Pioneering “Smart” Pedi-Spas 

 

 

 

PEDICURE SPA USER MANUAL

 

 

ULTIMA

®

 

 
 
 

Before Operating the unit, please read this manual thoroughly and retain it for future reference

.

 

 
 

 

RECEIVING AND INSPECTION: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

TRADEMARK DISCLAIMER

 

 

Vigor, Stellar, Ultima and Princess Seat are the registered trademarks of Lexor.  Reproduction or reuse of part or all of trademarks are 
expressly prohibited without written permission from Lexor.  Due to limitation of the printing process, product colors shown might look 
different from actual colors. Lexor will not be responsible for any misprint of this advertisement. Lexor’s footspa specification and prices 
may change without prior notice.  Pedicure Spas are intended for professional used only, always follow your State Board’s sanitation and 
disinfectant guideline.  

 

PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival. It is 
important that you notify the driver and insist on a notation of the damage. Make this 
notation directly on the freight company’s waybill or bill of lading. Failure to note damage on 
the waybill or bill of lading may impede and/or prevent any claims that you may have 
against the freight carrier. 
 
If missing parts or damage is found.  Please notify the carrier at once and request an 
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear receipt 
for goods that have been damaged in transit, you do so at your own risk and expense.

 

 


background image

 

2

Table of Contents 

 
 

 

SAFETY PRECAUTIONS: .................................................................................................  3 

 

Parts 
Identifying Parts for Ultima® Model ................................................................................... 4

 

SPA to SPA RECOMMENDED CLEARANCE: ..................................................................  5

 

Wall Clearance: ................................................................................................................. 5

 

MANICURE TRAY/ ARMREST / BACK REST INSTALLATION ........................................  6

 

Up/Down Swinging Armrest: ........................................................................................................ 6

 

Plumbing Connections: ......................................................................................................  7

 

Power Drain (optional): ................................................................................................................ 7

 

Gravity Drain (No Drain Pump): ................................................................................................... 8

 

Plumbing Flow Pattern for Power Drain: ...................................................................................... 8

 

Plumbing Flow Pattern for Gravity Drain: ..................................................................................... 9

 

HOT AND COLD WATER SUPPLY LINES ................................................................................. 9

 

 
ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS ....................... 11

 

 
OPERATION AND CARE INSTRUCTIONS .................................................................... 12

 

Auto-Fill™: ............................................................................................................................. 12

 

 
JET COVER REMOVAL & INSTALLATION: ................................................................... 14

 

JET HOUSING REMOVAL & INSTALLATION ................................................................ 15

 

 
MASSAGE SYSTEM & REMOTE CONTROLLER: .........................................................  16

 

Safety Requirements for Pedicure Spas ................................................................................ 18

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 


background image

 

3

 
 
 
 
____________________________________________________

Safety Precautions

 

 
READ AND FOLLOW INSTRUCTIONS CAREFULLY 

 

SAFETY PRECAUTIONS:  

 

Warning  

THIS PRODUCT IS FOR INDOOR USE ONLY 

      

 

DISCONNECT POWER SUPPLY CORD BEFORE SERVICING 

 

This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT 
INTERRUPTER (GFCI), and the GFCI shall be tested regularly for continued protection and correct operation. If a 
Class A GFCI protected outlet is not available, DO NOT USE THIS PRODUCT! Please contact a licensed 
electrician for installation of a Class A GFCI according to local electric codes, or equivalent. 

 
 

 

Warning

 DO NOT USE 

if you are diabetic, have poor circulation, or if any area of your feet or legs    

                        is inflamed or has an open sore. Consult your physician before using if you have any kind of  
                        fungal infection, swelling, fracture or persistent pain.    
   

 

                                  

 

Warning

 

 TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE               

                     THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME 

 

 

LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE 

 

UTILISER SEULEMENT A L’INTERIEUR 

 

COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE, AU NETTOYAGE 

 

 

Warning 

1. Excessive water temperature is dangerous and should be checked BEFORE use. 

                       2. Maximum temperature of the water should never exceed 100 degrees F.                                                           
                       3. DO NOT STEP/ STAND IN FOOT BASIN.  
                       4. Always enter and exit the Pedicure Spa slowly and carefully.       
                       5. NEVER bring and / or operate any electrical devices into or near the Pedicure Spa. 
                       6. Maximum load in spa chair is 250lbs (114kg). 

 

 

Warning

                                        

                       If a crack in the GLASS BOWL occurs, DO NOT handle unless the proper attire and  
                       equipment is used. Discontinue use of the bowl until proper replacement is arranged. You  
                       may be held accountable for any injury that may occur. Lexor is not liable for any injury  
                       that may occur. 

                       

 

 STATES’ NOTICE 

 

 


background image

 

4

In the common wealth of most of the States, all pedicure spas shall be installed for Commercial usage in the 
states, are required to have backflow preventer. This equipment shall be installed between the water inlets and 
the spa at Salon’s cost. 

 
 

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 

__________________________________________________

Identifying Parts

                 

          

                                                                                                            

 

 

Identifying Parts for Ultima® Model

 

(Pedicure Whirlpool with Massage System) 

 

1. Head Rest                                                       
2. Chair Cushion with  
    Massage    

3. Armrest Cushion  
4. Massage Remote Control 
5. Manicure-Tray (Optional) 

6. Angelic Bowl  
7.  Footrest  
8.  Sani-Drain™ System with  

 


background image

 

5

      Discharge On/Off Knob 
9.   Jet On/Off Knob & Auto- 
       Fill™  
10.  Hot/Cold Water Mixer   
       Valve  

11.  Flex Water Filler/Spray  
       Spout 
12.  Up/Down Armrest 
13.  Handbag (purse) Hook 
14.  Tub Light 

15.  Water Level Sensor 
16.  Drain Stopper  
17.  Pure-Flo™ Jet  
18.  Adjustable height Tech 

Stool for Pedicure 

 

 

 

                       

_______________________________________________________

Installation

                  

 

SPA to SPA RECOMMENDED CLEARANCE:

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Wall Clearance:

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 


background image

 

6

 
 
 
   


_____________________________________________________

Installation 

 

MANICURE TRAY/ ARMREST / BACK REST INSTALLATION

 

 

 

Up/Down Swinging Armrest:

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                      

 

 
 
 
1.  Plug-In the manicure trays and attach the purse hook. (1 Supplied)

 

 

Back Rest: 

 

 
 
 

 
 
 
 
 
 
 

 

 


background image

 

7

 
 

1.  To set backrest up: Lift up the backrest until a “Click” is heard. Make sure the lever is locked 

before operating.

 

2.  To fold down backrest: Lift up lever handle located on the left side / bottom of Chair.

 

 

_______________________________________________________

Installation

 

 

Plumbing Connections:

 

 

 

Warning

  

Before any connection, pay attention to these subjects: 
 

1.  Debris or residue may become lodged into the Hot and Cold hoses during construction, which may clog 

the Hot and Cold Mixer. To clean, drain a good amount of water from water hoses to bucket before 
connecting them to the pedicure spa. Failure to do so may void your Warranty. 

2.  Hooking up a used Hot/Cold flex hose is not recommended since debris from broken rubber seal might 

clog water mixer. Failure to do so may void your Warranty. 

3. 

Backflow preventer: Due to differences in construction lay-out of your Salon and City’s plumbing code, 
please contact your local Plumber to fulfill your needs as required. Backflow Preventers are not supplied 
by the pedicure spa manufacturer.

 

4. 

Check valve is an optional part and supplied free of charge for your convenience.   Factory is not liable for 
this Check valve.

 

5. 

Maximum Inlet water pressure must be under 75 PS

I

.

 

 

 

Power Drain (optional):

 

   

 

 
 
 
 

 


background image

 

8

_______________________________________________________

Installation

 

 

Gravity Drain (No Drain Pump):

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                   

  

 

Plumbing Flow Pattern for Power Drain: 

 

 


background image

 

9

_______________________________________________________

Installation

  

 
Plumbing Flow Pattern for Gravity Drain: 

 

 

 

HOT AND COLD WATER SUPPLY LINES 

 

Carefully connect ½” ID supply hoses (not provided) to fresh water sources. Shut-off valves (not 
provided) should be utilized. Valves should be placed outside the tub for easy access. 
 
