PDF User Manual

  1. Home
  2. Manuals
  3. Moso SF4.2KTN User Manual

Moso SF4.2KTN User Manual

SF2.2KTN\ SF3.6KTN\ SF1.6KTN\ SF3KTN\ SF4.6KTN\ SF5KTN

Made by: Moso
Type: User Manual
Category: Inverter
Pages: 18
Size: 6.35 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

Solar

 

Family

 

PV

 

Grid-tied

 

Inverter

User

 

Manual

Shenzhen MOSO Electric Co.,Ltd.

R

 


background image

                                                                                                        The Solar Family Series Inverter

I

Table of Contents

1 Notes

....................................................................................................................................................1

1.1 Validity ......................................................................................................................................1
1.2 Target Group..............................................................................................................................1
1.3 Safety .........................................................................................................................................1

2 Introduction

.........................................................................................................................................6

2.1 Overview....................................................................................................................................6
2.2 Electrical Block Diagram...........................................................................................................6
2.3 Terminals of PV Inverter ...........................................................................................................7
2.4 Dimension and Weight ..............................................................................................................8

3 Packaging List

..................................................................................................................................10

4 Technical Data

.................................................................................................................................11

4.1 Input

DC

...........................................................................................................................11

4.2 Output

AC

.........................................................................................................................11

4.3 Efficiency Safety and Protection..............................................................................................12
4.4 General Data ............................................................................................................................12

5 Function

.............................................................................................................................................14

6 Installation

.........................................................................................................................................15

6.1 Safety Instructions ...................................................................................................................15
6.2 Selecting the Installation location............................................................................................15
6.3 Preparation...............................................................................................................................16
6.4Monuting the Bracket ...............................................................................................................16
6.5Mounting the Inverter ...............................................................................................................18
6.6 Check Inverter Installation Status............................................................................................19
6.7 Connector Guide......................................................................................................................19

7 Operation

..........................................................................................................................................23

7.1 LED Display ............................................................................................................................23
7.2 LCD Display............................................................................................................................24

8 Setting up Communication

.............................................................................................................27

8.1 Communication Interface Type ...............................................................................................27
8.2 Communication........................................................................................................................27

9 Troubleshooting

...............................................................................................................................30

10 Decommissioning

..........................................................................................................................32

10.1 Dismantling............................................................................................................................32
10.2 Packaging...............................................................................................................................32
10.3 Storage ...................................................................................................................................32
10.4 Disposal .................................................................................................................................32

11 Warranty

..........................................................................................................................................33

The Solar Family Series Inverter                                                                                                     

1

1 Notes

This manual is an integral part of the inverter. Please read the product manual carefully before 
installation, operation or maintenance. Keep this product manual for future reference.

1.1 Validity

This manual describes the assembly, installation, commissioning and maintenance of the following 
inverters: 

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

1.2 Target Group

This manual is for qualified personnel who have received training and demonstrated skills and 
knowledge in the construction and operation of this device. 
Qualified personnel are trained to deal with the dangers and hazards involved in installing electric 
devices. 

1.3 Safety

1.3.1 Appropriate Usage

The Solar Family Series are the PV inverters which convert the DC current of a PV generator into 
AC current and feed it into the public grid.

Figure 1   

PV Grid-tied System

PV Module

Grid-tied inverter

Grid

 


background image

                                                                                                          The Solar Family Series Inverter

2

1.3.2 Important Safety Instructions

Danger!
Danger to life due to high 

voltages

in the inverter!

·All work on the inverter must be carried out by qualified personnel

only.

·

The inverter is forbidden to be operated by children or persons with 

limited physical  or  mental  capabilities,  persons  who lack  of 
experience and knowledge can only operate the inverter under the 
condition of being given supervision or instruction.

·Children should be supervised to ensure that they do not play with 

the inverter.

Caution!
Danger of burn injuries due to hot enclosure parts!

·During operation, the upper lid of the enclosure and the enclosure 

body may become hot.

·Only touch on the lower enclosure lid is allowed during operation.

