INSTRUCTIONS FOR INSTALLATION AND MANUAL 
Solid fuel cooker for central heating THERMO MAGNUM PLUS 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

To respected customer, 

 
 
We are very pleased for your trust and your decision to buy our product. 
 
You made a good choice, because Thermo Magnum has technical characteristics 
which classify it into the very top of its class, providing advantage within its 
competition. 
 
Please, read carefully this instructions before you use Thermo Magnum, in order to 
find hints and tips for proper handling and maintenance. 
We also believe that you will put your signature in the book of satisfied customers of 
our products. 
 
                                                            
                                                                "Milan Blago

jević" AD 

                                                                        Smederevo 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 
 
 
CONTENTS 
 

 
Warning before use ................................................................1 
Cooker description...................................................................2 
Installation................................................................................4 
Installation of the stove into the water heating system ............6 
Managing operation…..............................................................10 
Ignition and lighting... ...................…….................……………..11 
Cleaning and maintenance.......................................................12 
General notes ..........................................................................13 
Advices for environmental protection .......................................13 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 
 
 
WARNING BEFORE USE 

 
In order to put cooker Thermo Magnum in proper operation mode, it is important to 
read this instructions and strictly observe instructions for use and manual. 
 
For combustion, use solid fuels like wood and briquettes. For maximal performance 
of the cooker, use dry wood (max. humidity 20%). 
 
It is forbidden to put explosive devices and materials into the burner or onto the 
cooker hotplate. 
 
It is forbidden to keep inflammable materials within the close vicinity of the cooker. 
 
For proper combustion, within the normal operational mode, draught in the chimney 
should be 15-17 Pa. In case if draught is higher then 20Pa, it is necessary to install 
chimney flap. 
 
Room in which cooker is located should be regularly ventilated due to flow of fresh 
air necessary for combustion. 
 
 
Parts of the cooker are heated within period of operation and appropriate handling 
precaution is necessary. Do not allow children to handle and play in the vicinity of the 
cooker. 
 
Do not allow handling with the cooker to the persons with limited physical and 
psychical abilities. 
 
Do not allow pets to be close to the device. 
 
Only spare parts approved by the manufacturer may be installed onto the cooker. 
One may not make any changes to the furnace. 
 
Upon the first heating, smoke and various scents may occur, especially on the 
surfaces protected with the color and other anti-corrosive primers. Ventilate the 
room. 
 
Thermal regulator is integral part of the cooker and set-up at the factory. Do not 
make any adjustments of thermal regulator by yourself.  
 
When adding fuel, open fire door for only few degrees, wait 4-5 seconds until 
pressure in the burner and room comes equal, then open it wide very slowly. Do not 
open the door abruptly, so when flame is strong in the burner it may come out of the 
burner. Do not open fire door unnecessarily, always paying attention to open it when 
flame is weak. 
 

 


background image

In case of non-observance of these instructions for use, manufacturer will not 
be liable for any damage on cooker. 

 
 
 
 

COOKER DESCRIPTION 

 
 

 

 
 
 
Figure 1. Integral parts of the Thermo Magnum cooker 
 
1 – hotplate 
2 – secondary air regulation 
3 – fire door 
4 – grate  
5 – ashtray door 
6 – ashtray 
7 – fume outlet 
8 – oven door 
9 - thermometer 
10 - drawer 
11 – thermo-regulator button 
   
 
Solid fuel cooker for central heating Thermo Magnum is made and tested according 
to the European standard EN 12815. Figure 1 shows appearance of cooker with 
integral parts important for handling and use. Table 1 gives its technical 
characteristics. 
 
 

 


background image

Table1.  Technical characteristics 
 

1.  Nominal thermal power (kW) – wood/coal __________14/17 
2.  Efficiency (%) – wood/coal______________________89/85 
3.  Thermal power transferred to water (kW) ____________9/9  
4.  Thermal power transferred to environment (kW) _______5/7 
5.  The average CO value ( taken from 13% O

2

): 

      wood________________________________0,070% 

 

0,875 g/m³ 

            brown coal___________________________0,081% 

 

1,013 g/m³ 

     6.    Dust emmision: 
           wood______________________________________0,055 g/m³ 
           brown coal__________________________________0,070 g/m³ 

7  Dimensions – W x H x L (mm) _______________________1070x850x600 
8  Dimensions of firebox W x H x L (mm) _________________230x280x370 
9  Dimensions of oven – W x H x L (mm) _________________350x265x465 
10  Quantity of water in boiler (l) _________________________11 
11  Diameter of fume outlet (mm) ________________________130/150 
12  Water adapters (”)_________________________________1 
13  Draught (Pa) _____________________________________15 -17 
14  Average flue gases temperature (°C) __________________224 
15  Maximal water temperature (°C) ______________________90 
16  Recommended fuel _________________________wood, wood briquettes 
17  Consumption at nominal power(kg/h) __________________4.5 
18  Max. working pressure (bar) _________________________2 

 
 
  Solid fuel cooker for central heating is intended for heating of residential premises. 
Valve for thermal exhaustion is integral part of installation which serves as 
overheating valve. Thermal valve 

Caleffi 544 1/2

 is recommended and displayed on 

Figure 2. 
 

