Full Text Searchable PDF User Manual
Solar
Family
PV
Grid-tied
Inverter
User
Manual
Shenzhen MOSO Electric Co.,Ltd.
R
The Solar Family Series Inverter
I
Table of Contents
1 Notes
....................................................................................................................................................1
1.1 Validity ......................................................................................................................................1
1.2 Target Group..............................................................................................................................1
1.3 Safety .........................................................................................................................................1
2 Introduction
.........................................................................................................................................6
2.1 Overview....................................................................................................................................6
2.2 Electrical Block Diagram...........................................................................................................6
2.3 Terminals of PV Inverter ...........................................................................................................7
2.4 Dimension and Weight ..............................................................................................................8
3 Packaging List
..................................................................................................................................10
4 Technical Data
.................................................................................................................................11
4.1 Input
(
DC
)
...........................................................................................................................11
4.2 Output
(
AC
)
.........................................................................................................................11
4.3 Efficiency Safety and Protection..............................................................................................12
4.4 General Data ............................................................................................................................12
5 Function
.............................................................................................................................................14
6 Installation
.........................................................................................................................................15
6.1 Safety Instructions ...................................................................................................................15
6.2 Selecting the Installation location............................................................................................15
6.3 Preparation...............................................................................................................................16
6.4Monuting the Bracket ...............................................................................................................16
6.5Mounting the Inverter ...............................................................................................................18
6.6 Check Inverter Installation Status............................................................................................19
6.7 Connector Guide......................................................................................................................19
7 Operation
..........................................................................................................................................23
7.1 LED Display ............................................................................................................................23
7.2 LCD Display............................................................................................................................24
8 Setting up Communication
.............................................................................................................27
8.1 Communication Interface Type ...............................................................................................27
8.2 Communication........................................................................................................................27
9 Troubleshooting
...............................................................................................................................30
10 Decommissioning
..........................................................................................................................32
10.1 Dismantling............................................................................................................................32
10.2 Packaging...............................................................................................................................32
10.3 Storage ...................................................................................................................................32
10.4 Disposal .................................................................................................................................32
11 Warranty
..........................................................................................................................................33
The Solar Family Series Inverter
1
1 Notes
This manual is an integral part of the inverter. Please read the product manual carefully before
installation, operation or maintenance. Keep this product manual for future reference.
1.1 Validity
This manual describes the assembly, installation, commissioning and maintenance of the following
inverters:
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
1.2 Target Group
This manual is for qualified personnel who have received training and demonstrated skills and
knowledge in the construction and operation of this device.
Qualified personnel are trained to deal with the dangers and hazards involved in installing electric
devices.
1.3 Safety
1.3.1 Appropriate Usage
The Solar Family Series are the PV inverters which convert the DC current of a PV generator into
AC current and feed it into the public grid.
Figure 1
PV Grid-tied System
PV Module
Grid-tied inverter
Grid
The Solar Family Series Inverter
2
1.3.2 Important Safety Instructions
Danger!
Danger to life due to high
voltages
in the inverter!
·All work on the inverter must be carried out by qualified personnel
only.
·
The inverter is forbidden to be operated by children or persons with
limited physical or mental capabilities, persons who lack of
experience and knowledge can only operate the inverter under the
condition of being given supervision or instruction.
·Children should be supervised to ensure that they do not play with
the inverter.
Caution!
Danger of burn injuries due to hot enclosure parts!
·During operation, the upper lid of the enclosure and the enclosure
body may become hot.
·Only touch on the lower enclosure lid is allowed during operation.
Caution!
Possible damage to health as a result of the effects of radiation!
·Do not stay closer to the inverter (beyond 20cm is available) for a
long time.
Note!
Grounding the PV generator.
·Please recommend PV modules have an IEC 61730 Class A rating.
Please don’t connect the PV modules to GND.
The Solar Family Series Inverter
3
1.3.3 Glossary of Symbols
This section gives a glossary of all the symbols shown on the inverter and the type label.
●
Symbols on the inverter
Symbol
Explanation
Danger to life due to high voltages in the inverter!
•
There would be residual voltage in the inverter. The inverter requires
1 minute to discharging.
•
Wait for 5 minutes before you open the upper lid or the DC lid.
Beware of hot surface.
·The inverter may become hot during operation. Avoid any contact to
the surface during operation.
Danger of high voltages
·Danger to life due to high voltages in the inverter!
Risk of electric shock!
·
Only authorized personnel is allowed to set the DIP switch (SW1).
Requests the user to consult the manual
Indicates caution followed by important instructions
Equipment grounding conductor
AC voltage
You can operate the interface by tapping on it
·
Tapping once: The background illumination switches on.
·
Tapping again: Updating information.
Recovery and recycling.
ISO 7000-1641
Refer to the operating instructions
ISO 7000-0434
Caution,risk of danger
The Solar Family Series Inverter
4
●
Symbols on the type label
Symbol
Explanation
CE mark.
·The inverter complies with the requirements of the applicable CE
guidelines.
TUV mark.
·The inverter complies with the requirements of the applicable TUV
guidelines.
SAA mark.
·The inverter complies with the requirements of the applicable SAA
guidelines.
G59 mark.
·The inverter complies with the requirements of the applicable G59
guidelines.
G83 mark.
·The inverter complies with the requirements of the applicable G83
guidelines.
CQC mark.
•
The inverter complies with the requirements of the applicable CQC
guidelines.
、
●
Safety precaution
When using the product, please do remember the below information to avoid the fire, lightning or
other personal injury:
Warning!
Ensure that input DC voltage is less than Max. DC voltage.
·Over voltage may cause permanent damage to inverter or other
losses, which will not be included in warranty!
·This chapter contains important safety and operating instructions.
·Read and keep this operation Guide for future reference.
The Solar Family Series Inverter
5
Warning!
· Authorized service personnel must disconnect both AC and DC
power from the
SF series inverter before attempting any
maintenance or cleaning or working on any circuits connected to
the SF series invert
er.
Warning!
·
The photovoltaic array is exposed to sunlight, it supplies DC voltage
to the inverter.
The Solar Family Series Inverter
6
2 Introduction
2.1 Overview
Figure 2
Stereogram
2.2 Electrical Block Diagram
●
Electrical block diagram
Figure 3
Electrical block diagram
The Solar Family Series Inverter
7
.3 Terminals of PV Inverter
Figure 4
Terminals of PV Inverter (SF1.6KTN/SF2.2KTN/SF3KTN)
Figure 5
Terminals of PV Inverter (SF3.6KTN/SF4.2KTN/SF4.6KTN/SF5KTN)
The Solar Family Series Inverter
8
2.4 Dimension and Weight
●
Dimension
Figure6
SF1.6KTN/SF2.2KTN/SF3KTN
12
0m
m
342mm
The Solar Family Series Inverter
9
Figure7
SF3.6KTN/SF4.2KTN/SF4.6KTN/SF5KTN
●
Weight
Table 1
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Weight [kg]
8
8
8
11
11
11
11
330mm
The Solar Family Series Inverter
10
3 Packaging List
Table 2
The Solar Family is shipped with the following items:
Figure 8
Item
Name
Quantity
A
Solar Inverter
1
B
Mounting Frame
1
C
Mounting Screws
4
D
Mounting Frame Screws Sleeve
4
E
Mounting Screws
2
F
Manual
1
F
The Solar Family Series Inverter
11
4 Technical Data
4.1 Input
(
DC
)
Table 3
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Max.
DC
Power[W]
2200
2800
3600
4400
5000
5400
5800
Max. DC power
each MPP tracker
[W]
2200
2800
3600
2200/2500/2700/2900
Max.
DC
Voltage[V]
550
550
Max.Input
Current of MPP
Tracker[A]
11
11
11/11
Number of MPP
Trackers / Strings
per MPP Tracker
1/1
2/1
MPPT Voltage
Range [V]
80-550
80-550
80-550
80-550
80-550
80-550
80-550
Nominal
PV
Voltage [V]
360
360
Start
Voltage/On-Grid
Voltage
100/120
100/120
Overvoltage
category
Ⅱ
Ⅱ
4.2 Output
(
AC
)
Table 4
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Max.
AC
Power[W]
1600
2200
3000
3600
4200
4600
5000
Max. AC Current
[A]
7.3
10
13.7
16.4
19.1
20.9
22.7
Nominal
AC
Voltage [V]
220/230/240
220/230/240
AC
Voltage
Range [V]
80-300
80-300
AC
Grid
Frequency [Hz]
50/60
50/60
The Solar Family Series Inverter
12
Power
Factor
(cos
φ
)
0.8lagging-0.8leading
0.8lagging-0.8leading
THD
(at
nominal
power)
<3%
<3%
Overvoltage
Category
Ⅲ
Ⅲ
*Maximum Output power limited to 16amps up to a maximum power of 3.6KW, for G83.