Caution!
Possible damage to health as a result of the effects of radiation!

·Do not stay closer to the inverter (beyond 20cm is available) for a 

long time.

Note!

Grounding the PV generator.
·Please recommend PV modules have an IEC 61730 Class A rating.

Please don’t connect the PV modules to GND.

The Solar Family Series Inverter                                                                                                         

3

1.3.3 Glossary of Symbols

This section gives a glossary of all the symbols shown on the inverter and the type label.

Symbols on the inverter 

Symbol

Explanation

Danger to life due to high voltages in the inverter!

There would be residual voltage in the inverter. The inverter requires

1 minute to discharging.

 Wait for 5 minutes before you open the upper lid or the DC lid.

Beware of hot surface.
·The inverter may become hot during operation. Avoid any contact to 

the surface during operation.

Danger of high voltages 
·Danger to life due to high voltages in the inverter!

Risk of electric shock! 
·

Only authorized personnel is allowed to set the DIP switch (SW1).

Requests the user to consult the manual

Indicates caution followed by important instructions

Equipment grounding conductor

AC voltage

You can operate the interface by tapping on it

·

Tapping once: The background illumination switches on.

·

Tapping again: Updating information.

Recovery and recycling.

ISO 7000-1641

Refer to the operating instructions

ISO 7000-0434

Caution,risk of danger

 


background image

                                                                                                        The Solar Family Series Inverter

4

Symbols on the type label 

Symbol

Explanation

CE mark.
·The  inverter  complies  with  the  requirements  of  the  applicable  CE

guidelines.

TUV mark.
·The inverter complies with the requirements of the applicable TUV 

guidelines.

SAA mark.
·The inverter complies with the requirements of the applicable SAA
guidelines.

G59 mark.
·The inverter complies with the requirements of the applicable G59 
guidelines.

G83 mark.
·The inverter complies with the requirements of the applicable G83
guidelines.

CQC mark.

The inverter complies with the requirements of the applicable CQC

guidelines.

Safety precaution

When using the product, please do remember the below information to avoid the fire, lightning or 
other personal injury:

Warning!

Ensure that input DC voltage is less than Max. DC voltage.

·Over voltage  may  cause  permanent  damage  to  inverter  or  other 

losses, which will not be included in warranty! 

·This chapter contains important safety and operating instructions. 
·Read and keep this operation Guide for future reference.

The Solar Family Series Inverter                                                                                                     

5

Warning!

· Authorized  service  personnel  must  disconnect  both  AC  and  DC 

power  from  the

SF series  inverter  before  attempting  any

maintenance or cleaning or working on any circuits connected to
the SF series invert

er.

Warning!

·

The photovoltaic array is exposed to sunlight, it supplies DC voltage 

to the inverter.

 


background image

                                                                                                          The Solar Family Series Inverter

6

2 Introduction 

2.1 Overview

Figure 2 

Stereogram

2.2 Electrical Block Diagram

Electrical block diagram

Figure 3 

Electrical block diagram

The Solar Family Series Inverter                                                                                                         

7

.3 Terminals of PV Inverter

Figure 4 

Terminals of PV Inverter (SF1.6KTN/SF2.2KTN/SF3KTN)

Figure 5

Terminals of PV Inverter (SF3.6KTN/SF4.2KTN/SF4.6KTN/SF5KTN)

 


background image

                                                                                                          The Solar Family Series Inverter

8

2.4 Dimension and Weight

Dimension

Figure6

SF1.6KTN/SF2.2KTN/SF3KTN

12

0m

m

342mm

The Solar Family Series Inverter                                                                                                         

9

Figure7

SF3.6KTN/SF4.2KTN/SF4.6KTN/SF5KTN

Weight

Table 1

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Weight [kg]

8

8

8

11

11

11

11

330mm

 


background image

                                                                                                          The Solar Family Series Inverter

10

3 Packaging List   

Table 2

The Solar Family is shipped with the following items:

Figure 8

Item

Name

Quantity

A

Solar Inverter

1

B

Mounting Frame

1

C

Mounting Screws

4

D

Mounting Frame Screws Sleeve

4

E

Mounting Screws

2

F

Manual

1

F

The Solar Family Series Inverter                                                                                                         

11

4 Technical Data

4.1 Input

DC

Table 3

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Max. 