Before water line connections, please follow below: 
Determine if your spa chair is used for a new construction of a salon or a replacement spa chair. 

1.  New construction: Make sure to remove any and all debris and/or dust from current hot cold 

water pipes before hooking up to spa. Suggested direction to remove debris: turn on water and 
drain into a bucket or container.  See illustration below: 

    
 
 
 
 
 
 
 
 
 
 

 

2.  Replacement Spa: Always use new hot/cold water hoses when connecting a new spa chair to 

prevent debris, such as old rubber particles, from clogging drain. 

 


background image

 

10

______________________________________________________________

Installation

 

 

 

CONNECT DRAIN WITH POWER DRAIN (PUMP) OR GRAVITY DRAIN (NO PUMP) 

 
Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate traps.  
Connect drain to meet local plumbing codes. 
Rubber connection to the drain should be removable for easy service and should not be permanent to 
prevent damages. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 


background image

 

11

________________________________________________

Spa Specifications

  

 
ELECTRICAL AND PEDICURE SPA COMPONENT 
SPECIFICATIONS

 

 

All electrical connections MUST be made by a qualified, licensed electrician in accordance with Local & National 
Electrical and Building Codes. A 110V-50/60 Hz, 15 Amp, GFCI protected grounded circuit MUST be used to 
supply power to the Pedicure Spa. A dedicated circuit must be used with a GFCI. All wiring must conform to 
National & Local Electrical Codes

 

WARNING:

 

IT IS EXTREMELY IMPORTANT THAT THE FOOT SPA OPERATES WITH GFCI  PROTECTION

 

 

 

VERY IMPORTANT  Both back of chair and seat are adjustable. When both are at maximum positions one must 
allow 18”(44cm) from back wall to foot spa. This minimum distance assures unobstructed recline. Failure to follow 
this required dimension might damage your spa components and plumbing connections, which will void your 
warranty. 

 

PEDICURE SPA SPECIFICATIONS: 

 Construction: 

Marble 

composite, 

high gloss, acetone-proof gel coat. 

 

Two (2) electro-mechanical knobs control the drain and whirlpool. 

 

Electro-mechanically operated reclining, massaging, and sliding seat with hand held control. 

 

One (1) pipe-less whirlpool jet. (Pipe-free technology) 

 

Power drain (optional) or Gravity drain (no drain pump)   

 

Extendable water spray positioned well above water line, air gap is accommodated with back-flow 
prevention required by plumbing code 

 

Armrest swing up / down. 

 

 

SPECIFICATIONS 

  

Spa Dimensions &  
Weights 
 
 

  Vigor = 28” (W) x 56” (L).   Stellar = 26” (W) x 54” (L).   Ultima = 23” (W) x 55” (L) 
   All Models fully reclined: 74” (L).   With Manicure Tray Installed: 46” (W)  
   Empty Weight: ~ 200 lbs.   Shipping Weight: ~ 260 lbs.     
  

Adjustable Stool Height 

  Pedicure Stool: 12” – 13”.   

Spa Water Capacity 

 ~ 4-5 US Gallon 

Jet Motor 

  120 VAC. at 85W 60Hz  

Massage Motors,  
Seat Sliding & Reclining 

  24VDC, 2.5A x 5 

Discharge Pump 

  Motor – 120V at 85W 60 Hz    Maximum vertical lift: 3ft .   Flow rate 500 GPH @  floor level 

Power source 

  115 VAC, 60HZ.  Power needed per spa chair = 6 Amp  

Electrical Switches 

  One (1) electro-mechanical knob for the Whirlpool. Rated at 5A contact. 
  One (1) electro-mechanical knob for the Drain. Rated at 5A contact. 

Plug & Play Installation 

  Installation should be made with connection at the external interface parts.  
  Please consult with your local plumber. 

Safety 

   
 Ultima® Pedicure Spa is UL listed. 
 