Maximum Output power limited to 18amps up to a maximum power of 3.6KW, for G59.
4.3 Efficiency Safety and Protection
Table 5
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Max. Efficiency
97.5%
97.5%
97.5%
98%
98%
98%
98%
Euro-Efficiency
97.0%
97.0%
97.0%
97.6%
97.6%
97.6%
97.6%
MPPT Efficiency
99.9%
99.9%
Overvoltage
/
Under-
Voltage Protection
Yes
Yes
Shutdown
Voltage / Start
Voltage
Yes
Yes
DC
Isolation
Impedance
Monitoring
Yes
Yes
Ground Fault
Protection
Yes
Yes
Grid Monitoring
Yes
Yes
Ground
Fault
Current
Monitoring
Yes
Yes
DC Injection
Monitoring
Yes
Yes
4.4 General Data
Table 6
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Dimension(W/H/
D) [mm]
340/330/120
340/398/120
Weight [kg]
8
8
8
11
11
11
11
Cooling Concept Natural Convection
Natural Convection
The Solar Family Series Inverter
13
Noise (typical)
[dB]
≤
25dB
≤
25dB
Operating
Temperature
Range [°C]
-25
℃~
+60
℃
/derating at 45
℃
-25
℃~
+60
℃
/derating at 45
℃
Relative humidity
range
0% ~ 100% (condensing)
0%~ 100% (condensing)
Pollution Degree External (III) Internal (II)
External (III) Internal (II)
Protective class
Class
Ⅰ
Class
Ⅰ
Degree
of
Protection
IP65
IP65
Topology
Transformerless
Transformerless
Internal
Consumption( ni
ght ) [W]
<0.5W
<0.5W
LCD display
opt
opt
Communication
Interfaces
RS485/ WiFi optional
RS485/ WiFi optional
Standard
Warranty
6/10/15 years
Free/opt./opt.
6/10/15 years
Free/opt./opt.
The Solar Family Series Inverter
14
5 Function
【
Fault Mode
】
If any fault/error occurs, inverter stops generating power until the fault/error is cleared. Some
fault/error will recover itself, and some may need to restart manually to resolve.
CAUTION!
The inverter output power decrease is usual
under
the condition of thermal
protection, but if it occurs frequently, you need to check the heat sink or consider
putting the inverter in the place where have better air flow, and if output power
decreases caused by electrical problem, please ask for professional supports.
The Solar Family Series Inverter
15
6 Installation
6.1 Safety Instructions
Do not remove the enclosure upper lid. Inverter contains non-user practical parts. All wiring and
electrical installation should be conducted by a qualified service personnel and must meet national
requirements.
Both AC and DC voltage sources are terminated inside the PV Inverter. Please disconnect these
circuits before servicing.
When a photovoltaic panel is exposed to sunlight, it generates DC voltage. When connected to this
equipment, a photovoltaic panel will charge the DC capacitors.
Energy stored in this equipment’s DC capacitors presents a risk of electric shock. Even after the
unit is disconnected from the grid and photovoltaic panels, high voltages may still exist inside the
PV-Inverter. Do not remove the upper lid until at least 5 minutes after disconnecting all power
sources.
This unit is designed to feed power to the public power grid only. Do not connect this unit to an AC
source or generator. Connecting inverter to external devices could result in serious damage to your
equipment.
Carefully remove the unit from its packaging and inspect for external damage. If you find any
imperfection, please contact with your local distributor or service center.
Although designed to meet all safety requirements, some parts and surfaces of inverter are still hot
during operation. To reduce the risk of injury, DO NOT touch the heat sink at the back of the
PV-Inverter or nearby surfaces while Inverter is operating.
Check environment where system is installed.
Check whether the installation site fall into any of the following conditions:
●
The ambient temperature is beyond the range of the optional temperature limitation. ( -25°C to
+60°C, -13°F to +140°F),(Power derating begins at 45°C).
●
Installation altitude is higher than 2000m.
●
Prone to be damaged by sea water
●
Close to corrosive gas or liquid (for example, locations where chemicals are processed or the
location where feed lots of poultry).
●
Exposed to direct sunlight.
●
Prone to be damaged in flooding or icing time
●
Little air flow or high humidity.
●
Exposed to steam, vapor, or water.
●
Exposed to direct cool air.
