SPLIT   TYPE   -­‐   48v   DC   AIR   CONDITIONER   

MODEL   DC4812VRF   

   

Users   Guide   

IMPORTANT   NOTICE   

This   is   a   DC   (Direct   Current)   powered   device   and   relies   upon   a   48v   DC   

power   source.   The   DC   power   to   the   baKeries   may   be   provided   by   solar   

or   other   means.   This   user   guide   does   not   address   power   issues   and   

assumes   you   have   a   proper   supply   of   power.   Please   consult   with   the   
appropriate   resource   for   power   problems.      

   

You   may   find   the   informaQon   needed   to   correct   power   problems   by   

contacQng   your   solar   or   HVAC   installer   or   by   reviewing   informaQon   

provided   by   the   manufacturers   of   the   baKeries,   charge   controller,      or   

solar   panels,   etc.,   or   by   contacQng   your   local   distributor.         
Visit   LezeQ-­‐tech.com   for   more   informaQon.   

1   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

WARNING!

   

   

This   unit   uses   high   voltage   DC   power.   Capacitors   

within   the   unit   may   contain   dangerous   power   even   
aXer   the   power   supply   has   been   disconnected.      
   

Refer   any   service   to   a   qualified   professional.   See   
page   15   for   service   informaQon.   
   

Capacitors   MUST   BE   DISCHARGED   before   servicing   
any   electrical   components   of   this   unit!   

2   

48v   DC   AIR   CONDITIONER   

MODEL   DC4812VRF   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

Contents   

NOTICE   FOR   EUROPEAN   CUSTOMERS   

SAFETY   PRECAUTIONS   

IDENTIFICATION   OF   PARTS   

OPERATING   INSTRUCTIONS   

CARE   AND   MAINTENANCE   
TROUBLESHOOTING   TIPS   

   

European    NoQce………………………………………………………………………………………………………………..….4   

Warning    .......................................................................................................................................5      

CauQon    ........................................................................................................................................    6   

IdenQficaQon    of    Parts...................................................................................................................7   
OperaQng    InstrucQons..................................................................................................................8   

Care    &    Maintenance    ..................................................................................................................10   

TroubleshooQng    Guide    ..............................................................................................................12   

Service    and    Repair……………………………………………………………………………………………………………….15   

3   

48v   DC   AIR   CONDITIONER   

MODEL   DC4812VRF   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

NoQce   for   Users   in   European   Countries   

When   using   this   air   condi3oner   in   the   European   countries,   please   read   the   following   

informa3on:   

   

This   appliance      can   be   used   by   children   aged   from   8   years   and   above   and   persons   with   

reduced   physical,   sensory   or   mental   capabiliQes,   or   lack   of   experience   and   knowledge   if   
they   have   been   given   supervision   or   instrucQon   concerning   use   of   the   appliance   in   a   

safe   way   and   understand   the   hazards   involved.   Children   should   not   play   with   the   

appliance.   Cleaning   and   user   maintenance   must   not   be   performed   by   children   without   
supervision.   

DISPOSAL:   

Do   not   dispose      of   this   product   as   unsorted   municipal   waste.   CollecQon   

of   such   waste   separately   for   special   treatment   is   necessary.   It   is   prohibited   to   

dispose   of   this   appliance   in   domesQc   household   waste.   For   disposal,   there   are   
several   possibiliQes:   

   
A)   The   municipality   has   established   collecQon   systems,   where   electronic   waste   can   

be   disposed   of   at   least   free   of   charge   to   the   user.   

   
B)   When   buying   a   new   product,   the   retailer   will   take   back   the   old   product   at   least   

free   of   charge.   
   

C)   The   manufacturer   will   take   back   the   old   appliance   for   disposal   at   least   free   of   

charge   to   the   user.   
   

D)   As   old   products   contain   valuable   resources,   they   can   be   sold   to   scrap   metal   

dealers.   
   

Wild   disposal   of   waste   in   forests   and   landscapes   endangers   your   health   when   
hazardous   substances   leak   into   the   ground-­‐water   and   find   their   way   into   the   food   

chain.   

4   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

To   prevent   injury   to   the   user   or   other   people   and   property   damage,   the   following   instrucQons   

must   be   followed.   Incorrect   operaQon   due   to   ignoring   of   instrucQons   may   cause   harm   or   damage.   

