background image

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just
a little preventative care on your part can save you a great deal of time and money over the life of
your air conditioner. Before operating this product, please read the instructions carefully and save this
manual for future use.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

Inside you will find many helpful hints on how to use and maintain your air conditioner
properly. Just a little preventive care on your part can save you a great deal of time
and money over the life of your air conditioner. You'll find many answers to common
problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting
Tips first, you may not need to call for service at all.

Contact the authorised service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or infirm persons without
supervision.
Young children should be supervised to ensure that they do not play with the air
conditioner.
If the power cord is to be replaced, replacement work shall be performed by authorised
personnel only.
Installation work must be performed in accordance with the national wiring standards
by authorised personnel only.

!

CAUTION

Rea d This Manua l

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

CONTENTS

The rating data indicated on the energy label is based
on the testing condition of installing the un-extended
air exhaust duct without adaptor A & B (The duct and
the adaptor A & B are listed in the accessories chart
of the Instruction Manual).

NOTE

SOCIABLE REMARK

Sociable remark..................................................................................................................................2

SAFETY PRECAUTIONS

Safety rules .......................................................................................................................................3
Operating condition ...........................................................................................................................3
Electrical information .........................................................................................................................4

Accessories .......................................................................................................................................4
Names of parts...................................................................................................................................5

Electronic control operating instructions ...........................................................................................6

Operating instructions .......................................................................................................................7

Location ............................................................................................................................................9
Window kit installation ......................................................................................................................9
Exhaust hose installation ................................................................................................................12
Water drainage ................................................................................................................................13

Care and maintenance ....................................................................................................................14

Trouble shooting ..............................................................................................................................15

AIR CONDITIONER FEATURES

CARE AND MAINTENANCE

TROUBLESHOOTING TIPS

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IDENTIFICATION OF PARTS

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

SOCIABLE REMARK

DISPOSAL:

Do not dispose this product as unsorted municipal waste. Collection of

such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can be

disposed of at least free of charge to the user.

B) When buying a new product, the retailer will take back the old product at least free

of charge.

C) The manufacture will take back the old appliance for disposal at least free of charge

to the user.

D) As old products contain valuable resources, they can be sold to scrap metal dealers.

Wild disposal of waste in forests and landscapes endangers your health when
hazardous substances leak into the ground-water and find their way into the food chain.

When using this air conditioner in the European countries, the following informa-
tion
must be followed:

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage.

Your air conditioner should be used in such a way

that it is protected from moisture. e.g. condensation,

splashed water, etc. Do not place or store your air
conditioner where it can fall or be pulled into water
or any other liquid. Unplug immediately.

Always transport your air conditioner in a vertical

position and stand on a stable, level surface during
use.
Turn off the product when not in use.

Always contact a qualified person to carry out

repairs. If the supply cord is damaged it must be
repaired by a qualified repairer.
Keep an air path of at least 30cm all around the
unit from walls, furniture and curtains.
If the air conditioner is knocked over during use,
turn off the unit and unplug from the mains supply
immediately.

SAFETY PRECAUTIONS

!

Always do this

Do not operate your air conditioner in a wet room
such as a bathroom or laundry room.
Do not touch the unit with wet or damp hands or
when barefoot.
Do not press the buttons on the control panel with
anything other than your fingers.
Do not remove any fixed covers. Never use this
appliance if it is not working properly, or if it has
been dropped or damaged.
Never use the plug to start and stop the unit.

Always use the switch on the control panel.

Do not cover or obstruct the inlet or outlet grilles.
Do not use hazardous chemicals to clean or come
into contact with the unit. Do not use the unit in the
presence of inflammable substances or vapour such
as alcohol, insecticides, petrol,etc.
Do not allow children to operate the unit
unsupervised.
Do not use this product for functions other than
those described in this instruction manual.

Never do this

Energy Save

Use the unit in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.

Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out.

The air conditioner must be operated within the temperature range indicated below:

Operating condition

Safety rules

Suggested tools for window kit installation

1. Screwdriv er(medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
4. Saw(In the event that the window kit needs to be cut down in size because

the windo w is too narrow for direct installation)

MODE

ROOM TEMPERATURE

COOL

DRY

17 C(62 F)~35

O

O

O

O

C(95 F)

13 C(55 F)~35

O

O

O

O

C(95 F)

HEAT(heat pump type)

5 C(41 F)~

O

O

30 C(86 F)

O

O

HEAT(electrical heat type)

<30 C/86 F

O

O

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

Be sure the electrical service is adequate for the model you have chosen. This information can be found
on the serial plate, which is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is
important. The power cord is equipped with a three-prong grounding plug for protection against shock
hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend
to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified
electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.

WARNING

For your safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove
any prong from the power cord.

WARNING

Electrical Infor mation

IDENTIFICATION OF PARTS

Check all the accessories are included in the package and please refer to the installation instructions for
their usage.

NOTE: Optional parts(

), some models without.

All the illustrations in this manual are for explanation purpose only. Your air conditioner
may be slightly differen t. The actual shape shall prevail.

NOTE:

Accessories

PARTS :

PARTS NAME :

Wall Exhaust Adaptor A(

)

 

Expansion Plug and wooden screw( )

 

QUANTITY :

1 set

1 set

1 pc

4/ pc

Foam seal

3/pc

Remote Controller and Battery

(For remote control models only)

1set

Drain hose

Adaptor B(round mouth) ( )

 

1pc

( )

 

or

Exhaust hose(supplied), adaptor B(round

mouth or flat month:depending on models)

and Window Slider Kit and bolt ( )

 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

IDENTIFICATION OF PARTS

NAMES OF PARTS

Front

Operation Panel

Horizontal Louver Blade
(swing automatically)

Carrying Handle
(both sides)

1

2

3

Fig.1

Fig.2

Rear

6

7

8

9

10

11

Upper Air Filter
(Behind the grille)

Air Outlet

Drain Outlet

Wheel

Air intake

Air intake

Lower Air Filter
(Behind the grille)

12

4

Remote signal receptor

5

5

Panel

13

Bottom tray drain outlet

1

2

3

5

4

8

9

10

11

12

6

7

13

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

AIR CONDITIONER FEATURES

Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbol for the functions you desire.

The unit can be controlled by the unit control panel alone or with the remote controller .

ELECTRONIC CONTROL OPERATING INSTRUCTIONS

Fig.3

NOTE: This man ual does not include Remote Controller Operations, see the <<Remote
Controller Instruction>> packed with the unit for details.

OPERATION PANEL OF THE AIR CONDITIONER

Selects the appropriate operating mode.
Each time you press the button, a mode
is selected in a sequence that goes from
AUTO, COOL, DRY, FANandHEAT(cooling
only models without) .The mode indicator
light illuminates under the different mode
setting.

NOTE:

The control is capable of displaying

temperature in degrees Fahrenheit or degrees

Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same

time, for 3 seconds.

Used to initiate the AUTO ON start time
and AUTO OFF stop time program, in
conjuction with the

&

buttons.

UP(

) and DOWN( ) button

Used to adjust (increasing/decreasing)
temperature settings(1 C/1 F increments)
in a range of 17 C(62 F) to 30 C(86 F) or
the TIMER setting in a range of 0~24hrs.

Use this button to initiate/cancel the auto
swing feature .

SWING button

MODE select button

Power switch on/off.

POWER button

SPEED button

TIMER button

Used to initiate the SLEEP operation.

SLEEP button

-Shows the set temper atur e in

C

O

"

"

"

"

or

F and the Auto-timer setti ngs.

Whi le on DRY and FAN modes, it shows
the room temperature.

O

LED Display

Press to select the fan speed in four steps-
AUTO,LOW, MED(on some models)and

HIGH.The fan speed indicator light

illuminates under different fan settings
except AUTO speed. When select AUTO
fan speed, all the fan indicator lights turn
dark.