DC 

Power[W]

2200

2800

3600

4400

5000

5400

5800

Max.  DC  power 
each  MPP tracker
[W]

2200

2800

3600

2200/2500/2700/2900

Max. 

DC 

Voltage[V]

550

550

Max.Input
Current of  MPP 
Tracker[A]

11

11

11/11

Number of MPP
Trackers / Strings
per MPP Tracker

1/1

2/1

MPPT Voltage
Range [V]

80-550

80-550

80-550

80-550

80-550

80-550

80-550

Nominal 

PV 

Voltage  [V]

360

360

Start 
Voltage/On-Grid 
Voltage

100/120

100/120

Overvoltage 
category

4.2 Output

AC

Table 4

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Max. 

AC 

Power[W]

1600

2200

3000

3600

4200

4600

5000

Max.  AC  Current 
[A]

7.3

10

13.7

16.4

19.1

20.9

22.7

Nominal 

AC 

Voltage [V]

220/230/240

220/230/240

AC 

Voltage 

Range [V]

80-300

80-300

AC 

Grid 

Frequency [Hz]

50/60

50/60

 


background image

                                                                                                        The Solar Family Series Inverter

12

Power 

Factor 

(cos

φ

)

0.8lagging-0.8leading

0.8lagging-0.8leading

THD

(at 

nominal 

power)

<3%

<3%

Overvoltage 
Category

*Maximum Output power limited to 16amps up to a maximum power of 3.6KW, for G83.

Maximum Output power limited to 18amps up to a maximum power of 3.6KW, for G59.

4.3 Efficiency Safety and Protection

Table 5

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Max. Efficiency

97.5%

97.5%

97.5%

98%

98%

98%

98%

Euro-Efficiency

97.0%

97.0%

97.0%

97.6%

97.6%

97.6%

97.6%

MPPT Efficiency

99.9%

99.9%

Overvoltage 

Under-
Voltage Protection

Yes

Yes

Shutdown
Voltage  /  Start
Voltage

Yes

Yes

DC 

Isolation 

Impedance 
Monitoring

Yes

Yes

Ground Fault
Protection

Yes

Yes

Grid Monitoring

Yes

Yes

Ground 

Fault 

Current
Monitoring

Yes

Yes

DC Injection
Monitoring

Yes

Yes

4.4 General Data

Table 6

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Dimension(W/H/
D) [mm]

340/330/120

340/398/120

Weight [kg]

8

8

8

11

11

11

11

Cooling Concept Natural Convection

Natural Convection

The Solar Family Series Inverter                                                                                                     

13

Noise  (typical) 
[dB]

25dB

25dB

Operating 
Temperature 
Range [°C]

-25

℃~

+60

/derating at 45

-25

℃~

+60

/derating at 45

Relative humidity 
range

0% ~ 100% (condensing)

0%~ 100% (condensing)

Pollution Degree External (III) Internal (II)

External (III) Internal (II)

Protective class

Class

Class

Degree 

of 

Protection

IP65

IP65

Topology

Transformerless

Transformerless

Internal 
Consumption(  ni
ght ) [W]

<0.5W

<0.5W

LCD display

opt

opt

Communication 
Interfaces

RS485/ WiFi optional

RS485/ WiFi optional

Standard 
Warranty

6/10/15 years
Free/opt./opt.

6/10/15 years
Free/opt./opt.

 


background image

                                                                                                          The Solar Family Series Inverter

14

5 Function

Fault Mode

If any fault/error occurs, inverter stops generating power until the fault/error is cleared. Some 
fault/error will recover itself, and some may need to restart manually to resolve. 

CAUTION! 