SAFETY   PRECAUTIONS

   

This   unit   uses   capacitors   and   may   have   high   voltage   acQve   even   aXer   power   has   been   

disconnected.   Make   sure   to   discharge   capacitors   before   servicing   any   electrical   components   of   the   

unit.   
   

Don’t   expose   your   body   directly   to   the   cool   air   for   prolonged   period.   
   

Never   poke   fingers,   sQcks,   or   other   objects   in   the   air   inlet   and   outlet   vents.   

   
Never   aKempt   to   repair,   relocate,   or   modify   the   air   condiQoner   yourself.   Always   contact   qualified   

service   personnel.   
   

Do   not   operate   your   air   condiQoner   in   a   wet   room   such   as   a   bathroom   or   laundry   room.   

      
In   the   event   of   any   abnormaliQes   such   as   a   burning   smell,   immediately   switch   off   the   device   and   

disconnect   power   from   the   outdoor   unit.   Contact   your   service   partner.   

   
Always   switch   off   the   device   and   disconnect   power   before   you   start   to   clean   it.   

   
Contact   an   authorized   installer   for   installaQon   of   this   unit.   Contact   an   authorized   service   

technician   for   repair   or   maintenance   of   this   unit.      

   
This   appliance   is   not   intended   for   use   by   persons   (including   children)   with   reduced   physical,   

sensory   or   mental   capabiliQes,   or   lack   of   experience,   unless   they   have   been   given   supervision   or   
instrucQon   concerning   use   of   the   appliance   by   a   person   responsible   for   their   safety.   Children   

should   be   supervised   to   ensure   that   they   do   not   play   with   the   air   condiQoner.   

DANGER   

This   unit   uses   high   voltage   DC   power.   Capacitors   
within   the   unit   may   contain   dangerous   power   even   aXer   

the   power   supply   has   been   disconnected.   Refer   any   
service   to   a   qualified   professional.   Capacitors   MUST   BE   

DISCHARGED   before   servicing   any   electrical   
components   of   this   unit!      

5   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

Never   actuate   any   switches   with   a   wet   hand.   It   may   cause   an   electric   shock.      

   

Never   use   the   device   for   any   other   purpose   than   the   intended   use.   Never   place   food,   precision   
instruments,   plants,   animals,   paint,   etc.   on   the   unit.   

   
Do   not   expose   plants   or   animals   directly   to   the   air   flow.      

   

Never   clean   the   air   condiQoner   with   water.   Never   use   combusQble   cleaning   agents   as   these   could   
cause   a   fire   or   deformaQon.   

   
Never   place   any   burning   objects   close   to   the   device   if   they   could   be   directly   affected   by   the   emiKed   

air.   

   
Never   step   on   to   the   outdoor   device   and   never   place   anything   on   it.   

   

Never   use   an   unsteady   or   rusty   base.   
   

Never   install   the   air   condiQoner   in   places   where   combusQble   gas   can   be   emiKed.   Gas   may   collect   
and   cause   an   explosion.   

   

Never   allow   the   air   condiQoner   to   run   for   too   long   with   the   doors   or   windows   open,   or   if   the   
humidity   is   very   high.   

DANGER   

This   unit   uses   high   voltage   DC   power.   Capacitors   
within   the   unit   may   contain   dangerous   power   even   aXer   

the   power   supply   has   been   disconnected.   Refer   any   
service   to   a   qualified   professional.   Capacitors   MUST   BE   

DISCHARGED   before   servicing   any   electrical   
components   of   this   unit!      

SAFETY   PRECAUTIONS

   

6   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

IDENTIFICATION   OF   PARTS   

7   

DC4812VRF   Indoor   Unit

   

1.   Front   panel   

2.   Air   inlet   
3.   Air   filter   (under   the   panel)   

4.   Air   outlet   
5.   Horizontal   air   flow   grille   

6.   VerQcal   air   flow   louver   (inside)   

7.   Display   panel   
8.   ConnecQng   pipe,   drain   hose   

   

DC4812VRF   Outdoor   Unit   

9.   ConnecQve   cable      

10.   ConnecQng   pipe   
11.   Stop   valve   

Digital   Display   

 


background image

OPERATING   INSTRUCTIONS   

8   

NOTE:   This   manual      does   not   include   Remote   Controller   OperaQons,   see   the   remote      control   user   guide   

for   details.   

OperaQng   Temperature   

Cooling   

HeaQng   

DehumidificaQon   

Indoor   (F/C)   

62-­‐90/12-­‐32   

32-­‐86/0-­‐30   

50-­‐90/10-­‐32   

Outdoor   (F/C)   

32-­‐122/0-­‐50   

5-­‐86/-­‐15-­‐30   

32-­‐122/0-­‐50   

1.   OpQmum   performance   will   be   achieved   within   these   

operaQng   temperatures.   If   air   condiQoner   is   used   

outside   of   the   above   condiQons,   certain   safety   

protecQon   features   might   acQvate.   

2.   If   the   air   condiQoner   runs   for   a   long   Qme   in   cooling   

mode   and   the   humidity   is   high   (over   80%),   condensed   

water   may   drip   out   of   the   unit.   Please   set   the   verQcal   air   

flow   louver   to   its   maximum   angle   (verQcally   to   the   floor),   

and   set   HIGH   fan   mode.   

Manual   Opera3on

   

Units   are   equipped   with   a   switch   to   run   emergency   operaQon   

mode.   It   can   be   accessed   by   opening   the   front   panel.   This   

switch   is   used   for   manual   operaQon   in   case   the   remote   

controller   is   lost   or   inoperaQve.   

NOTE

   

The   unit   must   be   turned   off   before   operaQng   the   manual   

control   buKon.   If   the   unit   is   operaQonal,   conQnue   

pressing   the   manual   control   buKon   unQl   the   unit   is   off.   

This   is   NOT   the   recommended   way   to   operate   the   unit.   

To   restore   the   remote   controller   operaQon,   use   the   

remote   controller   directly.   

Adjust   the   horizontal   louver   

using   the   remote   controller.      

   

Adjust   the   verQcal   louver   

manually.   To   set   the   verQcal   

airflow   (Up-­‐-­‐Down)   direcQon   

perform   this   funcQon   while   the   

unit   is   in   operaQon.      

   

Use   the   remote   controller   to   

adjust   the   air   flow   direcQon.   The   

horizontal   louver   can   be   moved   

at   a   range   of   6⁰   for   each   press,   

or   swing   up   and   down   

automaQcally.      

   

Please   refer   to   the   DC4812VRF   

REMOTE   CONTROL   USER   GUIDE   

Air   Flow   DirecQon   control   

Cau3on   

Do   not   operate   the   air   condiQoner   for   long   periods   with   

the   air   flow   direcQon   set   downward   in   cooling   or   

dehumidifying   mode.   Otherwise,   condensaQon   may      

occur   on   the   surface   of   the   horizontal   louver   causing   

moisture   to   drop   on   the   floor   or   on   furnishings.   Do   not   

move   the   horizontal   louver   manually   unless   it   is   necessary,   

always   use   the   remote   controller.      

   

When   the   air   condiQoner   is   started   immediately   aXer   it   

was   stopped,   the   horizontal   louver   might   not   move   for   

approximately   10   seconds.   Open   angle   of   the   horizontal   

louver   should   not   be   set   too   small,   as   COOLING   or   

HEATING   performance   may   be   impaired   due   to   restricted   

air   flow.   Do   not   operate   unit   with   horizontal   louver   in   

closed   posiQon.   When   the   air   condiQoner   is   connected   to   

power   (iniQal   power),   the   horizontal   louver   may   generate   a   

sound   for   10   seconds,   this   is   a   normal   operaQon.   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

OPERATING   INSTRUCTIONS   

9   

Auto   OperaQon

   

When   you   set   the   air   condiQoner   in   AUTO   mode,   it   will      

automaQcally   select   cooling,   heaQng,   or   fan   only   operaQon   depending   on      

what   temperature   you   have   selected   and   the   room   temperature.   The   air   

condiQoner   will   control   room   temperature   automaQcally   according   to   the   

temperature   point   set   by   you.   If   the   AUTO   mode   is   uncomfortable,   you   can   

select   desired   condiQons   manually.   

   

SLEEP   OperaQon

   

When   you   push   SLEEP   buKon   on   remote   controller   during   cooling,   heaQng,   or   

AUTO   operaQon,   the   air   condiQoner   will   automaQcally   increase   (cooling)   or   

decrease   (heaQng)   2⁰F   per   hour   for   the   first   2   hours,   then   hold   steady   for   the      

next   5   hours,   aXer   that   it   will   switch   off.   This   characterisQc   maintains   both      

energy   saving   and   comfortable   night   operaQon.   