Remote signal recep tor

Press the ION button, the ion genera tor
is ene rgi zed an d will help to r emove
po llen and impuritie s f rom the ai r, and

tr ap t hem in the filt er. Press i t again to

st op t he func tion.

ION button(optional)

NOTE :On som e model s
is TEM P SENS ING.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

OPERATING INSTRUCTIONS

Operating Instructions

-

Press the "MODE " button until the "COOL"

indicator light comes on.

-

Press the ADJUST buttons "

" or "

" to

select your desired room temperature. The
temperature can be set within a range of
17 C-30 C/62 F-86 F.

-

Press the "FAN SPEED" button to cho ose the

fan speed.

O

O

O

O

-

Press the "MO DE" button until the

"DRY" indicator light comes on.

COOL operation

DRY operation

-

Press the "MODE" button until the

"FAN " indicator light comes on.

-

Press the "FAN SPEED" button to
choose the fan speed. The temperature
cannot be adjusted.

-

Do not put the duct to window.

FAN operation

TIMER operation

-

Press the "MODE " button until the "HEAT"

indicator light comes on.

-

Press the ADJUST buttons "

" or "

" to

select your desired room temperature. The
temperature can be set within a range of
17 C-30 C/62 F-86 F.

-

Press the "FAN SPEED" button to cho ose the

fan speed. For some m odels, the fan speed
can not be adjusted under HEAT mode.

O

O

O

O

HEAT operation

(cooling only models without)

without), or fan only operation depen-
ding on what temperature you have
selected and the room temperature.

-

When the unit is on, first press the

Timer button, the TIMER OFF
indicator light illuminates. It indi-
cates the Auto Stop program is
initiated.

-

-

Press or hold the UP or DOWN

b utton to change the Auto time by
0 .5 hour increments, up to 10 hours,
t hen at 1 hour increments up to 24
h ours. The control will count down
t he time remaining until start.

-

The selected time will register in 5

seconds and the system will autom-
a tically revert back to display the
p revious temperature setting.

- Turning the unit ON or OFF at any

t ime or adjusting the timer setting
t o 0.0 will cancel the Auto Start/
Stop timed program.

-

When the malfunction (E1 or E2)

o ccurs, the Auto Start/Stop timed
p rogram will also be cancelled.

When the unit is off, first press the

Timer button, the TIMER ON indic-
a tor light illuminates. It indicates
t he Auto Start program is initiated.

-

The air conditioner will control room

temperature automatically round the
temperature point set by you.

-

Under AUTO mode, you can not

select the fan speed.

-

Under this mode, you cannot select a

fan speed or adjust the temperature.

-

Keep windows and doors closed for

the best dehumidifying effect.

-

Do not put the duct to window.

E2-

E4-

P1-

Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.

error-

Unplug the unit and plug it back in.
If error repeats, call for service.
Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.

Display panel communication

Error codes and protection code:
E1-

Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.

To a ctiv ate the FO LL OW ME/TE MP SE NSING
f eat ure ,the ind ica tor ligh t fla she s.

FOLLOW ME/TEMP SENSING indicator
(on some models)

FOLLOW ME/TEMP SENSING operation(on
some models)

AUTO operation

-

When you set the air conditioner in

AUTO mode, it will automatically select
cooling, heating(cooling only models

This feature can be activate d
from the remote control ONLY.
The remote control serves as a
remote thermostat allowing for
the precise temperature control
at its location.

To activate the FOLLOW ME/TEMP
SENSING feature, point the remote
control towards the unit and press
the Follow Me button. The light on
the unit control

NOTE:

When more than one errors occur,
the priority of the code display order is:

E4--E2--E1--P1.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

OPERATING INSTRUCTIONS

Other features

After th e un it ha s sto pp e d, it ca n n ot b e r esta rte d
o p er ation in th e fir st 3 mi nute s. Th is is to p rot ect
t he uni t. Op erat ion w ill au tom at icall y sta rt aft er
3 m in ut es.

Wait 3 minutes before resuming operation

Th e lo uv er ca n be a dju sted a ut om a tic al ly .

Whe n the P o we r i s ON , the lo u ve r o pe ns f ull y.
Pr es s the S WIN G b utt on o n t he p an el o r
re m ote c on tr oll er to in iti ate t he Auto s w ing
fe at ur e.
Th e lo uv er w ill sw in g u p an d do wn

A dj us t t he a ir flo w di re ct io n a utomat ica ll y
(F ig .4 ):

au to m at ica lly.
Pl ea se d o no t a dj us t t he lo uv er man u all y.

Air flow direction adjustment

F ig.4

SLEEP operation

Press this button, the set temperature will increase
(cooling) or decrease(heating) by 1

in 30

minutes.The set temperature will then incre ase
(cooling) or decrease (heating) by another 1
after an additional 30 minutes. This new temper-
ature will be maintained for 7 hours before it returns
to the originally selected temperature. This ends

the Sleep mode a nd the unit will continue to ope-

rate as originally program med.

This feature is unavailabe under FAN or

DRY mode.

O

O

O

O

C/2 F

C/2 F

NOTE:

S wing auto mati cally

panel will ill umina te to indica te it re ceive d the
signal.It wil l conti nue to send this s ignal until
the fe ature is dea ctivat e d by pressing the
Follow Me b utton again . If the unit d oes n ot
receiv e the Follow Me s ignal during any 7
minut es inte rval, the un it will beep to indi cate
the Fo llow M e mo de ha s ende d. Th e disp lay on
the re mote contro l indic ates t he tem pera ture
at the remo t e ON LY.

I f th e un it b re ak s o ff un ex pe ct edly d ue to th e
p ow e r c ut, it w il l re st art wi th th e p re vio us
f un ct ion se tting au to m ati ca lly wh en th e po we r
r es um es.

Auto-Restart(on some models)

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

INSTALLATION INSTRUCTIONS (optional)

INSTALLATION INSTRUCTIONS

Location

Window Slider kit Installation

If the window opening is less than the mentioned

minimum length of the window slider kit, cut that one
with a hole in it short to fit for the window opening. Do
never cut out the hole in window slider kit.

Note:

Fig.5

or

b olt

Window s lider kit

bo lt

Window
slider kit

or

Ho riz on tal
win dow

Window Slider Kit
Min im um:A cm ( aft ).
Maxm um:B cm ( bft ).

W in do w Sli de r K it
Mini mum:A cm (af t).
Maxmum :B cm (bf t).

Horizontal
window

Win dow Slider Kit
Minimum:A cm(aft).
Maxmum:B cm(bft).

Horizontal
win dow

or

Ho rizo nta l
wi nd ow

Wi nd ow S lider K it
Minimum:A cm(a ft) .
Ma xmum:B cm(b ft) .

or

Fig.7a

Fig.6

Fig.7

The air conditioner should be placed on a firm
foundation to minimize noise and virbration. For
safe and secure positioning, place the unit on a
smooth, level floor strong enough to support the unit.
The unit has casters to aid placement, but it should
only be rolled on smooth, flat surfaces. Use caution
when rolling on carpet surfaces. Do not attempt to
roll the unit over objects.
The unit must be placed within reach of a properly
rated grounded socket.
Never place any obstacle s around the air inlet or
outlet of the unit.
Allow at least 30cm of space from the wall for
efficient air-conditioning.

Your window slider kit has been designed to fit most
standard

Vertical

and horizontal window

applications, However, it may be necessary for you to
improvise/m odify some aspects of the installation
procedures for certain types of window. Please refer
to Fig. 6& Fig.7 for minimum and maximum window
openings.Window slider kit can be fixed with a bolt
(see Fig.7a).

"

"

"

"

A

B

a

b

Type I
Type II

67.5
56.2

2.22
1.84

123

4.04

98.2 3.22

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

INSTALLATION INSTRUCTIONS (optional)

Installation in a double-hung sash
window

1. Cut the foam seal(adhesive type) to the proper

length and attach it to the window stool. Fig.8

2. Attach the window slider kit to the window stool.

Adjust the length of the window slider kit according
to the width of window, shorten the adjustable window
kit if the width of window is less than

inches.

Open the window sash and place the window slider
kit on the window stool. Fig.9

3. Cut the foam seal(adhesive type) to the proper

length and attach it on the top of the window. Shown
as in Fig.10.

4. Close the window sash securely against the

window.

5. Cut the foam seal to an appropriate length and

seal the open gap between the top window sash
and outer window sash. Shown as in Fig.11.

26.5 (Type I)

or 22.1 (Type II)

Foam seal A
(adhesive type)

Window kit

Window stool

Foam seal

F ig.8

Fig .9

F ig .1 0

Fig.11

Window kit

Window stool

Window kit

Window stool

or

Window kit

Window stool

or

22.1 ~ 38.6

C

Type I
Type II

26.5 ~ 48.0

C

C

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

INSTALLATION INSTRUCTIONS (optional)

Installation in a sliding sash
window

1. Cut the foam seal(adhesive type) to the prop er

length and attach it to the window frame,Fig.12.

2. Attach the window slider kit to the window sto ol.

Adjust the length of the window slid er kit according
to the width of window, shorten the adjustable window
kit if the width of window is less than 26.5 (Type I)
or

inches. Open the window sash and

place the window slider kit on the window stool.
See Fig.13.

3. Cut the foam seal(adhesive type) to the prop er

length and attach it on the top of the window.

Shown as in Fig.14.

4. Close the sliding sash securely against the window.

5. Cut the foam seal to an appropriate length and

seal the open gap between the top window sash
and outer window sash. Shown as in Fig.15.

22.1 (Type II)

Foam seal

Foam seal A
(adhesive type)

Window
panel

Fig.1 2

Fig. 13

Fig.1 4

Fig.15

Window
panel

or

or

C

22.1 ~ 38.6

C

Type I
Type II

26.5 ~ 48.0

C

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

INSTALLATION INSTRUCTIONS

Exhaust hose installation:

The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode.

The duct can be compressed or extended moderately
according to the installation requirement, but it is
desirable to keep the duct length to a minimum.

1. Install the window Exhaust adaptor B onto the exhaust

hose as shown in Fig.16 or Fig.17 Refer to the previous
pages for window kit installation.

2. Push the Exhaust hose into the air outlet opening along the

the arrow direction(See Fig.18)

IMPORTANT:

DO NOT OVER BEND THE DUCT (SEE Fig.20)

Fig.17

Fig .18

Fig.20

(Not applicable to the units without adaptor A, expansion

plugs and wooden screws of Accessories )

1. Prepare a hole in the wall. Install the wall Exhaust adaptor A

onto the wall(outside) by using 4 expansion plugs and
wooden screws, be sure to fix thoroughly. (See Fig.19)

2. Attach the Exhaust hose

to

wall Exhaust adaptor A.

The exhaust hose can be installed into the wall

.

installed adaptor B(round mouth)

Fig.19

ma x 120CM

min 30 CM

Adaptor A

Expa nsion plug
posit ion

Adaptor
cap

Note:

Cover the hole using the adaptor cap when not in use.

Fig.16

COOL,HEAT(heat pump type) or AUTO mode

FAN,DEHUMIDIIFY or HEAT(electrical heat type) mode

Install

Remove

CAUTION:

Make sure that th ere is no obstacle around the air outlet of
the exhaust hose (in the range of 500 mm ) in order to the
exhaust syste m works prop erly.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

INSTALLATION INSTRUCTIONS

Water drainage:

-

During dehu mid ifying mo des, rem ove the drain

plug from the back of the unit, install the drain

connector(5/8 universal female m ender) with

3 4 hose(locally purchased). For the m odels

without drain connector, just attach the drain

ho se to the hole . Pla ce the open e nd of the

ho se directly ove r the drain area in your

ba sem ent floor. Plea se re fer to Fig.21 & 22.

