displays some characters can not be displayed. 

Some characters will be automatically converted into lower or upper case to allow the 
message to be displayed. 

9.  Example: Darren is displayed as DArrEn 

10.  The Available character set is: 

0,1,2,3,4,5,6,7,8,9 

A,b,C,c,D,d,E,F,g,H,h,I,I,J,j,K,k,N,O,o,P,R,r,S,T,t,U,u,Y,Z. 

 

 

9. POWERUP WITH NO PARAMETERS DISPLAYED 

This option will allow the display to power up and instantly display a weight instead of doing a 
display test and then displaying the configurable parameters. 

 

To change this press the SETUP button on the Daughterboard PCB, the display will show  
StArtuP On or StArtuP OFF. When set to StArtuP On a display test and the configurable 
parameters will be displayed when power is applied. When set to StArtuP OFF a weight will be 
displayed immediately after power on.

 


background image

 

 

Full Manual 

16 

 

 

 

 

 

 

 

 

NEWCASTLE WEIGHING 

SERVICES PTY LTD 

Head Office 

104-114 Hannell St 

WICKHAM  NSW  2293 

 

Phone: 02 4961 4554 

Fax: 02 4962 1137 

www.nws.com.au

 

 

For Order Free Call 

1800 684 554