3  Emptying a Platinum Series Central Vacuum Power Unit

Bagged Platinum Series

The debris bucket is the removable lower section of 
the power unit. The Platinum Series central vacuums 
contain a Model VMP600 slide-gate collar dust bag that 
is installed inside the debris bucket. The debris level in 
the dust bag is indicated by the front panel display of the 
vacuum. The dust bag should be replaced when the red 
bars of the bag level indicator light (bag full). Regular dust 
bag replacement will enhance performance and conform 
to the terms of the product warranty. The dust bag inside 
the debris bucket should be replaced fi ve to six times a 
year under normal use.
The Platinum Series vacuums contain a self-cleaning 
inverted cloth fi lter. When the power unit is running, 
the cloth fi lter is pulled upward inside the vacuum body. 
When the power unit is turned off, the weighted center of 
the fi lter causes it to drop, depositing dirt and dust past 
the dust cone and into the debris bucket. It is normal to 
see some accumulation of dirt on the fi lter. 

The inverted 

cloth fi lter should not be removed for any reason 
except to replace it if it becomes damaged or torn.

To replace the dust bag, follow these easy steps:

Make sure the power unit is disconnected from the 
electrical wall outlet.

Swing the two bucket slide latches down to lower the 
debris bucket.

Remove the debris bucket from the slide latch hangers.

Remove the dust bag from the debris bucket and pull 
on the bag’s slide-gate to seal the bag.

Dispose of the dust bag in a refuse container.

Use your hand to expand the bag of a new VMP600 
dust bag and place it into the debris bucket.

Reach into the dust bag again and expand the bag 
against the sides of the debris bucket.

Reattach the debris bucket on to the slide latch hangers.

Swing the two bucket slide latches up to raise and 
seat the debris bucket.

10 

Reconnect the power unit to the electrical wall outlet.

11 

Press the RESET button for seven seconds to reset 
the bag indicator.

4  Emptying a Red Series Central Vacuum Power Unit

Bagless Red Series

The debris bucket is the removable lower section of 
the power unit. The debris bucket is semi-transparent, 
the dirt level can be seen through its sides. The debris 
bucket in the Red Series central vacuum must be 
checked periodically and emptied when it becomes 3/4 
full. Regular emptying will enhance performance and 
conform to the terms of the product warranty. Dirt and 
debris are deposited in the debris bucket and it should be 
emptied fi ve to six times a year under normal use.

The Red Series bagless vacuums contain a self-cleaning 
inverted cloth fi lter. When the power unit is running, the 
cloth fi lter is pulled upward inside the vacuum body. 
When the power unit is turned off, the weighted center 
of the fi lter causes it to drop, depositing dirt and dust into 
the debris bucket. It is normal to see some accumulation 
of dirt on the fi lter. 

The inverted cloth fi lter should not 

be removed for any reason except to replace it if it 
becomes damaged or torn.

To empty the debris bucket, follow these easy steps:

Make sure the power unit is disconnected from the 
electrical wall outlet.

Swing the two bucket slide latches down to lower the 
debris bucket.

Remove the debris bucket from the slide latch hangers 
and empty the bucket into a refuse container.

Reattach the debris bucket on to the slide latch hangers.

Swing the two bucket slide latches up to raise and 
seat the debris bucket.

Reconnect the power unit to the electrical wall outlet.

5 Troubleshooting

IF THE MOTOR FAILS TO OPERATE

Be sure the power unit is plugged into a working AC outlet.

Push circuit breaker reset button on the power unit.

Check the panel circuit breaker that connects the power unit. If the breaker has tripped, reset it. If the breaker 
trips again, call your AirVac dealer for service.

AFTER CHANGING OF THE BAG (PLATINUM SERIES ONLY)

Push down the RESET button for seven seconds to reset the bag indicator.

IN CASE OF LOW VACUUM POWER

Be sure that the inlet plug is inserted into the unused power unit intake port.

Check that all wall valves are closed.

Check that all gaskets on wall valves are sealed.

Check to see if debris bucket or bag (Platinum Series only) needs emptying.