The  inverter  output  power  decrease  is  usual 

under

the  condition  of  thermal 

protection, but if it occurs frequently, you need to check the heat sink or consider 
putting  the  inverter  in  the  place  where  have  better  air  flow,  and  if  output  power 
decreases caused by electrical problem, please ask for professional supports.

The Solar Family Series Inverter                                                                                                         

15

6 Installation

6.1 Safety Instructions

Do not remove the enclosure upper lid. Inverter contains non-user practical parts. All wiring and 
electrical installation should be conducted by a qualified service personnel and must meet national 
requirements.
Both AC and DC voltage sources are terminated inside the PV Inverter. Please disconnect these 
circuits before servicing. 
When a photovoltaic panel is exposed to sunlight, it generates DC voltage. When connected to this 
equipment, a photovoltaic panel will charge the DC capacitors.
Energy stored in this equipment’s DC capacitors presents a risk of electric shock. Even after the 
unit is disconnected from the grid and photovoltaic panels, high voltages may still exist inside the 
PV-Inverter. Do not remove the upper lid until at least 5 minutes after disconnecting all power 
sources. 
This unit is designed to feed power to the public power grid only. Do not connect this unit to an AC 
source or generator. Connecting inverter to external devices could result in serious damage to your 
equipment. 
Carefully remove the unit from its packaging and inspect for external damage. If you find any 
imperfection, please contact with your local distributor or service center. 
Although designed to meet all safety requirements, some parts and surfaces of inverter are still hot 
during operation. To reduce the risk of injury, DO NOT touch the heat sink at the back of the 
PV-Inverter or nearby surfaces while Inverter is operating.
Check environment where system is installed.
Check whether the installation site fall into any of the following conditions:

 The ambient temperature is beyond the range of the optional temperature limitation. ( -25°C to 

+60°C, -13°F to +140°F),(Power derating begins at 45°C).

 Installation altitude is higher than 2000m.

 Prone to be damaged by sea water

 Close to corrosive gas or liquid (for example, locations where chemicals are processed or the 

location where feed lots of poultry).

 Exposed to direct sunlight.

 Prone to be damaged in flooding or icing time

 Little air flow or high humidity.

 Exposed to steam, vapor, or water.

 Exposed to direct cool air.

 Close to the television antenna or antenna cable.

6.2 Selecting the Installation location

The installation method and mounting location must be suitable for the weight and dimensions of 
the inverter. Select a wall or solid vertical surface which is able to support the PV Inverter. 
Mount on a solid surface, the mounting location must be accessible at all times. 
Vertical installation or tilted backwards by max. 15°.
The connection area must point downwards.

 


background image

                                                                                                          The Solar Family Series Inverter

16

Do not install horizontally.

Figure 9

6.3 Preparation

Below tools are needed before installation.

Figure 10

Installation Tools

6.4 Mounting the bracket

Inverter requires adequate cooling space. Allow at least 20cm space above and below the inverter.

Figure 11

The Solar Family Series Inverter                                                                                                         

17

Using the mounting frame as a template, drill 3 holes as illustrated in image   

Figure 12

Figure 13

20CM

20CM

20CM

20CM

 


background image

                                                                                                          The Solar Family Series Inverter

18

6.5 Mounting the Inverter

Hang the inverter onto the mounting frame.

 

Figure 14

Insert safety- lock screws into the bottom leg to fasten the inverter.

The Solar Family Series Inverter                                                                                                         

19

Figure 15

6.6 Check Inverter Installation Status

Check the upper straps of Inverter to ensure it is fixed on to the bracket
Check the secure mounting of the PV-Inverter by trying to raise it from the bottom. 
The PV-Inverter should remain firmly attached. 
Select the installation location so that the status of display can be easily viewed.
Choose a strong mounting wall to prevent vibrations while inverter is operating.

6.7 Connector Guide

This product has a professional IP68 DC waterproof connector. You have to wire DC by yourself. 
Please see

Figure 16

and

Figure 17

for DC connector disassembling guide.

Connectors must only be connected by qualified personnel

Only PV1-F cables can be used. The TÜV approval only allows the use of PV1-F cables. Do not 
use type H07RN-F cables.

The connectors must be not disconnected while under load. For protection against electric shock, 
connectors must always be disconnected from the power supply during assembly.

Connectors that are not plugged must be protected against humidity and contamination by a 
protective cap. Any kind of contamination may have adverse effect on the system and great care 
must be taken during assembly to ensure that everything is clean.

 


background image

                                                                                                        The Solar Family Series Inverter

20

Connectors provide IP68 protection but should not be continually exposed to water (e.g. immersed 
under water) and not placed directly on the top side.

Connecting to PV panel (DC input):

Figure 16

1. Wire stripping 7mm
2. Insert the wire into the core with pliers pressure;
3. The core penetration into the terminal internal until clamping, then tighten the nut

The Solar Family Series Inverter                                                                                                     

21

Figure 17

Connecting to the grid:

1.

Measure grid voltage and frequency to see whether they are normal.

2.Open the breaker or fuse between inverter and utility grid.
3.Connect AC wires of inverter as follows:

 


background image

                                                                                                          The Solar Family Series Inverter

22

L N

1

2/3

4

5

6

Figure 18

Below is the AC cable specification table when select the cable for installation.

Table 7

Cable and Micro-breaker Requirement

Model

SF1.6KTN

SF2.2KTN

SF3KTN

SF3.6KTN

SF4.2KTN

SF4.6KTN

SF5KTN

Cable (Cu)

2.5mm

2

2.5mm

2

2.5mm

2

4mm

2

4mm

2

4mm

2

4mm

2

Micro-Breaker

16A

20A

20A

25A

25A

25A

32A

The Solar Family Series Inverter                                                                                                         

23

7 Operation

7.1 LED Display

The panel has three LED indicators as follows:

Figure 19

7.1.1 DC/DC status LED (Green)

Table 8

Off

The DC/DC Circuit is off.

Blinking

The DC/DC Circuit is starting.

On

The DC/DC Circuit is working 

normally

7.1.2 DC/AC status LED (Green)

Table 9

Off

The DC/AC Circuit is off.

Blinking

The DC/AC Circuit is starting.

On

The DC/AC Circuit is working 

normally.

7.1.3 Fault LED (Red)

Table 10

Off

No Error occurs

On

The inverter is in fault status

Normally, after starting up, DC/DC LED and DC/AC LED will be lighted indicating that the Inverter's 
feeding power status to the grid. 

NOTE:Wire color requirements    L-Red/N-Black/Gnd-Yellow&Green

 


background image

                                                                                                        The Solar Family Series Inverter

24

7.2 LCD Display

The LCD display monitors the inverter status and collects statistical data for assessing system 
performance.
The display on the inverter can be controlled by key
To save power, the LCD display’s backlight will turn off automatically after 30 seconds. 
A summary diagram of the display functions is shown as the figure below, 

Figure 20 LCD summary diagram of SF1.6KTN, SF2.2KTN, SF3KTN

Figure 21 LCD summary diagram of SF3.6KTN, SF4.2KTN, SF4.6KTN, SF5KTN

7.2.1State Page

State:

Waiting...

Figure 22

Fault Information is listed as the following table

Table 11

Display

Description

Leakage Fault

The internal hardware that measures ground fault has measured 
substantially high ground currents.

Grid Fault

Grid Voltage or Frequency out of range

Boost Fault

Boost(DC/DC) Power Stage fault

PV Over Voltage

PV panel Voltage too high

Relay Fault

The AC relay failed

DCINJ High

Output Current DC Offset too high

RCD Fault

The RCD measurement mechanism has failed during the wake-up 

Setting

State

Power

E-day

Energy

-total

Output

Info

Input

Setting

State

Power

E-day

Energy

-total

Output

Info

Input

The Solar Family Series Inverter                                                                                                     

25

test phase.