Comment:

  Thermal valve is not part of the product and not supplied with it. Boiler 

guarantee is valid exclusively with built-in thermal valve. 
 
 

 

Figure 2 
 
 

 


background image

 
Solid fuel cooker for central heating Thermo Magnum possesses boiler of 11l 
capacity which is made of boiler metal sheets of standardized dimensions. Such 
manufacture improves boiler life span. Water adapters are 1“. 
Fire door (fig. 1, pos. 2) is cast and has thermal-resistant transparent glass. Ashtray 
door (fig., 1, pos. 5) is cast and has auxiliary air flow regulator.  
  Oven door is cast and has thermal-resistant glass with temperature gauge. Area 
below oven is intended for mechanism which serves for primary manual regulation 
and it is not intended for opening (handle is decorative element, it does not serve for 
door opening below the oven) 
 

INSTALLATION OF COOKER 

 
Cooker 

may not

 be placed in the close vicinity of wooden elements, air-condition 

devices or plastic parts of the furniture, because it transmits (during combustion) 
high working temperature which distributes at the external surface of the cooker. 
Minimal distance between cooker and surrounding elements is 50 cm, and from 
inflammable materials is 140 cm. 
 
    If foundation on which cooker will be located is made of easily-inflammable 
materials (wood, warm floor, laminate...) it is necessary to install special protection 
larger then the base of the cooker.  -  for lateral width of 10 cm or more, in front of 50 
cm or more. 
 
Cooker is to be connected with the chimney by appropriate smoke pipes through 
adapter on the upper side of the cast plate, in order to provide adequate tightness 
and smoke flow from the cooker to the chimney. Fume outlet may not be installed 
too deep into the chimney in order not to reduce surface of cross-section thus 
preventing draught in the chimney. 
   
  Prior to installation of cooker, check chimney draught since it is one of key factors 
for proper operation.  Draught depends on integrity of the chimney and 
meteorological conditions. 
   
One of the simplest ways for checking of draught in chimney is by candle flame, as 
described on figure 3. Candle flame is to be put close to adaptor opening of chimney 
and if it flickers toward opening, draught is satisfactory (figure 3.2). Weak flickering of 
the flame is indicator of weak draught (figure 3.1). 
 

 

                Fig 3.1                                                     Fig 3.2 

 


background image

 
If draught in chimney is weak (Figure 3.1), check correctness of the chimney. 
Chimney should be located in the interior of the room, and id it is on external walls of 
the room, chimney insulation is highly recommended. 
 
 
Faults of the chimney may be (figure 4.1): 
     1.  Weak windshield, 
     2.  Strange body or bulges in the chimney, 
     3.  Chimney chaps, 
     4.  Accumulated tar, 
     5.  Non-tightness of adapters and cleaning openings, 
     6.  Smoke pipe installed too deep, 
     7.  Fireplace without door or some other opening on chimney and non-tightness 
of connecting and other cleaning openings. 
     8. Non-tightness of connecting and cleaning openings. 
 
  Distance between two adapters on the same chimney must be minimum 50 cm 
(Figure 4.2). 
On figure 4.2 example of proper chimney is described. 

 
Devices which use gas as a fuel may not be connected to the very same 
chimney. 
 

 

 

 
 
 

Installation of cooker into the system for water heating 

 
- For water inlet and outlet within the system of floor (central) heating are provided 
with adapters on boiler 1".  
- Thermo Magnum may be mounted on closed or open system of central heating. 

 
 
 
 
 
 

 


background image

Installation on closed central heating system 

 
One of the aspects of mounting installations is depicted on figure 5. 
 
- Safety valve must be installed in the vicinity of boiler and must be adjusted for 
pressure of max. 3 bars. External guide of safety valve must be as shorter as 
possible and may not have possibility to be closed. Within this guide, also, there may 
not be single valve or any other armature. 
- Closed expansion vessel is to be mounted in the vicinity of boiler and its safety 
guide is short. Volume of this vessel is determined according to the capacity of boiler 
and regarding ratio 1kW:1l. 
- Installation of thermal valve in its provided place on the boiler is mandatory. We 
recommend thermal valve Caleffi 544. 
 
