PDF User Manual

  1. Home
  2. Manuals
  3. Levante LEV18 SERIES User Manual

Levante LEV18 SERIES User Manual

Made by: Levante
Type: User Manual
Category: Air Conditioner
Pages: 16
Size: 20.82 MB

 

Download PDF User Manual



Full Text Searchable PDF User Manual



background image

USER MANUAL

LEV18 SERIES

PORTABLE AIR-CONDITIONER

 


background image

www.levanteinternational.com.au

1

Congratulations on purchasing the LEV18 portable air conditioner by Levanté. Please

ensure you read this manual carefully prior to use, and if you have any questions, please

contact our Customer Care Center for assistance.

CONTENTS

CONTENTS....................................................................................................................................1
SAFETY INFORMATION ................................................................................................................2
FEATURES.....................................................................................................................................3
CONTROL PANEL..........................................................................................................................4
REMOTE CONTROL ......................................................................................................................6
OPERATION...................................................................................................................................7
INSTALLATION...............................................................................................................................8
WATER DRAINGE........................................................................................................................ 10
MAINTENANCE............................................................................................................................ 11
TROUBLE SHOOTING................................................................................................................. 12
INSTALLATION ACCESSORIES................................................................................................... 13
WARRANTY ................................................................................................................................. 14
APPENDIX.................................................................................................................................... 15

 


background image

two weeks.

 


background image

8. exhaust air grille

13. Water tank drain plug 

13

 


background image

 


background image

www.levanteinternational.com.au

5

2. LED display

COOL

:

On cooling mode, the led will illuminate.

FAN:

On fan mode, the led will illuminate.

DRY:

ON dehumidifying mode, the led will illuminate.

COMP:

When compressor is working, the led will illuminate.

FULL:

When water is full in the machine, the led will illuminate.

ADD WATER

:

When the LED is illuminated, add some water to the reservoir (10).

HIGH

:

When the fan speed is high, the led will illuminate.

MED:

When the fan speed is medium, the led will illuminate.

LOW:

When the fan speed is low, the led will illuminate.

Indicates the time and temperature. ERROR Display E

X

(

X

=2,3,5)

will appear when there is a fault. (refer to Trouble Shooting & Self

Diagnosis on page 13)

Display will read E4 when the coil is defrosting, this is normal.

Celsius and Fahrenheit degree indicator.

 


background image

LEV18 remote control 

To change the display setting from Celsius to Fahrenheit, press the Up and 

Down button together on the control panel for at least 2 seconds.

 


background image

to select fan speed.

 


background image

www.levanteinternational.com.au

8

INSTALLATION

1. Positioning

Install the unit on a dry, flat surface.

Leave at least 50cm space around the

unit (when the hose is not connected).

(Fig.5)

2. AIR Exhaust Duct Mounting

1) Fix the square end of the exhaust duct

2) Put the other end (outlet) to the

nearest window. Do not block the

outlet & Leave at least 50cm

for airflow around it.

NOTE:

The length of the air exhaust duct is between 600cm & 1700cm or 1800cm. To save energy,

we suggest using the minimum length of the air exhaust duct.

This length has been designed according to the specifications of the air conditioner.

Do not use an extension or different hose as this may lead to Air Conditioner

malfunction.

3. Window Kit Installation

The window kit has been designed to fit most standard vertical and horizontal windows.

However, it may be necessary for you to modify some aspects of the installation procedures

for certain types of windows. Please refer to the illustrations. (Fig.7 and Fig.8)

to the exhaust air grille.

 


background image

www.levanteinternational.com.au

9

4. Mounting Illustrations

4.1 Mounting in the wall

4.2 Correct duct bending

4.3 Incorrect duct bending

 


background image

 


background image

www.levanteinternational.com.au

11

MAINTENANCE

Cleaning

Turn off the unit and pull the plug out of the socket before any cleaning.

1. Clean the surface

Clean the surface of the unit with a duster or a damp soft cloth.

Do not use chemical solvents such as benzene, alcohol, gasoline etc,

or the surface may be damaged or even deformed.

2. Clean the air filter

If the air filter is blocked with a lot of

dust, the efficiency will reduce. You

should clean the filters every two

weeks.

1) Pull out the air filter as Fig.14.

2) Wash the air filters by immersing

them gently into warm (40

°

C or 104

°

F) water with neutral detergent.