●
Close to the television antenna or antenna cable.
6.2 Selecting the Installation location
The installation method and mounting location must be suitable for the weight and dimensions of
the inverter. Select a wall or solid vertical surface which is able to support the PV Inverter.
Mount on a solid surface, the mounting location must be accessible at all times.
Vertical installation or tilted backwards by max. 15°.
The connection area must point downwards.
The Solar Family Series Inverter
16
Do not install horizontally.
Figure 9
6.3 Preparation
Below tools are needed before installation.
Figure 10
Installation Tools
6.4 Mounting the bracket
Inverter requires adequate cooling space. Allow at least 20cm space above and below the inverter.
Figure 11
The Solar Family Series Inverter
17
Using the mounting frame as a template, drill 3 holes as illustrated in image
Figure 12
Figure 13
20CM
20CM
20CM
20CM
The Solar Family Series Inverter
18
6.5 Mounting the Inverter
Hang the inverter onto the mounting frame.
Figure 14
Insert safety- lock screws into the bottom leg to fasten the inverter.
The Solar Family Series Inverter
19
Figure 15
6.6 Check Inverter Installation Status
Check the upper straps of Inverter to ensure it is fixed on to the bracket
Check the secure mounting of the PV-Inverter by trying to raise it from the bottom.
The PV-Inverter should remain firmly attached.
Select the installation location so that the status of display can be easily viewed.
Choose a strong mounting wall to prevent vibrations while inverter is operating.
6.7 Connector Guide
This product has a professional IP68 DC waterproof connector. You have to wire DC by yourself.
Please see
Figure 16
and
Figure 17
for DC connector disassembling guide.
Connectors must only be connected by qualified personnel
Only PV1-F cables can be used. The TÜV approval only allows the use of PV1-F cables. Do not
use type H07RN-F cables.
The connectors must be not disconnected while under load. For protection against electric shock,
connectors must always be disconnected from the power supply during assembly.
Connectors that are not plugged must be protected against humidity and contamination by a
protective cap. Any kind of contamination may have adverse effect on the system and great care
must be taken during assembly to ensure that everything is clean.
The Solar Family Series Inverter
20
Connectors provide IP68 protection but should not be continually exposed to water (e.g. immersed
under water) and not placed directly on the top side.
Connecting to PV panel (DC input):
Figure 16
1. Wire stripping 7mm
2. Insert the wire into the core with pliers pressure;
3. The core penetration into the terminal internal until clamping, then tighten the nut
The Solar Family Series Inverter
21
Figure 17
Connecting to the grid:
1.
Measure grid voltage and frequency to see whether they are normal.
2.Open the breaker or fuse between inverter and utility grid.
3.Connect AC wires of inverter as follows:
The Solar Family Series Inverter
22
L N
1
2/3
4
5
6
Figure 18
Below is the AC cable specification table when select the cable for installation.
Table 7
Cable and Micro-breaker Requirement
Model
SF1.6KTN
SF2.2KTN
SF3KTN
SF3.6KTN
SF4.2KTN
SF4.6KTN
SF5KTN
Cable (Cu)
2.5mm
2
2.5mm
2
2.5mm
2
4mm
2
4mm
2
4mm
2
4mm
2
Micro-Breaker
16A
20A
20A
25A
25A
25A
32A
The Solar Family Series Inverter
23
7 Operation
7.1 LED Display
The panel has three LED indicators as follows:
Figure 19
7.1.1 DC/DC status LED (Green)
Table 8
Off
The DC/DC Circuit is off.
Blinking
The DC/DC Circuit is starting.
On
The DC/DC Circuit is working
normally
7.1.2 DC/AC status LED (Green)
Table 9
Off
The DC/AC Circuit is off.
Blinking
The DC/AC Circuit is starting.
On
The DC/AC Circuit is working
normally.
7.1.3 Fault LED (Red)
Table 10
Off
No Error occurs
On
The inverter is in fault status
Normally, after starting up, DC/DC LED and DC/AC LED will be lighted indicating that the Inverter's
feeding power status to the grid.
NOTE:Wire color requirements L-Red/N-Black/Gnd-Yellow&Green
The Solar Family Series Inverter
24
7.2 LCD Display
The LCD display monitors the inverter status and collects statistical data for assessing system
performance.
The display on the inverter can be controlled by key
To save power, the LCD display’s backlight will turn off automatically after 30 seconds.