Check for obstructions in the hose, tools, or vacuum lines.

Check for any ruptures or breaks in the vacuum duct system.

If you encounter any problems with your equipment, verify the operation against the information contained in these 
instructions. If, after checking your system you are unable to determine the cause of the problem, contact your local 
AirVac dealer for assistance or call our Technical Services department at (800) 421-1587. Be sure to have the exact 
model number, serial number, and the nature of the problem ready. If possible, 

CALL FROM THE SITE.

 We cannot 

effectively troubleshoot your system if you are not calling from the location where the equipment is installed or used.

6 Limited Warranty

CENTRAL VACUUM MODELS

AVP3000, AVP7500, AVP12000, AVP24000
AVR3000, AVR7500, AVR12000, AVR24000

HOMEOWNER’S INSTRUCTIONS

For Platinum and Red Series AirVac Units

(for Household Use Only)

IMPORTANT SAFETY NOTES

Please read the instructions carefully! Through many years of continuous use -- and through quality tests that are 
ongoing at our factory -- AirVac central vacuums, attachments and accessories have built a remarkable record 
for cleaning effectiveness and safety.  However, there are potential hazards that could occur if the system is not 
installed and operated correctly and safely. 

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.

THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES IN THESE INSTRUCTIONS.

1  Central Vacuum Accessories

Many accessory packages and tool kits are available for AirVac central vacuums. Refer to the packages below and 
contact your local AirVac central vacuum dealer for these and additional central vacuum components.

2  Platinum Series Service Indicators

Bag Indicator

The Platinum Series central vacuums have an indicator on the control panel to display the approximate debris level 
of the vacuum’s replaceable dust bag. The green, yellow, orange, and red indicators will light, showing the bag 
debris level. The bag indicator displays the dust bag level whether the vacuum power is on or off.

NOTE: 

The debris level indicator light is meant to provide an approximation of the actual level in the dust bag. In a 

heavy use environment, (i.e. pet hair or new carpet fuzz) the bag may fi ll before the indicator reads full.

Service Indicator

The Platinum Series central vacuums have an indicator on the control panel to display the status of the vacuum’s 
motor and when the motor will require service. The service indicator displays the motor status whether the vacuum 
power is on or off.

PLATINUM SERIES SERVICE INDICATOR

INDICATOR COLOR

MOTOR CONDITION

GREEN

NORMAL, NO ACTION 
REQUIRED

FLASHING GREEN

MOTOR SERVICE WILL 
BE REQUIRED SOON

FLASHING RED

HAVE MOTOR SERVICED NOW

RED

HAVE MOTOR SERVICED 
IMMEDIATELY

IMPORTANT SAFETY INSTRUCTIONS

  WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY:

PRINTER’S INSTRUCTIONS:

INSTR,H.O. GUIDE,AIRVAC; LINEAR P/N: 227004 B; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1

  CAUTION 

This type of warning note is used to indicate 
the possibility of damage to the vacuum power 
unit or vacuum duct system.

 WARNING 

This type of warning note is used to indicate 
possible fi re or electrical shock hazards that 
may cause serious injuries or death.

R

EMOVE DE

BR

I

S

B

UCKET F

R

OM

B

UCKET 

S

LIDE

LATCHE

S

S

WIN

G

 THE TWO

B

UCKET 

S

LIDE

LATCHE

S

 DOWN

REMOVING THE DEBRIS BUCKET

  CAUTION 

NO USER SERVICEABLE PARTS INSIDE.

DO NOT LUBRICATE THE MOTOR.

 1 READ

 this manual before assembling or using 

your vacuum cleaner.

 2 USE

 your vacuum only as directed in this manual. 

Use only recommended attachments.

 3 KEEP

 hair, loose clothing, fi ngers and all parts of 

the body away from openings and moving parts.

 4 DISCONNECT

 electric power head before 

servicing or cleaning the brush area. Failure to do 
so could result in electric shock or sudden start-
up of the brush.

 5 ALWAYS

 turn electric power head off before 

connecting or disconnecting the hose or power 
nozzle.