 

 

                                               Figure 5 
           Scheme of closed central heating system 

 


background image

Pump 
Valve 
Thermo-manometer 
Air-exhaust valve 
Safety valve 
1 Intake valve 
2 Guide for gilling and discharging the system 
3 Distribution guide 
4 Thermal exhaust valve 
5 Drainage for overheated water from the system 
6 Aqueduct network 
7 Closed expansion vessel 
 
 

Installation of open central heating system 

  
One of the aspects of installation is depicted on figure 6. 
At this system, starting guides are to be mounted in sequence, safety distribution 
guide of expansion vessel and boiler valve, and on starting guide of the system 
boiler valve, pump and valve are to be installed. Directly below opened expansion 
vessel, short connection should be installed between safety distribution guide and 
safety retracting guide, which provides freezing of water during winter in the 
expansion vessel. 
On safety distribution and safety retracted guide, there may not be any armature. 
Expansion vessel itself must possess overflow pipe as seen on scheme on figure 6. 
Volume of expansion vessel is determined by the pattern:  
        V = 0,07x V water, (l), where Vwater is volume of water in entire power plant. 
 
Open expansion vessel is to be installed vertically above the highest heating body. 
At the opened system of heating, gravitation system of heating is possible. 
 

Note:

  

 
Installing and putting into operation of entire system is to be checked exclusively by 
trained person who guarantee proper operation of entire heating system. In case of 
poorly designed system and eventual omissions in installation by that person, 
complete material responsibility shall bear exclusively the person entrusted for the 
installation of the heating system, not the manufacturer, representative or retailer of 
the boiler. 
 

Important 

• Cooker installation should be carried out by skilled person according to the 
appropriate design. Structure of cooker enables connection on closed or opened 
heating system. All connections must be well sealed and tightened. Prior to putting 
into operation, complete installation should be tested with water under pressure of 3 
bar. 
 
• Upon installation of safety valve, pay attention to direct connection with water 
supply network and sewage, as well as on the fact that valves (taps) always must be 
open. 

 


background image

 
• If reinforced hose for connection with drainage outlet is used, it must be away from 
the back side of the cooker. 
 

Upon first ignition,

 it is necessary to test accuracy of the valves by short-time pre-

heating up to 100°C, to test accuracy of draught regulators and installation for 
distribution of hot water to radiators, as well as radiators themselves. 
 
 
 
 

 

                                Figure 6 
           Scheme of open central heating system 

 


background image

 
Safety valve 
Pump 
valve 
Air exhaust valve 
Automatic air exhaust valve 
 
1 Connection guide 
2 Overflow duct with valve 
3 Filling and discharging system 
H  Altitude difference on behalf of boiler towards network 
 

MANAGING COOKER OPERATION 

 
  Pace of combustion, as well as quantity of heat transmitted by the cooker, depends 
on the quantity of primary air for combustion which is brought into the area below 
burner. Regulation of quantity of primary air is provided automatically using draught 
regulator 

Rathgeber

 (figure 7). 

 

 

Figure 7 
 
  Upon ignition, turn regulator button into position of maximally opened flap in 
direction displayed on figure 8. During operation, depending on temperature, 
regulator flap will open and close automatically. If lower temperature then adjusted is 
desired, turn regulator button in desired position of minimally open flap, thus 
regulator flap closes. Button is to be turned with auxiliary tool as follows: longer arm 
of the tool is to be put into the groove of the button then turn, as desired. 
 

 


background image

 

 
Figure 8 
 
By grate lifter (pic. 1, pos. 4) and turning using tool which is supplied with the cooker, 
plate may be lifted and dropped down in desired position depending on selected 
operation mode (winter or summer mode). 
  If there are disturbances in burning (bad fuel, remaining malfunctions for proper 
operation of the cooker) then through auxiliary regulator, which is located on front 
side of the ashtray door (figure 1 position 5), we can bring some additional primary 
air, thus improving combustion. In that case, pay attention to temperature and 
pressure not to exceed prescribed values. 
 
 
 

PROCEDURES FOR IGNITION AND LIGHTING 
 

  Prior to the first ignition, clean all enameled surfaces of the cooker by dry mop in 
order to avoid combustion of dirt on cooker and creation of undesirable scents. 
   
  

Note:  

  Upon first ignition, there may be slight smoking, especially at colored surfaces. All 
cast parts are protected with thermo-resistant color which obtains its stability after 
few ignitions. Thereupon, there may be gases which could be removed by simple 
ventilation of the room. 
 