A summary diagram of the display functions is shown as the figure below,
Figure 20 LCD summary diagram of SF1.6KTN, SF2.2KTN, SF3KTN
Figure 21 LCD summary diagram of SF3.6KTN, SF4.2KTN, SF4.6KTN, SF5KTN
7.2.1State Page
State:
Waiting...
Figure 22
Fault Information is listed as the following table
Table 11
Display
Description
Leakage Fault
The internal hardware that measures ground fault has measured
substantially high ground currents.
Grid Fault
Grid Voltage or Frequency out of range
Boost Fault
Boost(DC/DC) Power Stage fault
PV Over Voltage
PV panel Voltage too high
Relay Fault
The AC relay failed
DCINJ High
Output Current DC Offset too high
RCD Fault
The RCD measurement mechanism has failed during the wake-up
Setting
State
Power
E-day
Energy
-total
Output
Info
Input
Setting
State
Power
E-day
Energy
-total
Output
Info
Input
The Solar Family Series Inverter
25
test phase.
Ov Temp
Over temperature
DC Bus High
DC Bus Voltage Fault
Grid Lock Failed
Grid Phase Lock failed
CPU Commu Failed
CPU Communication Fault
Aux Power Fault
+12V Power fault
ISO Fault
Isolation Fault
Inv Fault
Inverter(DC/AC) Power Stage fault
Boost Ov Curr
Boost (DC/DC) Power Stage over current
INVOvCurr
Inverter(DC/AC) Power Stage over current
PVPowerLow
PV Power too low
7.2.3Power&E-day Page
The inverter power&Energy-day will be displayed in this page.
Power: 0 W
E-day:0.00Kwh
Figure 23
7.2.4 Energy-Total Page
The inverter Energy-total will be displayed in this page.
Energy-Total:
0.0Kwh
Figure 24
7.2.5 Input Page
The inverter PV parameter will be displayed in this page.
INPUT:
PV1:360V 0.0A
Figure 25
7.2.6 Output Page
The inverter AC parameter will be displayed in this page.
OUTPUT:
220V 0.0A 0.00Hz
Figure 26
7.2.7 Setting Page
Setting
Com-Addr
:
01
Figure 27
7.2.8 Information Page
SN:SF3K016010001
VER: V100 V208
Figure 28
The Solar Family Series Inverter
26
7.2.9 Setting option
Date:16-01-01
Time:08:00:00
Work Mode
:
Mppt
Max Volt
:
270V
Max Freq
:
50.0Hz
P-Limit
:
100%
Country
:
CHN
GFCI: Disable
RISO: Disable
State:
Waiting...
Power: 0 W
E-day:0.00Kwh
Energy-Total:
0.0Kwh
OUTPUT:
220V 0.0A 0.00Hz
SN:SF3K016010001
VER: V100 V207
Setting
Com-Addr
:
01
INPUT:
PV1:360V 0.0A
Setting
Com-Addr
:
01
Fault
:
01
01
:
GridFault
ENTER
Scan
ESC Cancel/OUT
UP
DONW
OK/ENTER
Figure 29
The Solar Family Series Inverter
27
8 Setting up Communication
8.1 Communication Interface Type
This product has a communication interface
RS485 and
Serial Port
(optional).
Operating
information
such as o
utput voltage, current, frequency, fault information, etc., can be delivered to
PC or other monitoring equipment vi
a RS485.
8.2 Communication
When user want to know the information of the power station and manage the entire power system.
We offer below three types of communications.
Figure 30
Communication Interface of SF
Series
Inverter
Table 12
3-line RS485
Wire No.
Function
Serial Port Wire No.
Function
1
A
1
VCC
2
B
2
RXD
3
NC
3
TXD
4
GND
8.2.1
Connect the system by Serial Port/RS485 Adapter
User can use a Serial Port/RS485 to USB Adapter to connect the inverter and the PC, Please note
that the inverter’s serial port is TTL standard not RS232 standard. Using B&B Data Explorer , the
inverter’s information can be checked on PC.
Take example of RS485 (
Figure
35):
Serial Port
RS485
RS485
1
2
3
4
3
1
2
3
2
1
The Solar Family Series Inverter
28
Figure
31
8.2.2
Webbox Communication (optional)
The connection way between SF Series Inverters are a straight through cable. But the connection
between SF Series Inverters and Webbox uses a crossover cable. As shown in the following
figure.