Ov Temp

Over temperature

DC Bus High

DC Bus Voltage Fault

Grid Lock Failed

Grid Phase Lock failed

CPU Commu Failed

CPU Communication Fault

Aux Power Fault

+12V Power fault

ISO Fault

Isolation Fault

Inv Fault

Inverter(DC/AC) Power Stage fault

Boost Ov Curr

Boost (DC/DC) Power Stage over current

INVOvCurr

Inverter(DC/AC) Power Stage over current

PVPowerLow

PV Power too low

7.2.3Power&E-day Page

The inverter power&Energy-day will be displayed in this page.

Power: 0 W

E-day:0.00Kwh

Figure 23

7.2.4 Energy-Total Page

The inverter Energy-total will be displayed in this page.

Energy-Total:

0.0Kwh

Figure 24

7.2.5 Input Page

The inverter PV parameter will be displayed in this page.

INPUT:

PV1:360V    0.0A   

Figure 25

7.2.6 Output Page

The inverter AC parameter will be displayed in this page.

OUTPUT:

220V   0.0A   0.00Hz

Figure 26

7.2.7 Setting Page

Setting

Com-Addr

01

Figure 27

7.2.8 Information Page

SN:SF3K016010001

VER: V100 V208

Figure 28

 


background image

                                                                                                          The Solar Family Series Inverter

26

7.2.9 Setting option

Date:16-01-01

Time:08:00:00

Work Mode

Mppt

Max Volt

270V

Max Freq

50.0Hz

P-Limit

100% 

Country

CHN

GFCI:   Disable

RISO:  Disable

State:

Waiting...
Power: 0 W

E-day:0.00Kwh
Energy-Total:

0.0Kwh

OUTPUT:

220V   0.0A   0.00Hz

SN:SF3K016010001

VER: V100 V207

Setting

Com-Addr

01

INPUT:

PV1:360V    0.0A   

Setting

Com-Addr

01

Fault

                  01

01

GridFault

ENTER

Scan

ESC Cancel/OUT

UP

DONW

OK/ENTER

Figure 29

The Solar Family Series Inverter                                                                                                         

27

8 Setting up Communication 

8.1 Communication Interface Type

This  product  has  a  communication  interface

RS485 and 

Serial  Port

(optional).

Operating 

information

such as o

utput voltage, current, frequency, fault information, etc., can be delivered to 

PC or other monitoring equipment vi

a RS485.

8.2 Communication

When user want to know the information of the power station and manage the entire power system. 

We offer below three types of communications.

Figure 30

Communication Interface of SF

Series

Inverter

Table 12

3-line RS485

Wire No.

Function

Serial Port Wire No.

Function

1

A

1

VCC

2

B

2

RXD

3

NC

3

TXD

4

GND

8.2.1

Connect the system by Serial Port/RS485 Adapter

User can use a Serial Port/RS485 to USB Adapter to connect the inverter and the PC, Please note 
that the inverter’s serial port is TTL standard not RS232 standard. Using B&B Data Explorer , the 
inverter’s information can be checked on PC.
Take example of RS485 (

Figure 

35):

Serial Port

RS485

RS485

1

2

3

4

3

1

2

3

2

1

 


background image

                                                                                                        The Solar Family Series Inverter

28

Figure 

31

8.2.2

Webbox Communication (optional)

The connection way between SF Series Inverters are a straight through cable. But the connection 
between  SF  Series Inverters and  Webbox  uses  a  crossover  cable.  As  shown  in  the  following 
figure.

USB

Grid-tied Inverter

RS485

Grid-tied Inverter

RS485

RS485
adapter

PC

The Solar Family Series Inverter                                                                                                         

29

Figure 32

Web Box Monitoring Diagram

8.2.3

Embeded WiFi Communication (optional) 

Embeded WiFi module is a hardware device can be inserted to inverter’s serial port. Please refer 
to WiFi module Manual for more information.

Table 13

1

2

4

3

1
2

3
4

Inverter serial Port 

Connector

WiFi Module

Connector

Figure 33

8.2.4 

Inverter demand response modes(DRMS)

(optional)

The demand response controls(DRC)

module is a hardware device can be inserted to inverter’s 

serial port.