   

DehumidificaQon   (Drying)   OperaQon   

The   fan   speed   will   be   automaQcally   controlled   under   this   operaQon.   During   

dehumidificaQon   operaQon,   if   the   room   temperature   is   lower   than   10C   (50F),   

the   compressor   stops   operaQon   and   restarts   unQl   the   room   temperature   is   

above   12C   (54F).   

   

OpQmal   OperaQon

   

To   achieve   opQmal   performance,   please   note   the   following:      

   

Adjust   the   air   flow   direcQon   correctly   so   that   it   is   not   directed   on   people.   

      

Adjust   the   temperature   to   achieve   the   highest   comfort   level.   Do   not   

adjust   the   unit   to   excessive   temperature   levels.   

   

Close   doors   and   windows   on   COOL   or   HEAT   modes,   or   performance   

may   be   reduced.      

   

Use   TIMER   ON   buKon   on   the   remote   controller   to   select   a   Qme   you   want      

to   start   your   air   condiQoner.   

   

Do   not   put   any   object   near   air   inlet   or   outlet,   as   the   efficiency   of   the      

air   condiQoner   may   be   reduced   and   the   air   condiQoner   may   stop   running.   

   

Keep   away   from   electrical   wires,   lighQng   ballast,   or   wireless   devices   that   may      

interfere   with   controller   or   operaQons.   

   

Clean   the   air   filter   periodically,   otherwise   cooling   or   heaQng   performance   

may   be   reduced.   

   

Do   not   operate   unit   with   horizontal   louver   in   closed   posiQon.

   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

CARE   AND   MAINTENANCE   

10   

A   cloth   dampened   with   cold   water   may   be   used   on   the   

indoor   unit   if   it   is   very   dirty,   then   wipe   it   with   a   dry   

cloth.   Do   not   use   a   chemically   treated   cloth   or   duster   to   
clean   the   unit.   Do   not   use   benzene,   thinner,   polishing   

powder,   or   similar   solvents   for   cleaning.   These   may   
cause   the   plasQc   surface   to   crack   or   deform.   Never   use   

water   hoKer   than   40C/104F   to   clean   the   front   panel,   it   

could   cause   deformaQon   or   discoloraQon.   CAUTION   
Power   supply   must   be   disconnected   before   cleaning   the   

indoor   unit.   To   clean,   wipe   with   a   soX,   dry   cloth.   Do   not   
use   bleach   or   abrasives.      

A   clogged   or   dirty   air   filter   reduces   the   efficiency   of   this   

unit.   Please   clean   the   filter   once   every   2   weeks.   

   
1.   LiX   the   indoor   unit   panel   up   to   an   angle   unQl   it   stops   

with   a   clicking      sound.   For   some   models,   please   use   
suspension   bars   to   prop   up   the   panel.   

2.   Take   hold   of   the   handle   of   the   air   filter   and   liX   it   up   

slightly   to   take   it   out   from   the   filter   holder,   then   pull   it   
downwards.   

3.   Remove   the   AIR   FILTER   from   the   indoor   unit.   Clean   
the   AIRFILTER   once   every   two   weeks.   Clean   the   

AIRFILTER   with   a   vacuum   cleaner   or   water,   then   dry   it   in   

a   cool   place.      
   

Cleaning   the   opQonal   Air   Freshening   Filter:   

   
   

   
   

4.   Remove   the   Air   Freshening   Filter   from   its   

support   frame   (on   some   models).   The   opQonal   

filter   includes:      
   

Plasma   Dust   Collector/Silver   Ion   filter/
Biofilter/Vitamin   C   filter/   3M   air   purifier   filter,   

etc.      

   
The   removal   and   installaQon   methods   are   

slightly   different,   see   the   pictures.   Clean   it   
with   vacuum   cleaner   and   damp   cloth,   then   dry   

it   in   cool   place.   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

11   

CARE   AND   MAINTENANCE   

Do   not   touch   the   Plasma   Dust   Collector   Filter   within   10   

minutes   aXer   opening   the   front   panel,   it   may   cause   an   

electric   shock.      
   

5.   Install   the   air   freshening   filter   back   into   posiQon.      
   

6.   Insert   the   upper   porQon   of   air   filter   back   into   the   

unit,   taking   care   that   the   leX   and   right   edges   line   up   
correctly   and   place   filter   into   posiQon.   

   
Replacement   of   air   filter   and   air   freshening   filter   

1.

Remove   the   air   filter.   

2.

Remove   and   clean   the   air   freshening   filter.   

3.

OpQonal   -­‐install   a   new   air   freshening   filter.   

4.