USB
Grid-tied Inverter
RS485
Grid-tied Inverter
RS485
RS485
adapter
PC
The Solar Family Series Inverter
29
Figure 32
Web Box Monitoring Diagram
8.2.3
Embeded WiFi Communication (optional)
Embeded WiFi module is a hardware device can be inserted to inverter’s serial port. Please refer
to WiFi module Manual for more information.
Table 13
1
2
4
3
1
2
3
4
Inverter serial Port
Connector
WiFi Module
Connector
Figure 33
8.2.4
Inverter demand response modes(DRMS)
(optional)
The demand response controls(DRC)
module is a hardware device can be inserted to inverter’s
serial port.
As shown in the following figure 34.
1
2
3
1
2
3
Inverter RS485
connector
DRED RS485
connector
Figure 34
The RJ45 socket pin assignments for demand response modes are
in Table 14.
Pin
Assignment for inverters capable of both charging and discharging
1
Resverve
2
Resverve
3
Resverve
4
Resverve
5
RefGen
6
Com/DRM0
7
V+
8
V-
Table 14
The Solar Family Series Inverter
30
9 Troubleshooting
In most situations,
the inverter requires very little maintenance.
However, if Inve
rter fails to
work
perfectly, please refer to the following instructions before calling your local dealer.
Should any problem arises, the LED on the front panel will be red and the L
CD will display t
he
relevant information. Please refer to the following table for a list of potential problems and
solutions.
Table 15
Troubleshooting list
Faults
Diagnosis and Solutions
Grid Fault
-Waiting for one minute, grid will go back
to normal working state.
-Making sure that grid voltage and
frequency complies with standards.
-Or, please seek for help from us
-Off to grid.
-Please check grid-connection, like wire,
interface, etc.
-Checking grid usability.
-Or seek for help from us.
PV Over Voltage
-Checking the panel’s open-circuit voltage
whether the value is close to or
already >Max.DC voltage.
-Please seek help from us when voltage
≤
Max.DC voltage.
DCINJ High
-Disconnect the PV (+), PV (-) with DC
input, then reconnect them.
-Check L line and N line to see whether it
has connection faults.
-Please seek for help from us when this
fault happens.
Relay Fault
-Disconnect the PV (+), PV (-) with DC
input, then reconnect them.
-Please seek for help from us if it can’t go
back to normal state.
*
Self Testing Fault
(
SF3.6KTN,SF4.2KTN,SF4.6KTN,SF5KTN
)
-Please check whether working in IN1 &
IN2 P mode.
-
Check PV1,PV2 if there is no connection
- Or please seek for help from us.
●
Check the warning or fault messages on the information panel. Record the message if displayed
for further action.
●
Try the solution indicated in
Table 15
.
●
If your inverter information panel didn’t have a Fault light, check the following list to make sure
The Solar Family Series Inverter
31
that the present state of the installation allows proper operation of the unit.
— Is the inverter located in a clean, dry, ventilated place?
— Have the DC input breakers been opened?
— Is the size & length of cables suitable?
— Are the input and output connections and wiring in good condition?
— Are the configurations settings correct for your particular installation?
—Are the display panel and the communications cable properly connected without damage?
The Solar Family Series Inverter
32
10 Decommissioning
10.1 Dismantling
●
Disconnect the inverter from DC input and AC output.
●
Remove all connection cables from the inverter.
●
Remove the inverter from the bracket.
10.2 Packaging
If possible, it’s better to pack the inverter with the original packing.
If original packing is not available, please use similar packing which meets below requirements
●
Load ability should be over 20kg.
●
With handle.
●
Able to fully closed.
10.3 Storage
Store the inverter in a dry place where ambient temperature is always between -25
℃
and +60
℃
.
-13°F to +140°F.
10.4 Disposal
Please put the defective inverters & packing materials to a place which is convenient for relevant
department to dispose and recycle.
The Solar Family Series Inverter
33
11 Warranty
Warranty certificate represents a 6 year warranty service for mentioned products since the date of
purchase.
Warranted Products
This warranty is applicable solely to the following products:
SF1.6KTN SF2.2KTN SF3KTN
SF3.6KTN SF4.2KTN SF4.6KTN SF5KTN
Limited Product Warranty
(Applicable under normal application, installation, use and service conditions.)
SF Series Inverter warrants the above listed products to be free from defects and/or failure
specified for a period not exceeding 6 years from the date of sale as shown in the roof of Purchase
to the original purchaser.