-

When the water level of the bottom tray reaches

a predetermined level,

Carefully move the unit to a drain location,

remove the bottom drain plug and let the

water drain away(Fig.23). Restart the machine

until the P1 symbol disappears. If the error

repeats, call for service.

"

"

the unit beeps 8 times,

the digital display area shows P1 . At this time

the air conditioning/dehumidification process will

immediately stop. However, the fan motor will

continue to operate(this is normal).

"

"

C ontinuous
d rain hose

Fig.21

Fig.22

Fig.23

Rem ove the
drain plug

NOTE: Be sure to reinstall the bottom drain plug

before using the unit.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

CARE AND MAINTENANCE

CARE AND MAINTENANCE

1) Be sure to unplug the unit before cleaning or servicing.
2) Do not use gasoline, thinner or other chemicals to clean

the unit.

3) Do not wash the unit directly under a tap or using a hose.

It may cause electrical danger.

4) If the power cord is damaged, it should be repaired by

manufacture or its agency.

IMPORTANT:

1. Air filter

-

Clean the air filter at least once every two weeks to prevent

inferior fan operation because of dust.

-

This unit has two filter. Grasp the upper filter tab and take it
out along the arrow direction as shown in Fig.24.
Remove the lower filter by loosening the screws(Fig 25),
then grasp the filter tab and take it out along the arrow
direction as shown in 24.

-

Wash the air filter by immersing it gently in warm water
(about 40 C/104 F) with a neutral detergent. Rinse the filter
and dry it in a shady place.

-

Install the upper air filter after cleaning and install the lower
filter by using the screw.

Removal

Cleaning

Mounting

O

O

2. Unit enclosure

-

Use a lint-free cloth soaked with neutral detergent to clean

the unit enclosure. Finished by a dry clean cloth.

Fig .24

3. Unit idle for a long time

Upper filter
(take out)

-

Remove the rubber plug at the back of the unit and attach

a hose to drain outlet

(See Fig.23 & 24).

-

Remove the plug from the bottom drain outlet, all the water

in the bottom tray would drain out (See Fig.23).

-

Keep the appliance running on FAN mode for half a day in

a warm room to dry the appliance inside and prevent mold
forming.

-

Stop the appliance and unplug it, wrapped the cord and

bundle it with the tape. Remove the batteries from the
remote controller.

-

Clean the air filter and reinstall it.

-

Disconnect the exhaust hose, keep it safety, and cover the

window(wall) hole with the adaptor cap.

. Place the open end of the hose

directly over the drain area in your basement floor

Fig.25

NOTE:

The grill and the air filer are connected and can not be

separated.

Remove the
screws

Lower filter
(take out)

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

TROUBLESHOOTING TIPS

TROUBLE SHOOTING

1. Unit does not

Start when

Pressing on/off

Button

TROUBLES

POSSIBLE CAUSES

SUGGEST REMEDIES

Reset the temperature.

Make sure all the windows and

doors are closed.

Remove the heat sources if possible.

Connect the duc t and make

sure it can function properly.

Decreas e the set temperature.

Clean the air filter.

- Room temperature is lower than

the set temperature.(Cooling mode)

- The windows or doors in the room

are not closed.

- There are heat sources inside the

room.

- Exhaust air duct is not connec ted or

blocked.

- Temperature s etting is too high.

- Air filter is blocked by dust.

2. Not cool enough

Place the unit on a flat, level

ground if possible.

It is normal.

- The ground is not level or not flat

enough.

- The sound comes from the flowing

of the refrigerant inside the

air-conditioner.

4. Noisy o r vibration

5. Gurgling sound

Switc h on again after the unit
has c ool down.

- The au tomatic ov er heat

pr otection function . Whe n t he
t emperature at th e a ir ou tlet
ex ceed 70 C/158 F,the de vic e

wi ll sto p.

O

O

6. Power shut off at

Heating mode

- P1 appears in the display window

Dra in the water in the bottom tray.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

 


background image

CP001IU-G(J)(G)

202000192543

The design and specifications are subject to chan ge witho ut prior notice for product
improvement. Consult with the sales agency or manufactu rer for details.

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn