Full Text Searchable PDF User Manual

Pioneering “Smart” Pedi-Spas
PEDICURE SPA USER MANUAL
ULTIMA
®
Before Operating the unit, please read this manual thoroughly and retain it for future reference
.
RECEIVING AND INSPECTION:
TRADEMARK DISCLAIMER
Vigor, Stellar, Ultima and Princess Seat are the registered trademarks of Lexor. Reproduction or reuse of part or all of trademarks are
expressly prohibited without written permission from Lexor. Due to limitation of the printing process, product colors shown might look
different from actual colors. Lexor will not be responsible for any misprint of this advertisement. Lexor’s footspa specification and prices
may change without prior notice. Pedicure Spas are intended for professional used only, always follow your State Board’s sanitation and
disinfectant guideline.
PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival. It is
important that you notify the driver and insist on a notation of the damage. Make this
notation directly on the freight company’s waybill or bill of lading. Failure to note damage on
the waybill or bill of lading may impede and/or prevent any claims that you may have
against the freight carrier.
If missing parts or damage is found. Please notify the carrier at once and request an
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear receipt
for goods that have been damaged in transit, you do so at your own risk and expense.

2
Table of Contents
SAFETY PRECAUTIONS: ................................................................................................. 3
Parts
Identifying Parts for Ultima® Model ................................................................................... 4
SPA to SPA RECOMMENDED CLEARANCE: .................................................................. 5
Wall Clearance: ................................................................................................................. 5
MANICURE TRAY/ ARMREST / BACK REST INSTALLATION ........................................ 6
Up/Down Swinging Armrest: ........................................................................................................ 6
Plumbing Connections: ...................................................................................................... 7
Power Drain (optional): ................................................................................................................ 7
Gravity Drain (No Drain Pump): ................................................................................................... 8
Plumbing Flow Pattern for Power Drain: ...................................................................................... 8
Plumbing Flow Pattern for Gravity Drain: ..................................................................................... 9
HOT AND COLD WATER SUPPLY LINES ................................................................................. 9
ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS ....................... 11
OPERATION AND CARE INSTRUCTIONS .................................................................... 12
Auto-Fill™: ............................................................................................................................. 12
JET COVER REMOVAL & INSTALLATION: ................................................................... 14
JET HOUSING REMOVAL & INSTALLATION ................................................................ 15
MASSAGE SYSTEM & REMOTE CONTROLLER: ......................................................... 16
Safety Requirements for Pedicure Spas ................................................................................ 18

3
____________________________________________________
Safety Precautions
READ AND FOLLOW INSTRUCTIONS CAREFULLY
SAFETY PRECAUTIONS:
Warning
THIS PRODUCT IS FOR INDOOR USE ONLY
DISCONNECT POWER SUPPLY CORD BEFORE SERVICING
This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT
INTERRUPTER (GFCI), and the GFCI shall be tested regularly for continued protection and correct operation. If a
Class A GFCI protected outlet is not available, DO NOT USE THIS PRODUCT! Please contact a licensed
electrician for installation of a Class A GFCI according to local electric codes, or equivalent.
Warning
DO NOT USE
if you are diabetic, have poor circulation, or if any area of your feet or legs
is inflamed or has an open sore. Consult your physician before using if you have any kind of
fungal infection, swelling, fracture or persistent pain.
Warning
TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE
THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME
•
LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE
•
UTILISER SEULEMENT A L’INTERIEUR
•
COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE, AU NETTOYAGE
Warning
1. Excessive water temperature is dangerous and should be checked BEFORE use.
2. Maximum temperature of the water should never exceed 100 degrees F.
3. DO NOT STEP/ STAND IN FOOT BASIN.
4. Always enter and exit the Pedicure Spa slowly and carefully.
5. NEVER bring and / or operate any electrical devices into or near the Pedicure Spa.
6. Maximum load in spa chair is 250lbs (114kg).
Warning
If a crack in the GLASS BOWL occurs, DO NOT handle unless the proper attire and
equipment is used. Discontinue use of the bowl until proper replacement is arranged. You
may be held accountable for any injury that may occur. Lexor is not liable for any injury
that may occur.
STATES’ NOTICE

4
In the common wealth of most of the States, all pedicure spas shall be installed for Commercial usage in the
states, are required to have backflow preventer. This equipment shall be installed between the water inlets and
the spa at Salon’s cost.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
__________________________________________________
Identifying Parts
Identifying Parts for Ultima® Model
(Pedicure Whirlpool with Massage System)
1. Head Rest
2. Chair Cushion with
Massage
3. Armrest Cushion
4. Massage Remote Control
5. Manicure-Tray (Optional)
6. Angelic Bowl
7. Footrest
8. Sani-Drain™ System with

5
Discharge On/Off Knob
9. Jet On/Off Knob & Auto-
Fill™
10. Hot/Cold Water Mixer
Valve
11. Flex Water Filler/Spray
Spout
12. Up/Down Armrest
13. Handbag (purse) Hook
14. Tub Light
15. Water Level Sensor
16. Drain Stopper
17. Pure-Flo™ Jet
18. Adjustable height Tech
Stool for Pedicure
_______________________________________________________
Installation
SPA to SPA RECOMMENDED CLEARANCE:
Wall Clearance:

6
_
_____________________________________________________
Installation
MANICURE TRAY/ ARMREST / BACK REST INSTALLATION
Up/Down Swinging Armrest:
1. Plug-In the manicure trays and attach the purse hook. (1 Supplied)
Back Rest:

7
1. To set backrest up: Lift up the backrest until a “Click” is heard. Make sure the lever is locked
before operating.
2. To fold down backrest: Lift up lever handle located on the left side / bottom of Chair.
_______________________________________________________
Installation
Plumbing Connections:
Warning
Before any connection, pay attention to these subjects:
1. Debris or residue may become lodged into the Hot and Cold hoses during construction, which may clog
the Hot and Cold Mixer. To clean, drain a good amount of water from water hoses to bucket before
connecting them to the pedicure spa. Failure to do so may void your Warranty.
2. Hooking up a used Hot/Cold flex hose is not recommended since debris from broken rubber seal might
clog water mixer. Failure to do so may void your Warranty.
3.
Backflow preventer: Due to differences in construction lay-out of your Salon and City’s plumbing code,
please contact your local Plumber to fulfill your needs as required. Backflow Preventers are not supplied
by the pedicure spa manufacturer.
4.
Check valve is an optional part and supplied free of charge for your convenience. Factory is not liable for
this Check valve.
5.
Maximum Inlet water pressure must be under 75 PS
I
.
Power Drain (optional):

8
_______________________________________________________
Installation
Gravity Drain (No Drain Pump):
Plumbing Flow Pattern for Power Drain:

9
_______________________________________________________
Installation
Plumbing Flow Pattern for Gravity Drain:
HOT AND COLD WATER SUPPLY LINES
Carefully connect ½” ID supply hoses (not provided) to fresh water sources. Shut-off valves (not
provided) should be utilized. Valves should be placed outside the tub for easy access.
Before water line connections, please follow below:
Determine if your spa chair is used for a new construction of a salon or a replacement spa chair.
1. New construction: Make sure to remove any and all debris and/or dust from current hot cold
water pipes before hooking up to spa. Suggested direction to remove debris: turn on water and
drain into a bucket or container. See illustration below:
2. Replacement Spa: Always use new hot/cold water hoses when connecting a new spa chair to
prevent debris, such as old rubber particles, from clogging drain.

10
______________________________________________________________
Installation
CONNECT DRAIN WITH POWER DRAIN (PUMP) OR GRAVITY DRAIN (NO PUMP)
Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate traps.
Connect drain to meet local plumbing codes.
Rubber connection to the drain should be removable for easy service and should not be permanent to
prevent damages.

11
________________________________________________
Spa Specifications
ELECTRICAL AND PEDICURE SPA COMPONENT
SPECIFICATIONS
All electrical connections MUST be made by a qualified, licensed electrician in accordance with Local & National
Electrical and Building Codes. A 110V-50/60 Hz, 15 Amp, GFCI protected grounded circuit MUST be used to
supply power to the Pedicure Spa. A dedicated circuit must be used with a GFCI. All wiring must conform to
National & Local Electrical Codes
.
WARNING:
IT IS EXTREMELY IMPORTANT THAT THE FOOT SPA OPERATES WITH GFCI PROTECTION
VERY IMPORTANT Both back of chair and seat are adjustable. When both are at maximum positions one must
allow 18”(44cm) from back wall to foot spa. This minimum distance assures unobstructed recline. Failure to follow
this required dimension might damage your spa components and plumbing connections, which will void your
warranty.
PEDICURE SPA SPECIFICATIONS:
•
Construction:
Marble
composite,
high gloss, acetone-proof gel coat.
•
Two (2) electro-mechanical knobs control the drain and whirlpool.
•
Electro-mechanically operated reclining, massaging, and sliding seat with hand held control.
•
One (1) pipe-less whirlpool jet. (Pipe-free technology)
•
Power drain (optional) or Gravity drain (no drain pump)
•
Extendable water spray positioned well above water line, air gap is accommodated with back-flow
prevention required by plumbing code
•
Armrest swing up / down.
SPECIFICATIONS
Spa Dimensions &
Weights
Vigor = 28” (W) x 56” (L). Stellar = 26” (W) x 54” (L). Ultima = 23” (W) x 55” (L)
All Models fully reclined: 74” (L). With Manicure Tray Installed: 46” (W)
Empty Weight: ~ 200 lbs. Shipping Weight: ~ 260 lbs.
Adjustable Stool Height
Pedicure Stool: 12” – 13”.
Spa Water Capacity
~ 4-5 US Gallon
Jet Motor
120 VAC. at 85W 60Hz
Massage Motors,
Seat Sliding & Reclining
24VDC, 2.5A x 5
Discharge Pump
Motor – 120V at 85W 60 Hz Maximum vertical lift: 3ft . Flow rate 500 GPH @ floor level
Power source
115 VAC, 60HZ. Power needed per spa chair = 6 Amp
Electrical Switches
One (1) electro-mechanical knob for the Whirlpool. Rated at 5A contact.
One (1) electro-mechanical knob for the Drain. Rated at 5A contact.
Plug & Play Installation
Installation should be made with connection at the external interface parts.
Please consult with your local plumber.
Safety
Ultima® Pedicure Spa is UL listed.

12
_______________________________________________________
Operation and Care
OPERATION AND CARE INSTRUCTIONS
Auto-Fill™:
Automatic Auto-Fill™ cycle:
Water will automatically turn-off when optimal water level is detected by 2 sensors and followed with the
immediate start of Whirlpool jets for a duty cycle of thirty (30) minutes. The Auto-Fill™ cycle is safely
protected by 2 sensors, 3-minute time out and can be extended with a manually operative shut-off valve
located at the front panel.
Manual conversion:
Auto-Fill™ option can be simply reset to normal manual mode as a contingent system when automatic
operation becomes unavailable. Please call our Customer care for step by step instructions.
Panel Functional Switches & Operating Instructions:
Hot/Cold water faucet located at the center of the front panel.
1.1 Use faucet knob to adjust optimal water temperature at “H” (Left) or “C” (Right) directory.
1.2 Pull out and tilt down faucet knob to shut off water any time during the automatic or manual
operational cycle.
Warning
Must be used when spa chair is left unattended or for overnight procedures to
shut off water supply to basin.
Important!
Must scrub and clean water sensors frequently to ensure that water stops right
at sensor level. If necessary, clean using sponge buffer.

13
______________________________________________
Operation and Care
Auto-Fill™ / Jet Knob/Switch:
(
Dual-functional momentary switch located on the right side of the front panel
)
1.
To turn water on:
Turn knob clockwise for 1 second and release. Water will fill up to reach the
sensor level and activate the whirlpool jets to proceed a running duration of thirty (30) minutes automatically.
2.
To turn water off:
Turn knob clockwise for 1 second and release to turn off water. The switch can
be activated to turn on or turn off water any time during the Auto-Fill™ cycle, EXCEPT when water is at
sensor level.
3.
To turn On / Off the whirlpool jet:
Turn knob clockwise for 1 seconds and release. This Jet
cannot be turned on if water level is not at sensor level.
Drain Knob/Switch:
(Dual Action Electro-mechanical Switch located on the left side of the front panel)
When activating the switch, it will raise the drain-stopper and power up the drain pump (if exist) at the
same time.
3.1 To drain water: Turn the drain knob clockwise. Switch is activated.
3.2 To turn off the drain pump: Turn the drain knob counterclockwise.

14
______________________________________________
Operation and Care
JET COVER REMOVAL & INSTALLATION:
1.
Turn Counterclockwise to remove. Turn Clockwise to install.

15
______________________________________________
Operation and Care
JET HOUSING REMOVAL & INSTALLATION
1.
Turn clockwise to remove motor. Turn counterclockwise to install motor.

16
______________________________________________
Operation and Care
MASSAGE SYSTEM & REMOTE CONTROLLER:
1. Press Auto Button to start Auto mode. Press again to turn off massage.
Auto and Manual mode will run for duration of 15min.
2. Press any button (Rolling/Spot, Kneading, Tapping, Combine) to enter Manual mode.
3. Press Rolling/Spot to stop rolling up/down and stop at desired spot.
4. Press Intensity button to select tapping intensity.
5.
Vibro Button/LED is an option. Pressing this button will resume with Tapping action.
6.
Press any chair button (Recline, Incline, Backward, Forward) to move the chair to desired positions.

17
_______________________________________________
Operation and Care
NOTE : If the Massage Chair is not provided, then the end-user will need to install a UL listed and cUL/CSA
certified massage chair with
a suitable Class 2 Power Supply.
TOP MASSAGE CHAIR BASIC INSTALLATION INSTRUCTIONS:
Fig.1
Fig.3
Fig.2
Install seat cushion with 2 screw-Knobs
Lever the back massage and secure 2 hinge
screws onto the metal brackets.(Do not turn
the screws all the way in )
Leave 1/4” thread screw head for sliding
Install back shell with 4 screws as Fig.3
Drill 4 mounting holes ½”.Width=16.5”
Length=11 .Install seat frame and secure 4
screws from bottom base.Using the provided
stand-off to adjust the height of seat frame as
needed to allow seat frame to travel freely.
Controller PCB
Lift up back massage to engage
locking device. (Manually adjust
actuator rod to lock as needed)
Install back cushions.
Plug AC cord to power strip
Located inside of the tub base.

18
WARNING
Y
ou must always refer to your state or local guidelines for cleaning requirements
.
Overnight soaking with overdosed Chlorine may damage rubber part in basin
CLEANING PROCEDURE
IS REQUIRED BY STATE BOARDS
Note:
*** A cleaning log should be kept with each pedicure spa ***
Each State will have slight differences in cleaning policies, please check with your state’s Bureau of Barbering
and Cosmetology or Regulatory Authority for specific details.
Safety Requirements for Pedicure Spas
The Bureau of Barbering and Cosmetology requires that salons using whirlpool pedicure foot spas must
follow these disinfecting procedures to ensure proper cleaning and maintenance of the equipment and to
prevent the spread of bacterial or parasitic disease.
Violation of this section may result on an administrative fine and/or disciplinary action. Each foot spa that
is not in compliance with this section may result in a separate violation.
NOTE: Authority cited: Section 7312, Business and Profession Code. Reference: Section 7312 (e),
Business and Professsion Code.
Below is a suggestion for your pedicure spa chair’s cleaning procedure:
After Each Customer
1. All water shall be drained and all debris shall be removed from the spa basin.
2. The spa basin must be cleaned with soap or detergent and water
3. The spa basin must be disinfected with an EPA-registered disinfectant with demonstrated bactericidal,
fungicidal, and virucidal activity, which must be used according to manufacturer’s instructions.
4.
The spa basin must be wiped dry with a clean towel.
At the End of Each Day
1. The screen shall be removed, all debris trapped behind the screen shall be removed, and the screen and the
inlet shall be washed with soap or detergent and water.
2. Before replacing the screen, the screen shall be totally immersed in an EPA-registered disinfected with
demonstrated bactericidal, fungicidal and virucidal activity, which must be used according to the
manufacturer’s instructions.
3.
The spa system shall be flushed with low sudding soap and warm for at least 10 minutes, after which the spa
shall be rinsed and drained.
At Least Once A Week
1. The spa basin shall be filled completely with warm water and 1 teaspoon of 5.25% bleach for each gallon of
water, or a solution of Sodium Hypochlorite of approximately 50ppm used according to manufacturer’s
instructions.
2. The spa system shall be flushed with the bleach and water solution, or Sodium Hypochlorite solution, for 5-10
minutes and allowed to sit for 6-10 hours.
3.
The spa system shall be drained and flushed with water before use upon a patron.

19
WARNING
PROPER INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND/OR WARRANTY WILL BE NULL.
YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE
SAFELY. UL SAFETY RECOGNIZED FOR UNITED STATES AND CANADA.
LEXOR INC, 14800 GOLDENWEST STREET, WESTMINSTER CA 92683, USA
CUSTOMER CARE: TEL 1-800-559-3630 FAX: 1-714-622-1740
www.Lexor.com
©
2012 All Rights reserved. Design and Specifications are subject to change without notice