PDF User Manual

  1. Home
  2. Manuals
  3. LevelOne IES-0810 User Manual

LevelOne IES-0810 User Manual

IES-0910

Made by: LevelOne
Type: User Manual
Category: Network Router
Pages: 13
Size: 0.18 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

 

 

 

 
 

 

 

 

 
 

 

IES-0810 

8 FE Unmanaged Switch -20 to 60, DIN-rail 

 

User Manual

 

 

 
 

 

 

 

 

v1.00 - 1206 


background image

IES-0810 User Manual 

Page 2 

Preface 

A member of the growing family of rugged switches, this switch addresses a need for a 
smaller switch. This switch provides an affordable solution for rugged and outdoor 

environment, transportation road-side cabinet, industrial floor shop, multitenant 

dwellings or Fiber To The Home (FTTH) applications.

 Capable of operating at temperature 

extremes of -20°C to +60°C, this is the switch of choice for harsh environments constrained 

by space. 

 

Plug-and-Play Solution: 

The switch is a plug-and-play Fast Ethernet Switch in compact size. It doesn't have any 

complicated software to set up. 

 
This manual describes how to install and use the hardened Ethernet Switch. This switch 

integrates full wire speed switching technology. This switch brings the answer to 

complicated hardened networking environments. 

 

To get the most out of this manual, you should have an understanding of Ethernet 
networking concepts.   

 

In this manual, you will find: 

 

 

Features on the switch 

 

Illustrative LED functions 

 

Installation instructions 

 

Specifications 

 

 

 


background image

IES-0810 User Manual 

Page 3 

Table of Contents 

 

PREFACE ........................................................................................................................................................ 2

 

PRODUCT OVERVIEW ................................................................................................................................... 4

 

H

ARDENED 

E

THERNET 

S

WITCH

 ............................................................................................................................................................... 4

 

P

ACKAGE 

C

ONTENTS

 ................................................................................................................................................................................ 4

 

P

RODUCT 

H

IGHLIGHTS

 ............................................................................................................................................................................. 5

 

F

RONT 

P

ANEL 

D

ISPLAY

 ............................................................................................................................................................................. 6

 

INSTALLATION ............................................................................................................................................... 7

 

S

ELECTING A 

S

ITE FOR THE 

S

WITCH

 ......................................................................................................................................................... 7

 

DIN

 

R

AIL 

M

OUNTING

 .............................................................................................................................................................................. 8

 

C

ONNECTING TO 

P

OWER

 .......................................................................................................................................................................... 9

 

C

ONNECTING TO 

Y

OUR 

N

ETWORK

 ........................................................................................................................................................ 11

 

SPECIFICATIONS .......................................................................................................................................... 12

 

APPENDIX A -  CONNECTOR PINOUTS ........................................................................................................ 13

 

 

 

 

 

 

 


background image

IES-0810 User Manual 

Page 4 

Product Overview 

Hardened Ethernet Switch 

 

 

 

Package Contents 

When you unpack the product package, you shall find the items listed below. Please 

inspect the contents, and report any apparent damage or missing items immediately to 
your authorized reseller. 

 

 

IES-0810 

8 FE Unmanaged Switch -20 to 60, DIN-rail 

 

Quick Installation Guide 

 

CD User Manual

 

 
 

 

 

 


background image

IES-0810 User Manual 

Page 5 

Product Highlights 

Basic Features 

 

Meets IEC61000-6-2 EMC Generic Standard Immunity for industrial environment. 

 

Support 802.3/802.3u/802.3X. 

 

Auto-negotiation: 10/100Mbps, Full/half-duplex; Auto MDI/MDIX. 

 

Support 2048 MAC addresses. 

 

Provides 768K bits memory buffer. 

 

Alarms for power failure by relay output. 

 

Operating voltage and Max. current consumption: 1.1A @ 12VDC, 0.55A @ 24VDC. 

 

Power consumption: 13.2W Max. 

 

Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with 

100-240VAC external power supply. 

 

Supports DIN-Rail, Panel, or Rack Mounting installation. 

 

 

 

 

 


background image

IES-0810 User Manual 

Page 6 

Front Panel Display 

Basic Features 

 

 

 

Power Status (PW1, PW2) 

These LEDs come on when the switch is properly connected to power and turned on. 

 

Port Status LEDs 

The LEDs display status for each respective port. 

 

LED 

Status 

Description 

PW 1,2 
(Green) 

Steady 

Power On 

Off 

Power Off 

10/100Base-TX or 100Base-FX/BX 

LNK/ACT 
(Green) 

Steady 

Network connection is established 

Flashing 

Transmitting or Receiving data 

100 

(Yellow) 

Steady 

Connection at 100Mbps speed 

Off 

Connection at 10Mbps speed 

 
Physical Ports 
This switch provides: 

Eight 10/100Base-TX ports 

Eight 10/100Base-TX ports + one 100Base-FX port 

Six 10/100Base-TX ports + two 100Base-FX ports 

Four 10/100Base-TX ports + four 100Base-FX ports 
 

Connectivity 
RJ-45 connector 

SC or ST connector on 100Base-FX fiber port 

 

 


background image

IES-0810 User Manual 

Page 7 

Installation 

This chapter gives step-by-step instructions about how to install the switch:   

Selecting a Site for the Switch 

As with any electric device, you should place the switch where it will not be subjected to 

extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you 

select should meet the following requirements: 

 

 

The ambient temperature should be between -20 to 60 degrees Celsius. 

 

The relative humidity should be less than 95 percent, non-condensing. 

 

Surrounding electrical devices should not exceed the electromagnetic field (RFC) 

standards. 

 

Make sure that the switch receives adequate ventilation. Do not block the ventilation 
holes on each side of the switch   

 

The power outlet should be within 1.8 meters of the switch. 

 

 

 

 


background image

IES-0810 User Manual 

Page 8 

DIN Rail Mounting 

Fix the DIN rail attachment plate to the back panel of the switch. 

 
Installation: Place the switch on the DIN rail from above using the slot. Push the front of 

the switch toward the mounting surface until it audibly snaps into place. 

 

Removal: Pull out the lower edge and then remove the switch from the DIN rail. 

 

 

 

 

 


background image

IES-0810 User Manual 

Page 9 

Connecting to Power 

Redundant DC Terminal Block Power Inputs or 12VDC DC Jack (Optional): 

 
 

Redundant DC Terminal Block Power Inputs 

There are two pairs of power inputs can be used to power up this device. You only need to 

have one power input connected to run the switch. 

 
Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and 

then plug it into a standard DC outlet. 

 

Step 2: Disconnect the power cord if you want to shut down the switch. 

 

 

 

 
 

12VDC DC Jack (Optional) 

Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of 

the switch. 

 
Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a 

standard AC outlet with the appropriate AC voltage. 

 

 

 

 
 

 


background image

IES-0810 User Manual 

Page 10 

Alarms for Power Failure 

Step 1: There are two pins on the terminal block are used for power failure detection. It 
provides the normally closed output when the power source is active. Use this as a dry 

contact application to send a signal for power failure detection. 

 

Te

rmin

al

 B

lo

ck

 

PW1 

12 -  30VDC 

-  

Power Ground 

PW2 

12 -    30VDC 

Power Ground 

 

Earth Ground 

 

 

Relay Output 

1A @ 12 - 30VDC 

1.

 

The relay contact opens if Power1 or Power2 falls 

 

 

Special note: 
The relay output is normal open position when there is no power to the switch. 
Please do not connect any power source to this terminal to prevent the shortage to 
your power supply. 

 

 

 

 


background image

IES-0810 User Manual 

Page 11 

Connecting to Your Network 

Cable Type & Length 

It is necessary to follow the cable specifications below when connecting the switch to your 
network. Use appropriate cables that meet your speed and cabling requirements. 

 

Cable Specifications 

 

Speed 

Connector 

Port Speed 

Half/Full Duplex 

Cable 

Max. Distance 

10Base-T 

RJ-45 

10/20 Mbps 

2-pair UTP/STP Cat. 3, 4, 5  100 m 

100Base-TX 

RJ-45 

100/200 Mbps 

2-pair UTP/STP Cat. 5 

100 m 

100Base-FX 

ST, SC 

200 Mbps 

MMF (62.5μm) 

2 km 

100Base-FX 

ST, SC 

200 Mbps 

SMF (9 or 10μm) 

20, 40, 75, 100 km 

 

 
 

Cabling 

Step 1:    First, ensure the power of the switch and end devices are turned off. 

 
<Note>  Always ensure that the power is off before any installation.   
 

Step 2:    Prepare cable with corresponding connectors for each type of port in use. 

 

<Note>  To connect two regular RJ-45 ports between switches or hubs, you need a 
straight or cross-over cable. 

 

Step 3:    Consult the previous section for cabling requirements based on connectors and 
speed. 

 

Step 4:    Connect one end of the cable to the switch and the other end to a desired 

device. 

 
Step 5:    Once the connections between two end devices are made successfully, turn on 

the power and the switch is operational. 

 


background image

IES-0810 User Manual 

Page 12 

Specifications 

Hardened Ethernet 
Switch 

10/100Base-TX auto-negotiating ports with RJ-45 connectors, 
100Base-FX fiber ports 

Applicable Standards 

IEEE 802.3 10Base-T 
IEEE 802.3u 100Base-TX/FX 

Switching Method 

Store-and-Forward 

Forwarding Rate 
10Base-T: 
100Base-TX/FX: 

 
10 / 20Mbps half / full-duplex 
100 / 200Mbps half / full-duplex 

Performance 

148,80pps for 10Mbps 
148,810pps for 100Mbps 

Cable 
10Base-T: 
100Base-TX: 
 
100Base-FX: 

 
2-pair UTP/STP Cat. 3, 4, 5 
2-pair UTP/STP Cat. 5 
Up to 100m (328ft) 
MMF (50 or 62.5μm), SMF (9 or10μm) 

LED Indicators 

Per unit -  Power status (PWR1, PWR2) 
Per port -    
10/100TX or 100FX -  
LNK/ACT (Green), 100 (Yellow) 

Dimensions 

50mm (W) × 125mm (D) × 135mm (H) 
(1.97” (W) × 4.92” (D) × 5.31” (H)) 

Net Weight 

0.8Kg (1.76lbs.)   

Power 

DC Jack: 12VDC, External AC/DC required 
Terminal Block: 12-30VDC 

Operating Voltage & 
Max. Current 
Consumption 

1.1A @ 12VDC, 0.55A @ 24VDC 

Power Consumption 

13.2W Max. 

Operating Temperature 

-20

 to 60

 (-4

 to 140

Storage Temperature 

-40

 to 85

 (-40

 to 185

Humidity 

5%-95% non-condensing 

Safety 

UL60950-1, EN60950-1, IEC60950-1 

EMI 

FCC Part 15, Class A 
EN61000-6-3: 
EN55022, EN61000-3-2, EN61000-3-3 

EMS 

EN61000-6-2: 
EN61000-4-2 (ESD Standard) 
EN61000-4-3 (Radiated RFI Standards) 
EN61000-4-4 (Burst Standards) 
EN61000-4-5 (Surge Standards) 
EN61000-4-6 (Induced RFI Standards) 
EN61000-4-8 (Magnetic Field Standards) 
EN61000-4-11 (Voltage Dips Standards) 

Environmental Test   
Compliance 

IEC60068-2-6 Fc (Vibration Resistance) 
IEC60068-2-27 Ea (Shock) 
IEC60068-2-32 Ed (Free Fall) 

 

 


background image

IES-0810 User Manual 

Page 13 

Appendix A -  Connector Pinouts 

Pin arrangement of RJ-45 connectors: 
 

 

 

 

RJ-45 Connector and Cable Pins 

 
 

The following table lists the pinout of 10/100Base-TX ports.   

 

Pin 

Standard Port 

Uplink Port 

Output Transmit Data + 

Input Receive Data + 

Output Transmit Data - 

Input Receive Data - 

Input Receive Data + 

Output Transmit Data + 

NC 

NC 

NC 

NC 

Input Receive Data - 

Output Transmit Data - 

NC 

NC 

NC 

NC