 6 USE

 extra care when cleaning on stairs.

 7 DO NOT

 use outdoors, on wet surfaces, or to 

pickup liquids of any kind. Electric shock could 
occur.

 8 DO NOT

 unplug by pulling on the cord. To unplug, 

pull the plug, not the cord.

 9 DO NOT

 operate the system if the power cord, 

hose, or power nozzle is damaged or the 
equipment has been left outdoors. Send the unit 
to a qualifi ed service repair center.

 10  DO  NOT

 pull or carry the unit by the cord, or pull 

around sharp edges or corners. Do not run the 
power nozzle over the cord. Keep the cord away 
from heated surfaces.

 11  DO  NOT

 allow the system to be used as a toy. 

Close attention is necessary when used near 
children.

 12  DO  NOT

 handle the plug or electric power head 

with wet hands.

 13  DO  NOT

 operate the vacuum with a punctured 

hose. The hose contains electrical wires. If the 
hose is cut or worn, it should be replaced 
immediately. Avoid vacuuming sharp objects.

 14  DO  NOT

 put any objects into openings. Do not 

use with all openings blocked; keep free of dust, 
lint, hair, and anything that may reduce air fl ow.

 15  DO  NOT

 use the vacuum to pick up hard, sharp 

objects. They may damage the vacuum.

 16  DO  NOT

 use the vacuum to pick up fl ammable or 

combustible liquids (gasoline, cleaning fl uids, 
perfumes, etc.) or use in areas where they may 
be present. Fumes from these substances can 
create a fi re hazard or explosion.

 17  DO  NOT

 use without the dust bag in place 

(Platinum Series only).

 18  DO  NOT

 use system to clean ashes from a 

fi replace, as smoldering embers can burn for 
days after the fi re is out.

SAVE THESE 

INSTRUCTIONS

Copyright © 2006 Linear LLC 

227004 B

(760) 438-7000

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

Linear LLC warrants AirVac Platinum Series power units to be free of defects for 
10 years, and AirVac Red Series power units to be free of defects for 5 years. The 
warranty period begins from either (1) the date of “fi rst user” purchase of this product 
or (2) the fi rst close of escrow date on a residence in which this new product was 
originally installed. This warranty extends to the original user of the product and to 
each subsequent owner of the product during the term of this warranty. Linear LLC 
will repair or replace, at its option, parts and materials at no charge. Parts supplied 
under this warranty may be new or rebuilt at the option of Linear LLC.

If, during the limited warranty period, it appears as though this product contains a 
defect which is covered by this limited warranty, 

call our toll free service number 

before dismantling the product (1-800-421-1587). Remember to attain a Return 
Product Authorization number (RPA) before returning any product to Linear 
LLC. Send this product freight pre-paid and insured to our service center for 
warranty repair.

 You will be advised on shipping instructions when you call the toll 

free service number. Linear LLC will return the repaired product freight pre-paid 
within the U.S.A. The installing dealer or distributor may assist you, at your choice 
and expense, with returning product for repair. Please include a brief description of 
the problem and a dated proof-of-purchase receipt with any product that is returned 
for warranty repair. ANY PRODUCT RETURNED WITHOUT A RETURN PRODUCT 
AUTHORIZATION NUMBER WILL BE REFUSED.

THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS 
OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY 
OTHER OBLIGATIONS OR LIABILITY ON THE SELLER’S PART. THIS LIMITED 
WARRANTY DOES NOT COVER DAMAGE CAUSED BY ACTS OF GOD, 
IMPROPER INSTALLATION, NORMAL SYSTEM WEAR AND TEAR AS DEFINED 
BY THE MANUFACTURER, THE VIOLATION OF APPLICABLE BUILDING OR 
ELECTRICAL CODES, OR THE USE OF NON-AIRVAC WIRE, CABLE, OR 
WALL HOUSINGS. THIS LIMITED WARRANTY APPLIES ONLY TO PRODUCTS 
INSTALLED IN A PRIVATE RESIDENCE.

UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR 
CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN 
CONNECTION WITH USE, OR INABILITY TO USE THIS PRODUCT. IN NO EVENT 
SHALL SELLER’S LIABILITY, FOR BREACH OF WARRANTY, BREACH OF 
CONTRACT, NEGLIGENCE, OR STRICT LIABILITY, EXCEED THE COST OF THE 
PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR 
US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of consequential, incidental or 
special damages, so the above limitation or exclusion may not apply to you. This 
limited warranty gives you specifi c legal rights, and you may also have other rights 
which vary from state to state.

VM1200S Air-driven Turbo System Package

Non-electric system for maximum economy.

✓ 

Low-voltage crush-proof swivel hose with on/off 
switch

✓ 

Air-driven 12” turbo carpet brush

✓ 

Deluxe horsehair tools

✓ 

Telescopic vacuum accessory wand

✓ 

Hose rack and cloth caddy bag for tools

VM2200DS Standard Electric Package

Electric system with separate electric cord.

✓ 

Crush-proof swivel hose with on/off switch

✓ 

Deluxe 14” self-adjusting electric carpet brush 
with headlight

✓ 

Deluxe horsehair tools

✓ 

Telescopic vacuum accessory wand

✓ 

Hose rack and cloth caddy bag for tools

VM4200DS Deluxe SuperSystem Package

Electric system with built-in cord.

✓ 

Deluxe direct-connect crush-proof swivel hose 
with three-position switch

✓ 

Deluxe 14” self-adjusting electric carpet brush 
with headlight

✓ 

Deluxe horsehair tools

✓ 

Telescopic vacuum accessory wand

✓ 

Hose rack and cloth caddy bag for tools

VMTKD Deluxe Tool Kit

Features high-quality horsehair bristles.

✓ 

Adjustable carpet/fl oor tool

✓ 

Floor/wall tool

✓ 

Crevice tool

✓ 

Dusting brush

✓ 

Upholstery tool with brush

✓ 

Button-lock wand

✓ 

Telescopic vacuum accessory wand

VMGAR Deluxe Garage/Car Tool Kit

Features high-quality horsehair bristles.

✓ 

30-foot crushproof hose and rack

✓ 

Upholstery tool with brush

✓ 

Floor/wall tool

✓ 

Telescopic vacuum accessory wand

✓ 

Adjustable carpet/fl oor tool

✓ 

Dusting brush

✓ 

On-board tool caddy

✓ 

Crevice tool

Also visit www.purelypowerful.com for more 
AirVac Central Vacuum accessories.

R

EMOVE DU

S

T

B

A

G

 F

R

OM

B

UCKET

PULL 

S

LIDE 

G

ATE

ON 

B

A

G

 COLLA

R

TO CLO

S

E THE 

B

A

G

DI

S

PO

S

E OF 

B

A

G

IN 

R

EFU

S

E CONTAINE

R

REMOVING THE DUST BAG

EXPAND THE DU

S

T

B

A

G

 

B

EFO

R

E PLACIN

G

IT INTO THE DE

BR

I

S

 

B

UCKET

S

LIDE-

G

ATE COLLA

R

 

B

A

G

PLACE THE 

B

A

G

 INTO THE

DE

BR

I

S

 

B

UCKET AND

EXPAND THE 

B

A

G

 A

G

AIN

S

T

THE DE

BR

I

S

 

B

UCKET 

S

IDE

S

PLACE 

B

A

G

'

S

S

LIDE-

G

ATE

HE

R

E

INSTALLING THE DUST BAG

R

EMOVE DE

BR

I

S

B

UCKET F

R

OM

B

UCKET 

S

LIDE

LATCHE

S

S

WIN

G

 THE TWO

B

UCKET 

S

LIDE

LATCHE

S

 DOWN

REMOVING THE DEBRIS BUCKET

HAN

G

 DE

BR

I

S

B

UCKET ON 

B

UCKET

S

LIDE LATCHE

S

B

UCKET

S

LIDE

LATCH

S

WIN

G

 THE TWO

B

UCKET 

S

LIDE

LATCHE

S

 UP

REPLACING THE DEBRIS BUCKET

Professional Installation By:

Manufactured By: