Page 1 

Preface 

This manual describes how to install and use the Industrial Ethernet Switch. This switch 
integrates full wire speed switching technology. This switch brings the answer to 

complicated Industrial networking environments. 

 

 

To get the most out of this manual, you should have an understanding of Ethernet 

networking concepts.   
 

In this manual, you will find: 

 

 

Features on the switch 

 

Illustrative LED functions 

 

Installation instructions 

 

Specifications 

 
 

 

 

 

 


background image

IES-0820 User Manual 

Page 2 

Table of Contents 

PREFACE .................................................................................................................. 1 
PRODUCT OVERVIEW ............................................................................................. 3 

I

NDUSTRIAL 

E

THERNET 

S

WITCH

 ......................................................................................................... 3 

P

ACKAGE 

C

ONTENTS

........................................................................................................................... 3 

P

RODUCT 

H

IGHLIGHTS

 ....................................................................................................................... 4 

F

RONT 

P

ANEL 

D

ISPLAY

 ....................................................................................................................... 5 

P

HYSICAL 

P

ORTS

 ................................................................................................................................ 6 

INSTALLATION ........................................................................................................ 7 

DIN

 

R

AIL 

M

OUNTING

......................................................................................................................... 8 

C

ONNECTING TO 

P

OWER

 .................................................................................................................... 9 

C

ONNECTING TO 

Y

OUR 

N

ETWORK

 ................................................................................................... 12 

SPECIFICATIONS ................................................................................................... 13 
APPENDIX A – CONNECTOR PINOUTS ................................................................. 15 
 

 

 


background image

IES-0820 User Manual 

Page 3 

Product Overview 

Industrial Ethernet Switch 

 

 

Package Contents 

When you unpack the product package, you shall find the items listed below. Please 

inspect the contents, and report any apparent damage or missing items immediately to 
your authorized reseller. 

 

 

IES-0820 

 

Quick Installation Guide 

 

CD User Manual

 

 

 

 


background image

IES-0820 User Manual 

Page 4 

Product Highlights 

Basic Features 

 

Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and 
vibration for traffic control equipment. 

 

Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial 
environment. 

 

UL1604 Class I, Division 2 Classified for use in hazardous locations (applicable to 

versions with terminal block power option). 

 

Supports 802.3/802.3u/802.3X. 

 

Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX. 

 

Supports 2048 MAC addresses. 

 

Provides 768K bits memory buffer. 

 

Alarms for power and port link failure by relay output 1.5A @ 24VDC. 

 

Operating voltage and Max. current consumption: 0.76A @ 12VDC, 0.38A @ 24VDC, 
0.19A @ 48VDC. Power consumption: 9.12W Max. 

 

Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with 
100-240VAC external power supply. 

 

Field Wiring Terminal: Use Copper Conductors Only, 60/75

, 12-24 AWG torque value 7 

lb-in. 

 

-40

 to 75

 (-40

 to 167

) operating temperature range. Tested for functional 

operation @ -40

 to 85

 (-40

 to 185

). UL1604 Industrial Control Equipment 

certified Maximum Surrounding Air Temperature @ 74

 (165

). 

 

Supports DIN-Rail or Panel Mounting installation. 

 

 

 

 

 

 


background image

IES-0820 User Manual 

Page 5 

Front Panel Display 

 

 

Status LEDs 

LED 

Status 

Description 

PW 1,2 

(Green) 

Steady 

Power On 

Off 

Power Off 

Fault 

FAULT 

(Red) 

Steady 

 

Redundant power is failed or not 

being used 

 

Port failure (When Port Fault Alarm is 

enabled) 

Off 

 

Redundant power is active 

 

Port failure is not occurred 

 

Port Fault Alarm is disabled 

10/100Base-TX or 100Base-FX/BX 

LNK/ACT 

(Green) 

Steady 

Network connection is established 

Flashing 

Transmitting or Receiving data 

100 

(Yellow) 

Steady 

Connection at 100Mbps speed 

Off 

Connection at 10Mbps speed 

 

 

 

 


background image

IES-0820 User Manual 

Page 6 

Physical Ports 

This switch provides: 
Eight 10/100Base-TX ports 

Eight 10/100Base-TX ports + one 100Base-FX/BX port 

Six 10/100Base-TX ports + two 100Base-FX/BX ports 
Four 10/100Base-TX ports + four 100Base-FX/BX ports 

 

Connectivity 
RJ-45 connectors 

SC or ST connector on 100Base-FX fiber port 

SC connector on 100Base-BX fiber port 
 

 

 

 

 


background image

IES-0820 User Manual 

Page 7 

Installation 

This chapter gives step-by-step instructions about how to install the switch:   
 

Selecting a Site for the Switch 

As with any electric device, you should place the switch where it will not be subjected to 

extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you 
select should meet the following requirements: 

 

 

The ambient temperature should be between -40 to 75 degrees Celsius. 

 

The relative humidity should be less than 95 percent, non-condensing. 

 

Surrounding electrical devices should not exceed the electromagnetic field (RFC) 
standards. 

 

Make sure that the switch receives adequate ventilation. Do not block the ventilation 

holes on each side of the switch   

 

The power outlet should be within 1.8 meters of the switch. 

 

 

 
 

 

 


background image

IES-0820 User Manual 

Page 8 

DIN Rail Mounting 

Fix the DIN rail attachment plate to the back panel of the switch. 

 
Installation: Place the switch on the DIN rail from above using the slot. Push the front of 

the switch toward the mounting surface until it audibly snaps into place. 

 

Removal: Pull out the lower edge and then remove the switch from the DIN rail. 

 

 

 

 

 

 

 


background image

IES-0820 User Manual 

Page 9 

Connecting to Power 

Redundant DC Terminal Block Power Inputs or 12VDC DC Jack (Optional) 

 

Redundant DC Terminal Block Power Inputs 

There are two pairs of power inputs can be used to power up this device. You need to have 

two power inputs connected to run the device, but the FAULT LED indicator will light up to 

remind that the power redundant system functions abnormal in case either PWR1 or PWR2 

is dead. This device, however, continues working normally even fault LED indicator lights 
up. 

 

Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and 

then plug it into a standard DC outlet. 

 
Step 2: Disconnect the power cord if you want to shut down the switch. 

 

 

 

Field Wiring Terminal: Use Copper Conductors Only, 60/75

, 12-24 AWG torque value 7 

lb-in. 

 

Te

rmin

al

 B

lo

ck

 

PW1 

10 – 48VDC 

– 

Power Ground 

PW2 

10 – 48VDC 

– 

Power Ground 

 

Earth Ground 

 

 

Relay Output 

1A @ 24VDC 

1.

 

The relay contact opens if Power1 or Power2 falls 

2.

 

The relay contact opens if the Port Link is broken 
(When Link Down Detection is enabled) 

 

 

 

 

 


background image

IES-0820 User Manual 

Page 10 

12VDC DC Jack Input (Optional) 

Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of 

the switch. 

 

Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a 

standard AC outlet with the appropriate AC voltage. 
 

 

 

D

C Ja

ck

 

PW1 

DC Jack 

12VDC Input 

 

Relay Output 

1A @ 24VDC 

1.

 

The relay contact close if power falls   

 
 

 


background image

IES-0820 User Manual 

Page 11 

Alarms for Power and Port Failure

 

Step 1: There are two pins on the terminal block are used for power failure detection. It 
provides the normally closed output when the power source is active. Use this as a dry 

contact application to send a signal for power failure detection. 

 

 

This DIP Switch features the Port Fault Detection; once enabled, it sends fault signal (relay 
opens) when the port link is broken 

 

On: Enable Port Fault Detection 
Off: Disable Port Fault Detection 
Note: Pin No. maps to Port No & extra Pin has no function 
 

 

Special note: 
The relay output is normal open position when there is no power to the switch. 
Please do not connect any power source to this terminal to prevent the shortage to 
your power supply. 

 

 

 
 

 

 

 


background image

IES-0820 User Manual 

Page 12 

Connecting to Your Network 

Cable Type & Length 

It is necessary to follow the cable specifications below when connecting the switch to your 

network. Use appropriate cables that meet your speed and cabling requirements. 

 

Cable Specifications 

Speed 

Connector 

Port Speed 
Half/Full Duplex 

Cable 

Max. Distance 

10Base-T 

RJ-45 

10/20 Mbps 

2-pair UTP/STP Cat. 3, 4, 5  100 m 

100Base-TX 

RJ-45 

100/200 Mbps 

2-pair UTP/STP Cat. 5 

100 m 

1000Base-T 

RJ-45 

2000 Mbps 

4-pair UTP/STP Cat. 5 

100 m 

100Base-FX 

ST, SC 

200 Mbps 

MMF (62.5μm) 

2 km 

100Base-FX 

ST, SC 

200 Mbps 

SMF (10μm) 

20, 40, 75, 100 km 

100Base-BX 

SC 

200 Mbps 

MMF (62.5μm) 

2, 5 km 

100Base-BX 

SC 

200 Mbps 

SMF (10μm) 

20, 40 km 

1000Base-SX 

SC 

2000 Mbps 

MMF (62.5μm) 

220 m, 2 km 

1000Base-SX 

SC 

2000 Mbps 

MMF (50μm) 

550 m 

1000Base-LX 

SC 

2000 Mbps 

SMF (10μm) 

10, 20, 50 km 

1000Base-BX 

SC 

2000 Mbps 

SMF (10μm) 

20, 40 km 

SFP 

1000Base-SX 

Duplex LC 

2000 Mbps 

MMF (62.5μm) 

550 m, 2 km 

1000Base-LX 

Duplex LC 

2000 Mbps 

SMF (9μm) 

10, 40, 60 km 

1000Base-BX 

Duplex LC 

2000 Mbps 

SMF (9μm) 

70 km 

 

Cabling 

Step 1:    First, ensure the power of the switch and end devices are turned off. 

<Note> 

Always ensure that the power is off before any installation.   

Step 2:    Prepare cable with corresponding connectors for each type of port in use. 

Step 3:    Consult the previous section for cabling requirements based on connectors and 

speed. 

Step 4:    Connect one end of the cable to the switch and the other end to a desired 

device. 
Step 5:    Once the connections between two end devices are made successfully, turn on 

the power and the switch is operational. 

 

 

 


background image

IES-0820 User Manual 

Page 13 

Specifications 

Ethernet Switch 

10/100Base-TX auto-negotiating ports with RJ-45 

connectors, 100Base-FX/BX fiber ports 

Applicable Standards 

IEEE 802.3 10Base-T 
IEEE 802.3u 100Base-TX/FX 

Switching Method 

Store-and-Forward 

Forwarding Rate 
10Base-T: 

100Base-TX: 

100Base-FX/BX: 

 
10 / 20Mbps half / full-duplex 

100 / 200Mbps half / full-duplex 

200Mbps full-duplex 

Performance 

14,880pps for 10Mbps 

148,810pps for 100Mbps 

Cable 

10Base-T: 

100Base-TX: 

 
100Base-FX/BX: 

 

2-pair UTP/STP Cat. 3, 4, 5 

2-pair UTP/STP Cat. 5 

Up to 100m (328ft) 
MMF (50 or 62.5μm), SMF (9 or 10μm) 

LED Indicators 

Per unit – Power status (Power 1, Power 2) 

         FAULT 

Per port –10/100TX or 100FX/BX - 

LNK/ACT (Green), 100 (Yellow) 

Dimensions 

50mm (W) × 110mm (D) × 135mm (H) 

(1.97” (W) x 4.33” (D) x 5.31” (H)) 

Net Weight 

0.8Kg (1.76lbs.) 

Power 

Terminal Block: 10-48VDC 

DC Jack: 12VDC, External AC/DC required 

Operating Voltage & Max. 

Current Consumption 

0.76A @ 12VDC, 0.38A @ 24VDC, 

0.19A @ 48VDC 

Power Consumption 

9.12W Max. 

Operating Temperature 

-40

 to 75

 (-40

 to 167

Tested for functional operation @ 

-40

 to 85

 (-40

 to 185

UL1604 Industrial Control Equipment certified 

Maximum Surrounding Air Temperature @ 74

 

(165

Storage Temperature 

-45

 to 85

 (-40

 to 185

Humidity 

5%-95% non-condensing 

Safety 

Hazardous location: Class I, Division 2 group A, B, 
C & D 

UL60950-1, EN60950-1, IEC60950-1 

EMI 

FCC Part 15, Class A 

EN61000-6-3: 

EN55022, EN61000-3-2, EN61000-3-3 

 
 

 

 


background image

IES-0820 User Manual 

Page 14 

 

EMS 
EN61000-6-2: 
EN61000-4-2 (ESD Standards) 
EN61000-4-3 (Radiated RFI Standards) 
EN61000-4-4 (Burst Standards) 
EN61000-4-5 (Surge Standards) 
EN61000-4-6 (Induced RFI Standards) 
EN61000-4-8 (Magnetic Field Standards) 
Environmental Test Compliance 
IEC60068-2-6 Fc (Vibration Resistance) 
IEC60068-2-27 Ea (Shock) 
IEC60068-2-32 Ed (Free Fall) 
NEMA TS1/2 Environmental requirements for traffic 

control equipment 

 
 

 


background image

IES-0820 User Manual 

Page 15 

Appendix A – Connector Pinouts 

Pin arrangement of RJ-45 connectors: 

 

 

 

 

RJ-45 Connector and Cable Pins 

 

 
The following table lists the pinout of 10/100Base-TX ports.   

 

Pin 

Standard Port 

Uplink Port 

Output Transmit Data + 

Input Receive Data + 

Output Transmit Data - 

Input Receive Data - 

Input Receive Data + 

Output Transmit Data + 

NC 

NC 

NC 

NC 

Input Receive Data - 

Output Transmit Data - 

NC 

NC 

NC 