Reinstall   the   air   filter   and   securely   close   the   front   

panel.   

   

PreparaQon   for   end-­‐of-­‐season   or   extended   shut-­‐down:   
   

If   you   plan   to   not   use   the   unit   for   a   long   Qme,   perform   

the   following:   
1.   Clean   the   indoor   unit   and   filters.      

2.   Operate   the   fan   for   about   half   a   day   to   dry   the   inside   

of   the   unit.      

   
3.   Stop   the   air   condiQoner   and   disconnect   power.      

Remove   the   baKeries   from   the   remote   controller.   
   

4.   The   48v   baKeries   and   solar   etc.,   should   be   

disconnected   and   stored   per   manufacturers   
instrucQons.   Do   not   aKempt   to   do   this   yourself.   Contact   

your   service   provider.   
   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

TROUBLESHOOTING   TIPS   

12   

Normal   funcQon   of   the   air   condiQoner   

The   following   events   may   occur   during   normal   operaQon.   

   

   ProtecQon   of   the   air   condiQoner   prevents   the   compressor   from   starQng   again   unQl      

3-­‐4   minutes   aXer   it   stops.   

   The   unit   is   designed   to   not   blow   cold   air   during   heaQng   mode,   when   the   indoor   heat   exchanger   is         

in   one   of   the   following   three   situaQons   and   the   set   temperature   has   not   been   reached:   

            A)   When   heaQng   has   just   started.   
            B)   DefrosQng.   

            C)   Low   temperature   heaQng.   

•   

The   indoor   or   outdoor   fan   stops   running   when   defrosQng.   

   Frost   may   be   generated   on   the   outdoor   unit   during   heat   cycle   when   outdoor   temperature   is   low   and   

humidity   is   high   resulQng   in   lower   heaQng   efficiency   of   the   air   condiQoner.   During   this   condiQon   the   

air   condiQoner   will   stop   heaQng   operaQon   and   start   defrosQng   automaQcally.   The   Qme   to   defrost      

may   vary   from   4   to   10   minutes   according   to   the   outdoor   temperature   and   the   amount   of   frost   built      
upon   the   outdoor   unit.   

   A   white   mist   may   generate   due   to   a   large   temperature   difference   between   air   inlet   and   air   outlet      

on   COOL   mode   in   an   indoor   environment   that   has   a   high   relaQve   humidity.   A   white   mist   may      

generate   due   to   moisture   generated   from   defrosQng   process   when   the   air   condiQoner   restarts   in   
HEAT   mode   operaQon   aXer   defrosQng.   

   Noise.   You   may   hear   a   low   hissing   sound   when   the   compressor   is   running   or   has   just   stopped      

running.   It   is   the   sound   of   the   refrigerant   flowing   or   coming   to   a   stop.   You   can   also   hear   a   low   "squeak“   

sound   when   the   compressor   is   running   or   has   just   stopped   running.   This   is   caused   by   heat   expansion   

and   cold   contracQon   of   the   plasQc   parts   in   the   unit   when   the   temperature   is   changing.   A   noise   may   be   
heard   due   to   louver   restoring   to   its   original   posiQon   when   power   is   turned   on.   

   Dust   blows   from   the   indoor   unit.   This   is   a   normal   condiQon   when   the   air   condiQoner   has   not   been      

used   for   a   long   Qme   or   during   first   use   of   the   unit.   

      A   peculiar   smell   comes   from   the   indoor   unit.   This   may   be   caused   by   the   indoor   unit   giving   off   smells   

permeated   from   building   material,   from   furniture,   or   smoke.   

      The   air   condiQoner   turns   to   FAN   only   mode   from   COOL   or   HEAT   mode.   When   indoor   temperature      

reaches   the   temperature   sesng   on   air   condiQoner,   the   compressor   may   stop   automaQcally,   and      the      

air   condiQoner   turns   to   FAN   only   mode.   The   compressor   will   start   again   when   the   indoor   temperature      
rises   on   COOL   mode   or   falls   on   HEAT   mode   to   the   set   point   

   

   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

13   

TROUBLESHOOTING   TIPS   

   The   air   condiQoner   runs   anQ-­‐mildew   funcQon   aXer   turning   off   the   unit.   When   turning   off   the   unit   

under   COOL   (AUTOCOOL,   FORCED   COOL)   and   DRY   mode,   the   air   condiQoner   will   run   in   this   funcQon   
for   7-­‐10   minutes,   then   stop   the   operaQon   and   turn   off   the   unit   automaQcally.      AnQ-­‐mildew   turns   off      

on   HEAT   mode,   the   unit   will   conQnue   operaQng   for   about   30   seconds   at   LOW   fan   speed   then   stop      

the   operaQon   and   turn   off   the   unit   automaQcally.   
   