  Ignition in the firebox is to be carried out as follows: 
  -  open the fire door and ashtray door, 
  -  put into the firebox material for enkindle (chopped wood, dry paper), 
  -  carry out enkindling, 
  -  close the fire door and ashtray door, 
  -  upon creation of basic cinder, put into the firebox some massive pieces of wood 
and close fire door. If briquettes are used, you must wait for all fuel quantity to burn, 
then reduce air intake to half. 
 
  For ignition and lighting, you may not use light distillate oil, gas and similar, so then 
conditions for origination of explosive gases may occur in smoke channels of the 
cooker and chimney. 
 
  For lighting, we recommend wood and briquettes. 
 

 


background image

  Do not use organic waste as fuel, food residues, plastic objects, inflammable and 
explosive materials, whose combustion disturbs proper operation of the cooker and 
may induce damages and pollution of environment. 
 
  Increased external temperatures may induce weak air flow (draught) in the 
chimney, so it is recommended to frequently burn smaller quantities. We recommend 
burning every 1h with height of the fuel in the firebox up to 15cm. 
 
  After each filling, it is recommended for firebox (cooker) to burn at least 30 minutes 
with maximal power, in order to burn all volatile ingredients which are main reason of 
creation of condensate in the cooker in that stage of combustion. 
 
  For proper work of firebox (cooker) it is necessary to: 
  -  regularly clean firebox and chimney 
  -  regularly ventilate rooms due to good combustion 
  -  regularly remove ash from ashtray 
 
 
  

Accumulated gravel and non-combusted materials should be regularly 

removed from the burner, by cleaning set.

 

 
 
 

CLEANING AND MAINTENANCE 

 
  Through regular and proper cleaning, you enable proper operation and cooker life 
span. 
 

Cleaning of external surfaces 

  Enameled and chrome surfaces are to be cleaned with soft mop which will not 
damage these surfaces. Cleaning agents of chemical origin do not damage surfaces 
of the cooker and may be used. 
 

Cleaning of internal surfaces 

  Upon cleaning of the cooker, use protective gloves. Clean internal walls of the 
burner and remove accumulated tar, collect particles and non-combusted pieces 
from the burner, clean ashtray and ash accumulated in the interior.  
 

Glass cleaning     

  Upon combustion of fuel, glass surface may become dirty due to products of 
combustion. Glass should be cleaned when it is cold, by soft detergents. Abrasive 
agents damage glass thus do not us them. 
 
 

Cleaning channels for flow of gas combustion products below oven 

 
Open oven door (1), unscrew 6 screws (4) on the bottom of oven (3) and remove 
closure of the bottom (2). By auxiliary tool, remove tar accumulated on the bottom 
and below oven. After cleaning, put back the closure of the oven bottom into its 
original position and put and tight screws back. 

 


background image

 

Area below plate must also be maintained clean. Remove plate from the cooker and 
clean tar from boiler and ceiling of the oven. 
 

GENERAL NOTES 

 
  If all instructions for installation, regulation during operation and cleaning directions 
given in this manual are fulfilled, cooker represents approved and safe device for 
using in the household. 
  All reclamations, evaluated as defects or weak functioning of the cooker, should 
report to manufacturer or authorized service by phone or in written with fiscal receipt. 
All contact information is given at the end of this manual. 
  Each defect of cooker should be removed exclusively by manufacturer or 
authorized service. 
  If unauthorized persons make any servicing or any other repairs and changes on 
the cooker, owner of cooker loses his right for guarantee by the manufacturer. 
  Procurement of spare parts is to be done exclusively through manufacturer’s 
service, based on positions and figures in this manual or designation of mentioned. 
  Manufacturer does not bear any liability if customer does not observe instructions 
for use and installation of the cooker. 

 
ADVICES FOR ENVIRONMENTAL PROTECTION  

 

Packing 

  -  Packing material may be 100 % recycled. 
  -  Upon disposal, observe local regulations. 
  -  Packing material (plastic bags, parts made of polystyrene-styropor etc.) should be 
kept away from children, since it may represent potential harm. 
  -  Wooden battens which are the case of transport packaging are connected with 
nails!  
     Pay attention on injuries during disassemble and disposal of wooden packaging. 
 

Product 

  -  Device is made of materials which may be recycled. Upon disposal,  
     observe local environmental laws. 

 


background image

  -  Use only recommended fuels. 
  -  Combustion of non-organic and organic waste (plastic, chip,  
     textile, oiled wood etc.) is strictly forbidden, since when combusted, they release 
cancerogenous and other harmful materials. 
 
 
A

.D. “Milan Blagojević” Smederevo 

Đure Strugara 20 
11300 Smederevo 
tel: +381 26 633 600 
       +381 26 633 601 
fax: 026 226 926  
e-mail: 

office@mbs.rs

 , 

servis@mbs.rs

  

 Web:  

www.mbs.rs