As shown in the following figure 34.

1

2

3

1

2

3

Inverter RS485 

connector

DRED RS485 

connector

Figure 34

The RJ45 socket pin assignments for demand response modes are 

in Table 14.

Pin

Assignment for inverters capable of both charging and discharging

1

Resverve

2

Resverve

3

Resverve

4

Resverve

5

RefGen

6

Com/DRM0

7

V+

8

V-

Table 14

 


background image

                                                                                                          The Solar Family Series Inverter

30

9 Troubleshooting

In most situations,

the inverter requires very little maintenance. 

However, if Inve

rter fails to 

work 

perfectly, please refer to the following instructions before calling your local dealer. 
Should any problem arises, the LED on the front panel will be red and the L

CD will display t

he

relevant  information.  Please  refer  to  the  following  table  for  a  list  of  potential  problems  and
solutions.

Table 15

Troubleshooting list

Faults

Diagnosis and Solutions

Grid Fault

-Waiting for one minute, grid will go back 
to normal working state.
-Making sure that grid voltage and
frequency complies with standards.
-Or, please seek for help from us

-Off to grid.
-Please  check  grid-connection,  like  wire, 
interface, etc.
-Checking grid usability.
-Or seek for help from us. 

PV Over Voltage

-Checking the panel’s open-circuit voltage 
whether  the  value  is close  to or 
already >Max.DC voltage.
-Please seek help from us when voltage 

 

Max.DC voltage.

DCINJ High

-Disconnect the PV (+), PV (-) with DC 
input, then reconnect them.
-Check L line and N line to see whether it 
has connection faults.
-Please seek for help from us when this 
fault happens. 

Relay Fault

-Disconnect the PV (+), PV (-) with DC 
input, then reconnect them.
-Please seek for help from us if it can’t go 
back to normal state. 

*

Self Testing Fault

SF3.6KTN,SF4.2KTN,SF4.6KTN,SF5KTN

-Please check whether working in IN1 & 
IN2 P mode.

-

Check PV1,PV2 if there is no connection

- Or please seek for help from us.

 

Check the warning or fault messages on the information panel. Record the message if displayed 

for further action.

 Try the solution indicated in 

Table 15

.

 If your inverter information panel didn’t have a Fault light, check the following list to make sure 

The Solar Family Series Inverter                                                                                                         

31

that the present state of the installation allows proper operation of the unit.
— Is the inverter located in a clean, dry, ventilated place?
— Have the DC input breakers been opened? 
— Is the size & length of cables suitable?
— Are the input and output connections and wiring in good condition?
— Are the configurations settings correct for your particular installation?
—Are the display panel and the communications cable properly connected without damage?

 


background image

                                                                                                        The Solar Family Series Inverter

32

10 Decommissioning

10.1 Dismantling 

Disconnect the inverter from DC input and AC output.

 Remove all connection cables from the inverter.

 Remove the inverter from the bracket.

10.2 Packaging

If possible, it’s better to pack the inverter with the original packing.
If original packing is not available, please use similar packing which meets below requirements

 Load ability should be over 20kg.

 With handle. 

Able to fully closed.

10.3 Storage

Store the inverter in a dry place where ambient temperature is always between -25

and +60 

.

-13°F to +140°F.

10.4 Disposal

Please put the defective inverters & packing materials to a place which is convenient for relevant 
department to dispose and recycle.

The Solar Family Series Inverter                                                                                                     

33

11 Warranty

Warranty certificate represents a 6 year warranty service for mentioned products since the date of 
purchase.

Warranted Products

This warranty is applicable solely to the following products:

SF1.6KTN SF2.2KTN SF3KTN
SF3.6KTN SF4.2KTN SF4.6KTN SF5KTN

Limited Product Warranty

(Applicable under normal application, installation, use and service conditions.)
SF Series Inverter warrants the above listed products to be free from defects and/or failure 
specified for a period not exceeding 6 years from the date of sale as shown in the roof of Purchase 
to the original purchaser.