   Dripping   water   may   form   on   the   surface   of   the   indoor   unit   when   cooling   in   high   relaQve   

humidity.   Adjust   the   horizontal   louver   to   the   maximum   air   outlet   posiQon   and   select   HIGH   fan   speed.   

   

   HeaQng   mode.   The   air   condiQoner   draws   in   heat   from   the   outdoor   unit   and   releases   it   via   the   indoor   unit      

during   heaQng   operaQon.   When   the   outdoor   temperature   falls,   heat   drawn   in   by   the   air   condiQoner      
decreases   accordingly.   At   the   same   Qme,   heat   loading   of   the   air   condiQoner   increases   due   to   larger   

difference   between   indoor   and   outdoor   temperature.   If   a   comfortable   temperature   can't   be   achieved   

by   the   air   condiQoner,   we   suggest   you   use   a   supplementary   heaQng   device.   
   

   Auto-­‐restart   funcQon.      Any   power   failure   or   drop   in   DC   voltage   below   46v   will   stop   the   unit   completely      

unQl   power   is   restored   or   baKeries   charge   above   48v.   When   power   restores,   the   unit   restarts   automaQcally   

with   all   the   previous   sesngs   preserved   by   the   memory   funcQon.   

   

   Power   is   on   but   unit   wont   run.   Power   surge,   nearby   lighQng   ballast,   unshielded   electrical   wiring,   wireless      

interference,   use   of   other   IR   remote   controllers   (like   used   for   TV   etc.)   or   other   electronic   interference      
nearby   may   cause   the   unit   and/or   the   remote   control   IR   receiver   to   malfuncQon.   Disconnect   the   unit      

completely   from   power   for   30   seconds   and   then   re-­‐connect   the   unit   with   power   again.   Push   the   ON/OFF      
buKon   on   the   remote   controller   to   restart      operaQon.   Do   not   allow   direct   sunlight   to   shine   on   the   remote      

control   IR   receiver   of   the   indoor   unit.   

   

      The   protecQon   of   outdoor   low   temperature.   The   protecQon   of   outdoor   low   temperature   can   be      

acQvated   only   in   the   HEATING   mode.   The   unit   will   stop   operaQng   and   display   "P3“   on   the   LCD   window   
of   the   indoor   unit   when   the   outdoor   temperature   is   lower   than   5F(-­‐15C)   for   one   hour,   but   the   indoor   

unit   in   this   situaQon   can   sQll   receive   the   signal   from   the   remote   controller.   The   unit   will   restart      
automaQcally   with   all   the   previous   sesngs   preserved   by   the   memory   funcQon   when   the   outdoor      

temperature   is   or   higher   than   11F   (-­‐12C)   for   10   minutes   and   the   compressor   stops   operaQng   for      

more   than   one   hour,   or   when   the   outdoor   temperature   is   or   higher   than   41F   (5C)   for   10   minutes.   
   

   
   

   
   

   

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

14   

TROUBLESHOOTING   TIPS   

Your   dealer   or   service   technician   will   have   access   to   the   LEZETi   SERVICE   

MANUAL   which   contains   complete   service   and   diagnosQc   informaQon   not   

available   to   consumers.   If   your   service   technician   needs   advanced   support   or   

documents   please   have   them   contact   you   distributor   or   visit   

www.lezeQ-­‐tech.com

      

Version(2.1(

DC4812VRF(

(

(

(

((

(

 


background image

15   

ANen3on   Professional   Service   Personnel:      

   

This   unit   has   

capacitors   located   in   mul3ple   places   within   the   system.

      

You   must   idenQfy   and   discharge   all   capacitors   before   servicing      
this   unit!      

   
Please   see   the   LEZETi      DC4812VRF   SERVICE   MANUAL   before      
performing   any   service.   Licensed   HVAC   technicians   may   obtain   the   service      

manual   at   no   cost   from   HSE   support   department.   
   

WARNING   

High   Voltage   DC   Power

   

MAY   BE   ACTIVE      

AFTER   FULL   DISCONNECTION   

Users   Do   Not   Ever   ANempt   to   Service   This   Unit.   Contact   a   Professional.   