Rinse the filter and dry it in a

shaded place.

3) Push the air filter back into the

original position.

End of season

1. Uncap the water drain lid, remove the rubber plug to drain the water. You can remove

the water entirely by slanting the unit back.

Setting the fan mode, then press the Fan button for 5 seconds until the lower fan

works. After that, operate the unit in fan mode for half a day until the pipe is dry. In

this way the inside of the unit will be dry and possible mildew growth can be

suppressed.

2. Switch off the unit and disconnect the plug from the power supply.

3. Neaten the Power Cord using the storage hooks refer fig.2 (11).

4. Remove the flexible exhaust air duct and store safely.

5. Cover the unit with a plastic bag, and store in a dry place.

6. Remove the batteries from the remote control.

 


background image

www.levanteinternational.com.au

12

TROUBLE SHOOTING

Before contacting professional service, please firstly check the following.

Trouble

Check

Solution

The unit doesn’t

operate at all.

Is power available?

Is plug secure?

Is power fuse or switch off?

Is the auto-on timer set?

Is water full alarm on?

Insert the plug firmly.

Change the fuse or switch on.

Change the set time.

Drain the water.

Is air inlet or outlet blocked?

Is there any other heat source in

room?

Are air filters very dirty?

Is the set temperature suitable?

Is fan speed set at low?

Clear any blockages.

Remove the heat source.

Clean the air filters.

Change temperature.

Select suitable fan speed.

Unit noisy and

vibrating

Is it inclined?

Place it in a flat place.

The unit starts and

stops frequently

Is the exhaust tube fitted

correctly or is it bent?

Have you added extra exhaust

duct?

Set the exhaust tube correctly.

Remove the extra duct.

Immediately Stop the unit and disconnect in case of the following & Contact a

professional service advisor for assistance.

·

Household Fuses, Circuit Breakers or Safety Switches repeatedly fail with unit plugged in.

·

The power cord is very hot, disfigured or broken.

·

There is abnormal odor or smoke from the unit.

Self-diagnosis function

Note:

When display reads

E4

, it means that the coil is defrosting. This is a normal status.

Cooling efficiency 

is not normal

 


background image

Flexible Exhaust duct

 


background image

www.levanteinternational.com.au

14

WARRANTY

Levanté International Pty. Ltd. reserve the right to reject any warranty claim deemed to be

false. Retailers must have warranty claims authorised by a representative of Levanté

International.

If you believe your product to be faulty and under warranty you are required to do the

following:

1.

Return the product with all the accessories, at your expense, to the place of purchase for
assessment by an authorised representative of Levanté International.

2.

This may require leaving the product at the place of purchase.

3.

If the product is deemed faulty and under warranty, the place of purchase of the product
will order a replacement portable air conditioner to which Levanté International, at our cost,
will deliver the portable air conditioner to the place of purchase.

4.

The consumer will then be required, at their cost, to pick up the replacement portable air
conditioner from the place of purchase.

5.

If the portable air conditioner is faulty but not deemed to be under warranty, an explanation
will be provided to the consumer and that the faulty portable air conditioner can be picked
up by the customer from the place of purchase.

Our goods come with guarantees that cannot be excluded under the Australian Consumer

Law. You are entitled to a replacement or refund for a major failure and for compensation

for any other reasonably foreseeable loss or damage. You are also entitled to have the

goods repaired or replaced if the goods fail to be of acceptable quality and the failure does

not amount to a major failure.

If you have any queries regarding your product or its warranty please contact:

Levanté International Pty Ltd

80-84 Burlington St

Oakleigh Victoria 3166

Australia

P:

1 300 664 768

E:

sales@levanteinternational.com.au

Your Levanté LEV18 portable air conditioner comes with a 

3 YEAR IN-STORE REPLACEMENT 

WARRANTY

, therefore any replacement of faulty parts or repairs of any kind must be carried 

out by a qualified person and authorised by Levanté International Pty Ltd or their approved 

representative.Failure to do so will 

VOID

 the 

WARRANTY.

 


background image

www.levanteinternational.com.au

15

APPENDIX

Fuse Parameter

Type: FSD

Voltage: 250V

Current: 3.15A

Disposal: Do not dispose this product as unsorted municipal waste.

This unit contains CFC’s and separate collection and disposal methods are

required by law to protect our environment.