 


background image

 

12

_______________________________________________________

Operation and Care

 

 

OPERATION AND CARE INSTRUCTIONS

 

 

Auto-Fill™:

 

      Automatic Auto-Fill™ cycle:

 

Water will automatically turn-off when optimal water level is detected by 2 sensors and followed with the 
immediate start of Whirlpool jets for a duty cycle of thirty (30) minutes. The Auto-Fill™ cycle is safely 
protected by 2 sensors, 3-minute time out and can be extended with a manually operative shut-off valve 
located at the front panel. 
 
 
 
 
 

 

      Manual conversion: 

Auto-Fill™ option can be simply reset to normal manual mode as a contingent system when automatic 
operation becomes unavailable. Please call our Customer care for step by step instructions. 
 

Panel Functional Switches & Operating Instructions: 

Hot/Cold water faucet located at the center of the front panel.

 

 

 

1.1  Use faucet knob to adjust optimal water temperature at “H” (Left) or “C” (Right) directory. 
1.2  Pull out and tilt down faucet knob to shut off water any time during the automatic or manual 

operational cycle. 

                                     

 

 
 
 
 
 
 
 

 

 

 
 
 
 
 

  

Warning

  

Must be used when spa chair is left unattended or for overnight procedures to 

shut off water supply to basin. 

Important!

  

Must scrub and clean water sensors frequently to ensure that water stops right 

at sensor level. If necessary, clean using sponge buffer. 

 


background image

 

13

______________________________________________

Operation and Care 

 

Auto-Fill™ / Jet Knob/Switch:

 

(

Dual-functional momentary switch located on the right side of the front panel

)  

 
                   1.

 To turn water on: 

Turn knob clockwise for 1 second and release. Water will fill up to reach the 

sensor level and activate the whirlpool jets to proceed a running duration of thirty (30) minutes automatically.

 

 

            2. 

To turn water off: 

Turn knob clockwise for 1 second and release to turn off water. The switch can 

be activated to turn on or turn off water any time during the Auto-Fill™ cycle, EXCEPT when water is at 
sensor level. 

 

3.

 To turn On / Off the whirlpool jet:

  Turn knob clockwise for 1 seconds and release. This Jet 

cannot be turned on if water level is not at sensor level. 

 

Drain Knob/Switch:

 

(Dual Action Electro-mechanical Switch located on the left side of the front panel) 

When activating the switch, it will raise the drain-stopper and power up the drain pump (if exist) at the 
same time. 
 

3.1  To drain water: Turn the drain knob clockwise. Switch is activated.  
 
3.2  To turn off the drain pump: Turn the drain knob counterclockwise. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 


background image

 

14

______________________________________________

Operation and Care 

 

JET COVER REMOVAL & INSTALLATION: 

 

 

1.

 

Turn Counterclockwise to remove.  Turn Clockwise to install. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 


background image

 

15

______________________________________________

Operation and Care 

 

JET HOUSING REMOVAL & INSTALLATION

 

 

1.

 

Turn clockwise to remove motor.  Turn counterclockwise to install motor. 

 

 

 

 

 
 
 
 

 


background image

 

16

______________________________________________

Operation and Care

 

 
 

MASSAGE SYSTEM & REMOTE CONTROLLER:

 

 
 
 
 

                         

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  Press Auto Button to start Auto mode.  Press again to turn off massage. 

Auto and Manual mode will run for duration of 15min. 
 

2.  Press any button (Rolling/Spot, Kneading, Tapping, Combine) to enter Manual mode.  
 
3.  Press Rolling/Spot to stop rolling up/down and stop at desired spot. 

 

4.  Press Intensity button to select tapping intensity.  

 

5. 

Vibro Button/LED is an option.  Pressing this button will resume with Tapping action.

 

 

6. 

Press any chair button (Recline, Incline, Backward, Forward) to move the chair to desired positions.

 

 
 
 

 


background image

 

17

_______________________________________________

Operation and Care

 

 

NOTE : If the Massage Chair is not provided, then the end-user will need to install a UL listed and cUL/CSA 
certified massage chair with

 

a suitable Class 2 Power Supply.

        

                                    
TOP MASSAGE CHAIR BASIC INSTALLATION INSTRUCTIONS:

 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 
                                   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
     

 

      
 
 
 
 
 
 
 
 
 
 
 

Fig.1 

Fig.3 

Fig.2 

Install seat cushion with 2 screw-Knobs 
Lever the back massage and secure 2 hinge 
screws onto the metal brackets.(Do not turn 
the screws all the way in ) 
 Leave 1/4” thread screw head for sliding 
Install back shell with 4 screws as Fig.3 

Drill 4 mounting holes ½”.Width=16.5”   
Length=11 .Install seat frame and secure 4 
screws from bottom base.Using the provided 
stand-off to adjust the height of seat frame as 
needed to allow seat frame to travel freely.          

Controller PCB 

      Lift up back massage to engage 
      locking device. (Manually adjust 
      actuator rod to lock as needed) 
      Install back cushions. 
      Plug AC cord to power strip 
      Located inside of the tub base.

 

 


background image

 

18

 

WARNING

    Y

ou must always refer to your state or local guidelines for cleaning requirements

                        

 Overnight soaking with overdosed Chlorine may damage rubber part in basin 

                             

 

CLEANING PROCEDURE

 

IS REQUIRED BY STATE BOARDS

 

 

Note:

 

*** A cleaning log should be kept with each pedicure spa ***

 

Each State will have slight differences in cleaning policies, please check with your state’s Bureau of Barbering  
and Cosmetology or Regulatory Authority for specific details.

 

 

Safety Requirements for Pedicure Spas 

 

The Bureau of Barbering and Cosmetology requires that salons using whirlpool pedicure foot spas must 
follow these disinfecting procedures to ensure proper cleaning and maintenance of the equipment and to 
prevent the spread of bacterial or parasitic disease. 
 
Violation of this section may result on an administrative fine and/or disciplinary action. Each foot spa that 
is not in compliance with this section may result in a separate violation. 
 
NOTE: Authority cited: Section 7312, Business and Profession Code. Reference: Section 7312 (e), 
Business and Professsion Code.

 

 

Below is a suggestion for your pedicure spa chair’s cleaning procedure:  

 

After Each Customer 
 

1.  All water shall be drained and all debris shall be removed from the spa basin. 
2.  The spa basin must be cleaned with soap or detergent and water 
3.  The spa basin must be disinfected with an EPA-registered disinfectant with demonstrated bactericidal, 

fungicidal, and virucidal activity, which must be used according to manufacturer’s instructions. 

4. 

The spa basin must be wiped dry with a clean towel.

 

 

At the End of Each Day 
 

1.  The screen shall be removed, all debris trapped behind the screen shall be removed, and the screen and the 

inlet shall be washed with soap or detergent and water. 

2.  Before replacing the screen, the screen shall be totally immersed in an EPA-registered disinfected with 

demonstrated bactericidal, fungicidal and virucidal activity, which must be used according to the 
manufacturer’s instructions. 

3. 

The spa system shall be flushed with low sudding soap and warm for at least 10 minutes, after which the spa 
shall be rinsed and drained.

 

 

At Least Once A Week 
 

1.  The spa basin shall be filled completely with warm water and 1 teaspoon of 5.25% bleach for each gallon of 

water, or a solution of Sodium Hypochlorite of approximately 50ppm used according to manufacturer’s 
instructions. 

2.  The spa system shall be flushed with the bleach and water solution, or Sodium Hypochlorite solution, for 5-10 

minutes and allowed to sit for 6-10 hours. 

3. 

The spa system shall be drained and flushed with water before use upon a patron.

 

 
 
 

 


background image

 

19

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

WARNING

 

PROPER INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED. 

FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND/OR WARRANTY WILL BE NULL. 
YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE 
SAFELY. UL SAFETY RECOGNIZED FOR UNITED STATES AND CANADA. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

LEXOR INC, 14800 GOLDENWEST STREET, WESTMINSTER CA 92683, USA 

CUSTOMER CARE: TEL 1-800-559-3630 FAX: 1-714-622-1740 

                                                                               www.Lexor.com 

 
 

©

2012 All Rights reserved. Design and Specifications are subject to change without notice